| 1 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for laying of cable, fixing of pole etc and getting out in soft/loose soil, old serviceable bricks etc complete all as specified and as directed. |
| 2 | Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 4 | M&L for sand filling with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down complete all as specified and as directed. NOTE: Punned thickness shall be measured for measurement purpose. |
| 5 | Supply and laying burnt sub class 'B' bricks; available best quality laid in trenches for protections of under ground cable complete all as specified and as directed. |
| 6 | M&L for plain cement concrete (1:3:6) type C2 (using 40 mm gradeed stone aggregrate) as in foundation filling, coping for pole and mass concrete, filling of trenches across the road, etc. including all necessary formwork if required complete all as specified and as directed. |
| 7 | M&L for Cutting existing metal/bituminus road/PCC walk way/any type of tile works n.exc 0.45m width and n.exc 0.90 m in depth including all connected earth work and making good disturbed surfaces matching with the existing specification and finish including disposal of surplus material to a distance n.exc 50m complete all as specified and as directed. |
| 8 | S&F GI pipe, light grade, 50mm bore with all fittings and fixed to walls and ceilings or laid in floors and taking down old one complete all as specified and as directed |
| 9 | S&F GI pipe, light grade, 40mm bore with all fittings and fixed to walls and ceilings or laid in floors and taking down old one complete all as specified and as directed |
| 10 | S&F GI pipe, light grade, 80mm bore with all fittings and fixed to walls and ceilings or laid in floors and taking down old one complete all as specified and as directed |
| 11 | S&F High density polyethylene pipes (HDPE) 50mm dia, with pressure 6kgf/cm2 including socket, bends reducersetc fixed complete to walls, ceilings, layed in trenches or in floors etc. and taking down old one complete all as specified and as directed |
| 12 | Demoltion of PCC of any description and in any position including removal of debris outside MoD land complete all as specified and as directed |
| 13 | Demolition of P.C.C coping of any description poles, taking out unserviceable cable junction box, unserviceable cables including removal of debris outside MoD land complete all as specified and as directed. |
| 14 | M&L for providing plain cement concrete type B1 (1:2:4) using 20mm graded stone aggregrates as in copings, kneelers, columns posts and like, etc including watering, slghtly rounded or chamfered angles and throating including necessory form work complete all as specified and as directed. |
| 15 | M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed |
| 16 | M&L for 10 mm thick rendering on both faces of brick works or concreate surface in cement morter (1:4) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed |
| 17 | S&F in replacement On load change over switch, 800 Amps, 415 Volts, 4 poles complete all as specified and as directed. |
| 18 | S&F in replacement on load change over switch 630 Amps, 415 Volts, 4 poles complete all as specified and as directed. |
| 19 | S&F in replacement on load change over switch 400 Amps, 415 Volt, 4 poles complete all as specified and as directed. |
| 20 | S&F in replacement on load change over switch 320 Amps, 415 Volts, 4 poles complete all as specified and as directed. |
| 21 | S&F in replacement on load change over switch 160 Amps, 415 Volts, 4 poles complete all as specified and as directed. |
| 22 | S&F in replacement MCCB, 63 Amps, 16 kA, 4 Pole, with fixed magnetic & adjustable (80% - 100%) thermal release including all arranagement for mounting and testing, operating on 415V, 50Hz, AC supply complete all as specified and as directed |
| 23 | S&F in replacement MCCB, 125 Amps, 25 kA, 4 Pole with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz, AC supply complete all as specified and as directed |
| 24 | S&F in replacement MCCB, 160 Amps, 25 kA, 4 Poles, with fixed magnetic & adjustable (80% - 100%) thermal release including all arrnagement for mounting and testing, operating on 415V, 50Hz, AC supply complete all as specified and as directed |
