| 1 | M&L for plain cement concret 1:2:4 type B2 using 40 mm graded stone aggregate as in foundation /platform / for road repair & other works including demolition of PCC, any type & removal of debris outside MoD land complete all as specified and as directed . |
| 2 | S&F in repairs double flanged single door type swing check reflux (Non return) with by pass arrangement valve conforming to IS-5312 of size 150 mm including suitable size of nut bolts washer and gasket etc. complete all as specified and as directed . |
| 3 | All as per BOQ Serial item no. 2 above but 100 mm complete all as specified and as directed . |
| 4 | All as per BOQ Serial item no. 2 above but 80 mm complete all as specified and as directed . |
| 5 | All as per BOQ Serial item no. 2 above but 50 mm complete all as specified and as directed . |
| 6 | Taking up Steel/GI water tubing and connection from trench/wall/floor , bore of pipe 150 mm complete all as specified and as directed . |
| 7 | All as per BOQ Serial item No 6 above but 100 mm dia complete all as specified and as directed . |
| 8 | All as per BOQ Serial item No 6 above but 80 mm dia complete all as specified and as directed . |
| 9 | All as per BOQ Serial item No 6 above but 50 mm dia complete all as specified and as directed . |
| 10 | All as per BOQ Serial item No 6 above but 40 mm dia complete all as specified and as directed . |
| 11 | All as per BOQ Serial item No 6 above but 25 mm dia complete all as specified and as directed . |
| 12 | All as per BOQ Serial item No 6 above but 20 mm dia complete all as specified and as directed . |
| 13 | All as per BOQ Serial item No 6 above but 15 mm dia complete all as specified and as directed . |
| 14 | M&L for 150mm GI water tubing, medium grade including all fittings (such as ends, Bend, elbows, unions, short pieces, connectors, back-nuts, diminishing pieces, caps, plugs and unions etc) and fixing with clips, wall hooks, wooden plugs, or laying in trenches , etc also for cutting ,screwing and waste and for making forged bends on piping as required . (Connectors shall be inserted,where required or directed) complete all as specified & directed. Note:- The rates also include cutting through walls, floors etc and their making good fixed complete laid in wall/ ceiling/ floor of 150 mm dia complete all as specified and as directed . |
| 15 | All as per BOQ Serial item No 14 above but 100 mm dia complete all as specified and as directed . |
| 16 | All as per BOQ Serial item No 14 above but 80 mm dia complete all as specified and as directed . |
| 17 | All as per BOQ Serial item No 14 above but 50 mm dia complete all as specified and as directed . |
| 18 | All as per BOQ Serial item No 14 above but 40 mm dia complete all as specified and as directed . |
| 19 | All as per BOQ Serial item No 14 above but 25 mm dia complete all as specified and as directed . |
| 20 | All as per BOQ Serial item No 14 above but 20 mm dia but laid in wall/ceiling/floor |
| 21 | All as per BOQ Serial item No 14 above but 15 mm dia but laid in wall/ceiling/floor complete all as specified and as directed . |
| 22 | M&L for Flange GI/MS pipes and fittings i.e Flange joint with rubber or fibre board gasket ,nuts, bolts after taking down old one etc complete all as specified and as directed of following sizes |
| 23 | 150 mm dia inner |
| 24 | 100 mm dia inner |
| 25 | 80 mm dia inner |
| 26 | M&L for M S Pipe of heavy grade including all fittings(including flange and nut bolt,Bend,Tee) required for used as a column pipe in bore well or laid in wall/ceiling/floor fixed complete all as specified and as directed of following size: |
| 27 | 150 mm inner dia |
| 28 | 100 mm inner dia |
| 29 | 80 mm inner dia |
| 30 | S&F CPVC pipe in trenches/wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessay fittings, like Elbow, Tee, Socket , Reducer, bushings , step over bends ,end caps, End plugs, etcand with CPVC solvents cement including taking down old pipe, any type complete all as specified and directed of following size : |
| 31 | size 100 mm inner dia |
| 32 | size 75 mm inner dia |
| 33 | size 50 mm inner dia |
