|
| 1 | Providing and fixing minimum size 100 feet x 200 feet water proof and fire proof Steel Structure/ Aluminum German Hanger Tent with vertical posts, truss/arch system purlins, horizontal and inclined bracing properly designed as structurally safe including erection, fixing in safe manner and covering on top and sides with special waterproof cloth of minimum 800 GSM high tensile and fire proof complete as required with fabric masking on side and back covering as per approved design, colour all complete. Height of structure should be suitable to accommodate lights, sound truss of height minimum 20 feet and span of 100 feet as per approved design all complete. No internal poles; perimeter ballast/anchorage engineered to resist local wind as per applicable Indian standards (submit structural stability certificate by Chartered Engineer). |
| 2 | Providing and fixing of Roof covering inside German Hanger Tent with approved design (with 2 approved colours cloth/crepe material) inside the German Hangar Tent on both sides of Truss. |
| 3 | Providing and fixing covering of side walls of German Hangar Tent with Cloth drapes of approved colours. |
| 4 | Providing and fixing minimum size 75 feet x 75 feet and 40 feet x 80 feet with Steel/Aluminum Structure Pandal for Buffet with vertical posts, horizontal posts and inclined bracing properly designed as structurally safe including erection, fixing in safe manner, and covering on top and sides with cloth as required with fabric masking on side and back covering as per approved design, colour all complete. Height of structure should be suitable to accommodate lights, with minimum height of 10 feet and span of 75 feet and 40 feet for two Tents. |
| 5 | Providing and fixing Stage fully carpeted (New carpet) duly supported on structurally safe scaffolding with required bracing and appropriate wooden top in perfect line and level. The wooden top should not be broken, uneven, and duly fixed to the support system. The whole system should be tested and certified as safe for holding cultural events. Minimum Size of stage will be 24 feet x 40 feet with one Ramp along with Carpet and side railing in aspect ratio 1: 12 of minimum 4 feet x 24 feet as per functional requirement. Stage shall be at minimum 5 feet height with masking all around the stage as per approved design. Stage shall be provided with minimum two steel staircases and one ramp fixed on platform of 3-4 feet height with SS Railing of minimum 4 feet width duly fixed in line and level with stage duly carpeted along with nosing at corner and profile. The tread of the staircases should have wooden top properly secured in position. |
| 6 | Providing and Fixing Outside the German Hanger, ≥18,000 sq ft of view-cutters (new) with masking/supports to screen BOH corridors, generator enclosures, waste holding, service doors and green-room access. All fixing methods shall be safe for guest movement, and the Vendor shall ensure that no nails, pins, metal pieces, or tools are left behind at any stage. Additionally, a continuous stretch of single‑used carpet (colour to be approved by DLCSUPVA, Rohtak) shall be laid from the University Guest House to the Convocation Tent and across the internal lobby areas, covering approximately 12,000 sq ft, to provide clean, uniform, and safe pedestrian pathways throughout the approach and entry zones. |
| 7 | Providing and fixing two nos. minimum size 20 feet x 20 feet and minimum height 10 feet for Robing Pandal of Steel/aluminium pipe structure with water Proof cloth covering on top and sides |
| 8 | Providing Steel chair with cushion and White Cover. |
| 9 | Providing and laying of Red Carpet in passage (of 5’x30’ size) |
| 10 | Providing and laying of Carpet (Green/Red colour as per requirement) in German Hanger Tent and Pandal for Buffet (100x200/75x75/40x80) |
| 11 | Providing and fixing of Podium/Lecture Stand for two persons on Main Stage with proper Mic and Sound System and Reading Lights. |
| 12 | Providing 2 Line VIP, Sofa 2/3-seater with white cover |
| 13 | Providing Center Table with cover for VVIP/VIP |
| 14 | Providing (50 each), (a) Flag Card with stand (b) Name Plates for VVIPs/VIPs |
| 15 | Providing Lighting on Stage and German Hanger Tent with a series of warm‑white, moderate‑sized chandeliers (Approx 15) shall be suspended along the central pathway to create a balanced and aesthetically enhanced ceiling treatment as approved by DLCSUPVA, Rohtak and Pandals for Buffet with earthing as per functional requirement with all necessary cabling and operating person/s and technician/s |
| 16 | Providing Round Table (Four-seater) complete with white cover |
| 17 | Providing White Marquee (Pagoda) Green Rooms of minimum size 05 Mtr including lighting, with sofa sets 01 No., Center Table-1 No., Mirror - 01No. Chair-5 Nos. with carpet etc. |
| 18 | Providing Steel Barricading of minimum 1m height with cross bracings |
| 19 | Providing Standard Queue Manager Posts of minimum 1m height along with belt |
| 20 | Providing Wooden Table with covers, for German Hanger Tent/Pandal for Buffet |