| 25 | S&F in replacement MCCB, 200 Amps, 35 kA breaking capacity, 4 pole with fixed magnetic & adjustable (80% - 100%) thermal release complete all as specified and as directed |
| 26 | S&F in replacement MCCB, 250 Amps capacity, 4 pole, 35kA breaking capacity with fixed magnetic & adjustable thermal (80% - 100%) thermal release complete all as specified and as directed |
| 27 | S&F in replacement MCCB, 400 Amps capacity 4 pole 36KA breaking capacity with fixed magnetic & adjustable thermal (80% - 100%) thermal release complete all as specified and as directed |
| 28 | S&F in replacement MCCB, 630 Amps capacity, 4 pole, 50kA breaking capacity with fixed magnetic & adjustable thermal (80% - 100%) thermal release complete all as specified and as directed |
| 29 | S&F in repairs 1100 V grade FRLSH PVC insulated copper cables of size 1.5 sqmm 3 core drawn through street light poles brackes/PVC conduits connecting from the junction box to street light fittings complete all as specified and as directed |
| 30 | S&F in repairs 1100 V grade FR PVC insulated copper cables of size 2.5 sqmm 3 core drawn through PVC conduits/LDPE pipe/wall/duct etc complete all as specified and as directed |
| 31 | Disconnecting and taking out old unserviceable LT Under Ground Aluminium cable from Trench / Walls / Ducts and stacking aside for measuring for Schedule of Credit complete all as specified and as directed. |
| 32 | Supply and laying under ground heavy duty, XLPE insulated, armoured aluminium conductor cable 1100 volts grade, cross-sectional area 10 sqmm, 2 core laid in trenchches / through pipe or bare in road crossing / plinth/ drain/ duct/ floor along pole / wall /ceillings etc complete all as specified and directed. Note:- Earth work, bricks protection & sand cuisioning shall be measured and paid seperately. |
| 33 | All as per BOQ Serial item No.32 above but of size 16 sqmm 4 core complete all as specified and as directed |
| 34 | All as per BOQ Serial item No.32 above but of size 25 sqmm 4 core complete all as specified and as directed |
| 35 | All as per BOQ Serial item no 32 above but of size 35 sq. mm 3½ core complete all as specified and as directed |
| 36 | All as per BOQ Serial item no 32 above but of size 50 sq. mm 3½ core complete all as specified and as directed |
| 37 | All as per BOQ Serial item No.32 above but of size 70 sqmm 3.5 core complete all as specified and as directed |
| 38 | All as per BOQ Serial item No.32 above but of size 120 sqmm 3.5 core complete all as specified and as directed |
| 39 | All as per BOQ Serial item No.32 above but of size 240 sqmm 3.5 core complete all as specified and as directed |
| 40 | All as per BOQ Serial item No.32 above but of size 300 sqmm 3.5 core complete all as specified and as directed |
| 41 | S&F in repairs switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal for LT panel complete all as specified and directed. |
| 42 | S&F in repairs SPN 32A, 240 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 43 | S&F in repairs MCB 06 Amps to 32 Amps, single pole, 240 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 44 | S&F in repairs MCB TPN 40 To 100 AMP 415 Volt \\"C\\" series, breaking capacity 10 KA complete all as specified and as directed |
| 45 | S&F in repairs SPN MCB, DB, 8 way with 200 Amps rated bus bar, neutral link, suitable for mounting MCB's 240 volts, double door type complete all as specified and as directed |
| 46 | S&F in repairs Sheet metal enclosure MCB, DB, double door, Triple pole & neutral, 4 way with fully insulated 200 Amp bus bar for each phase, with 2 neutral bar, 2 earth bar and cable ties complete all as specified and as directedNOTE:- MCB's shall be measured and paid separately. |
| 47 | S&F in repairs AC power supply unit, 6 module consisting of in built modular motor starter, plug top, 20 Amp Socket and box duly fixed/grouted on wall complete all as specified and as directed. |
| 48 | S&F in repairs Round LED luminaire 15 watt, 220 V AC recessed type with high efficiency diffuser soft glare free light complete with inbuilt driver, suitable for roof ceiling cutout 140 mm including connecting up with driver three core flexible copper conductor wire of 0.75 Sqmm size complete all as specified and as directed. |