| 34 | size 40 mm inner dia |
| 35 | size 32 mm inner dia |
| 36 | size 25 mm inner dia |
| 37 | size 20 mm inner dia |
| 38 | size 16 mm inner dia |
| 39 | S&F for repairs CPVC Ball Valve for CPVC pipe incl necessary fittings complete all specified and directed of following dia: - |
| 40 | 50 mm dia |
| 41 | 40 mm dia |
| 42 | 32 mm dia |
| 43 | 25 mm dia |
| 44 | 20 mm dia |
| 45 | 16 mm dia |
| 46 | M&L for GI/MS flange and joining by welding for following dia of pipe complete all as specified and as directed :- |
| 47 | 150 mm dia pipe |
| 48 | 100/ 80 mm dia pipe |
| 49 | M&L for CI/DI fittings incl Flange, Bend, Socket Bend, Spigot, Tail-piece, Flange Reducer, Mechanical joint etc complete all as specified and directed. |
| 50 | M&L for rubber or fibre board gasket nuts, bolts which used in Titan jointing after taking down old one etc complete all as specified and as directed of following sizes :- |
| 51 | dia 150 mm |
| 52 | dia 100 mm |
| 53 | M&L for rubber or fibre board gasket nuts, bolts which used in flange jointing after taking down old one etc complete all as specified and as directed of following sizes:- |
| 54 | dia 150 mm |
| 55 | dia 100 mm |
| 56 | dia 80 mm |
| 57 | M&L for run lead joint including taking down old joint complete all as specified and as directed of following size : - |
| 58 | CI pipe 150 mm dia |
| 59 | CI pipe 100 mm dia |
| 60 | CI pipe 80 mm dia |
| 61 | S&F in repairs Gun metal gate valve with iron wheel head, screwed down iron pipe complete all as specified and as directed of following size :- |
| 62 | dia 50 mm bore |
| 63 | dia 40 mm bore |
| 64 | dia 32 mm bore |
| 65 | dia 25 mm bore |
| 66 | dia 20 mm bore |
| 67 | of dia 15 mm bore |
| 68 | S&F in repairs 50 mm dia PVC ball valve high pressure with polythene float of following size complete all as specified and as directed . |
| 69 | 50 mm dia |
| 70 | 40 mm dia |
| 71 | 25 mm dia |
| 72 | 20 mm dia |
| 73 | 15 mm dia |
| 74 | S&F in repairs following dia butterfly valve made of S.G. iron disc including all accessories complete all as specified and as directed of following size:- |
| 75 | 150 mm dia |
| 76 | 100 mm dia |
| 77 | 80 mm dia |
| 78 | 65 mm dia |
| 79 | 50 mm dia |
| 80 | 40 mm dia |
| 81 | S&F in repairs, ISI marked following dia CI sluice valve both side flanged with SS spindle incl accessories complete all as specified and as directed of following size:- |
| 82 | 150 mm dia |
| 83 | 100 mm dia |
| 84 | 80 mm dia |
| 85 | S&F in repairs bronze vertical check valve complete all as specified and as directed of following size:- |
| 86 | 100 mm dia |
| 87 | 80 mm dia |
| 88 | 65 mm dia |
| 89 | 50 mm dia |
| 90 | 40 mm dia |
| 91 | 25 mm dia |
| 92 | S&F in repairs Foot Valve CI conforming to IS 4038 complete all as specified and as directed of following dia : |
| 93 | 150 mm dia |
| 94 | 100 mm dia |
| 95 | 80 mm dia |
| 96 | S&F in repairs Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of dia 15 mm complete all as specified and as directed . |
| 97 | S&F in repairs three layer ( inner antimicrobial,outer UV stabilizer) ISI marked, IS -15801, PP-R pipes SDR 11 (PN-10) and PP-Rplain fittings in trenches/wall/cellings or laying in floor complete including all accessories like socket, union, adopter, elbow, Core flange, tee, FTA, MTA etc complete all as specified and as directed of following dia : - |
| 98 | outer dia 110 mm |
| 99 | outer dia 90 mm |
| 100 | outer dia 63 mm |
| 101 | outer dia 50 mm |
| 102 | outer dia 40 mm |
| 103 | outer dia 32 mm |
| 104 | outer dia 25 mm |
| 105 | outer dia 20 mm |
| 106 | outer dia 16 mm |
| 107 | S&F in repairs UPVC pipe of pressure rating of 10 kgf/cm2 (as per schedule 40) laid in wall/Ceiling/floors/trenches including all necessay fittings, like Elbow, Tee, Socket , Reducer, bushings , step over bends ,end caps, End plugs, etcand with UPVC solvents cement complete all as specified and as directed of following sizes:- |
| 108 | Size 80 mm dia. |
| 109 | Size 65 mm dia |
| 110 | Size 50 mm dia |
| 111 | Size 40 mm dia |
| 112 | Size 32 mm dia |
| 113 | Size 25 mm dia. |
| 114 | Size 20 mm dia. |
