| 1 | M & L for preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and directed. |
| 2 | Repair to potholes any depth, not exc 1Sqm each including sweeping free from dust and mud or water scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25mm in depth, making good by filling in screened & graded road metal, watering and well ramming (including supply of road metal) complete all as specified and directed. |
| 3 | Scarifying or picking gravelled mecadam or bituminous macadam surface n exc 50mm deep in area not exc 400 Sqm complete all as specified and directed. |
| 4 | M&L for applying evenly a priming/ tack coat with bituminous primer (Paving bituminous VG -10) @ 5 kg per 10 Sqm over the preparing surfaces by mechanical sprayer complete all as specified and directed. |
| 5 | M&L for Premix bituminous, macadam laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less) using binder content 4% by weight of total mix (using paving bitumen VG -30 grade) including cement filler, mix in hot mix plant using design mix and laid and rolled and compacted to required camber and gradient with 8 to 10 tonne power road roller complete all as specified and directed. Note:- (a) Bituminous macadam shall be mixed in hot plant transported from plant to work site and laid/spread by means of mechanical paver.(b) Contractor shall quote his rate on this basis of binder as mentioned in above item if there is any variation in the actual binder content used in lower side, the rate shall be adjusted however no price adjustment shall be made if the binder content works out to more than as specified in Sch 'A' |
| 6 | M&L for bituminous premix semi dence asphaltic dence concrete 30mm thick consolidated thick with 5.5% binder content by weight of total mix laid by machanical paver, rolled and compacted to required camber and gradient with 8 to 10 tonne vibratory power road roller complete all as specified and directed. Note:- (a) Bituminous macadam shall be mixed in hot plant transported from plant to work site and laid/spread by means of mechanical paver.(b) Contractor shall quote his rate on this basis of binder as mentioned in above item if there is any variation in the actual binder content used in lower side, the rate shall be adjusted however no price adjustment shall be made if the binder content works out to more than as specified in Sch 'A' |
| 7 | M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. Make :-STP Limited ( Shalimark / ShaliMark W), SNI Infratech Pvt Ltd (ESN TRMP), Maruti Bitumen Pvt Ltd (MARUTI REFLO MARK) |
| 8 | Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc including removal of spoil etc complete from drain complete all as specified and directed. |
| 9 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed |
| 10 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed except Bricks( bricks retrived from item no 8 above shall be reused) |
| 11 | Taking down cement plaster on wall including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 12 | M&L for 15mm thick SmartCare ready mix plasterfor External surface is a specially designed ready to use cement based plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering on bricks, block, stone walls over a coat of acrylic polymer as well as concrete surfaces. complete all as specified and directed. |
| 13 | Providing, cement concreteType B1 1:2:4 (20 mmm graded stone aggregate) in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly or chamfered angles and throating complete all as specified and directed. |
| 14 | M & L for preparation of newly plastered surface of brick/concrete surfaces of any description over 10cm girth or width not otherwise described and applying two coats of synthetic enamel paint (any tint) over a coat of priming coat including one coat of putty etc. complete all as specified and directed. |
| 15 | Taking down of old precast interlocking paver block and chequered tiles of any size and shape any description and in any position complete all as specified and directed. |
| 16 | Demolition of cement concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 17 | M&L for 75mm thck PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 18 | M&L 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawn, drive ways or light traffic parking etc. of required strength thickness & size /shape made by table vibratory method using PU mould laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting, and proper embedding /laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 19 | Supply and fix factory made rubber moulded machine pressed coloured chequered cement concrete tiles 300mm x 300mm x 25mm thick (with grey cement and no pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 20 | Supply and fixing in repair cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions complete all as specified and directed. |
| 21 | S&F in repairs plastic speed bumb of ABS material speed breaker/rubber rumbler of size L- 250 mmxW-350 mmxH-50 mm fixed with metallic bolt of suitable size embedded in epoxy as per manufacturer's instruction complete all as specified and directed. |
| 22 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 300mm bore of pipe complete all as specified and directed. |
| 23 | M&L PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of 300mm bore reinforced cement concrete pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed |
| 24 | M&L for reinforced concrete pipe of 300 mm bore, class NP 3 with one collar per lenth of pipe, laid in trenches and jointed in cm 1:1 complete all as specified and directed. |
| 25 | Cutting into existing manholes for connecting new drains making good to pipes and rendering, cutting out existing benching for and forming, branch channel( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finish and reforming benching as required for 300 mm dia Np3 pipe complete all as specified and directed. |
| 26 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed. |
| 27 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. |
| 28 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Please Enable Macros to View BoQ information |