|
| 1 | 45 watt LED Street Light Make: Surya/Bajaj, Note: Rates are without GST1 Lamp Operation Mode ON, OFF Light Source High Power SMD LED )= 1W2 For Smart LED Light Lamp Operation Mode LED ON, OFFand DIM Light Source High Power SMD LED )= 1W Usage Hours Dusk to dawn (12 hours)3 Life span of LEDs used in the Luminaire shall be 0 ) 50000 hours. l L704 Color rendering index (CRI) of the LEDS used in the luminaire shall be )_ 705 LED chip efficiency shall be more than 135 Lumens/watt at Tj 85° C (Manufacturer shall submit the proof - LED Technical Data Sheet to be submitted) System Efficiency ) 120 L/w6 Junction Temperature (T) should be (85°C7 Photo Biological Safety Report for the LEDs as per IEC 62471 and blue light assessment as per IEC/TR 62778-Ed. 1.08 Color temperature of the luminaire shall be in the range of nominal 5000K to 6000K (CCT as per ANSI) 9 The distribution of luminaries` illumination (control of distribution) shall be based on the type of road as per BIS standard 151944 refer table from NLC for Road category.10 Power factor ) 0.95% with APFC11 System Shall be )120lumen/watt. System Efficacy lumen output supported by LM79 (lumen/watt) report shall be submitted.12 CRI of )_70 luminaries 13 Light Uniformity Ratio (Emin/Eavg) shall be as per IS 1944 based on the category of road14 The luminaries` light output lumen) shall be constant. The voltage variations/fluctuations in the specified voltage range shall not impinge upon the lumen it produces. Maximum 2 % allowed throughout in the input operating voltage range.15 Driver shall be fully potted and should have a power factor )=0.95, and THD ( 10% with inbuilt surge protection of internal 4KV/amp: extremal 10kV. The driver should be suitable for an operating voltage range of 140- 270V AC, cut-off at (300V AC, and self-restore. The driver should suntain up to 8 hours al 440 V AC.16 Total Harmonic Distortion: 16 ( 10% THD Test Method IEC:610003-217 LED Drive current: up to or ( 1000 mA 18 LED driver efficiency: )_85%19 Luminaire Body Temp should not exceed 30 deg. C from ambient (45 deg.c) with tolerance of 10deg.C after 24 Hrs20 Heat dissipation/heat sink: Well-designed thermal management system with defined heat sink21 The luminaries shall be single piece pressure die cast aluminium housing with corrosion-resistant powder coating conforming to ensure IP 66, and IK 07 protection22 Luminaire shall have a separate optical and driver compartment.23 The luminaries shall be built in such a way that it can withstand a wind speed of 150Kmph. The manufacturer shall furnish NABL accredited lab report supporting the same. (Impact resistances-IK(07)24 Fixture Cover `Non-Yellowing polycarbonate optics cover` or UV resistance Non Yellowing polycarbonate / PMMA toughened optics cover be required with proper 1P66 provision. The lens should be mechanically (fixed, and fixing by glue is not acceptable25 Frequency: 50Hz plus /-3%26 Operating temperature: Range: -10C to plus 50C27 Protections: IP65, Surge protection of 10 kV, IEC61000-4-528 Working humidity: Preferred 100%, and not less than 95% RH29 `Conformation standards of luminaries (Test reports of luminaries): The luminaries should conform to IEC 60598/IS:10322 The luminaries should be tested as per IEC 60598-2-3:2002/ IS:10322 Part 5 Sec-3 standards, and the following test reports should be submitted: Heat Resistance Test, Thermal Test, Ingress Protection Test, Drop TestElectrical / Insulation Resistance Test, Endurance Test, Humidity Test, Photometry Test (LM79 report), Vibration Test`30 Finish: Aesthetically designed housing with grey color corrosion-resistant polyester powder coating31 Luminaries configuration/ technical requirement: Side entry type. Shall consist of separate optical and control gear compartments. It should be easily replaceable in the fleld condition.32 Compliance: ROHS /CE/ERTL/ERDI 33 Surge Protection: External Surge protection of 10kV/ 5 KA to be separately installed with each fixture34 All the types of test/specification of LED STRE?? LIGHTS mentioned in the above table from point number 1 to 33 to be supported.35 All luminaires should be connected to earth potential by yellow-green wire as per IS:3043 |
