Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way piano type switch,phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 5 | Providing & fixing of fresh lighting point (5-6 amp) exposed,using double locked PVC channel 25x2 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire (P+N+E) complete with P/F of switch 5/6 amps F/T to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point. |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in Surface/recessed pvc conduit as required. |
| 7 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 8 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 9 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 10 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 11 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 12 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 13 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 14 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 15 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 16 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 17 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 18 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 19 | Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 20 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/recessed steel/ PVC conduit. |
| 21 | 1 x 1.5 sq. mm |
| 22 | 2 x 1.5 sq. mm |
| 23 | 3 x 1.5 sq. mm |
| 24 | 4 x 1.5 sq. mm |
| 25 | 5 x 1.5 sq. mm |
| 26 | 6 x 1.5 sq. mm |
| 27 | 7 x 1.5 sq. mm |
| 28 | 8 x 1.5 sq. mm |
| 29 | 9 x 1.5 sq. mm |
| 30 | 10 x 1.5 sq. mm |
| 31 | 2 x 2.5 sq. mm |
| 32 | 3 x 2.5 sq. mm |
| 33 | 4 x 2.5 sq. mm |
| 34 | 5 x 2.5 sq. mm |
| 35 | 6 x 2.5 sq. mm |
| 36 | 7 x 2.5 sq. mm |
| 37 | 8 x 2.5 sq. mm |
| 38 | 9 x 2.5 sq. mm |
| 39 | 10 x 2.5 sq. mm |
| 40 | 2 x 4 sq. mm |
| 41 | 3 x 4 sq. mm |
| 42 | 4 x 4 sq. mm |
| 43 | 5 x 4 sq. mm |
| 44 | 6 x 4 sq. mm |
| 45 | 7 x 4 sq. mm |
| 46 | 8 x 4 sq. mm |
| 47 | 9 x 4 sq. mm |
| 48 | 10 x 4 sq. mm |
| 49 | 2 x 6 sq. mm |
| 50 | 3 x 6 sq. mm |
| 51 | 4 x 6 sq. mm |
| 52 | 5 x 6 sq. mm |
| 53 | 6 x 6 sq. mm |
| 54 | 7 x 6 sq. mm |
| 55 | 8 x 6 sq. mm |
| 56 | 9 x 6 sq. mm |
| 57 | 10 x 6 sq. mm |
| 58 | 1 x 10 sq. mm |
| 59 | 1 x 16 sq. mm |
| 60 | 2 x 25 sq. mm |
| 61 | 3 x 35 sq. mm |
| 62 | 4 x 50 sq. mm |
| 63 | 1 x 70 sq. mm |
| 64 | 1 x 95 sq. mm |
| 65 | Supplying and fixing of following sizes of medium class PVC conduit 2mm thick along with accessories in surface/recessed manner .the job also includes the cost of cutting the wall, rough plastering and making good the same in case of recessed conduit as required. |
| 66 | 20 mm |
| 67 | 25 mm |
| 68 | 32 mm |
| 69 | 40 mm |
| 70 | 50 mm |
| 71 | Supplying and Fixing 25 mm Double Locked PVC Channel 2 mm thick |
| 72 | Supplying and Fixing DLP PVC Trunking compartment along with accessories divider, extra cover, end caps, internal angles external angles, flat angles etc.25 mm Double Locked PVC Channel 2 mm thick |
| 73 | 50x80 |
| 74 | 50x105 |
| 75 | 50x130 |
| 76 | 50x145 |
| 77 | 50x180 |
| 78 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 79 | 75 mm X 75 mm X 60 mm deep |
| 80 | 100 mm X 100 mm X 60 mm deep |
| 81 | 150 mm X 75 mm X 60 mm deep |
| 82 | 150 mm X 150 mm X 60 mm deep |
| 83 | 180 mm X 100 mm X 60 mm deep |
| 84 | 200 mm X 125 mm X 60 mm deep |
| 85 | 200 mm X 150 mm X 60 mm deep |
| 86 | 200 mm X 150 mm X 75 mm deep |
| 87 | 200 mm X 250 mm X 60 mm deep |
| 88 | 200 mm X 250 mm X 75 mm deep |
| 89 | 200 mm X 150 mm X 100 mm deep |
| 90 | 200 mm X 250 mm X 100 mm deep |
| 91 | 200 mm X 300 mm X 60 mm deep |
| 92 | 200 mm X 300 mm X 100 mm deep |
| 93 | 250 mm X 300 mm X 60 mm deep |
| 94 | 250 mm X 300 mm X 100 mm deep |
| 95 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required |
| 96 | 5/6 amps switch |
| 97 | 2 way 5/6 A switch |
| 98 | 15/16 A switch |
| 99 | 3 pin 5/6 A socket outlet |
| 100 | 6 pin 15/16 A socket outlet |
| 101 | 5/6A 2 PinTOP |
| 102 | 5/6A 3 PinTOP |
| 103 | 16 A TOP |
| 104 | 15 A switch Socket Combine with out box |
| 105 | 15 A switch socket combine with box |
| 106 | Fan Regulator Stepped type 1 Module |
| 107 | Fan Regulator Stepped type 2 Module |
| 108 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 109 | 5/6 A switch |
| 110 | 2 way 5/6 A switch |
| 111 | 15/16 A switch |
| 112 | 3 pin 5/6 A socket outlet |
| 113 | 6 pin 15/16 A socket outlet |
| 114 | Bell push |
| 115 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 116 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 117 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular Switches in recess etc. as required. |
| 118 | 1 or 2 Module (75mmX75mm) |
| 119 | 3 Module (100mmX75mm) |
| 120 | 4 Module (125mmX75mm) |
| 121 | 6 Module (200mmX75mm) |
| 122 | 8 Module (125mmX125mm) |
| 123 | 12 Module (200mmX150mm) |
| 124 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 125 | 1 or 2 Module |
| 126 | 3 Module |
| 127 | 4 Module |
| 128 | 6 Module |
| 129 | 8 Module |
| 130 | 12 Module |
| 131 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 132 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 133 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 134 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 135 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including Connections etc. as required. |
| 136 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 137 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 138 | Providing and fixing following rating adjustable type and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 139 | 100A , 16 KA , DPMCCB |
| 140 | 100 A, 16 KA,TPMCCB |
| 141 | 125 A, 16 KA,TPMCCB |
| 142 | 150 A, 16 KA,TPMCCB |
| 143 | 200 A, 16 KA,TPMCCB |
| 144 | 200 A, 25 KA,TPMCCB |
| 145 | 250 A, 25 KA,TPMCCB |
| 146 | 250 A, 35 KA,TPMCCB |
| 147 | 315 A, 35 KA,TPMCCB |
| 148 | 400 A, 35 KA,TPMCCB |
| 149 | 500 A, 35 KA,TPMCCB |
| 150 | 630 A, 50 KA,TPMCCB |
| 151 | 800 A, 50 KA,TPMCCB |
| 152 | 63A , 16 KA , FPMCCB |
| 153 | 100 A,30KA,FPMCCB |
| 154 | 125 A,36KA,FPMCCB |
| 155 | 160A , 36KA , FPMCCB |
| 156 | 200 A,36KA,FPMCCB |
| 157 | 250 A,36KA,FPMCCB |
| 158 | 400 A,36KA,FPMCCB |
| 159 | 400 A,50KA,FPMCCB |
| 160 | 630 A,50KA,FPMCCB |
| 161 | 800 A, 50KA, FPMCCB |
| 162 | 1000 A, 50KA, FPMCCB |
| 163 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 164 | 6 way , Double door |
| 165 | 8 way , Double door |
| 166 | 12 way , Double door |
| 167 | 16 way, Double door |
| 168 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 169 | 4 way (4 + 12), Double door |
| 170 | 6 way (4 + 18), Double door |
| 171 | 8 way (4 + 24), Double door |
| 172 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 173 | 4 way (4 + 12), Double door |
| 174 | 8 way (4 + 24), Double door |
| 175 | 12 way (4 + 36), Double door |
| 176 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 177 | Single pole |
| 178 | Single pole and neutral |
