| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil completer all as specified and directed. |
| 2 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soft loose soil completer all as specified and directed. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc.25 cm thick in soft/loose soil ass as specified and directed. |
| 4 | M & L for Plain Cement concrete (1:4:8) Type D2 using in foundations, filling and mass concrete completer all as specified and directed. |
| 5 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for fair finished flat surface completer all as specified and directed. |
| 6 | S&F Steel work in tublar trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade ST-240 |
| 7 | M&L for 2mm green Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc completer all as specified and directed. |
| 8 | S & F for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering completer all as specified and directed. |
| 9 | M & L for hardcore of broken brick/stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, completer all as specified and directed. |
| 10 | M&L for Non skid coloured ceremic white tiles 7 to 8mm thk area of each tile exc 0.11 sqm but n exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to mortar.Laid over and including15 mm thick cement screed bed in CM 1:6 completer all as specified and directed. |
| 11 | Demolition of plain cement concrete in ground floors or above ground floor and paving n.exc 15 cm thickness (Below or above ground level) completer all as specified and directed. |
| 12 | Dismantling plain or corrugated steel sheeting, any guage, thickness incl nainital,AC Sheets or similar pattern as in roof coverings completer all as specified and directed. |
| 13 | S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as in roof covering including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, shape and colour complete all as specified and directed. |
| 14 | S&F pre-painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick as in roof covering or in eve board including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, shape and colour complete all as specified and directed. |
| 15 | S&F for 5 MM ACP Sheet (alluminium composite panel) sheet on wall/columns/roof required to fix with allum grid with any shape (back side framing) incl joint fillet with silicon and approved colour by GEcompleter all as specified and directed. |
| 16 | M&L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded aggregates as in plinth protection including finishing even and smooth without using extra cement completer all as specified and directed. |
| 17 | Excavation in trenches n.exceeding 1.50m wide and not exceeding 1.5 in depth for foundation etc and getting out as in soft/loose soil complete all as specified and as directed. |
| 18 | Removing/ compaction and refilling in site of surplus exacavated material (soil) to distance n.exc. 50m and up tototal distence of soft/loose soil complete all as specified and directed. |
| 19 | M&L for Boulder filling dry, handpacked tightly, as in wire crate apron bunds (Wire crate measured separately) complete all as specified and as directed. |
| 20 | M & L for Plain Cement concrete (1:4:8) Type D2 using in foundations, filling and mass concrete complete all as specified and as directed. |
| 21 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for fair finished flat surface complete all as specified and as directed. |
| 22 | M & L for reinforced cement concrete 1:2:4 type B-1, (using 12mm graded stone aggregate) (nominal mix) Foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete & form work shall be measured & paid under respective items) complete all as specified and as directed. |
| 23 | M&L for Formwork to faces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses,etc.; vertical or to batter completer all as specified and directed. |
| 24 | M & L for reinforced cement concrete 1:2:4 type B-1, (using 12mm graded stone aggregate) (nominal mix) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses etc & form work shall be measured & paid under respective items) .complete all as specified and as directed. |
| 25 | M &L TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 26 | Ditto item No 25 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. |
| 27 | Demolition of Brickwork/solid concrete block work built in Cement mortar complete all as specified and as directed. |
| 28 | M&L for 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate complete all as specified and directed. |
| 29 | M&L 75 mm PCC(1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor and filling as mass conc complete all as specified and as directed. |
| 30 | M&L for vitrified ceramic tiles (Paving dark shed, 10 mm thick(square /rectangular), polished, area of each tile n exc 0.36 sqm in floor etc , laid over 15 mm thick screed bed 1:6 ,set and jointed in neat cement slurry and pointed in white/coloured cement to match completer all as specified and directed. |
| 31 | S&F Steel work in tublar trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade ST-240 complete all as specified and as directed. |
| 32 | S&F GI tubes, medium grade galvanised, 40mm bore fixef in wall with all fitting complete all as specified and as directed. |
| 33 | Excavation in post holes (or similar holes) in any type of soil, each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus spoil to distance not exceeding 50 mtr and making good surface complete all as specified and directed. |
| 34 | M & L for Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface completer all as specified and directed. |
| 35 | M&L 100 mm PCC(1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor and filling as mass conc completer all as specified and directed. |
| 36 | M&L for Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, completer all as specified and directed. |
| 37 | M & L for Coloured Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing completer all as specified and directed. |
| 38 | M&L for non skid vitrified ceramic tiles (Paving dark shed, 10 mm thick(square /rectangular), polished, area of each tile n exc 0.36 sqm in floor etc , laid over 15 mm thick screed bed 1:6 ,set and jointed in neat cement slurry and pointed in white/coloured cement to match completer all as specified and directed. |
| 39 | M&L for Virified Ceramic tiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 complete all as specified and directed |
| 40 | M&L for rendering 15m thick on fair faces of brick or concrete work in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed . |
| 41 | M&L for applying two coat of cement base paint over a coat of newly plastering surface of wall incl preparation of new plaster/concrete surface complete all as specified and directed. |
| 42 | M & L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc completer all as specified and directed. |
| 43 | M&L Precast cement concrete block masonry with solid block exc 10 Cm in width with PCC, type C1 (1:3:6) using 20mm graded stone aggregate) and setting in CM 1:6 complete all as specified and directed. |
| 44 | M&L for cement concrete 1:3:6 type C2, 75mm thick as in plinth protection finished even and smooth with out using extra cement complete all as specified and directed. |
| 45 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, including 20 mm dia concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/Fan point controlled by one switch. |
| 46 | Description all as per Srl item No. 45 here in before but for socket outlet point 5 Amp on Independent board. |
| 47 | Description all as per Srl item No.45 here in before but for socket outlet point 5 Amp on same board. |
| 48 | Description all as per serial item No 45 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) completer all as specified and directed. |
| 49 | Supply and fixing modular switch 1 way 6 A module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 50 | Supply and fixing modular sockets 6A 2/3 pin combined 2 module, with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 51 | Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 52 | Supply and fixing modular switch 16A 1 module with frame and cover complete 230/250 Volts, 50 Hz , AC supply, ISI Marked, c with cover plate omplete all as specified and directed. |
| 53 | Supply and fixing LED batten fittings 1x 20 Watt complete including LED light driver, holder, LED lamp and connection up to ceiling rose with three core wire fixed to wall with 2 nos PVC block of suitable size including taking down old unserviceable one . |
| 54 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal completer all as specified and directed. |
| 55 | Supply and fixing LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket, clamps etc complete all as specified and directed. |
| 56 | Supply and fix in repairs MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. |
| 57 | Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed. |
| 58 | Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's complete all as specified and directed. |
| 59 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core Iincluding laying in trench or fixed on wall through clamps complete all as specified and as directed. |
| 60 | Excavation in trenches not exc 1.5 m wde and 1.5 m deep for taking out/laying of UG cable/GI pipe of any dismeter in soft/loose soil and getting out complete all as specified and directed. |
| 61 | Returning and filling including spreadking levelling watering and well ramming in layers not exc 25 cm thick soft/loose soil complete all as specified and directed. |
| 62 | Removing excavated material at a distance n exc 50m and deposited where directed at a level not exc 1.5 above the starting point for soft/lose soil complete all as specified and directed. |
| 63 | M & L for sand filing in treances for providing sand cushion for protection of UG cable complete all as specified and directed. |
| 64 | Supply and laying of sub class B bricks locally available alying perpendicular of UG cable complete all as specified and directed. Please Enable Macros to View BoQ information |