| 2 | 90 watt LED Street Light Make: Surya/Bajaj, Note: Rates are without GST1 Lamp Operation Mode ON, OFF Light Source High Power SMD LED )= 1W2 For Smart LED Light Lamp Operation Mode LED ON, OFFand DIM Light Source High Power SMD LED )= 1W Usage Hours Dusk to dawn (12 hours)3 Life span of LEDs used in the Luminaire shall be 0 ) 50000 hours. l L704 Color rendering index (CRI) of the LEDS used in the luminaire shall be )_ 705 LED chip efficiency shall be more than 135 Lumens/watt at Tj 85° C (Manufacturer shall submit the proof - LED Technical Data Sheet to be submitted) System Efficiency ) 120 L/w6 Junction Temperature (T) should be (85°C7 Photo Biological Safety Report for the LEDs as per IEC 62471 and blue light assessment as per IEC/TR 62778-Ed. 1.08 Color temperature of the luminaire shall be in the range of nominal 5000K to 6000K (CCT as per ANSI) 9 The distribution of luminaries` illumination (control of distribution) shall be based on the type of road as per BIS standard 151944 refer table from NLC for Road category.10 Power factor ) 0.95% with APFC11 System Shall be )120lumen/watt. System Efficacy lumen output supported by LM79 (lumen/watt) report shall be submitted.12 CRI of )_70 luminaries 13 Light Uniformity Ratio (Emin/Eavg) shall be as per IS 1944 based on the category of road14 The luminaries` light output lumen) shall be constant. The voltage variations/fluctuations in the specified voltage range shall not impinge upon the lumen it produces. Maximum 2 % allowed throughout in the input operating voltage range.15 Driver shall be fully potted and should have a power factor )=0.95, and THD ( 10% with inbuilt surge protection of internal 4KV/amp: extremal 10kV. The driver should be suitable for an operating voltage range of 140- 270V AC, cut-off at (300V AC, and self-restore. The driver should suntain up to 8 hours al 440 V AC.16 Total Harmonic Distortion: 16 ( 10% THD Test Method IEC:610003-217 LED Drive current: up to or ( 1000 mA 18 LED driver efficiency: )_85%19 Luminaire Body Temp should not exceed 30 deg. C from ambient (45 deg.c) with tolerance of 10deg.C after 24 Hrs20 Heat dissipation/heat sink: Well-designed thermal management system with defined heat sink21 The luminaries shall be single piece pressure die cast aluminium housing with corrosion-resistant powder coating conforming to ensure IP 66, and IK 07 protection22 Luminaire shall have a separate optical and driver compartment.23 The luminaries shall be built in such a way that it can withstand a wind speed of 150Kmph. The manufacturer shall furnish NABL accredited lab report supporting the same. (Impact resistances-IK(07)24 Fixture Cover `Non-Yellowing polycarbonate optics cover` or UV resistance Non Yellowing polycarbonate / PMMA toughened optics cover be required with proper 1P66 provision. The lens should be mechanically (fixed, and fixing by glue is not acceptable25 Frequency: 50Hz plus /-3%26 Operating temperature: Range: -10C to plus 50C27 Protections: IP65, Surge protection of 10 kV, IEC61000-4-528 Working humidity: Preferred 100%, and not less than 95% RH29 `Conformation standards of luminaries (Test reports of luminaries): The luminaries should conform to IEC 60598/IS:10322 The luminaries should be tested as per IEC 60598-2-3:2002/ IS:10322 Part 5 Sec-3 standards, and the following test reports should be submitted: Heat Resistance Test, Thermal Test, Ingress Protection Test, Drop TestElectrical / Insulation Resistance Test, Endurance Test, Humidity Test, Photometry Test (LM79 report), Vibration Test`30 Finish: Aesthetically designed housing with grey color corrosion-resistant polyester powder coating31 Luminaries configuration/ technical requirement: Side entry type. Shall consist of separate optical and control gear compartments. It should be easily replaceable in the fleld condition.32 Compliance: ROHS /CE/ERTL/ERDI 33 Surge Protection: External Surge protection of 10kV/ 5 KA to be separately installed with each fixture34 All the types of test/specification of LED STRE?? LIGHTS mentioned in the above table from point number 1 to 33 to be supported.35 All luminaires should be connected to earth potential by yellow-green wire as per IS:3043 |
