| 1 | Earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches, drain not exceeding 1.5m in width 10 sq.m on plan including dressing of sides ramming of bottoms for all lead and lift including setting out the excavated soil & disposal of surplus soil with all lead including providing barricading danger lighting guarding as directed by departmental officer in all types strata comprising any of the materials such as soil, silt sand clay gravel moorum of all conglomerated laterite rock, soft rock fissured shattered decomposed rock or weathered rock and all such other materials as described under Appendix A to these specification either in full or in parts as the case may be adopting any approved method of methods as may be convenient or permitted inclusive of chiselling, wedging etc, blasting probhibited in all conglomerates as directed by the Engineer-incharge etc, complete. |
| 2 | Supplying at store or site of work Rigid PVC (SEL FIT) pipes for public water supply including Railway freight carting loading and unloading stacking transit insurance etc. complete Conforming to IS: 4985-2000 and bearing ISI mark Class 10 kg/cm2 |
| 3 | 90 mm dia |
| 4 | 140 mm dia |
| 5 | Supplying at store or site of work Rigid PVC (SEL FIT) pipes for public water supply including Railway freight carting loading and unloading stacking transit insurance etc. complete Conforming to IS: 4985-2000 and bearing ISI mark Class 6 kg/cm2 |
| 6 | 90 mm dia |
| 7 | Conveying carefully from stack at site 250m from both sides rolling and lowering in trenches laying true to line and level and perfect linking for joints for P.V.C / H.D.P.E complete in all respects as per the direction of the engineer in-charge |
| 8 | 90 mm OD |
| 9 | 140 mm OD |
| 10 | Jointing of rigid / SEL FIT PVC pipes by cleaning the pipe with solvent cement including the cost of solvent cement and hydraulic testing of joints etc. complete as per IS:7634-1975 Part 3 including hydraulic testing of joints as directed by the engineer in-charge. |
| 11 | 90 mm dia |
| 12 | 140 mm dia |
| 13 | Supply of rigid PVC fittings conforming to IS: 7834-1975 designed for precision and accuracy so as to join PVC pipes and other specials including railway freight carting loading and unloading and stacking etc. complete. |
| 14 | Elbow PN 10 (10kg/cm2) |
| 15 | 90 mm dia |
| 16 | Tee PN 6 (6kg/cm2) |
| 17 | 90 mm dia |
| 18 | Long bend 90 degree (6kg/cm2) |
| 19 | 90 mm dia |
| 20 | Service Saddle |
| 21 | 90x20 |
| 22 | Cutting the bituminous road for laying the pipeline in trenches for a width of 0.6m including labour, tools, etc. and disposing the excavated excess material from the trench to a distance of 1000 metres, including making level the trench surface by utilising the serviceable material to the level of the top surface of road, by compacting, watering ramming with rolling with road roller after completion of laying of pipe and refilling the trenches etc. complete as per the direction of engineer in charge. |
| 23 | By Mechanical Means |
| 24 | Rural Roads |
| 25 | Repairs and reinstatement to the road for trenches made by laying water supply pipeline, by removing the refilled material in the trench for the total depth of 0.40m and making good the road surface by providing laying rolling by road roller compacting for laterite soling 30cm thick, two layer of full grout of 50mm thick each as per specifications mentioned in item no 14086 of road GSR, complete as per the direction of the engineer in charge. |
| 26 | Rural road. |
| 27 | Refilling the pipeline/foundation trenches plinth sides foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 28 | Construction of masonry chamber 90 x 90 x100 cm inside in 40kg/sq. cm laterite masonry in neatly dressed stones complete with 23 cms wall thickness and in cement mortar 1:4 ( 1 cement : 4 coarse sand) for sluice valve of sizes 100 mm, 120 mm 150 mm and 200mm dia with necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand: 10 graded stone ballast 40 mm nominal size) and inside plastered with CM 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and chamber cover as specified below etc. all complete as per standard drawing . (rate is inclusive of rate earthwork excavation, cost of surface cover and all other materials and labour and as per details below) |
| 29 | with M.S. sheet cover with 12mm thick M.S. plate and frame of Angle iron 5050x6mm in 120 mm thick RCC slab cover in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone ballast 20 mm nominal size) |
| 30 | Construction of masonry chamber 60x60x75cm inside in laterite masonry in neatly dressed stones complete with 23 cms wall thickness and in cement mortar 1:4 ( 1 cement : 4 coarse sand) for sluice valves 50 to 80mm with necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand: 10 graded stone ballast 40 mm nominal size) and inside plastered with CM 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and chamber cover as specified below etc. all complete as per standard drawing . (rate is inclusive of rate earthwork excavation, cost of surface cover and all other materials and labour and as per details below) |
| 31 | with M.S. sheet cover with 12mm thick M.S. plate and frame of Angle iron 5050x6mm in 120 mm thick RCC slab cover in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone ballast 20 mm nominal size) |
| 32 | Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : |
| 33 | 20 mm nominal bore . |
| 34 | 80 mm nominal bore . |
| 35 | Providing and fixing non-return valve of approved quality : |
| 36 | 80 mm nominal bore |
| 37 | Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. C. I. single large orifice air valve(fig S2confirming to IS 14848/2000 with suitable connections as directed by Engineer -In- Charge for working pressure of 10kg/sq.cm. (Class B) |
| 38 | 25 mm dia |
| 39 | Fixing C.I. Single large orifice air valve of similar make with bronze ferrule at inlet screwed suitable to working pressure of 15kg/sq. cm for 12 mm to 20mm and 10kg/sq. cm for 25mm to 50mm, complete, as directed by the Engineer in-charge, of following sizes. |
| 40 | 25 mm dia |
| 41 | Making connection to individual 15mm /20mm/25mm G.I/ OD Blue PVC pipeline with existing distribution line of any diameter with saddle piece / and necessary pipe and specials required suitable to the distribution line with road cutting trenching refilling the same including the cost of labour and accessories etc. complete. as per the direction of Engineer -in- charge. Please Enable Macros to View BoQ information |