| 49 | S&F in repairs Fancy type LED mirror light fitting with PVC body having high out put diffuser 2 feet, 8-15 watt 220 V AC decorative type with inbuilt driver and LED lamp as per sample provided including connecting up with three core flexible copper conductor cable of 0.75sqmm size complete all as specified and as directed. |
| 50 | S&F Heat Shrink type straight through cable jointing kit for 1.1 KV grade Under Ground XLPE insulated Aluminium Cable complete with Jointing material and other connected accessories suitable for 3.5 / 4 core 10 to 16 sqmm complete all as specified and directed. |
| 51 | All as per BOQ Serial item no 50 above but for size 25sqmm to 50 sqmm, 3.5 core LT XLPE cables complete all as specified and directed. |
| 52 | All as per BOQ serial item no 50 above but of size 70 sqmm to 120 sqmm, 3.5 core complete all as specified and as directed. |
| 53 | All as per BOQ Serial item no 50 above but of size 150 sqmm to 300 sqmm 3.5 core complete all as specified and as directed. |
| 54 | S&F in repairs LED street light/building security light with IP 66 protection and front toughen glass luminaries of capacity 45/50 watt with high power LED and ensure uniform light distribution complete all as specified and as directed. |
| 55 | S&F in repairs LED security light with IP 66 protection and front toughen glass luminaries of capacity 70-75 watt with high power LED and ensure uniform light distribution complete all as specified and as directed. |
| 56 | S&F in repairs LED street light with IP 66 protection and front toughen glass luminaries of capacity 120-150 watt with high power LED and ensure uniform light distribution complete all as specified and as directed. |
| 57 | S&F in repairs LED flood light of IP protection 66 with front toughen glass luminaries of capacity 120-150 watt with high power LED and ensure uniform light distribution complete all as specified and as directed. |
| 58 | S&F in repairs LED flood light of IP protection 66 with front toughen glass luminaries of capacity 100 watt with high power LED and ensure uniform light distribution complete all as specified and as directed. |
| 59 | S&F in repairs LED flood light of IP protection 66 with front toughen glass luminaries of capacity 50 watt with high power LED and ensure uniform light distribution complete all as specified and as directed. |
| 60 | S&F in repairs 20 watt LED post top lantrerns fittings made in cast aluminium spigot, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessory electric connection with from junction box to post top lantern complete all as specified and as directed. |
| 61 | S&F in repairs 40 watt LED post top lantrerns fittings made in cast aluminium spigot, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessory electric connection with from junction box to post top lantern after complete all as specified and as directed. |
| 62 | S&F in repairs 10 watt LED bollard light 6000K, 2 feet long, 230V complete complete all as specified and as directed. |
| 63 | S&F in repairs Mushroom Post Top 40 watt LED light, 230V complete complete all as specified and as directed. |
| 64 | M&L for circuit/sub-main wiring with two run of 1100 V grade PVC insulated & unsheathed 2.5 Sqmm single core multi stranded copper conductor cable alongwith one run of 2.5 Sqmm 1100 V grade FRLSH PVC insulated & unsheathed single core multi stranded copper conductor cable for earth continuity conductor connected to common earth dolly, drawn through PVC conduit/casing caping complete all as specified and as directed. Note : Three runs of 2.5 Sqmm cable and one length of PVC conduit shall measured as one length. |
| 65 | M&L for circuit/sub-main wiring with two run of 1100 V grade PVC insulated & unsheathed 1.5 Sqmm single core multi stranded copper conductor cable alongwith one run of 1.5 Sqmm 1100 V grade FRLSH PVC insulated & unsheathed single core multi stranded copper conductor cable for earth continuity conductor connected to common earth dolly, drawn through PVC conduit/casing caping complete all as specified and as directed. Note :Three runs of 1.5 Sqmm cable and one length of PVC conduit shall measured as one length. |
