| 1 | M&L for Precast cement concrete block type C-1, 1:3:6 (20mm graded aggregate) masonry with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 including Demolition of Brickwork or stone / boulder masonry , built in cement mortar or cement lime mortar including all quoins, arches , pillars, etc, for ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling complete all as specified and directed by Engr-in-Charge. |
| 2 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, for ashlar facings, dressed stonework and precast concrete articles and precast concrete block wallingetc, complete all as specified and as directed by Engineer in charge. |
| 3 | M&L for Providing 25 mm thick precast cement concrete louvres jafri wall and jallies of Type B0 1:2:4 (12.5mm gradede aggregate) set in 1:4 cement mortar (measured solid), in cluding all mould- ings and frame all as specified and directed. |
| 4 | M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engr-in-Charge. |
| 5 | S&F in repair for galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining fixing to any type of strandard rail straining bolts,including securing or tying at crossing with provision of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured) |
| 6 | S&F in repair concertina coil 600mm dia (in stretched position) hot dip galvanized steel wire coated with CLR anti corrosive paint, making diamond shape with the help of dovetail clips (18 SWG) fixed over and including razaor wire, medium barb, hot dip galvanized steel wire razor wire with angle iron. The concertina coil to be fixed with razor wire at points wherever coil touches bottom of razor wire with the help of hog rings (14 SWG) including all fittings like fastener clips,steel lug rings etc complete all as specified and directed. Note- (i) Stretch length of each coil shall be 6 mtr complete all as specified and directed. (ii) Angle iron shall be measured paid separately under respective item of schedule of works. |
| 7 | Taking down cement or cement lime plaster of any description on brick or stone walls etc including raking out joints, hacking for key etc complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 9 | Material and labour for preparation of newly plastered surface of wall and applying two coat of cement based paint over a coat of primer complete all as specified and directed by Engr-in-Charge. |
| 10 | Excav over area not exc 1.5 m deep & getting out in Hard/dense soil complete all as specified |
| 11 | M&L PCC Type C2 1:3:6 (40 mm graded aggregate) as in fdn concrete complete all as specified |
| 12 | M &L Walling of random rubble,uncoursed, well bonded, bedded and solidly hearted, built in CM (1:4) complete all as specified and directed. |
| 13 | M&L for Struck pointing to block in course tp squared rubble coursed or uncoursed masonryor concrete block walling in CM 1:4 complete all as specified |
| 14 | Returning fillings in soil including spreading leveling walling and well ramming in layers not exc 25 cum. |
| 15 | Removal of excavated materials not exceed 50mtr and depositing where directed at a level not exc 1.5m above the starting point. Please Enable Macros to View BoQ information |