| 1 | M&L for Comprehensive maintenance of Central Gas supply System and its allied equipments including minor repairs of manifold panel for Oxygen- 300 Points, Nitrous Oxide-14 and vaccum system- 300 Points, Air-51 points, CO2 -07 points, pipe line, 04 nos - Air Compressor pump/motor, 04 nos. vaccum pump and cylinder and empty indication system for a total period of 06 calender months complete all as specified and directed.Note : (i) Unit rates is deemed to be inclusive of taking down unserviceable defective parts/accessories and replacement with new one; including fixing of spare parts as and when required including welding/soldering etc for smooth and efficient functioning of the system; changing of lubricating oil (Castor-30) of 4 nos vaccum pump once in a year. (ii) New spare parts shall be measured and paid separately as supply only. (iii) Any spares required except here-in-below is deemed to be included in the quoted unit rate and nothing extra shall be paid. |
| 2 | Supply only OR - 14 regulator for oxygen & Nitrous control panel as per sample complete all as specified and directed. |
| 3 | Supply only gauge for oxygen & Nitrious 0 to 14 Kg as per sample complete all as specified and directed. |
| 4 | Supply only Non Return valve suitable for oxygen, nitrious & CO2 manifold as per sample complete all as specified and directed. |
| 5 | Supply only self seal double lock valve for following as per sample complete all as specified and directed :- |
| 6 | Oxygen |
| 7 | Nitrous |
| 8 | Vacuum |
| 9 | Supply only safety keyed plug for following as per sample complete all as specified and directed :- |
| 10 | Oxygen |
| 11 | Nitrous |
| 12 | Vacuum |
| 13 | Supply, installation, jointing, testing and commissioning in repairs the following Medical grade Copper Pipe line with suitable fiittings; Copper pipe shalll be solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased material conforming to BS:EN:13348:2001+A1:2005; Fittings shall be made of copper and suitable for a steam of working pressure of 17 bar and conforming to BS:864 specially made for brazed socket type connection complete all as specified and directed.(Certified 18-04-57). Make- Metal Alloys/Max flow or equivalnet as approved by GE |
| 14 | 42mm OD X 1.2mm wall thickness |
| 15 | 28mm OD X 0.9mm wall thickness |
| 16 | 22mm OD X 0.9mm wall thickness |
| 17 | 15mm OD X 0.9mm wall thickness |
| 18 | 12mm OD X 0.7mm wall thickness |
| 19 | Supply, installation, testing and commissioning in repairs Gas outlet points/terminal units with matching probes for Oxygen, Nitrous Oxide, Medical Air 4 Bar/7 Bar, CO2, front loading type, BS type complete all as specified and as directed of for the following :- |
| 20 | Oxygen Port. |
| 21 | Vacuum Port. |
| 22 | S&F in repairs LINE ISOLATION VALVES complete all as specified and directed for following sizes of valves :-Make- Matrix/Hospitech service and sales/Zoloto/RN/JSI or equivalent as approved by GE |
| 23 | 12 mm valve |
| 24 | 15 mm valve |
| 25 | 22 mm valve |
| 26 | 28 mm valve |
| 27 | 42 mm valve |
| 28 | 54 mm valve |
| 29 | S&F in repairs copper tail pipe for oxygen/nitrous gas including 5/8 Hex-nut, nipple, head connection with KE nipple complete all as specified and directed. |
| 30 | S&F in repairs humidyfire bottle including BPC flow meter for oxygen as per sample complete all as specified and directed. |
| 31 | S&F in repairs ward vaccum unit including regulator, gauge for showing negative pressure and 600ml receiver jar complete all as specified and directed. |
| 32 | S&F in repairs receiver Jar for ward vaccum unit 0 - 600 ml complete as per sample complete all as specified and directed. |
| 33 | M&L for applying one coat of synthetic enamel paint to med gas pipe line for oxygen, Nitrious & vaccum with proper colour coading (Colour for oxygen- white, for Nitrious- Blue & for Vaccum- Yellow) after cleaning/scrapping of old paint complete all as specified and directed. |
| 34 | M&L for cutting the existing gas/vaccum pipe line for supply, insertion of suitable size of tee for pipe of dia 22/15 mm for new point / leakage repair as required including with all necessary arrangement like soldering/welding etc complete all as specified and directed. |
| 35 | M&L for cutting the existing gas/vaccum pipe line for supply, insertion of suitable size of tee for pipe of dia 42/28 mm for new point / leakage repair as required including with all necessary arrangement like soldering/welding etc complete all as specified and directed. |
| 36 | S&F in repairs port let outlet valve of following as per sample complete all as specified and directed. |
| 37 | Oxygen |
| 38 | Nitrous |
| 39 | Vacuum |