| 179 | Double pole |
| 180 | Triple pole |
| 181 | Triple pole and neutral |
| 182 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 183 | a)40A TPN |
| 184 | b)63A TPN |
| 185 | c)40A TP |
| 186 | d)63A TP |
| 187 | e)40A DP |
| 188 | f)63A DP |
| 189 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 190 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 191 | Supplying and fixing TP sheet steel enclosure on surface/ recess each 848 along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required |
| 192 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 193 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 194 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 195 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 196 | Replacement/supply and fixing of following accessories |
| 197 | a) LED Lamp 9 watt with minimum lumens 900 |
| 198 | b) LED Lamp 12 watt with minimum lumens 1200 |
| 199 | Replacement/supply and fixing of following luminaries as specified below. |
| 200 | Surface type LED luminaries 12-16 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1000 with burning hours greater than 40000 Hourshaving system lumens =90 lm/watt |
| 201 | Surface type LED luminaries 15-20 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1200 with burning hours greater than 40000 Hours having system lumens =90 lm/watt |
| 202 | Hanging light (fancy type light) with 9-12 Watts LED Lamp |
| 203 | 10-12 Watt LED Bulkhead luminaire with burning hours >= 50000 Hours. |
| 204 | Recessed type LED luminaries 12-16 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 5500/6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1000 with burning hours >= 50000 Hours having system lumens =90 lm/watt |
| 205 | Recessed type LED luminaries 15-20 Watt circular/square type slim decorative aluminium casted and separate electronic driver with system temperature 6000/6500 K and robust construction in combination with flat diffuser with minium system Lumens 1200 with burning hours >= 50000 Hours having system lumens =90 lm/watt |
| 206 | 4 feet long LED batten 6000/6500k Light with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 4000 and maximum wattage24 including connection with multistrand copper conductor 3 core cable etc as required at site with burning hours >= 50000 Hours having system lumens 110 Lm/watt. |
| 207 | 4 feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 2000 and maximum wattage 20 including connection with multistrand copper conductor 3 core cable etc as required at sitewith burning hours >= 50000 Hours having system lumens 110 Lm/watt. |
| 208 | 2 feet long LED batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 1000 and maximum wattage 15 including connection with multistrand copper conductor 3 core cable etc as required at site with burning hours >= 50000 Hours having system lumens 110 Lm/watt. |
| 209 | 2'x2', 36-40W LED light fixture suitbale for ceiling recessed applications. The fixture has a power consumption of 36-40W and producing a system lumen output of minimum 3600 lumen. The fixture is designed for 50, 000 hrs of operational life Housing made of Metallic CRCA powder coated body Withstands 440Volt fast transit & Surge Protection 2KV. system Luminous efficieny 110 lm/ W, CRI> 80. The fixture has an operating voltage range 220-240V AC 50 Hz ,withstand 300Volt input for continuous operation & driver designed to withstand casing temperature of 85 degree C. |
| 210 | Providing and Fixing of 4x1 LED light panel with max 36-40 wattage, lumens/watt 100 |
| 211 | Providing fixing well glass lights 30 Watt 6000/6500k having high pressure diecast aluminum housing with poly carbonate antiglare diffuser including connection complete as required at site. (Surface Type) |
| 212 | Providing & Fixing 20W Spot Light Al. Housing Lu/W >= 100 Surface type |
| 213 | Dismantling and repair of LED batten by way repairing/replacing led driver and refitting the same in position after cleaning. |
| 214 | P/f of Phenolic Laminated Sheet 3 mm thick. |
| 215 | P/f of fibers sheet of following thickness. |
| 216 | a) 6 mm |
| 217 | b) 8 mm |
| 218 | c) 12 mm |
| 219 | P/f of Acrylic milky sheets of following thickness. |
| 220 | a) 2 mm |
| 221 | b) 3 mm |
| 222 | P/laying of 3 core flexible copper wire 2.5 mm sq. |
| 223 | P/laying of 3 core flexible copper wire 4 mm sq. |
| 224 | Supply and Fixing including making of connections complete job of 3P Contactor AC1 160A, AC3 130A, 240/440Volt. |
| 225 | Supply and Fixing including making of connections complete job of Contactor AC1 165A, AC3 130A, 240/440Volt. |
| 226 | Providing and fixing following rating of Manual Four pole, Onload, Front-operated Changeover Switch in existing Cubicle Panel or as per site requirement, making connections, etc. as required. The Job includes providing, fabrication, installation and commissioning of all Buses / items / accessories etc. as per the site requirement. |
| 227 | 100 A |
| 228 | 160 A |
| 229 | 200 A |
| 230 | 250 A |
| 231 | 1000A |
| 232 | 1250A |
| 233 | Providing and fixing of Spreader links for MCCB's |
| 234 | a) 4 links set for 125-200 A |
| 235 | c) 4 links set for 250A |
| 236 | d) 4 links set for 400A |
| 237 | d) 4 links set for 630A |
| 238 | P/F of MCB boxes (pvc) with strip |
| 239 | a) 2 way |
| 240 | b) 4 way |
| 241 | P/F of below mentioned Geyser accessories as per site requirements |
| 242 | a) P/f of connection pipes for Geysers of various sizes |
| 243 | b) Foundation nut bolts. |
| 244 | c) Geysers indicator. |
| 245 | c) Vocal copper tube. |
| 246 | d) Element copper glass. |
| 247 | e) Flange washer. |
| 248 | Replacement/Supplying and fixing of Geyser element 1500/2000 watts (power pack/prince/Theeta make) |
| 249 | a) Coil type (long) |
| 250 | b) Coil type (short) |
| 251 | c) Triangular type. |
| 252 | d) Round type. |
| 253 | e) Thermostat Geyser.(Long/short)(insertion type) |
| 254 | e) Thermostat Geyser.( Capillary type) |
| 255 | Replacement of Geyser element Coil type 2000 watts (for Venus Geysers) |
| 256 | Replacement of Geyser element Coil type 2000 watts (for Ferrolic geysers) |
| 257 | Replacement of Geyser element Coil type 2000 watts (for Havells geysers) |
| 258 | Replacement of Geyser element Coil type 3000 watts . |
| 259 | Replacement of Geyser element Coil type 6000 watts . |
| 260 | Servicing of Geyser by way of complete dismantling of all its accessories, removal of sludge / scale, thorough cleaning of all its parts, replacement of all worn-out/rusted/damaged Nuts/Bolts/Washers etc. and refixing of all parts of the geyser and making it operational. |
| 261 | i) without repair of Tank |
| 262 | ii) with repair of Tank |
