| 1 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 2 | Providing Sal wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 3 | Providing and fixing Second class teak wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 4 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately) 6 mm thick Cement bonded wood particle board as per IS:14276 as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 5 | Providing and fixing 50x50 mm (base and height) wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 6 | Renewing glass panes, with wooden fillets wherever necessary Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. (Saint-Gobain and Modi Guard) |
| 7 | Providing and fixing 100x10 mm aluminium tower bolts, ISI marked, (Heavy Duty) anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 8 | Providing and fixing 100 mm aluminium handles, ISI marked, (Heavy Duty) anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 9 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. (Tata/Jindal/Apollo or equivelent make). |
| 10 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 11 | Providing and fixing 0.62 mm thick prepainted steel sheet Tata Durashine or equivelent make (as approved by Engineer-In-Charge) in roofing with hot dipped metallic zinc / aluminium-zinc alloy coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 mocrons over 5 microns primer coating including fixing with self driven steel screws / prepainted iron J or L hooks or seam bolts with prepainted limpet and rubber washers complete with all accesoriees as required as per the detailed drawings and direction of Engineer-In-Charge including carriage of material upto all leads, lifts and heights. |
| 12 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 13 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 15 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 16 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 17 | Wall painting Two coats with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 18 | Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm) as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 19 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) including carriage of materials within all leads, lifts and heights. |
| 20 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 21 | Dismantling roofing including ridges, hips, valleys and gutters etc., and including stacking of serviceable materials in specified manners and disposal of unserviceable materials as per the direction of Engineer-In-Charge of G.I. Sheet including carriage of materials within all leads, lifts and heights. |
| 22 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking of serviceable materials in specified manners and disposal of unserviceable materials as per the direction of Engineer-In-Charge Of sectional area 40 square centimetres and above including carriage of materials within all leads, lifts and heights. |
| 23 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials in specified manners and disposal of unserviceable materials as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. |
| 24 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking in specified manners and disposal of unserviceable materials as per the dierction of Engineer-In-Charge including carriage of materials within all leads, lifts and heights. Please Enable Macros to View BoQ information |