| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER CHILKA, INS CHILKA, KHURDA, ODISHA - 752 037 Name Of Work : REPAIR, REPLACEMENT AND MAINTENANCE OF BLDG SECURITY LIGHT, DBs, MCCBs AND SERVICE CONNECTION CABLES AT INS CHILKA UNDER GE CHILKA Contract No : GE/CHL/8182 OF 2025-26 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Supply and fix in repairs Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified. |
| 3 | Supply and fix in repairs Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 12 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified. |
| 4 | Supply and fix in repairs Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified. |
| 5 | Supply and fix in repairs Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified. |
| 6 | Supply and fixing in replacement of VTPN double door incoming for 100A MCCB 4 way MCCB and fitted with bus bar, neutral links and blanking plate, IP-56 complete all as specified. |
| 7 | S&F in replacement MCCB 4 pole 250 Amps,adujstable type capacity, Breaking capicity 36 kA, 415 Volts, 250 Amps complete all as specified. |
| 8 | S&F in replacement MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 100 Amps. complete all as specified. |
| 9 | S&F in replacement MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 63 Amps complete all as specified. |
| 10 | Supply and fix in replacement of MCB 6 to 32Amp, 240 Volt,SP, breaking capacity 10 KA 'C' series, as complete all as specified complete all as specified. |
| 11 | Supply and fix in replacement of MCB 32 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, as, complete all as specified complete all as specified. |
| 12 | Supply and fix in replacemen of MCB 63Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, as complete all as specified complete all as specified. |
| 13 | Supply and fix in replacement of MCB 40 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, as, complete all as specified. |
| 14 | Supply and fix in replacement of MCB 63Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, as, complete all as specified. |
| 15 | S&F in repairs Earthing complete with galvanised earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion. |
| 16 | S&F in repair for earth continuity fixed to wall on batten or reccs or chases or buried in ground or drawn in conduit/pipe or other indicated situation for loop earthing etc as required 4mm dia GI or steel earth wire complete all as specified. |
| 17 | Supply and fixing LED Bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete including taking down old unserceable light fitting all as specified and directed. |
| 18 | Supply and fixing in repair of GI pipe Bracket of 40 mm dia Medium grade pipe bend to shape of approx length 1.5 Mtr including 2 no. MS Clamp of flat iron size 40x6 mm complete with nut, bolt, washers all as specified and directed. |
| 19 | Supply and laying in replacement of XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm x 4 core including taking down existing cable complete all as specified.Make:- Finolex/ Gloster/ Polycab/Havells Note: The cost of thimbles/lugs and cable gland if incl in quoted rate and no extra payment will be maid for it. |
| 20 | Supply and layingin replacement of XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm x 4 core including taking down existing cable complete all as specified.Make:- Finolex/ Gloster/ Polycab/Havells Note: The cost of thimbles/lugs and cable gland if incl in quoted rate and no extra payment will be maid for it. |
| 21 | Excavation in trenches in soft/loose soil not exc.1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for laying of underground cableor inside substation for( making cable ducts & cable inside substation) complete all as specified. |
| 22 | Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick soil after repairing/jointing and laying and testing of cables complete all as specified |
| 23 | Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified. |
| 24 | Supply and fixing HDPE double wall pipe corugated pipe of size 63 mm X 50 mm Outer dia /internal dia for cable protection laid in trenches in lieu of sand/brick protection complete all as specified and directed. Make- Supreme / finolex/Prince/Astral. |
| 25 | supply and fix in repairs sub main wiring with two run of 10.0 Sq. mm PVC sheathed, copper conductor cable, 1100 Volt, FRLSH grade and one run of copper earth wire 10.0 Sq mm drawn through PVC casing and caping, complete all as specified. Note : Copper conductor 2 run and one run of copper earth wire along with PVC casing and caping shall be measured as one length. |
| 26 | supply and fix in repairs sub main wiring with two run of 10.0 Sq. mm PVC sheathed, copper conductor cable, 1100 Volt, FRLSH grade and one run of copper earth wire 10.0 Sq mm drawn through PVC casing and caping, complete all as specified. Note : Copper conductor 4 run and one run of copper earth wire along with PVC casing and caping shall be measured as one length. |
| 27 | Supply and fix in repair Cable end box 3 phase system TPN 4 way Horizontal e , as complete all as specified Make- Siemen/Legrand/L & T/HPL/C&S/Schneider ) |
| 28 | Supply and fix in repair Cable end box SPN 8 way/12 Way system Horizontal e , as complete all as specified Make- Siemen/Legrand/L & T/HPL/C&S/Schneider ) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |