| 1 | Surface excavation averaging 15cm deep and n.exc 30cm deep and getting out in soft/loose soil complete all as specified and directed |
| 2 | Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole , laying of UG cables etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in hard/ dense soil complete all as specified and directed. |
| 3 | Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out in hard/ dense soil and removing surplus soil to a distance exceeding 500 m and making good surface. |
| 4 | Removing excavated surplus soil to a distance exc 250 mts but not exceeding 500mts . and depositing where directedcomplete all as directed. |
| 5 | M & L for Hard core of broken hard stone or boulders of guage not exceeding 63 mm , deposited spread as subbase to inter locking tiles in layers n.exc 15cm thick , watered & well rammed to true surface complete all as specified and directed. |
| 6 | M & L for PCC 1 :2 :4 type B2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed |
| 7 | Providing precast ce- ment concrete Type B1 1:2 :4 using 20 mm graded crushed stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry),string courses, copings. kneelers, apex stones, pier caps, columns, posts , boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets,etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match Set in cement mortar 1:4 complete all as directed. |
| 8 | Supply only Integral Water Proofing Compound (ISI Marked) of Make : CICO, Acco Proof, Impermo, Aqua flex as approved. |
| 9 | M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified |
| 10 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:4 complete all as specified & as directed. |
| 11 | Supply and fixing for 24 mm thick 100% solid WPC (Wood polymer composite) jali of required size comprising of virgin PVC resin of K Value 58-60 (Suspension Grade), Calcium carbonate and natural fibers (Wood powders/rice husk/wheat husk ) and Non toxic additives, made from extrusion Process WPC foam sheet single extruded (inner) with having minimum density not less than 650 kg/cbm manufactured an ISO 9001-2015 Certified company, having good screw holding capacity(screw Withdrawal strength of 2000N (face) &1100 N (edge),minimum compressive of 50 N/mm2, Modulus of elasticity 850 N/mm2 and resistance of spread of flame of class A category with property of being Termite/borer free. Water/Moisture Proof and Fire Retardant. WPC jali to be fixed with required size with necessary full body threaded star headed counter sunk SS screws or anchor Fastners. Material test certificate and authentication should be compulsory provided by the manufacturing Company. Complete all as per direction of Engineer in charge. |
| 12 | S&F for Automatic sliding door 12 mm thick toughned glass frameless door shutter exc 4.0 sqm but n exc 6.0 sqm (height of glass exc 2.0m but n exc 2.50 m) with itching including all fitting and fixtures operated with automatic electric sensor including in built locking/unlocking arrangement including necessary GI guide horizontal/ Vertical including remotes and receiver, push buttons etc including all misc accessories /fittings/fixtures required to smooth operation of door etc completed and as directed of make dorma/Ozone /equivalent ISI Mark. Note itching pattern as directed by EIC. Automatic sensor door having maintainace up to 18 month of all item/part required to smooth function. Note:(i) rate of item shall be inclusive of silicon filling if required and rubber brush in between fixed glass and slide glass to avoid any leakage of AC. (ii) rate of item shall be inclusive of glass work & Motor, No seperate payment to be done. (iii)Rate shall be inclusive of laser print IAF logo/unit logo and nomenclature of building all as specified and directed by Engr-in-charge. (iv)Rate shall be inclusive of all transportation handing and taxes etc completed and as directed. |
| 13 | S&F for structural glazing by one way toughened reflective glass 6 mm thick for outdoor use Openable and fixed to wall / cladding / windows in any geometrical pattern / shape of approved colour and brand (Make : Saint Gobin / Modi / Swastik equivalent as approved) including all material such as Stainless Steel section as approved by Engr-in-charge for fixing properly framing including scaffolding for working upto 10 mtr height.The glazing shall be fixed on SS frames / battens to the masonry / RCC walls / facias with necessary clamps, brackets and anchor fasteners. The total cost includes cost of SS frame, glass, clamps, weather sealents using silicon basket, forms, fixtures scaffolding and tools and plants or any other consumbles like fastenings strips, nuts, bolt, rivets, washers Sealent etc with all safety measure up to 10.00 m height etc completed all as specified and directed by Engr-in charge. (Note: Supply only Weight of Stainless steel Frame section Consider seperately) Please Enable Macros to View BoQ information |
| 14 | S&F for structural glazing by one way toughened reflective glass 6 mm thick for outdoor use Openable and fixed to wall / cladding / windows in any geometrical pattern / shape of approved colour and brand (Make : Saint Gobin / Modi / Swastik equivalent as approved) including all material such as Stainless Steel section as approved by Engr-in-charge for fixing properly framing including scaffolding for working upto 10 mtr height.The glazing shall be fixed on SS frames / battens to the masonry / RCC walls / facias with necessary clamps, brackets and anchor fasteners. The total cost includes cost of SS frame, glass, clamps, weather sealents using silicon basket, forms, fixtures scaffolding and tools and plants or any other consumbles like fastenings strips, nuts, bolt, rivets, washers Sealent etc with all safety measure up to 10.00 m height etc completed all as specified and directed by Engr-in charge. (Note: Supply only Weight of Stainless steel Frame section Consider seperately) Please Enable Macros to View BoQ information |