| 40 | S&F in repairs adaptor port let for oxygen /Nitrous/vaccum as per sample complete all as specified and directed. |
| 41 | S&F in repairs Operation theater vacuum unit as per sample complete all as specified and directed. |
| 42 | S&F in repairs line pressure gauge for control panel of O2/N20 as per sample complete all as specified and directed. |
| 43 | S&F in repairs bonnet for OR-14 regulator for oxygen/nitrous as per sample complete all as specified and directed. |
| 44 | S&F in repairs spring for OR-14 regulator for oxygen/nitrous as per sample complete all as specified and directed. |
| 45 | S&F in repairs diaphgram OR-14 as per sample complete all as specified and directed. |
| 46 | S&F in repairs diaphgram carrier as per sample complete all as specified and directed. |
| 47 | S&F in repairs diaphgram plate as per sample complete all as specified and directed. |
| 48 | S&F in repairs O-ring (big/small) as per sample complete all as specified and directed. |
| 49 | S&F in repairs nipple inlet flat as per sample complete all as specified and directed. |
| 50 | S&F in repairs brass ring for OR-14 as per sample complete all as specified and directed. |
| 51 | S&F in repairs seat nylon as per sample complete all as specified and directed. |
| 52 | S&F in repairs safety valve as per sample complete all as specified and directed. |
| 53 | S&F in repairs outlet Iox -69 as per sample complete all as specified and directed. |
| 54 | S&F in repairs copper tube connection for non return as per sample complete all as specified and directed. |
| 55 | S&F in repairs gasket for BPC jar as per sample complete all as specified and directed. |
| 56 | S&F in repairs gasket for vacuum jar as per sample complete all as specified and directed. |
| 57 | S&F in repairs HP tubing for oxy/nit/vac as per sample complete all as specified and directed. |
| 58 | S&F in repairs LP tubing for BPC flow meter as per sample complete all as specified and directed. |
| 59 | S&F in repairs saddle for copper tubing 12 mm dia as per sample complete all as specified and directed. |
| 60 | S&F in repairs saddle for copper tubing 15 mm dia as per sample complete all as specified and directed. |
| 61 | S&F in repairs saddle for copper tubing 22 mm dia as per sample complete all as specified and directed. |
| 62 | S&F in repairs saddle for copper tubing 28 mm dia as per sample complete all as specified and directed. |
| 63 | S&F in repairs PB Oxygen (Wall Mounted) Outlet with 3/8 BSB thread probe complete all as specified and directed. |
| 64 | S&F in repairs PB vacuum (Wall Mounted) Outlet with Hose type probe complete all as specified and directed. |
| 65 | S&F in repairs PB AIR (Wall Mounted) Outlet with Hose type probe complete all as specified and directed. |
| 66 | S&F in repairs PB N2O (Wall Mounted) Outlet with Hose type probe complete all as specified and directed. |
| 67 | S&F in repairs PB CO2 (Wall Mounted) Outlet with Hose type probe complete all as specified and directed. |
| 68 | S&F in repairs Oxygen BPC flow meter with Humidifier bottle for bed head panels complete all as specified and directed. |
| 69 | S&F in repairs Ward vacuum unit with 600 ML receiving jar for bed head panels complete all as specified and directed. |
| 70 | Dismantling and opening the motor from Air Compressor system in existing position and M&L for rewinding with new super enamelled copper wire of suitable gauge (as per existing) and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same in original position; Capacity of motor - 15 HP 3 PH complete all as specified and directed. |
| 71 | Dismantling and opening the motor from Air Compressor system in existing position and M&L for rewinding work with new super enamelled copper wire of suitable gauge (as per existing) and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same in original position; Capacity of motor -10 HP 3 PH complete all as specified and directed. |
| 72 | S&F in repairs Needle bearing with seal LP for Air Compressor (02Sets) as per sample complete all as specified and directed. |
| 73 | S&F in repairs Needle bearing with seal HP for Air Compressor (01Sets) as per sample complete all as specified and directed. |
| 74 | S&F in repairs Valve LP with packing set for Air Compressor as per sample (02 Sets) complete all as specified and directed. |
| 75 | S&F in repairs Valve HP with packing set for Air Compressor as per sample (01Set) complete all as specified and directed. |
| 76 | S&F in repairs filter element for Air Compressor as per sample (02 nos) complete all as specified and directed. |
| 77 | S&F in repairs 2 gas alarm (Digital type) for 2 Gases complete all as specified and directed. |
