| 1 | Sub Head -IGym Equipments and accessories in the existing Gym at Hostel Block of UTCS Bldg. |
| 2 | Supplying & fixing of 4 multi-Station commercial-grade gym equipmentFrame Material: Durable iron with a coated surface finishDimensions (L*W*H): 3450 x 2150 x 2330 mmNet Weight (N.W): 710 kgGross Weight (G.W): 770 kgWeight Stack: 360 kg (WS)Power Source: Manual (no external power required)Operation Mode: Adjustable Seat/Backrest: Ergonomically designed, black color, with adjustable options Functions: Designed for multifunctionality, including straight arm chest training, sitting high and low pull training, unilateral bird training, and leg extension and flexion |
| 3 | Supplying & fixing of Olympic 3 in 1 Bench Workout: Flat, Incline, Decline Chest Press and Seated Abs Ergonomically designed structure.Seat made from a high density 50mm foam; upholstered in water-resistant Rexene for increased product life.Polyurethane paint used for smooth finish of the MS tubes Powder coating (customizable). |
| 4 | Supplying of Imported Olympic weightlifting and powerlifting MS rod. Standard Length: 7 feet |
| 5 | Supplying of Imported MS Straight rod. Length: 5 feet |
| 6 | Supplying of Imported MS Straight rod. Length: 4 feet |
| 7 | Supplying of Imported Curl MS rod.Length: 4 feet |
| 8 | Supplying & Fixing of Commercial grade Flat bench Type of Bench: Utility stool/bench (non-adjustable)Usage/Application: Commercial GymFrame Material: Cast iron or alloy steel constructionFrame Finish: Color coated (anti-rust powder coating) |
| 9 | Supplying & Fixing of Commercial grade Utility benchType of Bench: Utility stool/bench (non-adjustable)Usage/Application: Commercial GymFrame Material: Cast iron or alloy steel constructionFrame Finish: Color coated (anti-rust powder coating) |
| 10 | Supplying & Fixing of Commercial grade Scott benchType: It is an adjustable Scott bench (preacher curl bench) designed for isolating and building bicep strength.Usage: It is primarily intended for use in commercial gyms due to its heavy-duty build.Material: The frame is typically made of durable steel with a color-coated finish.Max User Weight: Similar models like the WG 10 040 support a maximum user weight of up to 150 kg.Features: Features likely include comfortable, padded seating and an angled arm pad to ensure proper form and comfort during workouts |
| 11 | Supply of PEV Coated Round Rubber Dumbbells with steel handle. With following weight 2.5kg 5kg,10kg, 15kg as per required quantity at site |
| 12 | Supply of PEV Coated Rubber weight Plates with stainless steel ring of dia 50mm. With following weight 2.5kg 5kg,10kg, 15kg as per required quantity at site |
| 13 | Supply of PEV Coated Vanayal Kettlebell (Requirement of: 5kg*4pc ,) |
| 14 | Supply of Squatting Independent Racks |
| 15 | Supply of Weight-lifting belts with a 12 mm thickness (Size-M) as available in various materials like leather and neoprene, offering durability, core stability, and back support for heavy lifting. |
| 16 | Supply of Weight-lifting belts with a 5.5 mm thickness (Size-M) as available in various materials like leather and neoprene, offering durability, core stability, and back support for heavy lifting. |
| 17 | Supply of Foam Roller a cylindrical self-massage tool used to relieve muscle tightness, soreness, and inflammation by applying pressure to the body's connective tissue (fascia) |
| 18 | Supply of Gym Ball (65 CM) a versatile fitness accessory suitable for individuals approximately |
| 19 | Supply of Skipping ropes (or jump ropes) are essential tools for high-intensity cardiovascular workouts, helping to burn calories, improve agility, and build core strength. |
| 20 | Supply of Push Up Bar a versatile, portable fitness tool used to intensify bodyweight exercises, primarily targeting the chest, shoulders, triceps, and core muscles |
| 21 | Supply of a tri-fold exercise mat (dimension 180 X 60 X 0.8 Cub.cm) is a portable, padded fitness accessory designed for comfort and support during floor workouts, which folds into a compact shape with carrying handles for easy transport and storage. |
| 22 | Sub Head -IIUTCS Bldg. Vishwas Nagar, Refilling and replacement of Fire extinguishers |
| 23 | Emptying and re-filling of 4 kg capacity ABC portable type fire extinguisher i/c Hydro Static Pressure testing and submission of test report as per BIS: 2190: 2010 standard including loading unloading and cartage of extinguishers and reinstallation of the same back to the site. (pastage of refilling and validity slip on extinguishers) etc. as required. |