| 66 | M&L for circuit/sub-main wiring with two run of 1100 V grade PVC insulated & unsheathed 4.0 Sqmm single core multi stranded copper conductor cable alongwith one run of 4.0 Sqmm 1100 V grade FRLSH PVC insulated & unsheathed single core multi stranded copper conductor cable for earth continuity conductor connected to common earth dolly, drawn through PVC conduit/casing capping complete all as specified and as directed. Note : Three runs of 4.0 Sqmm cable and one length of PVC conduit shall measured as one length. |
| 67 | S&F Mild steel works consisting of wire mesh, MS angle, square pipe, flat, etc duly cut into shape and size to fabricate cage for Post top lanterns mounted on boundary wall including grouting on wall, one coat of red oxide meteal primar and two coats of synthetic enamel paint complete all as specified and as directed |
| 68 | S&F in repairs thermoplastic street light junction box, weather proof having ingress protection level IP-66 and size L (254-255mm)x B (180-205mm)x H(111-112mm) duly fixed with Aluminium flat clamp and support made of 25mmx3mm/Flush in existing wall, duly painted with aluminium paint over a coat of red oxide metal prmer complete (including 1 no 5 way cable connector suitable to connect 16 Sqmm Aluminium cable 3 nos polymide cable gland having sealing range 17-25 mm complete with 1 No 19 mm PVC blend) complete all as specified and as directed |
| 69 | M&L for painting external surfaces of steel tubular poles and brackets of height upto 9m above ground level after preparation of old painted and rusted surfaces with two coats of aluminium paint over a coat of red oxide primer and writing pole No. with black colour on round yellow background or pasting of sticker 100 mm dia (yellow clour) with black lettering 50mm complete all as specified and as directed. |
| 70 | S&F in replacement Steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) complete complete all as specified and directed. |
| 71 | S&F end termination (cable gland & lugs ) for cable of size 10 to 25 Sqmm, 4 Core complete all as specified and as directed |
| 72 | S&F end termination (cable gland & lugs ) for cable of size 35 to 70 Sqmm, 3.5 Core complete all as specified and as directed |
| 73 | S&F end termination (cable gland & lugs ) for cable of size 95 to 150 Sqmm, 3.5 Core complete all as specified and as directed |
| 74 | S&F end termination (cable gland & lugs ) for cable of size 185 to 400 Sqmm, 3.5 Core complete all as specified and as directed |
| 75 | M&L for making of 20mm hole in steel tublar pole, by using drill/electric arc welding etc at a level 0.9 mtr above ground level and 100mm below the bottom connecting cable complete all as specified and as directed |
| 76 | S&F in repairs GI bracket on street light pole/ boundary wall for post top lantern made of 40 mm dia light grade GI pipe including fixing clamps, nuts and bolts/cement work and painting with two coats of aluminium paint over a coat of red oxide metal primer complete for maximum length of 1.20mtr complete all as specified and as directed |
| 77 | S&F low density poly ethylene (LDPE) pipe, flexible type of pressure rating 6.0 kg/sqm laid through the coping of the poles for passing of pipes complete all as specified for bore of pipe 40mm complete all as specified and directed. |
| 78 | S&F low density poly ethylene (LDPE) pipe, flexible type of pressure rating 6.0 kg/sqm laid through the coping of the poles for passing of pipes complete all as specified for bore of pipe 32mm complete all as specified and directed. |
| 79 | S&F perforated GI Cable Tray, made of Plain GI sheet of thickness 1.20 mm, of size 600 mm wide x 75 mm depth with cover duly fixed on wall / Roof by M.S. Bracket or hanging from ceiling with down rod etc, complete all as specified and as directed |
| 80 | All as per BOQ Serial item no 79 above but of size 450mm complete all as specified and as directed |
| 81 | All as per BOQ Serial item no 79 above but of size 300 mm complete all as specified and as directed |
| 82 | All as per BOQ Serial item no 79 above but of size 200 mm complete all as specified and as directed |
| 83 | All as per BOQ Serial item no 79 above but of size 100 mm complete all as specified and as directed |