| 21 | Providing Bouquets and Decoration at Main Stage and inside German Hanger Tent, Entrance Gate of German Hanger Tent, University Main Gates including plywood/Steel gate/structure of approved design and University Guest House with good quality flowers of multiple varieties and ashoka leaves, rangoli with exotic cut flowers and Flower Pots with good quality flowers of multiple varieties (As per requirement of the University). |
| 22 | Provide, design, fabricate, and install welcome gates at entry points, consisting of one box‑type gate of 20 ft × 15 ft and another of 25 ft × 20 ft, with designs to be submitted and approved by DLCSUPVA, Rohtak to fabrication. A main decorative gate (Approx 40’ wide x 15 ft) shall be installed at the German Hangar entrance, incorporating truss structures, cloth decoration, and branding elements strictly as approved by DLCSUPVA, Rohtak. All materials, colours, proportions, and visual treatments must conform to DLCSUPVA’S, branding and aesthetic standards. Branding elements inside the hangar and all directional signage across the campus shall be installed only after obtaining design approval from DLCSUPVA, Rohtak, with samples to be presented in advance. |
| 23 | Provide, design, fabricate, supply, and install a comprehensive set of signages across the venue, including but not limited to entry arrows, directional signage, seating block identifiers, VIP/student/parent seating markers, green-room indicators, reception and BOH-only signage, male and female washroom signs, handwash points, used-plates collection points, no-smoking/open-flame warnings, emergency exit and fire-exit signage, assembly points, photography-area markers, PHC/first-aid direction, parking signs, all food-area signage and counter labels, waste-segregation indicators, and *Robing Room (Male/Female)* signage for graduating students. This list is indicative and not exhaustive, and the Service Provider shall provide any additional signages required for navigation, safety, branding, crowd management, or event operations, as directed by DLCSUPVA, Rohtak, without any additional cost. All designs and samples must be submitted and installed only after approval from DLCSUPVA, Rohtak. |
| 24 | Providing and fixing of LED Screens of Minimum size 8 Feet x12 Feet in German Hanger Tent/Outside (As per requirement of the University) with suitable arrangement for indoor and outdoor use in daylight with high level of brightness suitable for live video display weatherproof (IP65), High definition, P3/3.9(outdoor) or better, 140-degree view angle with processor vx4/6 with laptop and suitable wiring as per requirement of Centre Console and operating person/s and technician/s |
| 25 | Providing of Plasma TVs of suitable size for Main Stage with operating person/s and technician/s |
| 26 | Providing and fixing of Mike s & good quality sound systems including PA system with speakers and all accessories for German Hanger Tent and Main Stage and operating person/s and technician/s As required (Rate per set) (Minimum 5 sets) |
| 27 | Providing of 4K Video recording and live projection on LED Screens with TRIPOD for Video recording /projection, mixer, online editing setup and three video cameras to record and project from atleast three angles of all venue along with Camera persons and required technician/s. Fully recorded coverage of all venue must be provided by the firm in hard disk (4K Resolution) to the DLCSUPVA after the completion of Convocation event. |
| 28 | Arrangement of Genset 125 KVA compliant with CPCB 4+ of suitable capacity to cover load of AudioVideo and Stage Lighting separately (01set each separately for Audio Video, LED Screens and Lighting) (with acoustic enclosure along with operator and diesel for running per day as required including required cable) and operating person/s and technician/s |
| 29 | Providing of Ups Power Backup System 3 Way for light sound and led for backup upto 30 min with all necessary cabling and operating person/s and technician/s |
| 30 | Providing and laying of Drinking water Dispenser (Hot & Cold) with RO water filled Jar- 20 Ltr. (sufficient quantity as per requirement) |
| 31 | Providing Portable Bio Toilet of minimum size 5 Feet x 5 Feet of VIP Standards |
| 32 | Providing of 50 Ton Tower (Standing) Air Conditioners for main stage and VIP Seating Sofa Rows with all necessary cabling and operating person/s and technician/s |
| 33 | Providing 25 Industrial Coolers for German Hanger Tent/Pandals for Buffet/Pandal for Robing |
| 34 | Providing Silent Fans with Pedestal for German Hanger Tent/Pandals for Buffet/Pandal for Robing |
| 35 | Silent Mist Fans with Pedestal for German Hanger Tent/Pandals for Buffet/Pandal for Robing |
| 36 | Providing and fixing jhalar lighting on Guest House, gate etc. as per functional requirement with all necessary cabling and operating person/s and technician/s |
| 37 | Providing and fixing carpeted superstructure tier stands in five steps with minimum 8inch step height for each tier for group photography capacity of 100 students, along with steps for entry and exit for each tier. Last row of tier stand to be protected from backside by two lines of pipes with cloth masking to avoid incidental falling of student at backside. Cloth used for masking of these two lines of pipe to be tied and stitched properly with pipe for strengthening Please Enable Macros to View BoQ information |