| Sl. No. | Item Description |
| 1 | Carriage of materials: Carriage of materials by mechanical transport including loading, unloading and stacking: Lime, moorum, building rubbish:1 km |
| 2 | Carriage of materials: Carriage of materials by mechanical transport including loading,unloading and stacking: Earth:1 km |
| 3 | Earth work: Earth work in surface excavation not exceeding 30 cm in depth but exceeding1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be levelled and neatly dressed ::All kinds of soil |
| 4 | Earth work: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.: All kinds of soil |
| 5 | Earth work: Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :: All kinds of soil:Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 6 | Earth work:Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | Earth work: Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.:All kinds of soil |
| 8 | Earth work:Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Unit:cum |
| 9 | concrete work: Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) Unit:cum CEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 10 | concrete work: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Unit:cum CEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 11 | Reinforced Cement Concrete: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :mm nominal size):1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Unit:cumCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 12 | Reinforced Cement Concrete: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement ::1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Unit:cumCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 13 | Reinforced Cement Concrete:Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) CEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORES |
| 14 | Reinforced Cement Concrete: Centering and shuttering including strutting, propping etc.and removal of form for ::Foundations, footings, bases of columns, etc. for mass concrete Unit:sqm |
| 15 | Reinforced Cement Concrete: Centering and shuttering including strutting, propping etc. and removal of form for ::Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Unit:sqm |
| 16 | Reinforced Cement Concrete: Centering and shuttering including strutting, propping etc.and removal of form for ::Suspended floors, roofs, landings, balconies and access platform Unit:sqm |
| 17 | Reinforced Cement Concrete: Centering and shuttering including strutting, propping etc. and removal of form for ::Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Reinforced Cement Concrete: Centering and shuttering including strutting, propping etc.and removal of form for ::Columns, Pillars, Piers, Abutments, Posts and Struts |
| 19 | Reinforced Cement Concrete: Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) .:Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) Unit:sqm |
| 20 | Reinforced Cement Concrete:Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Unit:cum CEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORES |
| 21 | Reinforced Cement Concrete:Encasing rolled steel sections, in beams and columns, with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)), including centering and shuttering complete but excluding cost of reinforcement. Unit:cumCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 22 | Reinforced Cement Concrete: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.:Thermo- Mechanically Treated bars of grade Fe-500D or more. Unit:KgTMT BARS SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 23 | Reinforced Cement Concrete: Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).:All works upto plinth level Unit:cum |
| 24 | Reinforced Cement Concrete: Providing and laying in position machine batched andmachine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retardsetting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).:Allworks above plinth level upto floor V level Unit:cum |
| 25 | Masonary work: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in::Cement mortar 1:6 (1 cement : 6 coarse sand) Unit:cumCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 26 | Masonary work: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in ::Cement mortar 1:6 (1 cement : 6 coarse sand) Unit:cumCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 27 | Cladding work:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. NOTE: Item no8.31 is brought from Sub Head 11 i.e. Flooring, Item No 11.36 Unit:sqmCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 28 | Wood and PVC work: Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete::100x63x3.2 mm Unit:each |
| 29 | Wood and PVC work: Providing and fixing ISI marked aluminium butt hinges anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete::75x63x3.2 mm Unit:each |
| 30 | Wood and PVC work: Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyedto required colour or shade, with nuts and screws etc. complete ::300x16 mm Unit:each |
| 31 | Wood and PVC work: Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ::250x10 mm Unit:each |
| 32 | Wood and PVC work: Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ::150x10 mm Unit:each |
| 33 | Wood and PVC work: Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete ::125 mm Unit:each |
| 34 | Wood and PVC work: Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete ::75 mm Unit:each |