| 263 | SITC of Electric Heater / Geyser of capacities as mentioned below with following parameters .1.Energy saving. 5 Star Certification by BEE 2. Provision of Temperature regulation by means of external Knob3. Power Rating:- 220/ 230V, 50 Hz, Single Phase. 4. Maximum Rated Pressure.= 8 bar 5. Installation Type Vertical / Horizontal mounted as per site requirement 6. Body Type:- Rust, water proof and Shock Proof outer body with attractive looks and corrosion resistant inner tank made of cold rolled steel ,resistant to hard water. 7. Element Type:- glass coated heating element to prevent from corrosion and hard water.8.Safety Valve maximum pressure =8 bar maximum9. Energy efficiency feature:- Should have high density PUF insulation for energy Saving10. Anti syphon system to prevent back flow of water. 11. Should have Indicating Lamps for ON & CUTT OFF.12. Conforming to :IS 2082:2018 , IS 302-1, IS 302-2-21 |
| 264 | a) 25 litre (2KW) |
| 265 | b) 35 litre (2KW) |
| 266 | c) 50 litre (2KW) |
| 267 | d) 100 litre (3KW) |
| 268 | a) Repairing of Blowers (heat Convectors) by way of changing internal wiring,screw, complete. |
| 269 | b) Repairing of Wall mount Blowers Electronic Type by changing internal wiring and relays etc |
| 270 | i) P/f heating coil 3 way, 4 way, 5 way. |
| 271 | ii) P/f of motor complete |
| 272 | iii) P/f of thermostat blower |
| 273 | iv) P/f of knob |
| 274 | v) Blower Switch |
| 275 | vi) Blower Fan |
| 276 | Providing and fixing of MS Plate – Grade IS2062 (2mm thick) having 4-6 holes to be fixed on wall by way of using Rawal Plug and screws duly painted with 2 coats of Red oxide and 2 coats of Paint of colour as per instructions of site engineer. The edges of the Plate are to be properly filed and the corners are to rounded by way of filing. |
| 277 | Suplying of wall mount heat convectors/ blower 230volt 50HZ Single phase 2000 watt with adjustable 3 heat setting, ,Auto thermal Cut ,Twin fan blade: 50degree, well balanced Copper conductors ,with a swing stand PVC Sheathed cord, 15A, 3 pin moulded plug |
| 278 | Rewinding of fans |
| 279 | a) Wall mount fan 400 mm |
| 280 | b) Ceiling fan |
| 281 | i) 1200 mm |
| 282 | ii) 1400 mm |
| 283 | Rewinding of exhaust fans of various sizes. |
| 284 | a) 9” |
| 285 | b) 12” |
| 286 | c) 15” |
| 287 | d) 24” |
| 288 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 289 | Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required. |
| 290 | P/f of accessories for various types of fans. |
| 291 | a) Ball bearing set |
| 292 | b) Capacitor/condenser. |
| 293 | c) Top lead. |
| 294 | d) Rubber bush. |
| 295 | e) Resistance. |
| 296 | f) Blades for all types of fans. |
| 297 | g) Gear griller. |
| 298 | h) Switch plate of wall mount fan. |
| 299 | i) Nut bolts. |
| 300 | j) Ceiling fan rod. |
| 301 | k) Ceiling fan clip. |
| 302 | l) Wall mount fan cover net. |
| 303 | Supply installation testing and commissioning of following sizes of metallic type exhaust fans with Bird guard to protect fan in running condition, Double ball bearing with Heavy duty motor. |
| 304 | i) 9\\" |
| 305 | ii) 12\\" |
| 306 | iii) 15\\" |
| 307 | ii) 18\\" |
| 308 | iii) 24\\" |
| 309 | Supply installation testing and commissioning of following sizes of plastic body exhaust fans shutter type with Heavy duty motor Rated speed = 1400 RPM . RAte voltage -220 to 240 Volts . |
| 310 | i) 150 mm |
| 311 | ii) 200 mm |
| 312 | ii) 225 mm |
| 313 | iii) 250 mm |
| 314 | iv) 300 mm |
| 315 | P/F of wooden frames of various sizes and making of holes for installing of exhaust fans complete with civil work in all respects for following size Exhaust Fans: |
| 316 | i) 12” |
| 317 | ii) 15” |
| 318 | iii) 18” |
| 319 | iv) 24” |
| 320 | P/f of fan hooks of various types S type, U type, J type. |
| 321 | Supplying and making end termination with Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 322 | 6 sq. mm |
| 323 | 10 sq. mm |
| 324 | 16 sq. mm |
| 325 | 25 sq. mm |
| 326 | 35 sq. mm |
| 327 | 50 sq. mm |
| 328 | 70 sq. mm |
| 329 | 95 sq. mm |
| 330 | 120 sq. mm |
| 331 | 150 sq. mm |
| 332 | 185 sq. mm |
| 333 | 240 sq. mm |
| 334 | 300 sq. mm |
| 335 | 400 sq. mm |
| 336 | 500 sq. mm |
| 337 | 630 sq. mm |
| 338 | 800 sq. mm |
| 339 | 1000 sq. mm |
| 340 | Supplying and making end termination with Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 341 | 6 sq. mm |
| 342 | 10 sq. mm |
| 343 | 16 sq. mm |
| 344 | 25 sq. mm |
| 345 | 35 sq. mm |
| 346 | 50 sq. mm |
| 347 | 70 sq. mm |
| 348 | 95 sq. mm |
| 349 | 120 sq. mm |
| 350 | 150 sq. mm |
| 351 | 185 sq. mm |
| 352 | 240 sq. mm |
| 353 | 300 sq. mm |
| 354 | 400 sq. mm |
| 355 | 500 sq. mm |
| 356 | 630 sq. mm |
| 357 | 800 sq. mm |
| 358 | 1000 sq. mm |
| 359 | Providing / fixing of Box made out of Sheet Steel (26 SWG) of suitable size consisting of clamp for resting of the MCB with Pole Clamp; the box is to be fixed on Pole. |
| 360 | SITC of Wall mount fans 400 mm with Plastic Body as specified below: 1.Motor AC 2.Governing standard I.S.2997 (Latest) 3.Power Consumption: Approx. 100 Watts4.Power supply Single phase AC 230V, 50Hz 5.Speed: 1200 -1400 rpm with regulator 6.Sweep: 400 mm 7.Air Flow: 72-80 m3/min. 8..motor protection through thermal9.overload protection device 10.It should have minimum 3 levels of speed control. Features:Suitable for mounting on walls with easy mounting system, Noise level shall be within limits adjustable upward and downward tilt mechanism |
| 361 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, Ceiling fan, BLDC type class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019),THD less than 10% and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 362 | Supply of led fixture 18-20W, LED Surface / Recess Mounted Downlighter with Round Shape having Die Cast Heat housing with HET Plastic Diffuser and minimum system lumen efficacy of 100 lm/W with P.F.>0.95 and THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70 ,CCT of 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV |
| 363 | Installation testing & commissioning of fans copper wound heavy duty. |
| 364 | a) Wall mount fans 400/300 mm |
| 365 | b) Ceiling fans 1200 mm |
| 366 | c) Exhaust fans double ball bearing |
| 367 | i) 9” |
| 368 | ii) 12” |
| 369 | iii) 15” |
| 370 | iv) 18” |
| 371 | v) 24” |
| 372 | Supplying and Fixing Snap On PVC Trunking compartment along with accessories divider, extra cover, end caps, internal angles external angles, flat angles etc. |
| 373 | 50x80mm |
| 374 | 50x105mm |
| 375 | Providing of Wireman |
| 376 | Providing of Highly Skilled |
| 377 | Providing of Electrician |
| 378 | Providing of Technician |
| 379 | Providing of Fitter, Grade 1 |
| 380 | Providing of Painter |
| 381 | Providing of Khallasi |
| 382 | Providing of Cable Jointer |
| 383 | Providing of Engineer |
| 384 | Providing of Software Engineer |
| 385 | External Electrification |
| 386 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 387 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required. |
| 388 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required. |
| 389 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 390 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 391 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 392 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 393 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 394 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 395 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 396 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 397 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 398 | a)Upto 35 sq. mm |
| 399 | b)Above 35 sq. mm and upto 95 sq. mm |
| 400 | c)Above 95 sq. mm and upto 185 sq. mm |
| 401 | d)Above 185 sq. mm and upto 400 sq. mm |
| 402 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 403 | a) Upto 35 sq. mm |
| 404 | b) Above 35 sq. mm and upto 95 sq. mm |
| 405 | c) Above 95 sq. mm and upto 185 sq. mm |
| 406 | d) Above 185 sq. mm and upto 400 sq. mm |
| 407 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 408 | a) Upto 35 sq. mm |
| 409 | b) Above 35 sq. mm and upto 95 sq. mm |
| 410 | c) Above 95 sq. mm and upto 185 sq. mm |
| 411 | d) Above 185 sq. mm and upto 400 sq. mm |
| 412 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 413 | a) Upto 35 sq. mm |
| 414 | b) Above 35 sq. mm and upto 95 sq. mm |
| 415 | c) Above 95 sq. mm and upto 185 sq. mm |
| 416 | d) Above 185 sq. mm and upto 400 sq. mm |
| 417 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 418 | a) Upto 35 sq. mm |
| 419 | b) Above 35 sq. mm and upto 95 sq. mm |
| 420 | c) Above 95 sq. mm and upto 185 sq. mm |
| 421 | d) Above 185 sq. mm and upto 400 sq. mm |
| 422 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 423 | a)Upto 35 sq. mm |
| 424 | b)Above 35 sq. mm and upto 95 sq. mm |
| 425 | c)Above 95 sq. mm and upto 185 sq. mm |
| 426 | d)Above 185 sq. mm and upto 400 sq. mm |
| 427 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 428 | a)Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 429 | b)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 430 | c)Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 431 | d)Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 432 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 433 | a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 434 | b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 435 | c) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 436 | d) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 437 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 438 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 439 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 440 | a) Upto 120 sq. mm |
| 441 | b) Above 120 sq. mm and upto 400 sq. mm |
| 442 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 443 | a) Upto 120 sq. mm |
| 444 | b) Above 120 sq. mm and upto 400 sq. mm |
| 445 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. |
| 446 | a) Upto 120 sq. mm |
| 447 | b) Above 120 sq. mm and upto 400 sq. mm |
| 448 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. |
| 449 | a) Upto 120 sq. mm |
| 450 | b) Above 120 sq. mm and upto 400 sq. mm |
| 451 | Laying of one number XLPE power cable of 33 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 452 | a) Upto 120 sq. mm |
| 453 | b) Above 120 sq. mm and upto 400 sq. mm |
| 454 | Laying of one number additional XLPE power cable of 33 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 455 | a) Upto 120 sq. mm |
| 456 | b) Above 120 sq. mm and upto 400 sq. mm |
| 457 | Laying of one number XLPE power cable of 33 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 458 | a) Upto 120 sq. mm |
| 459 | b) Above 120 sq. mm and upto 400 sq. mm |
| 460 | Laying of one number XLPE power cable of 33 KV grade of following size in the existing masonry open duct as required. |
| 461 | a) Upto 120 sq. mm |
| 462 | b) Above 120 sq. mm and upto 400 sq. mm |
| 463 | Disconnecting and extraction of following sizes existing LT cables PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade from existing masonry open duct,cable tray /cable hungers as required. |
| 464 | a) Upto 35 sq. mm |
| 465 | b) Above 35 sq. mm and upto 95 sq. mm |
| 466 | c) Above 95 sq. mm and upto 185 sq. mm |
| 467 | d) Above 185 sq. mm and upto 400 sq. mm |
| 468 | Excavation of existing cable trench for locating of cable fault by way of excavation , extractionremoving of cable from cable trench .the job includes cost of refilling the trench after rectifiying the cable fault. |
| 469 | a) Upto 35 sq. mm |
| 470 | b) Above 35 sq. mm and upto 95 sq. mm |
| 471 | c) Above 95 sq. mm and upto 185 sq. mm |
| 472 | d) Above 185 sq. mm and upto 400 sq. mm |
| 473 | LV CABLE JOINTING & END TERMINATION |
| 474 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 475 | 2 X 16 sq. mm |
| 476 | 2 X 25 sq. mm |
| 477 | 2 X 35 sq. mm |
| 478 | 2 X 50 sq. mm |
| 479 | 3 X 16 sq. mm |
| 480 | 3 X 25 sq. mm |
| 481 | 3 X 35 sq. mm |
| 482 | 3 X 50 sq. mm |
| 483 | 3 X 70 sq. mm |
| 484 | 3 X 95 sq. mm |
| 485 | 3 X 120 sq. mm |
| 486 | 3 X 150 sq. mm |
| 487 | 3 X 185 sq. mm |
| 488 | 3 X 225 sq. mm |
| 489 | 3 X 240 sq. mm |
| 490 | 3 X 300 sq. mm |
| 491 | 3½ X 25 sq. mm |
| 492 | 3½ X 35 sq. mm |
| 493 | 3½ X 50 sq. mm |
| 494 | 3½ X 70 sq. mm |
| 495 | 3½ X 95 sq. mm |
| 496 | 3½ X 120 sq. mm |
| 497 | 3½ X 150 sq. mm |
| 498 | 3½ X 185 sq. mm |
| 499 | 3½ X 225 sq. mm |
| 500 | 3½ X 240 sq. mm |
| 501 | 3½ X 300 sq. mm |
| 502 | 3½ X 400 sq. mm |
| 503 | 4 X 16 sq. mm |
| 504 | 4 X 25 sq. mm |
| 505 | 4 X 35 sq. mm |
| 506 | 4 X 50 sq. mm |
| 507 | Providing and laying of spans of 3 ½ core/2 core XLPE Al. cable Armored of various sizes as mentioned below in place of damaged/burnt out / fresh ones of 1.1KV as per IS 7098/ II/ 85 with latest amendements |
| 508 | 10 mm sq 2-core |
| 509 | 16 mm sq. 2-core |
| 510 | 25 mm sq. 2-core |
| 511 | 25 mm sq. 3 ½ core |
| 512 | 35 mm sq. 3 ½ core |
| 513 | 50 mm sq. 3 ½ core |
| 514 | 70 mm sq. 3 ½ core |
| 515 | 95 mm sq. 3 ½ core |
| 516 | 120 mm sq. 3 ½ core |
| 517 | 150mmsq. 3.5 core |
| 518 | 185mmsq 3.5 core |
| 519 | 240 mm sq. 3 ½ core |
| 520 | 300 mm sq. 3 ½ core |
| 521 | 400 mm sq. 3 ½ core |
| 522 | 500 mm sq. 3 ½ core |
| 523 | 630 mm sq. 3 ½ core |
| 524 | Supplying and making end termination with Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 525 | 6 sq. mm |
| 526 | 10 sq. mm |
| 527 | 16 sq. mm |
| 528 | 25 sq. mm |
| 529 | 35 sq. mm |
| 530 | 50 sq. mm |
| 531 | 70 sq. mm |
| 532 | 95 sq. mm |
| 533 | 120 sq. mm |
| 534 | 150 sq. mm |
| 535 | 185 sq. mm |
| 536 | 240 sq. mm |
| 537 | 300 sq. mm |
| 538 | 400 sq. mm |
| 539 | 500 sq. mm |
| 540 | 630 sq. mm |
| 541 | 800 sq. mm |
| 542 | 1000 sq. mm |
| 543 | Supplying and making end termination with Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 544 | 6 sq. mm |
| 545 | 10 sq. mm |
| 546 | 16 sq. mm |
| 547 | 25 sq. mm |
| 548 | 35 sq. mm |
| 549 | 50 sq. mm |
| 550 | 70 sq. mm |
| 551 | 95 sq. mm |
| 552 | 120 sq. mm |
| 553 | 150 sq. mm |
| 554 | 185 sq. mm |
| 555 | 240 sq. mm |
| 556 | 300 sq. mm |
| 557 | 400 sq. mm |
| 558 | 500 sq. mm |
| 559 | 630 sq. mm |
| 560 | 800 sq. mm |
| 561 | 1000 sq. mm |
| 562 | HV CABLE JOINTING & END TERMINATION |
| 563 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: |
| 564 | 70 - 95 sq. mm |
| 565 | 120 - 185 sq. mm |
| 566 | 240 -300 sq. mm |
| 567 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE alum conductor cable of 11 KV grade as required: |
| 568 | 70 - 95 sq. mm |
| 569 | 120 - 185 sq. mm |
| 570 | 240 -300 sq. mm |
| 571 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: |
| 572 | 70 - 95 sq. mm |
| 573 | 120 - 185 sq. mm |
| 574 | 240 -300 sq. mm |
| 575 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required: |
| 576 | 70 - 95 sq. mm |
| 577 | 120 - 185 sq. mm |
| 578 | 240 -300 sq. mm |
| 579 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required: |
| 580 | 70 - 95 sq. mm |
| 581 | 120 - 185 sq. mm |
| 582 | 240 -300 sq. mm |
| 583 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required |
| 584 | 70 - 95 sq. mm |
| 585 | 120 - 185 sq. mm |
| 586 | 240 -300 sq. mm |
| 587 | POLE ERECTION |
| 588 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 589 | Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/pipe not to be deducted) |
| 590 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 591 | a) 32 mm dia |
| 592 | b) 40 mm dia |
| 593 | LV OVER HEAD LINE WORK |
| 594 | Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required. |
| 595 | Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required. |
| 596 | Erection of galvanised 'D' iron clamps and insulator on pole as required. |
| 597 | Fixing of MV lightning arrestor as required. |
| 598 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) Bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 599 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres Length along the pole for protection of under ground cable as required. |
| 600 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 601 | Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 602 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. |
| 603 | Supply and erection of 75mm x 40mm x 6mm/100mmx50mmx 6mm channel iron cross-Arms including drilling holes for insulator pins & nuts and bolts and painting one coat of red Oxide and minimum two coats of Paint as required at site.( To be fabricated as per drawing /requirement at site) |
| 604 | Supply erection of angle iron of all sizes for structures/cross-Arms of sizes including drilling holes for insulator pins & nuts and bolts and painting one coat of red Oxide and minimum two coats of Paint as required at site.( To be fabricated as per drawing /requirement at site) |
| 605 | P/f of P.G clamp |
| 606 | a)0.05/0.05 |
| 607 | b)0.1/0.1 |
| 608 | Opening and dismantling cable/from change over switches or ACB’s from L.T panel after necessary repairing. Such new cable end terminals, dressing of cables, changing of rusty nut bolts cable gland, if found damaged/broken. |
| 609 | P/f of bus bar chamber (of appropriate size) TPN factory fabricated complete with lockable, hinged type door with Almunium busbar earthing nut bolt and painting powder coated, Heavy Duty |
| 610 | a)100 A 4 way |
| 611 | b) 200 A 8 ways |
| 612 | c) 250 A ---do--- |
| 613 | d) 400 A ---do--- |
| 614 | Supply and laying of following sizes of XLPE/ PVC insulated copper wire Unarmoured, overall PVC sheathed 1.1 KV grade cables |
| 615 | a) 25 mm sq single core |
| 616 | b) 35 mm sq single core |
| 617 | c) 50 mm sq single core |
| 618 | Opening, repairing, maintenance & general overhauling of servo stabilizer by way of detaching the core (using chain pulley block), removing of sludge from dimmerstat coils and other submerged parts and reinforcing the insulation wherever necessary. The job also includes servicing of servo mechanism, checking and rectification of gear synchronization system, automotive voltage regulator circuits, motorizing units and other allied electrical components. Replacement of damaged electrical and mechanical parts, complete servicing and over hauling (to be provided seperately). The job includes draining of T-oil, filtration and re-filling of the same at site. |
| 619 | a) 800 KVA |
| 620 | a) 750 KVA |
| 621 | b) 600 - 650 kVA |
| 622 | c) 400 KVA |
| 623 | d) 250/200 KVA |
| 624 | e) 100 KVA |
| 625 | Supplying and Replacement / Reparing of damaged electrical and mechanical parts, complete servicing and over hauling for above stabilizers |
| 626 | a)Ammeter selector switch |
| 627 | b)Input/out put selector switch |
| 628 | c)Electronic Control card complete for AC voltage stabilizers |
| 629 | d)Electro magnetic relay 24 Volt DC |
| 630 | e)Carbon brushes |
| 631 | f)Brush arm |
| 632 | g)Commutator tube and plug assembly |
| 633 | j)Bakalite core guide |
| 634 | h)Brass slip ring |
| 635 | i)Core guide assembly |
| 636 | j)Complete terminal stud. Assembly |
| 637 | k)Mica red fiber other insulating material |
| 638 | l)Brush arm assembly |
| 639 | m)Aluminum clamping assembly |
| 640 | n)Hand wheel |
| 641 | o)Limit switch lower with push button |
| 642 | p)Limit switch higher with push button |
| 643 | q)E-point plates |
| 644 | r)Dimmer base fiber plates for coils |
| 645 | s)Insulator Dimmer spacers |
| 646 | t)Terminal Brush |
| 647 | u) P/f of 10 kg torque 220 volt AC servo motor for stabilizers |
| 648 | Providing, fabrication and fixing of checkered M.S.Iron Plate of following thickness. |
| 649 | 6mm thick |
| 650 | P/f of CT of following ratings with tapings (AE/Kappa make) Resin cast for LT Panels |
| 651 | a) 200/5A |
| 652 | b) 250/5A |
| 653 | c) 400/5A |
| 654 | d) 600/5A |
| 655 | e) 1000/5A |
| 656 | a) P/f of Digital voltmeter 0-500 volt |
| 657 | b) P/f of Digital Am-meter of 0-500 A |
| 658 | Providing of below mentioned items for maintenance of electric equipments |
| 659 | a) Petroleum Jelly |
| 660 | b) Carbon tetrachloride CCl4 |
| 661 | Repairing of transformer by way of changing Bush rods, bushes etc on H.T/L.T side.and cleaning The job includes providing and fixing of insulated gaskets, rubberized cork washers, nuts and bolts etc. after draining of oil from the transformer and re-filling of the same after complete inspection.(For 630/1000 KVA) |
| 662 | Providing and fixing of full threaded nuts and bolts of various sizes. |
| 663 | Providing/ fixing of Pad clamps for 630 KVA |
| 664 | Providing/ fixing of Pad clamps for 1000 KVA |
| 665 | Providing/filling of Xmer oil filtered |
| 666 | Filtration of Transformer Oil with transportation; filtration to be carried out at site. |
| 667 | Providing/filling of Silica gel in the breather |
| 668 | Providing of LT porcelain bushes with bush cups.for 630 KVA |
| 669 | Providing of LT bush rods for 630 KVA X-mers. |
| 670 | Providing, laying and fixing following dia RCC pipe NP2 class(light duty) in ground complete with RCC collars, jointing withcement mortar 1:2 (1 cement : 2 fine sand) including trenching(75 cm deep) and refilling etc as required. |
| 671 | a)150 mm dia |
| 672 | b)250 mm dia |
| 673 | c)300mm dia |
| 674 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 675 | c)40mm |
| 676 | b)50mm |
| 677 | c)100mm |
| 678 | d)150mm |
| 679 | Providing and laying of PVC pipe B-class of following size. |
| 680 | 50mm dia |
| 681 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 682 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 683 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 684 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 685 | 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 686 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 687 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. |
| 688 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 689 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 690 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 691 | 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 692 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 693 | 33KV VCB |
| 694 | Rectification,Re-Alignment,setting right the electrical section of 33 kV breakers which includes replacement of damaged parts. 33KV C & R Panel |
| 695 | Rectification,Re-Alignment,setting right the mechanical section of 33 kV breakers which includes replacement of damaged parts. 33KV C & R Panel |
| 696 | Replacement of damaged clamps (Bi-metallic) confirming to IS :1285 standards for 33KV VCB , 33KV LA ,33KV Isolator |
| 697 | Replacement of damaged equipments (33 kV VCB bushes complete assembly) conforming to IS:2099 standards. |
| 698 | Replacement of damaged equipments (33 kV HV bushes of transformers complete assembly) conforming to IS:2099 standards. |
| 699 | Replacement of damaged equipments (11 kV LV bushes of transformers complete assembly) confirming to IS:2099 standards. |
| 700 | Replacement of damaged equipments (33 kV P.T bushes of transformers complete assembly) conforming to IS:2099 standards. |
| 701 | Replacement of damaged equipments (33 kV C.T bushes of transformers complete assembly) conforming to IS:2099 standards. |
| 702 | Repairing of following electric 33 kV Gang operating switch by way of cleaning, mopping with petroleum jelly, changing of rusty nut bolts, link pieces, rods, clips etc. as per site requirement. |
| 703 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm X 60 cm ), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required |
| 704 | Providing and Fixing of Guy Wire 7/14 SWG |
| 705 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30KV(rms) and nominal discharge current rating of 10 KA (Station class ) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 706 | Providing and fixing of following size GI pipes (C Class) complete with all allied items including Tees, Elbows, Sockets, union etc. as required: |
| 707 | Providing and fixing of following size PVC pipes (B Class) complete with all allied items including Tees, Elbows, Sockets, union etc. as required: |
| 708 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 709 | Supplying and erection of three piece nonlinear resistor type lightning arrestor (Station Type) suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 10 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 710 | Supplying and erection of 200A 11KV Dropout fuse unit with 80 amp fuses, galvanised channel, Post type insulator, tinned copper contacts complete in all respects (post type) |
| 711 | Providing and Fixing of 33 KV Pin insulator |
| 712 | Providing and Fixing of 33 KV pin with washers/nuts (Galvanized) |
| 713 | Supply and erection of 33 KV,3 pole Horizontal mounting type Isolator double break with post type insulators with earth switch (assembled) confirming to IS 9921( pt 1:5) & other relevent IS with latest ammendements with galvanised channels post type insulators , tinned copper contacts , arching horns, GI operating Handle with locking arrangements etc. complete as required at site. |
| 714 | Supplying & installing 11 KV 3 phase, 200 Amp. Vertical type gang operated switch with hot dip galvanised channels post type, insulator, tinned copper contacts, arcing horns, GI pipe gang operating handle, limit switch etc. locking arrangements etc. complete in all respects. |
| 715 | Supply mechanical and manual transportation and erection of following size ST pole complete with base plate & top cap conforming to IS 2713 with up-to-date ammendments complete with 2 coats of red oxide coat and 2 coats of aluminium paint (silver colour). The job includes cost of stone pad alongwith cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required as per REC standard (0.45 cum for 7 mtr. pole, 0.5 cum for 9 mtr. pole, 0.6 cum for 11 mtr. pole, 0.7 cum for 13 mtr. pole and 1.0 cum for 16 mtr. pole. The job includes cost, laying and fixing of 40 mm dia, 3 mtr. long, GI pipe strip of size 25 × 3 mm for pole earthing. |
| 716 | 8 Mtr. Long Pole (ST-410 SP15) |
| 717 | 9 Mtr. Long Pole (ST-410 SP33) |
| 718 | 11 Mtr. Long Pole (ST-410 SP56) |
| 719 | 13 Mtr. Long Pole (ST-410 SP69) |
| 720 | 16 Mtr. Long Pole (ST-410 SP80) |
| 721 | Supply & Erection of flange mounted 6mtrs long hot dip galvanized Octangonal Pole of following height made from 3 mm thick HT Steel plate, having top dia-70mm & bottom dia of 130 mm complete with average coating thickness of atleast 65 micron. The galvanizing shall be done in single dipping. There shall not be any circumferential welding. Pole shall have door of approximate 300 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. Pole shall have galvanized base plate of size 220 mm x 220mm x 12 mm thick with provision of holes for 4 no. 20mm dia bolt. including supplying and fixing the following in the window box provided for cable termination a) Supplying and fixing 6mm thick laminated mounted sheet inside the window mounted and including Earthing complete by G.I Pipe 40mm or G.I Rod 20mm 2.5 Mtr long through G.I Strip. b) Supplying and fixing 63 Amps terminal block, suitable for 10 sq.mm conductor- 04 nos & shorting links- 05 nos. on DIN Channel including providing and fixing DIN Channel of suitable length- 01 nos on the existing laminated sheet. c) Supplying and fixing 6 Amps, SP MCB, “C” curve 10 KA- 02 nos, Earth stud 02 nos, welded at suitable height, washers, springs washers & nuts. |
| 722 | Supply fixing of galvanized pole bracket (arms) of approved design suitable for above mentioned /existing pole completed in all respects with proper fabrication for installation of above street lighting fittings on the top of steel tubular poles.a) Double arm 1 meter long with an angle as per requirement. (Arm) |
| 723 | b) Single arm 1 meter long with an angle as per requirement. (Arm) |