| 24 | Emptying and re-filling of 45 Ltr. Trolley water mist type fire extinguisher i/c Hydro Static Pressure testing and submission of test report as per BIS: 2190: 2010 standard including loading unloading and cartage of extinguishers and reinstallation of the same back to the site. (pastage of refilling and validity slip on extinguishers) etc. as required. |
| 25 | Emptying and re-filling of 50 kg capacity ABC Trolley type fire extinguisher i/c Hydro Static Pressure testing and submission of test report as per BIS: 2190: 2010 standard including loading unloading and cartage of extinguishers and reinstallation of the same back to the site. (pastage of refilling and validity slip on extinguishers) etc. as required. |
| 26 | Emptying and re-filling of 4.5 kg capacity CO2 portable type fire extinguisher i/c Hydro Static Pressure testing and submission of test report as per BIS: 2190: 2010 standard including loading unloading and cartage of extinguishers and reinstallation of the same back to the site. (pastage of refilling and validity slip on extinguishers) etc. as required. |
| 27 | Refilling of Clean Agent Type Capacity 4 Kg CE certified Fire Extinguisher filled with HFC 236FAClean Agent Gas. Etc. complete as required |
| 28 | Providing and fixing of 4.5Kg Carbon Dioxide type (Co2) fire extinguisher confirming to IS 15683 duly enamel painted fully charged, wheel release type valve, delivery hose horn locking arrangement, operating temperature: 30 Deg C to +55 Deg C i/c wall mounting MS. bracket etc. complete as required. i/c buy back as required |
| 29 | Providing & fixing of powder Fire Extinguisher stored Pressure type) capacity 6 kg duly ISI marked confirming to IS: 15683:2018, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe locking arrangement pressure gauge operation manual and bracket etc. i/c buy back as required |
| 30 | providing & Fixing of Clean Agent Type Capacity 6 Kg CE certified Fire Extinguisher filled with Clean Agent Gas. Etc. complete as required. i/c buy back as required |
| 31 | Sub Head -IIIRepairing, Servicing & Preventive maintenance of substation equipments UTCS bldg. |
| 32 | Repairing, servicing, decarbonising & testing of 630KVA, 11KV/433Volt, 3Phase, 50Hz, cast resin dry type Kirloskar Make indoor Transformer, cleaning and lowering the complete enclosure, HT, LT and safety box, checking and cleaning of HT/LT terminals, contacts and tapping with CRC-2-26/CTC, checking door opening safeties, temperature rise etc. i/c following tests - 1. Voltage Ratio Test, 2. Magnetic Balance Test 3. Magnetizing Current Test, 4. Insulation Resistance Test, 5. PI Value Test, 6. Winding Resistance Test, 7. Vector Group Test. |
| 33 | Repairing & servicing of 11KV/110Volt, 3 - Phase, Potential Transformer (PT) after dismantling the PT from the HT panel, replacement of worn out parts & 3Nos bottle type fuse suitable for 11KV/110Volt HT PT, Making suitable size and rating of copper bus bar connection i/c reinstallation, re connection, testing, commissioning etc. complete as required |
| 34 | Repairing & Servicing of existing 11KV, 630Amp, 50Hz, 3phase, horizontal draw out and horizontal isolation type vacuum circuit breaker (VCB) complete with removal from the HT panel board, dismantling /opening the required parts for servicing, checking, cleaning, testing & rectification of defects if any, setting right of main contacts, moving contacts, tripping and closing mechanism, oiling, greasing, assembling etc. complete as required. and decarbonising the fixed spout of panel after dismantling and refixing the same, oiling, greasing, assembling i/c servicing & repairing of rack in & rack out mechanical, replacement of broken / worn out parts and set right the same, complete mechanical and electrical testing of VCB i/c making the tripping and indication system workable by replacing and making good the control wiring, testing of Hi - Potential test, Insulation Resistance Test (IR), CRM Test, Breaker Trip timing, Breaker Close timing and Trip-Close timing test with suitable testing kit and instruments etc. complete. |