| 115 | Size 15 mm dia. |
| 116 | S&F in repairs UPVC Ball Valve suitable for UPVC pipe incl necessary fittings complete all specified and directed of following sizes : |
| 117 | Size 80 mm dia. |
| 118 | Size 50 mm dia. |
| 119 | Size 40 mm dia. |
| 120 | Size 32 mm dia. |
| 121 | Size 25 mm dia. |
| 122 | Size 20 mm dia. |
| 123 | Size 15 mm dia. |
| 124 | M&L for Construction of measonary valve pit chamber with one full burnt brick (Sub class \\"B\\") in cement mortor (1:6) and 10 mm thick plastering inside & outside in CM 1:4 and PCC (1:4:8) type D-2 in foundation bed or size internally on 1000 mm x 1000 mm x 1000 mm with 3 mm thick MS sheet cover with locking arrangement hinged with 40 x 40 x 5 mm angle iron frame embeded in PCC (1:3:6) type C-1 etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces including earth work and all minor items complete all as specified and as directed . |
| 125 | All as per BOQ serial item no 41 above but internal size of pit 600 mm x 600 mm x 600 mm. |
| 126 | M&L for repirs to existing valve chamber by replacing MS cover plate 3 mm thickness & MS angle iron 40 X 40 X 5 mm size incl PCC Type B11:2:4 with 20 mm graded aggregrate for fixing of MS angle iron frame suitable for 1000 x 1000 x 1000 mm size valve chamber also inc with dismantling of old U/S MS plate & angle iron along with provision of locking arrangement and Handles complete all as specified and as directed . |
| 127 | M&L for repirs to existing valve chamber by replacing MS cover plate 3.15 mm thickness & MS angle iron 40 X 40 X 5 mm size incl PCC Type B11:2:4 with 20 mm graded aggregrate for fixing of MS angle iron frame suitable for 600 x 600 x 600 mm size valve chamber also inc with dismantling of old U/S MS plate & angle iron all as specified and directed along with provision of locking arrangement and Handles complete all as specified and as directed . |
| 128 | M&L for development of deep tube well by disel engine operared air compressor of suitable by means of upto air compressor of suitable by means of upto 350 CFM air comprerssor till sand /mud/slit fee water of portable quality of water is obtained , length of air hose pipe will be selected as fround requirement and to achieve a minium discharge of 15000 GPH including lowering and lifting of air pipe, complete all as specified and as directed at the location of II Line CHEC as vide:- |
| 129 | First day compressor runs |
| 130 | Second day compressure run |
| 131 | Third day till required discharge of water achieve-NOTE: (i) Compressor with connetced accessores and fuel shall be arranged by the contractor and at last 05 Kg raw caustic will be added in to each bore well before 24 hours for 1st & 2nd day only. Cost of which shall deem to be included in unit rate quoted.(ii) Pea grevel it required shall is deemed to be included be measured and paid included in quoted rate (iii) This item is consider for TWO bore well (iv) Taking out of pump-motor & coloum pipe consider seperately in relivent item. |
| 132 | S&F MS short piece of dia 200mm to 40mm of size 0.22 Rm to 0.60 Rm with both end flanged for filteration pipe line as per sample complete all as specified and as directed . |
| 133 | S&F MS bend of dia 80 to 200 mm , 90 degree with one end flanged suitable for filteration pipe line as per sample complete all as specified and as directed . |
| 134 | Excavation in trenches not exc 1.5m wide & not exc 1.5m in depth for lead joint /other leakage repair or foundation , getting out in any type of soil complete all as specified and as directed . |
| 135 | Excavation in trench in hard/dence soil not exc. 1.5 mtr width and n. exc 1.5 mtr in depth and getting out for lead joint /other leakage repair or foundation , getting out in any type soil complete all as specified and as directed . |
| 136 | Removing excavated material n exc. 1.65 Km and depositing inside the defence land where directed at a level above the starting point in any type of soil complete all as specified and as directed . |
| 137 | Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed. Please Enable Macros to View BoQ information |