| 78 | S&F in repairs 3 gas alarm (Digital type) for 2 Gases complete all as specified and directed. |
| 79 | S&F in repairs 4 gas alarm (Digital type) for 2 Gases complete all as specified and directed. |
| 80 | S&F in repairs pendent outlet valve for for oxygen complete all as specified and directed. |
| 81 | S&F in repairs pendent outlet valve for for Nitrous oxide complete all as specified and directed. |
| 82 | S&F in repairs pendent outlet valve for vaccumm complete all as specified and directed. |
| 83 | S&F in repairs pendent outlet valve for CO2 complete all as specified and directed. |
| 84 | S&F in repairs pendent outlet valve for Air complete all as specified and directed. |
| 85 | S&F in repairs Brass non Return valve for oxgen & Nitrious for control pannel as per sample complete all as specified and directed. |
| 86 | S&F in repairs Air pressure controlling Regulator valve with inlet outlet dia 20 mm for (0 to 10 Bar) Air delivery line complete all as specified and directed.Make - JANATICS /Hospitech service and sales or equivalent as approved by GE |
| 87 | S&F in repairs Brass Non Return valve, dia 50 mm, suitable for copper pipe line of vacuum, air, oxgen & Nitrious gas as per sample. complete all as specified and directed. |
| 88 | S&F in repairs tune up kit for vaccum pump. complete all as specified and directed. |
| 89 | Supply, fixing & testing of Horizotal hospital Bed head panel not less than size of 1200 mm X 300 mm X 125 mm length dual rail side extrusion, thickness 4.5 mm, Middle plate 5 mm, side cover 2 mm, Epoxy powder coated, Gas outlet BS/BP type outlet, Oxygen outlet - 02 nos, Vaccum Outlets - 01 No, 05/15 multi sockets modular type with switch- 05 Nos, IV stand - 01 no, Slider-01 nos; TECHNOMED type of probe DOUBLE LOCKING probe/ adaptor - ELECTYRD PLATED BRASS MATERIAL IV POLE SS - GRADE 304 DIMENSSION - 350 X 8 mm utility basket as per HTM 2022 standard it should have testing after installation complete all as per specified and as directed. (Make: TECHNOMED or equivalent make as approved by GE). |
| 90 | S&F Air Compressor components for Main Manifold / Mother and child care manifold plant complete all as specified and directed as listed below :- |
| 91 | Cylinder HP |
| 92 | Piston set HP |
| 93 | CV KIT |
| 94 | Piston Ring Set LP |
| 95 | Piston Ring Set HP |
| 96 | Grease KIT |
| 97 | Intake filter element |
| 98 | Crankcase filter element with felt |
| 99 | Piston Pin HP |
| 100 | Niddle bearing with seal |
| 101 | Piston set HP |
| 102 | Piston set LP |
| 103 | Supply, fixing & testing of Horizotal hospital Bed head panel not less than size of 1500 mm X 300 mm X 125 mm length dual rail side extrusion, thickness 4.5 mm Middle plate 5 mm side cover 2 mm , Epoxy powder coated Gas outlet BS/BP type outlet; Oxygen outlet - 02 nos, Vaccum Outlets - 01 No, 05/15 multi sockets modular type with switch- 05 Nos, IV stand - 01 no, Slider-01 nos; TECHNOMED type of probe DOUBLE LOCKING probe/ adaptor - ELECTYRD PLATED BRASS MATERIAL IV POLE SS - GRADE 304 DIMENSSION - 350 X 8 mm utility basket as per HTM 2022 standard it should have testing after installation complete all as per specified and as directed. (Make: TECHNOMED or equivalent make as specified by GE). |
| 104 | S&F in repairs Desiccant/Heatless Air Dryer YLHD-70 for Manifold plant with following specifications: Flow - 70 CFM, Pressure - 7-12 bar (kg/cm3), Max Inlet temp- 45 deg C, Max Outlet temp- 30-35 deg C, Working Temp : 5-45 degC, Atm dew point : (-) 45 degC, Voltage Range : 230 V/1h/50 Hz complete all as per specified and as directed. Make-Yunik Air /OR equivalent as approved by GE. |
| 105 | S&F in repairs Vacuum bacteria free filter for manifold plant complete all as specified and as directed with following specification: (i) Vacuum Bacteria free filter (Make-Trident or equivalent make as specified by GE), Borosilicate filter element 99.99% efficiency, Complaint with Health Technical memorandum 2022, Lightweight, corrosion-protectec aluminium body, Differential pressure gauge indicator for filter element replacement, sterilisable drain flask to capture biological fluids, Vacuum flow rates from 850-7504 litres/min (30-265 scfm), Available in 1\\" to 3\\" pipe connections.(ii) Penetration to BS 3928<0.005%, Particle removal : 0.3 micron (99.995%), Maximum Temperature : 80 deg C (176 deg farenhite), Pressure loss clean element 30 mbar, Pressure loss change element : 100 mbar, Maximum working vacuum : Full vacuum, Filter element : Borosilicate, Construction material : Extruded aluminium alloy, Coating-External : Epoxy powder coating, Coating - Internal : Anodised, Drain Type : Hand shut off valve with sterilisable drain flask (capacity 100 ml). Please Enable Macros to View BoQ information |