| 724 | Providing, installation, testing and commissioning of LED Street light luminaire as per following specifications:1. Input voltage : 150 V to 270 V 2. LDE lamp efficiency : Min 95 to 110 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 70-80 W 7. Luminous flux : 7000 to 8000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture |
| 725 | Providing & making RCC foundation of 1300mm(H) × 600mm × 600mm size with 1:2:4 (1Cement, 2 Coarse, 4 Stone aggregate) complete with 12mm dia. M.S. bar for reinforcement along with centering & shuttering i/c supplying & fixing 600mm long , 16mm dia J type G.I, coated foundation bolt/ Anchor bolt with template suitable for ornamental / 6.0mtr octogonal Pole.The job includes cost of 100mm dia 600mm length corgated pipe complete with excavation the soil & refilling, ramming, curing etc. as reqd. For 06 meter Octogonal Galvanized Pole |
| 726 | Providing, installation, testing and commissioning of LED Street light luminaire as per following specifications:1. Input voltage : 150 V to 270 V 2. System efficiency : Min 100 to 110 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 40-50 W 7. Luminous flux : 4000 to 5000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture |
| 727 | Supply, installation, testing and commisioning of LED flood light luminaries in place of existing non functional High mask Lights as per following specification 1. Input voltage : 150 V to 270 V2.Lumens : Min 105003. Power factor : >0.904. Life expecting : more than 40,000 hours5. No of hours usage / day : 10 to 12 hours/day6. Rated watt : 110-120W7. Luminous flux : 10500 to 12000 lumens8. Colour Temperature : 5,500 to 6,500 K with test certificate9. Ingress protection : IP 65/IP 66 as per IS/IEC60529-2001 with test certificate10. Total harmonic distortion (THD): <15% with test certificate11. Colour rendering index : Ra > 8012. Working Temperature : 0 deg to 50 deg13. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture |
| 728 | Repairing/maintenance of electrical fittings of various types by way of opening /dismantling and changing of led Driver refitting after making necessary complete as per site requirement. From steel poles of height |
| 729 | upto 4.5 metre |
| 730 | Above 4.5 metre and upto 7 metre |
| 731 | Above 7 metre and upto 9 metre |
| 732 | Repairing/maintenance of electrical fittings by way of opening /dismantling, changing of led Driver refitting after making necessary complete as per site requirement. |
| 733 | 180-190 Watt, IP66 High Mast LED fittings for High Mast Pole |
| 734 | 200-220 Watt, IP66 High Mast LED fittings for High Mast Pole |
| 735 | MISC. CIVIL ITEMS |
| 736 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 737 | All kinds of soil : |
| 738 | 1 meter from cutting edge |
| 739 | 25 meter beyond 1 m from cutting edge |
| 740 | 50 meter beyond 1m from cutting edge |
| 741 | Ordinary Rock |
| 742 | 1 meter from cutting edge |
| 743 | 25 meter beyond 1 m from cutting edge |
| 744 | 50 meter beyond 1m from cutting edge |
| 745 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 746 | Deduct for not consolidation by ramming and watering while re-filling with sand and or good soil in cable/ pipe laying. |
| 747 | CEMENT CONCRETE (CAST-IN-SITU)Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: |
| 748 | 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 749 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 750 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) |
| 751 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 752 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 753 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 754 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 755 | Centering and shuttering including strutting, propping etc. and removal of form work for:4.6.1 Foundations, footings, bases for columns |
| 756 | REINFORCED CEMENT CONCRETE Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level |
| 757 | 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 758 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 759 | CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix: |
| 760 | 1 : 4 (1 cement : 4 fine sand) |
| 761 | 1 : 6 (1 cement : 6 fine sand) |
| 762 | Supply, laying, testing and commissioning of 20 mm² ACSR Conductor (Squirrel) |
| 763 | Supply, laying, testing and commissioning of 30 mm² ACSR Conductor (Weasel) |
| 764 | Supply, laying, testing and commissioning of 50 mm² ACSR Conductor (Rabbit) |
| 765 | Supply, laying, testing and commissioning of 100 mm² ACSR Conductor (Dog) |
| 766 | Supply, laying, testing and commissioning of 150 mm² ACSR Conductor (Wolf) |
| 767 | Supply, laying, testing and commissioning of 200 mm² ACSR Conductor (Panther) |
| 768 | Supply, laying, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 769 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 770 | Pipe-Type Chemical earthing which includes digging a suitablesized pit in which a 3 Metre long copper pipe is inserted vertically and the pit is back-filled by a mixture of charcoal, salt, and bentonite in a ratio so as to achieve earth value of less thhan 2 ohms. |
| 771 | Suppy, installation, testing and commissioning of 11 kV Isolator Double Break, 3-pole, 630 Amps, Horizontal Mounting Type , with earth switch |
| 772 | Supply, installation, testing and commissioning of pure sine-wave, 1kVA, Inverter |
| 773 | Supply, installation, testing and commissioning of pure sine-wave, 2kVA, Inverter |
| 774 | Supply, fixing, testing and commissioning of Multistrand, Flexible, PVC-insulated, 1.1kV Copper Conductor, Heat-resistant, Flame-retardant, Cable of following sizes: |
| 775 | a) 25 sq. mm |
| 776 | a) 35 sq. mm |
| 777 | a) 50 sq. mm |
| 778 | b) 70 sq. mm |
| 779 | c) 95 sq. mm |
| 780 | b) 120 sq. mm |
| 781 | c) 150 sq. mm |
| 782 | c) 185 sq. mm |
| 783 | DG SETS |
| 784 | Cleaning of exhaust pipes silencers with using of chemicals and cleaning of exhaust smoke from inner sides of pipes for avoiding of over heating of DG sets. The job includes dismantling of fluntch nuts and bolts including replacement of gaskets etc of below mention DG sets. |
| 785 | 320 kVA |
| 786 | 380 kVA |
| 787 | 600 kVA |
| 788 | Repairing, cleaning of different capacities of below mentioned DG set radiators by way of using chemical and radiwash AX1013358 for DG Sets etc. The job includes repairing of damaged tubes by way of using soldering etc including replacement of upper and lower gaskets at site, also refixing the same on existing foundation of below mention DG sets. |
| 789 | 320 KVA |
| 790 | 380 KVA |
| 791 | 600 KVA |
| 792 | Repairing of Cylinder heads of 320/380 KVA D.G Set (Cummins Make) by way of dismantalling and refixing at site after repairing at workshop .The job includes valve griding incuding its transportation and loading and unloading. |
| 793 | Replacement of following items of Cylinder heads |
| 794 | 320 KVA DG set |
| 795 | a) Valve intake and Exhaust |
| 796 | b) Guide valve |