| 3 | 120 watt LED Street Light Make: Surya/Bajaj, Note: Rates are without GST1 Lamp Operation Mode ON, OFF Light Source High Power SMD LED )= 1W2 For Smart LED Light Lamp Operation Mode LED ON, OFFand DIM Light Source High Power SMD LED )= 1W Usage Hours Dusk to dawn (12 hours)3 Life span of LEDs used in the Luminaire shall be 0 ) 50000 hours. l L704 Color rendering index (CRI) of the LEDS used in the luminaire shall be )_ 705 LED chip efficiency shall be more than 135 Lumens/watt at Tj 85° C (Manufacturer shall submit the proof - LED Technical Data Sheet to be submitted) System Efficiency ) 120 L/w6 Junction Temperature (T) should be (85°C7 Photo Biological Safety Report for the LEDs as per IEC 62471 and blue light assessment as per IEC/TR 62778-Ed. 1.08 Color temperature of the luminaire shall be in the range of nominal 5000K to 6000K (CCT as per ANSI) 9 The distribution of luminaries` illumination (control of distribution) shall be based on the type of road as per BIS standard 151944 refer table from NLC for Road category.10 Power factor ) 0.95% with APFC11 System Shall be )120lumen/watt. System Efficacy lumen output supported by LM79 (lumen/watt) report shall be submitted.12 CRI of )_70 luminaries 13 Light Uniformity Ratio (Emin/Eavg) shall be as per IS 1944 based on the category of road14 The luminaries` light output lumen) shall be constant. The voltage variations/fluctuations in the specified voltage range shall not impinge upon the lumen it produces. Maximum 2 % allowed throughout in the input operating voltage range.15 Driver shall be fully potted and should have a power factor )=0.95, and THD ( 10% with inbuilt surge protection of internal 4KV/amp: extremal 10kV. The driver should be suitable for an operating voltage range of 140- 270V AC, cut-off at (300V AC, and self-restore. The driver should suntain up to 8 hours al 440 V AC.16 Total Harmonic Distortion: 16 ( 10% THD Test Method IEC:610003-217 LED Drive current: up to or ( 1000 mA 18 LED driver efficiency: )_85%19 Luminaire Body Temp should not exceed 30 deg. C from ambient (45 deg.c) with tolerance of 10deg.C after 24 Hrs20 Heat dissipation/heat sink: Well-designed thermal management system with defined heat sink21 The luminaries shall be single piece pressure die cast aluminium housing with corrosion-resistant powder coating conforming to ensure IP 66, and IK 07 protection22 Luminaire shall have a separate optical and driver compartment.23 The luminaries shall be built in such a way that it can withstand a wind speed of 150Kmph. The manufacturer shall furnish NABL accredited lab report supporting the same. (Impact resistances-IK(07)24 Fixture Cover `Non-Yellowing polycarbonate optics cover` or UV resistance Non Yellowing polycarbonate / PMMA toughened optics cover be required with proper 1P66 provision. The lens should be mechanically (fixed, and fixing by glue is not acceptable25 Frequency: 50Hz plus /-3%26 Operating temperature: Range: -10C to plus 50C27 Protections: IP65, Surge protection of 10 kV, IEC61000-4-528 Working humidity: Preferred 100%, and not less than 95% RH29 `Conformation standards of luminaries (Test reports of luminaries): The luminaries should conform to IEC 60598/IS:10322 The luminaries should be tested as per IEC 60598-2-3:2002/ IS:10322 Part 5 Sec-3 standards, and the following test reports should be submitted: Heat Resistance Test, Thermal Test, Ingress Protection Test, Drop TestElectrical / Insulation Resistance Test, Endurance Test, Humidity Test, Photometry Test (LM79 report), Vibration Test`30 Finish: Aesthetically designed housing with grey color corrosion-resistant polyester powder coating31 Luminaries configuration/ technical requirement: Side entry type. Shall consist of separate optical and control gear compartments. It should be easily replaceable in the fleld condition.32 Compliance: ROHS /CE/ERTL/ERDI 33 Surge Protection: External Surge protection of 10kV/ 5 KA to be separately installed with each fixture34 All the types of test/specification of LED STRE?? LIGHTS mentioned in the above table from point number 1 to 33 to be supported.35 All luminaires should be connected to earth potential by yellow-green wire as per IS:3043 |
| 4 | 200 watt LED Street Light Make: Surya/Bajaj, Note: Rates are without GST1 Lamp Operation Mode ON, OFF Light Source High Power SMD LED )= 1W2 For Smart LED Light Lamp Operation Mode LED ON, OFFand DIM Light Source High Power SMD LED )= 1W Usage Hours Dusk to dawn (12 hours)3 Life span of LEDs used in the Luminaire shall be 0 ) 50000 hours. l L704 Color rendering index (CRI) of the LEDS used in the luminaire shall be )_ 705 LED chip efficiency shall be more than 135 Lumens/watt at Tj 85° C (Manufacturer shall submit the proof - LED Technical Data Sheet to be submitted) System Efficiency ) 120 L/w6 Junction Temperature (T) should be (85°C7 Photo Biological Safety Report for the LEDs as per IEC 62471 and blue light assessment as per IEC/TR 62778-Ed. 1.08 Color temperature of the luminaire shall be in the range of nominal 5000K to 6000K (CCT as per ANSI) 9 The distribution of luminaries` illumination (control of distribution) shall be based on the type of road as per BIS standard 151944 refer table from NLC for Road category.10 Power factor ) 0.95% with APFC11 System Shall be )120lumen/watt. System Efficacy lumen output supported by LM79 (lumen/watt) report shall be submitted.12 CRI of )_70 luminaries 13 Light Uniformity Ratio (Emin/Eavg) shall be as per IS 1944 based on the category of road14 The luminaries` light output lumen) shall be constant. The voltage variations/fluctuations in the specified voltage range shall not impinge upon the lumen it produces. Maximum 2 % allowed throughout in the input operating voltage range.15 Driver shall be fully potted and should have a power factor )=0.95, and THD ( 10% with inbuilt surge protection of internal 4KV/amp: extremal 10kV. The driver should be suitable for an operating voltage range of 140- 270V AC, cut-off at (300V AC, and self-restore. The driver should suntain up to 8 hours al 440 V AC.16 Total Harmonic Distortion: 16 ( 10% THD Test Method IEC:610003-217 LED Drive current: up to or ( 1000 mA 18 LED driver efficiency: )_85%19 Luminaire Body Temp should not exceed 30 deg. C from ambient (45 deg.c) with tolerance of 10deg.C after 24 Hrs20 Heat dissipation/heat sink: Well-designed thermal management system with defined heat sink21 The luminaries shall be single piece pressure die cast aluminium housing with corrosion-resistant powder coating conforming to ensure IP 66, and IK 07 protection22 Luminaire shall have a separate optical and driver compartment.23 The luminaries shall be built in such a way that it can withstand a wind speed of 150Kmph. The manufacturer shall furnish NABL accredited lab report supporting the same. (Impact resistances-IK(07)24 Fixture Cover `Non-Yellowing polycarbonate optics cover` or UV resistance Non Yellowing polycarbonate / PMMA toughened optics cover be required with proper 1P66 provision. The lens should be mechanically (fixed, and fixing by glue is not acceptable25 Frequency: 50Hz plus /-3%26 Operating temperature: Range: -10C to plus 50C27 Protections: IP65, Surge protection of 10 kV, IEC61000-4-528 Working humidity: Preferred 100%, and not less than 95% RH29 `Conformation standards of luminaries (Test reports of luminaries): The luminaries should conform to IEC 60598/IS:10322 The luminaries should be tested as per IEC 60598-2-3:2002/ IS:10322 Part 5 Sec-3 standards, and the following test reports should be submitted: Heat Resistance Test, Thermal Test, Ingress Protection Test, Drop TestElectrical / Insulation Resistance Test, Endurance Test, Humidity Test, Photometry Test (LM79 report), Vibration Test`30 Finish: Aesthetically designed housing with grey color corrosion-resistant polyester powder coating31 Luminaries configuration/ technical requirement: Side entry type. Shall consist of separate optical and control gear compartments. It should be easily replaceable in the fleld condition.32 Compliance: ROHS /CE/ERTL/ERDI 33 Surge Protection: External Surge protection of 10kV/ 5 KA to be separately installed with each fixture34 All the types of test/specification of LED STRE?? LIGHTS mentioned in the above table from point number 1 to 33 to be supported.35 All luminaires should be connected to earth potential by yellow-green wire as per IS:3043 Please Enable Macros to View BoQ information |