| 84 | S&F in repairs outdoor type floor mounted, 4 way Bus Bar Chamber made 3.0 mm thick M.S. sheet duly painted with powder coated paint (RAL7032 Siemens Grey) having 4 Nos of insulated Aluminium Bus Bar of 200 A rating and size 800mm(w) x 800mm(H) x 400mm(D) with hinged Single Door in both front and rear side (with locking arrangement), 4 side sloped roof and 600mm long M.S Angle (50x50x6mm) leg, Earthing Termination Bolt etc. complete all as specified and as directed. |
| 85 | S&F in repairs outdoor type floor mounted 4 way Bus Bar Chamber made 3.0 mm thick MS sheet duly powder coated (RAL7032 Siemens Grey) having 4 Nos of insulated Aluminium Bus Bar of 63 A rating and size 800mm(w)x800mm(H)x400mm(D) with hinged Single Door in both front and rear side (with locking arrangement), 4 side sloped roof and 600mm long M.S Angle (50x50x6mm) leg, Earthing Termination Bolt etc. complete all as specified and as directed. |
| 86 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
| 87 | S&F DMC/SMC/Ebonite cable connector 4 Way complete all as specified and directed. |
| 88 | S&F in repairs LED strip 120 Led 10.5w - 5mm-12v-IP65 Waterproof warm white complete all as specified and directed. |
| 89 | S&F in repairs PVC insulated 25 Sqmm S/C copper cable complete all as specified and directed. |
| 90 | S&F in repairs PVC insulated 16 Sqmm S/C copper cable complete all as specified and directed. |
| 91 | S&F in repairs PVC insulated 50 Sqmm S/C copper cable complete all as specified and directed. |
| 92 | S&F in repairs copper lugs 16/25mm ring type complete all as specified and directed. |
| 93 | S&F in repairs copper lugs 50mm ring type complete all as specified and directed. |
| 94 | Dismantling and taking down carefully sub-main wiring any size including wooden batten etc and making good the disturbed surfaces of wall/ floor to match the existing wall/ floor etc complete all as specified & directed. |
| 95 | M&L for reparing and painting of feeder pillar / LT panelboard complete all as specified and as directed as under :- |
| 96 | S&F in repairs MS sheet for feeder pillar for Roof or for Panel Board Door by cutting into required size and shape, moulding, Welding, drilling etc including painting with two coats of existing shades of Synthetic Enamel Paint over & including a coat of Red Oxide Metal Primer complete all as specified and as directedNote : Thickness of the new sheet shall be same as per existing one. |
| 97 | S&F in repairs Capsule type M.S. door hinges for Feeder Pillar / Panel Board duly fixed by welding complete all as specified and as directed |
| 98 | S&F in repairs Castle type door locks for Feeder Pillars / Panel Boards as per existing one complete all as specified and as directed |
| 99 | S&F in repairs aluminium Lugs/ thimbles of sizes as required on ground complete by crimping and wrapped with insulation tape complete all as specified and as directed. |
| 100 | S&F in repairs DMC / SMC / Ebonite Cable Connector 3 or 4 way suitable for 1100 volt grade all as per existing type / Current Rating etc. complete all as specified and as directed. |
| 101 | S&F in repairs Aluminium bus bar of any size with necessary drilling and providing suitable size & colour heat shrinkable type PVC tape complete all as specified and as directed |
| 102 | Preparation of old painted surface in situ of feeder pillars (for external surfaces only) with one coat of red oxide primer and M&L for applying two coats of 1st quality Synthetic Enamel Paint after cleaning of existing surface and removing of all loose darts and greasy spots and filling of cavities by providing putty complete all as specified and as directed.Note : Painting to be done either by using Spray Painting Machine or by using Roller. |
| 103 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 metre below normal ground level with top edge of the plate not less then 1.50 metre below normal ground level connected to galvanized earth 32mm x 6 mm GI strip by means of bolts, nuts, check nuts and washers complete up to and including test point made out of 40 x 6mm aluminium flat including excavation in any type of soil for earthing pit, charcoal, common salt 25mm dia medium grade GI watering pipe, PCC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2009 (Part-I) complete all as specified and as directed.NOTE: Main earthing lead & protection pipe 40 mm dia light grade from earth electrode to test point upto 7.5 mm is deemed to be included in quoted unit rate. Please Enable Macros to View BoQ information |