| 35 | Wood and PVC work: Providing and fixing aluminium hanging floor door stopper, ISImarked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.:Single rubber stopper Unit:each |
| 36 | Steel work:Structural steel work in single section, fixed with or without connectingplate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Unit:kgSTRUCTURAL STEEL SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 37 | Steel work:Providing and fixing mild steel round holding down bolts with nuts and washerplates complete. Unit:kg |
| 38 | Steel work:Providing and fixing bolts including nuts and washers complete. Unit:kg |
| 39 | Flooring: Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, butexcluding the cost of nosing of steps etc. complete. :40 mm thick with 20 mm nominal size stone aggregate Unit:sqmCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 40 | Flooring: Providing and fixing glass strips in joints of terrazo / cement concrete floors.:40mm wide and 4 mm thick. Unit:metre |
| 41 | Flooring:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.Unit:sqm CEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 42 | Flooring: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.:Size of Tile 600x600mm Unit:sqmCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 43 | Roofing: Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.:75 mm diameter |
| 44 | Roofing: Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.:110 mm diameterUnit:metre |
| 45 | Roofing: Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.:Single tee without door:75x75x75 mm Unit:each |
| 46 | Roofing: Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.:Single tee without door:110x110x110 mm Unit:each |
| 47 | Roofing: Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.:Bend 87.5°:75 mm bend Unit:each |
| 48 | Roofing: Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.:Bend 87.5°:110 mm bend Unit:each |
| 49 | Roofing: Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. Theyshall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented,textured or smooth as specified.:2mm thick corrugated (2.5\\" or 4.2\\" or 6\\") or step-down (2\\" or 3\\" or 6\\" ) as specified Unit:sqm |
| 50 | Roofing: Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. Theyshall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented,textured or smooth as specified.: 2mm thick flat Unit:sqm |
| 51 | Roofing:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Unit:sqm |
| 52 | Roofing: Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete ::Ridges plain (500- 600mm) Unit:metre |
| 53 | Finishing: 12 mm cement plaster of mix : :1:6 (1 cement: 6 fine sand) Unit:SqmCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 54 | Finishing: 15 mm cement plaster on the rough side of single or half brick wall of mix : :1:6 (1 cement: 6 fine sand) Unit:SqmCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 55 | Finishing: 6 mm cement plaster of mix : :1:3 (1 cement: 3 fine sand) Unit:SqmCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 56 | Finishing: Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer. Unit:Sqm |
| 57 | Finishing: Finishing walls with Acrylic Smooth exterior paint of required shade : :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). Unit:Sqm |
| 58 | Finishing: Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : :Two or more coats on new work. Unit:Sqm |
| 59 | Finishing:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Unit:Sqm |
| 60 | Dismantling and Demolishing: Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. :Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Unit:Cum |
| 61 | Dismantling and Demolishing:Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50metres lead as per direction of Engineer - in- charge. Unit:Cum |
| 62 | Dismantling and Demolishing:Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer - in -charge. Unit:Sqm |
| 63 | Dismantling and Demolishing: Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. :In cement mortar Unit:Cum |
| 64 | Road work: Supplying and stacking at site.:63 mm to 45 mm size stone aggregate Unit:cum |
| 65 | Road work:Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . Unit:cum |
| 66 | Road work: Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per work and concrete work to be paid for separately). Payment to be 100 m (minimum), between the two posts fitted and fixed with G.I. made per metre cost of total length of barbed wire used.: With G.I. barbed wire Unit:metre |
| 67 | Sanitary Installationa: Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : :White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. Unit:EachCEMENI SHALL BE ISSUED FREE OF CAST AT BHEL STORES. |
| 68 | Sanitary Installationa:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. Unit:eachCEMENI SHALL BE ISSUED FREE OF CAST AT BHEL STORES. |
| 69 | Sanitary Installationa: Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings ::Flat back wash basin of size 550x400 mm Unit:eachCEMENI SHALL BE ISSUED FREE OF CAST AT BHEL STORES. |
| 70 | Sanitary Installationa: Providing and fixing P.V.C. waste pipe for sink or wash basinincluding P.V.C. waste fittings complete.: Flexible pipe: 32 mm dia Unit:each |
| 71 | Sanitary Installationa:Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Unit:each |
| 72 | Water Supply: Providing and fixing G.I. Pipes complete with G.I. fittings and clamps i/cmaking good the walls etc. concealed pipe including painting with anticorrosive bitumastic paint, cutting chases and making good the wall :15 mm dia nominal bore Unit:metreCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORES |
| 73 | Water Supply: Providing and fixing G.I. Pipes complete with G.I. fittings and clamps i/cmaking good the walls etc. concealed pipe including painting with anticorrosive bitumastic paint, cutting chases and making good the wall :20 mm dia nominal bore Unit:metreCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORES |
| 74 | Water Supply: Providing and fixing G.I. pipes complete with G.I. fittings including trenchingand refilling etc. External work :65 mm dia. nominal bore Unit:metre |
| 75 | Water Supply: Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete : :15 mm nominal bore Unit:Each |
| 76 | Water Supply: Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : :20 mm nominal bore Unit:Each |
| 77 | Water Supply: Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : : 100 mmdiameter :Class I Unit:Each |
| 78 | Water Supply: Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : : 150 mmdiameter :Class I Unit:Each |
| 79 | Water Supply: Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : : 300 mmdiameter :Class I Unit:Each |
| 80 | Water Supply: Providing and fixing G.I. Union in G.I. pipe including cutting and threadingthe pipe and making long screws etc. complete (New work) :15 mm nominal bore Unit:Each |
| 81 | Water Supply: Providing and fixing G.I. Union in G.I. pipe including cutting and threadingthe pipe and making long screws etc. complete (New work) :20 mm nominal bore Unit:Each |
| 82 | Water Supply: Providing and fixing PTMT bib cock of approved quality and colour. :15mmnominal bore, 86 mm long. Weighing not less than 88 gms. Unit:Each |
| 83 | Water Supply:Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighingnot less than 85 gms. Unit:Each |
| 84 | Water Supply: Providing and laying D.I. specials of class K-12 suitable for push-on jointingas per IS : 9523 :Up to 600 mm dia Unit:Qtl |
| 85 | Water Supply: Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipesconforming to IS : 8329 : :100 mm dia Ductile Iron Class K-7 pipes Unit:metre |
| 86 | Water Supply: Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipesconforming to IS : 8329 : :150 mm dia Ductile Iron Class K-7 pipes Unit:metre |
| 87 | Water Supply: Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipesconforming to IS : 8329 : :300 mm dia Ductile Iron Class K-7 pipes Unit:metre |
| 88 | Water Supply: Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. :15 mm nominal bore with 45 cm length.Unit:Each |
| 89 | Drainage: Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete ::1000 mm dia. R.C.C. pipe Unit:metreCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORES |
| 90 | Drainage: Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete ::150 mm dia. R.C.C. pipe Unit:metreCEMENT SHALL BE ISSUEDFREE OF COST AT BHEL STORE |
| 91 | Drainage: Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete ::300 mm dia. R.C.C. pipe Unit:metreCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 92 | Drainage: Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete ::500 mm dia. R.C.C. pipe Unit:metreCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORES |
| 93 | Drainage: Providing and fixing in position pre-cast R.C.C. manhole cover and frame ofrequired shape and approved quality : M D - 10 :Circular shape 500mm internal diameter Unit:each |
| 94 | Aluminium work: Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminiumsections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions ofEngineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : : Forfixed portion :Powder coated aluminium (minimum thickness of powder coating 50 micron) Unit:Kg |
| 95 | Aluminium work: Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminiumsections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). :Powder coatedaluminium (minimum thickness of powder coating 50 micron) Unit:Kg |
| 96 | Aluminium work: Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. :Pre-laminated particle board with decorative lamination on one sideand balancing lamination on other side. Unit:Sqm |
| 97 | Aluminium work: Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): :With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) Unit:Sqm |
| 98 | Aluminium work: Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in- charge. :With stainless steel cover plate minimum 1.25 mm thickness. Unit:each |
| 99 | Aluminium work:Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors includingnecessary cutting and making good etc. complete. Unit:each |
| 100 | Aluminium work: Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge :Powder coated minimum thickness 50 micron aluminium Unit:each |
| 101 | Aluminium work:Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured forpayment). Unit:Kg |
| 102 | Water proofing: Grading roof for water proofing treatment with :Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Unit:CumCEMENT SHALL BE ISSUED FREE OF COST AT BHEL STORE |
| 103 | .PREPARATION OF SURFACE BY CLEANING AND SCRAPPING, REPAIRING THE ROOF WITH CEMENT MIXED WITH WATER-PROOFING MATERIAL, LAYING FIBRE MESH WITH POLYMER BASED PRIMER AND APPLYING MINIMUM TWO COATS OF ACYCLIC WATER PROOFING COMPOUND OF APPROVED BRAND, ALL COMPLETE AS PER REQUIREMENT ANDDIRECTION OF ENGINEER-IN-CHARGE. (ALL THE MATERIALS, LABOUR AND T&P REQUIRED TO COMPLETE THE WORK ARE TO BE ARRANGED BY THE CONTACTOR.) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail