| 1 | Supply of centrifugal mono pump set of KSB/Calama/Kirloskar/Johnson/Sabar/BE/Cromption make conforming to BIS:8034-1978 (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrel cage/slippering electric induction motor of same make as that of pump conforming to BIS: 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical, loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard, errection clamps, cable clips & depth gauge etc. The pump shall be suitable for operation on data on data given below :- |
| 2 | Nos. of pump required. 2 Nos pump |
| 3 | Capacity. 48.65 LPS for each pump |
| 4 | Static head in meters. 0.00 Metre |
| 5 | Total head in meter. 10.89 Metre |
| 6 | Length of rising main. Metres |
| 7 | Dia of Rising main. 350 mm dia G.I. pipe |
| 8 | Pumping hours per day. 8 Hours |
| 9 | Limits of pump operation. (-)25 % to (+ ) 10% of total head at duty point |
| 10 | Providing and installation of control panel as per Starter Panel KSB specifications and having protection of motor on occurance of faults. (triping on occurance of fault(s) i.e. Moisture, high motor temperature, dry running, reverse rotation, single phasing, voltage imbalance, overload and short circuit) as per site conditions and as per the direction of Engineer-in-charge. |
| 11 | Providing MS sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 65x65x6 mm duly painted comprising and capable of mounted the following accessories with all internal electric connection.as per site conditions and as per the direction of Engineer-in-charge. |
| 12 | Supply of Kirloiskar/Kilburn/IVC/Fouress/Glod Bhel/Leader//Bir valves/Kartar make Cast iron double flanged sluice valve (to be provided on delivery side) of size one step higher than the delivery size of pump and capable of with standing nominal seat test pressure of 10 Kg./Cm2 Class-300 BIS-780-1984.as per site conditions and as per the direction of Engineer-in-charge. |
| 13 | Supply of Kirloiskar/Kartar/Leader make Cast iron double flanged swing check type reflex valve having bye pass arrangement (to be provided on delivery side) of size one step higher than the delivery size of pump and shall be suitable for withstanding nominal seat pressure of 10 Kg./Cm2 as per BIS 5312-1984. (100mm dia) as per site conditions and as per the direction of Engineer-in-charge. |
| 14 | Providing and fixing Double flanged Leader/ Pelican/ Bhel/ Gled/ Kirloskar/ Kartar make 350mm Cast iron swing check type reflux valve in rising main pipe confirming to class IS:5312 PN 1.0, as per site conditions and as per the direction of Engineer-in-charge. |
| 15 | Providing and laying PVC insulated jointless,flat water proof copper cable of Finolex/Gloster make conforming to BIS: 1554 (Part-I)-1988 or latest with upto date ammendments of suitable size for the pump sets offered(One cable carrying all three phases) including all other electrical equipment/accessories such as thimble,flexible pipe solder,nuts & bolts cable gland etc. laid in pipe or trenches under floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities, it shall have to be replaced by the tenderer free of cost. (10mm2)as per site conditions and as per the direction of Engineer-in-charge. |
| 16 | From HPSEB meter to panel and panel to starters 10mm2 as per site conditions and as per the direction of Engineer-in-charge. |
| 17 | From starters to motor 6mm2 as per site conditions and as per the direction of Engineer-in-charge. |
| 18 | Providing and laying column assembly of GI/MSERW pipes of suitable size for suction delivery and common header considering site requirements and NPSH required/avaiable.The pipe sizes for suction and delivery shall as per the requirement of offered pump (to be given by the tendrers) and common header shall be equal to dia of rising main including tapers. flanges, bends, rubber gaskets, 3 mm thick nuts and bolts and special up to 5 metre away from the outer wall of pump house as per layout drawing approved by Engineer-in-charge. The pipes material shall conform to relevant BIS codes and capable of with standing field test pressure equal to 1.5 times the operating pressure. The complete arrangement shall comprise of:- a) Suction pipe 65mm dia of 2X10mtrs. length b) Delivery pipe 65mm dia of 2X5 mtrs length c) common header 100 mm dia of 5mtrs length.as per site conditions and as per the direction of Engineer-in-charge. |
| 19 | Errection of all equipments from Sr. No. 1 to 4 & 6 including cost of tees bends tapers and any other fittings required as per site conditions and as per the direction of Engineer-in-charge. |
| 20 | 1st Stage |
| 21 | Providng double flanged 125mm dia cast steel sluice valves ASA-300 of leader/ BHEL Kirlosker/ Kilburn GLED/ fourses make as per site conditions and as per the direction of Engineer-in-charge. |
| 22 | 2nd Stage |
| 23 | Providing and fixing Double flanged Leader/ Pelican/ Bhel/ Gled/ Kirloskar/ Kartar make 100mm dia Cast iron sluice valve in delivery side confirming to class IS:780 PN 1.0, as per site conditions and as per the direction of Engineer-in-charge. |
| 24 | Providng double flanged 80mm dia cast steel sluice valves ASA-300 of Leader/ Pelican/ Bhel/ Gled/ Kirloskar/ Kartar make make as per site conditions and as per the direction of Engineer-in-charge. |
| 25 | Providng double flanged 80mm dia cast steel reflux valove valves ASA-300 of Leader/ Pelican/ Bhel/ Gled/ Kirloskar/ Kartar make make as per site conditions and as per the direction of Engineer-in-charge. |
| 26 | Providing laying jointing and testing at site suitable size copper PVC insulated armoured power three and half core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens /Gloster/ ICC/ EICO/ National/IEC/ KI make . Suitable XLPE Unarmoured cable fromTransformer to Panel board / Motor ) as per site conditions and as per the direction of Engineer-in-charge. Please Enable Macros to View BoQ information |