| 1 | Supply, installation, testing and commissioning of centrifugal type, electrically driven pumping set having discharge capacity of 90 litres per second against a total head of 30 metres, CI impeller complete with 50 HP squirrel-cage induction TEFC IE-2 NFLP motor, gland packing type sealing arrangement suitable for 415 volts, 3-phase, 50 Hz AC supply, including coupling, common MS base plate, foundation bolts, nuts and washers, alignment of pump and motor, grouting, vibration control arrangement, making all mechanical and electrical connections, complete with RCC foundation as per OEM recommendation shuttering if required, curing and finishing, complete with trial run, testing to full load conditions, and commissioning to the entire satisfaction of Engineer-in-Charge including Dismantling of existing electric/ diesel driven old unserviceable pump set from its installed position, including disconnection of electrical wiring, suction and delivery pipe connections, removal of foundation bolts, lifting, handling and transportation and handing over the dismantled pump set to the MES store yard, complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Supply, installation, testing, and commissioning of electric-driven vertical turbine pump with bronze impeller, TEFC IE2 Solid shaft NFLP IP55 Motor 40 HP, gland packing type sealing arrangement suitable for 3-phase, 415 V, 50 Hz motor, 30 m head, 70,000 GPH discharge, self water lubrication type pump, including ERW heavy duty column pipes, bowl assembly, shafting, thrust bearings, suction strainer, alignment, coupling, common MS base plate, foundation bolts, nuts and washers, alignment of pump and motor, grouting, vibration control arrangement, making all mechanical and electrical connections, complete with PCC foundation as per OEM recommendation shuttering if required, curing and finishing, complete with trial run, testing to full load conditions, and commissioning to the entire satisfaction of Engineer-in-Charge, including Dismantling of existing electric/ diesel driven old unserviceable pump set from its installed position including disconnection of electrical wiring, suction and delivery pipe connections, removal of foundation bolts, lifting, handling and transportation and handing over the dismantled pump set to the MES store yard, complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Supply, installation, testing and commissioning of radiator-cooled diesel engine driven horizontal split-casing multistage centrifugal pump having CI casing, CI impeller and CI shaft, suitable for discharge of 90 litres per second against a total head of 70 metres, complete with gland packing type sealing arrangement, suitable diesel engine confirming to latest CPCB norms with radiator cooling system including coolant, fuel tank of adequate capacity with complete fuel system, starting system with battery and battery charger, engine control panel with indications, protections, alarms and safety shutdowns, common base frame with flexible coupling and proper alignment, vibration isolation arrangement, priming arrangement, initial lubrication, and all accessories required for satisfactory operation, including design and construction of RCC foundation as per OEM recommendations with shuttering if required, curing and finishing, complete in all respects, including trial run, testing up to full load conditions and commissioning, to the entire satisfaction of the Engineer-in-Charge including Dismantling of existing electric/ diesel driven old unserviceable pump set from its installed position, including disconnection of electrical wiring, suction and delivery pipe connections, removal of foundation bolts, lifting, handling and transportation and handing over the dismantled pump set to the MES store yard, complete all as specified and as directed by Engineer-in-Charge. |
| 4 | Supply, laying in trenches or fixing on wall or passing through pipe or in cable ducts, XLPE insulated PVC screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of 3.5 core 50 sqmm size cable complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Supply, laying in trenches or fixing on wall or passing through pipe or in cable ducts, XLPE insulated PVC screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of 3.5 core 70 sqmm size cable complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Supply and install in repair including testing and commissioning of LT panel indoor type totally enclosed with front and rear opening hinged doors and raised platform of suitable sizes weather dust vermin proof made out of 2.0 mm thick CRCA sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 250 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accomodate the following items including supply and fix following items :-(a) MCCB 160 Amps 4 pole 35 KA - adjustable type with extended terminal (incoming) -01 Nos(b) MCCB 125 Amps 4 pole 25 KA - adjustable type with extended terminal (incoming) - 02 Nos(c) Star delta fully sutomatic startere 50 HP with in built contactor and relay - 02 Nos(d) MCB TPN 40 Amps 4 pole 16 KA - 2 Nos(e) Multifunctional meter (KWH, Voltage,Ampere and frequency)-03 set(f) RYB indicator lamp-03 set |
| 7 | Supply and install in repair including testing and commissioning of LT panel indoor type totally enclosed with front and rear opening hinged doors and raised platform of suitable sizes weather dust vermin proof made out of 2.0 mm thick CRCA sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 250 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accomodate the following items including supply and fix following items :-(a) MCCB 125 Amps 4 pole 35 KA - adjustable type with extended terminal (incoming) -01 Nos(b) MCCB 100 Amps 4 pole 25 KA - adjustable type with extended terminal (incoming) - 02 Nos(c) Star delta fully sutomatic startere 40 HP with in built contactor and relay - 02 Nos(d) MCB TPN 40 Amps 4 pole 16 KA - 2 Nos(e) Multifunctional meter (KWH, Voltage,Ampere and frequency)-03 set(f) RYB indicator lamp-03 set |
| 8 | Supply & laying MS ERW pipe of 200 mm dia heavy grade for inserting in position, making leak proof joints including fittings, welding and testing the pipe line for leakage, including painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking down of old unserviceable existing pipe complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply & laying MS ERW pipe of 150 mm dia heavy grade for inserting in position, making leak proof joints including fittings, welding and testing the pipe line for leakage, including painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking down of old unserviceable existing pipe complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply & laying MS ERW pipe of 100 mm dia heavy grade for inserting in position, making leak proof joints including fittings, welding and testing the pipe line for leakage, including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete including taking down of old unserviceable existing pipe complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply and fix in replacement of CI non return valve of size 200 mm dia with by pass arrangement and necessary rubber gasket, nuts, bolts, and washers etc., complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Supply and fix in replacement of CI non return valve of size 150 mm dia with by pass arrangement and necessary rubber gasket, nuts, bolts, and washers etc., complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Supply and fix in replacement of CI non return valve of size 100 mm dia with by pass arrangement and necessary rubber gasket, nuts, bolts, and washers etc., complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Supply and fix in replacement of CI foot valve ball type of size 200 mm dia heavy duty with necessary rubber gasket, bolts, nuts and washers complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply and fix in replacement of CI foot valve ball type of size150 mm dia heavy duty with necessary rubber gasket, bolts, nuts and washers complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply and fix in replacement of CI sluice valves, of size 150 mm dia, PN 1.6, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints nuts, bolts washers and rubber gasket etc. complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Supply and fix in replacement of CI sluice valves, of size 100 mm dia, PN 1.6, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints nuts, bolts washers and rubber gasket etc. complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Supply and fixing on wall or passing through pipe or in cable ducts connecting PVC insulated and PVC round sheathed copper conductor industrial cable of size 50 sqmm 3 core, 1100 Volt complete including taking down of old unserviceable cable complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Supply and fixing on wall or passing through pipe or in cable ducts connecting PVC insulated and PVC round sheathed copper conductor industrial cable of size 70 sqmm 3 core, 1100 Volt complete including taking down of old unserviceable cable complete all as specified and as directed by Engineer-in-Charge. |
| 20 | Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. including taking down of existing earthing set complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |