| 1 | Running, maintenance & operation of Booster pumps, D.G. sets and street lighting, basement lighting, as per inventory terms & conditions attached. Note:- The agency shall provide the Tower Wagon in the contract period for maintenance of compound lightings of this housing within the qouted rate. No extra payment for the same will be entertained by this office . |
| 2 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 90 watt |
| 3 | Dismantling and repairing i/c S/R of following worn out parts of existing 25 HP clear water pump of kirloskar make suitable for operation on 415 volts , 3 phase ,50 hz ,AC supply i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd (i/c Rebate on dismantle materials):- (i) S/R of Pump shaft sleeve |
| 4 | (ii) S/R of Bal bearing |
| 5 | (iii) S/R of Gland plate |
| 6 | (iv) S/R of Gland guide bush |
| 7 | (v) S/R of Neck Ring |
| 8 | (v) S/R of Gland sleeve |
| 9 | Dismantling and rewinding i/c S/R of following worn out parts of existing 25 HP kirloskar make Induction motor(for clear water) i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd(i/c Rebate on dismantle materials):- (i) Rewinding of 25 HP motor |
| 10 | (ii) S/R of Connection plate i/c thembles |
| 11 | (iii) S/R of ball bearing |
| 12 | (iv) S/R of bearing bush |
| 13 | (v) Rotor balancing & turning |
| 14 | Supplying and replacement of damaged/burnt out starter by Automatic Star Delta Starter with D range Contactor & robusta (F Range),LR1D OLR & Electronic Star Delta Timer suitable for 25 HP contrifugal pump sets, 415 Volt, AC, 50H3, i/c dismantling the existing damaged/burnt out & connection testing etc completed as reqd.(i/c Rebate on dismantle materials) |
| 15 | Dismantling and rewinding/repairing of 5 HP capacity dewatering pump set suitable for 3 phase 415 volts 50 Hz AC supply and duly varnishing baking , to & fro cartage charges , reassembling and testing etc as regd. (I/c rebate on dismantle materials) |
| 16 | Supplying and replacement of damaged/burnt out Switch Disconnectors (Load Break Switches) by new one of Switch Disconnectors (Load Break Switches) with Sheet Steel Enclosure, 4-pole, 415 Volt, AC, 50H3, i/c dismantling the existing damaged/burnt out & connection, testing etc completed as reqd.(i/c Rebate on dismantle materials) |
| 17 | Supplying and replacement of following rusted flanges,bend,reducer,nipple i/c dismantling the existing rusted pipes & connection, testing etc completed as reqd.(I/c rebate on dismantle materials) a) S/R of 100 mm dia. GI bend |
| 18 | b) S/R of 100/80 mm dia GI reducer |
| 19 | c) S/R of 100 mm dia. GI Nipple--1 mtr length |
| 20 | d) S/R of 100 mm dia. Flange |
| 21 | e) S/R of 80 mm dia. Flange |
| 22 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.A ) 2x 25 sq. mm |
| 23 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A ) Up to 35 Sq mm |
| 24 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. A ) 3 x 1.5 sq.mm Please Enable Macros to View BoQ information |