| 35 | Testing of the complete system of 11KV HT panel for checking the actual working of the CTs, their wiring, connected IDMT relay, shunt trip system, breaker's tripping system and for any loose connection by primary injection method in all three phases and at each plug setting at actual time multiplier at site with suitable testing equipment i/c rectify the defect in control wiring etc. if any, i/c calibration of relay set having by secondary injection method, cleaning the contacts, resetting with required accuracy complete with checking and set right the wiring etc. complete as reqd. complete as required. |
| 36 | Servicing, overhauling, cleaning & testing of draw out type 800 - 2000 Amp. capacity LT ACB i/c dismantling and replacing of minor components if required i/c reassembling of ACB replacing and checking of all tripping mechanism and cleaning of contact points and cleaning of carbon from main contact, tightening of loose connection, arc chute with CRC, checking the mechanical and electrical tripping system, greasing of moving mechanism, replacement of burnt / heated thimbles, nut, bolts, PVC tapping, testing of Hi - Potential test, Insulation Resistance Test (IR), CRM Test, Breaker Trip timing, Breaker Close timing and Trip-Close timing test with suitable testing kit and instruments complete as reqd. |
| 37 | Servicing, checking & cleaning of LT panel / Capacitor panel board (without servicing of LT ACB's) 3phase, 4wire, 50Hz, AC supply system comprising of outgoing feeders of rating varies from 100A to 630A i/c servicing of operating mechanism of all the switchgears, checking, cleaning & tightening of contacts of switchgears, tightening of cable end termination, replacement of burnt/heated thimbles, PVC taping etc. wherever reqd. |
| 38 | Providing & fixing power pack unit for protection and indication system of 11 KV HT Panel suitable for 24 Volt DC output with 230/110 Volt AC input supply having battery backup with built in charger, sealed maintenance free batteries, auto cut-off on full charge, protection fuse on input as well as on output i/c connecting on HT panel board, testing commissioning etc. complete i/c buyback as reqd. |
| 39 | Providing & fixing 100Watt, 230Volt strip type space heater with thermostat and temperature sensor in the existing 11KV HT Panel board i/c wiring, testing etc. Complete /c buyback as reqd. |
| 40 | SITC of LED Emergency Light Twin beam LED 10 watt each Specially use for providing direction having Exit Sign and Made by Powder Coates MS Housing light source, LED Should be Fixed On heat Shink for long life. Emergency Backup of upto 4 hours, 12V 7Ah Lead acid Maintenance free battery, SMPS Power Supply, working voltage 100V to 270 complete etc. i/c buyback as reqd. |
| 41 | Replacement of following electrical accessories in the existing capacitor /HT/ LT panel board i/c disconnection and dismantling the old worn-out accessories from the panel, testing, commissioning etc. complete as reqd. i/c buyback as required |
| 42 | LED indicating light Red/Yellow/Green |
| 43 | 3 Phase Digital Voltmeter of Size 96x96mm |
| 44 | 3 Phase Digital Ammeter of Size 96x96mm |
| 45 | 440V, Heavy Duty capacitor of different capacity as required in existing panel |
| 46 | Sub Head -IV10 KVA UPS at UTCS Building |
| 47 | Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery and suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity .................CONT........................ |
| 48 | (i.e. kw rating of the UPS shall be kva rating x 1) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non-condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, N6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3). The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 10 KVA |
| 49 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 50 | 8 way, Double door |
| 51 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 52 | Single pole |
| 53 | Supplying and fixing 63 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 54 | Double pole (63 AMP) |
| 55 | Supplying and fixing of following sizes of PVC trunking profile along with accessories fixing on wall surface and making good the same as required. |
| 56 | 50x 50 MM |
| 57 | Supplying & laying of one Number multi core flexible PVC outer sheathed copper conductor suitable for rated voltage of 1.1 KV grade ISI marked in following manners. |
| 58 | 3 x 10 sq. mm (in the existing open duct / existing channel /tray/pipe as required) |
| 59 | Credit for old dismantle materials like UPS, battery, Cables, and accessories etc. Complete with dismantling of equipments. Please Enable Macros to View BoQ information |