| 797 | c) Head Gasket Set (Complete set ) |
| 798 | 380 KVA |
| 799 | a) Valve intake and Exhaust |
| 800 | b) Guide valve |
| 801 | c) Head Gasket Set (Complete set ) |
| 802 | Opening & Repairing of DC 24 Volt Dynamo by way of replacement of below mentioned parts by new one in place of existing out of order parts at work shop. The job includes cost of refixing. |
| 803 | Repairing of armature |
| 804 | Carbon brushes set |
| 805 | Belt Dynamo |
| 806 | Brush holder |
| 807 | Bearings |
| 808 | Opening & Repairing of Self starters of 380 KVA DG set, 320 KVA DG sets (Cummins make) by way of complete dismantling checking repairing refixing including transportation up to work shop for checking of damaged parts. The job includes replacement of below mention parts by new one as under. |
| 809 | Solenoid switch |
| 810 | Carbon brushes |
| 811 | Self Bendix |
| 812 | Repairing of comutator |
| 813 | Brush holder |
| 814 | Main coils |
| 815 | Bush (3 Nos) |
| 816 | Kelly boush |
| 817 | Drive accessories |
| 818 | Repairing of Turbo chargers of different models and capacity Cummins make DG sets by way of complete opening and refixing of minor/major new kits in place of existing out of order and non functional parts on below mention DG sets as under. |
| 819 | 320 KVA |
| 820 | Minor Kit |
| 821 | Major kit |
| 822 | 380 KVA |
| 823 | Minor kit |
| 824 | Major kit |
| 825 | 600 KVA |
| 826 | Minor kit |
| 827 | Major kit |
| 828 | Servicing/checking of Stanford/Kirloskar/Caterpillar alternator 380/320 KVA DG’s set by way of complete checking of starter and field coils, in let and out let connections. The job includes filling of greasing to the bearings, two coats of recommended varnishing to the coils with the help of skilled persons. |
| 829 | 320KVA |
| 830 | 380KVA |
| 831 | 600KVA |
| 832 | Repairing of AMF panel of 380 KVA DG set by way of checking of all AC and DC wiring connections with the help of skilled persons the job includes replacement of below mentioned items by new one as under. |
| 833 | AC Relay MSP 4P 240 A (saizer make) |
| 834 | DC Relay Omron My 2N -24 DC |
| 835 | Bakelite HRC fuses 6 AMP |
| 836 | HRC fuse RT-14-20-500V 1690W 2A |
| 837 | HRC fuse RT-14-20-500V 1690W10A |
| 838 | Earth fault relay 230 Vac (Teknik make) |
| 839 | Delay time relay (Teknik make) |
| 840 | Repair of 24/48 volt boost and trickle type battery charger by of way replacement of below mentioned new one in place non -functional ones. The job includes handling transportation loading and un loading as required |
| 841 | a) Diode |
| 842 | b) Rotary switch |
| 843 | c) voltmeter |
| 844 | d) ammeter |
| 845 | e) Battery Terminal (PVC Type ) |
| 846 | f) Kit Kat 63Amp |
| 847 | g) Indicator Lamp |
| 848 | h) Mcb Single pole |
| 849 | i) Boost and trickle Switch |
| 850 | e) rewinding of coil Ac/DC |
| 851 | Tappet setting of different DG sets of various models and make, the job includes repairing and setting right of rocker arms nuts and bolts, exhaust intake and injectors nuts and bolts (adjusting screws). The job also includes replacement of rocker arm gaskets and tappet cover gaskets with “O” rings including dismantling and refixing at site of below mentions DG sets. |
| 852 | 320 KVA DG set. |
| 853 | 380 KVA DG set. |
| 854 | 600 KVA DG set. |
| 855 | Repairing of different capacity DG set PT pumps including replacement of all worn out /out of order/non -functional parts by new one in place of existing out of order parts. The job includes dismantling and refixing at site providing and fixing of new gaskets including setting right of timing between engine and pumps of below mention DG sets. |
| 856 | 62.5 KVA DG set. |
| 857 | 200 KVA DG set. |
| 858 | 320 KVA DG set. |
| 859 | 380 KVA DG set. |
| 860 | 600 KVA DG set. |
| 861 | Repairing of different capacity DG set injectors(Cummins) by way of replacement of all parts by new one in place of existing out of order parts, the job includes dismantling and refixing of these injectors of below mentioned DG sets. |
| 862 | 320 KVA DG set. |
| 863 | 380 KVA DG set. |
| 864 | 600 KVA DG set. |
| 865 | Repairing of different capacity DG sets Electronic Activator including replacement of all parts by new one in place of existing out of order parts. The job includes dismantling and refixing at site providing and fixing of new gasket of below mention DG sets Cummins make Activator of below mention DG sets. |
| 866 | 1. 320 KVA DG set |
| 867 | 2. 380 KVA DG set |
| 868 | 3 600 KVA DG set |
| 869 | Supply, fixing testing and commissioning of IEVR 3 pieces and 1 piece for below mentioned DG sets by new one in place of existing out of order. The job includes dismantling of existing one and refixing of new with the help of skilled persons at site. |
| 870 | 200 KVA DG set IVER |
| 871 | 320 KVA DG set IVER |
| 872 | 380 KVA –d0- |
| 873 | 600 KVA –d0- |
| 874 | Supply handling transportation loading and un loading of below mentioned items for various capacities for smooth running of Dg sets of below mentioned items. (Caterpillar make DG) |
| 875 | Engine Oil (Cat DEO Cl4 15W-40 ) |
| 876 | Coolant (ELC Premix ) |
| 877 | Supply handling transportation loading and un loading of below mentioned items for various capacities for smooth running of DG sets of below mentioned items. (Cummins make DG) |
| 878 | c) M.oil premium Blue 15 W 40 CH4 API (P50000006) |
| 879 | d) K.oil super (P 82-030-10-0-20) |
| 880 | e) Distilled water |
| 881 | f) Sulphuric acid (concentrated) |
| 882 | g) Inhibiter corrosion Coolant |
| 883 | Replacement of in let hose pipe with clamp |
| 884 | Replacement of Out let turbo charger hose with clamp |
| 885 | Replacement of M oil in let pipe |
| 886 | Replacement of M oil out let pipe |
| 887 | Supply and fixing of Rubber packing of 1pieces for coupler of DG set Alternator and Engine as per site requirement |
| 888 | Supply and fixing of Bolts for coupler |
| 889 | Repairing of HSD/water pipe in the all DG sets by way of replacement of below mention parts by new one in place of existing out of order as under by way of P/F of G.I fittings C-class |
| 890 | a) Elbow with dia ½” / ¾” |
| 891 | b) Tee with dia ½” / ¾” |
| 892 | c) Socket with dia ½” / ¾” |
| 893 | d) Union with dia ½” / ¾” |
| 894 | e) Nipple with length 2” /4” /6” (with dia 1/2”) |
| 895 | f) Nipple with length 2” 4” 6” (with dia 3/4”) |
| 896 | g) Dead plug ½” / ¾” |
| 897 | h) Ball value ½” |
| 898 | i) Ball value ¾” |
| 899 | j) Elbow with dia 1” |
| 900 | k) Tee with dia 1” |
| 901 | l) Socket with dia 1” |
| 902 | m) Union with dia 1” |
| 903 | n) Nipple with length 2” /4” /6” (with dia 1”) |
| 904 | o) Ball value 1\\" |
| 905 | P/l of G.I pipes B-class 20’ long |
| 906 | i) ½” pipe 20’ long |
| 907 | ii) ¾” pipe 20’ long |
| 908 | iii) 1” pipe 20’ long |
| 909 | P/F of C.P accessories |
| 910 | a) Angle value ( ½”) |
| 911 | a) Angle value (¾”) |
| 912 | a) Angle value ( 1”) |
| 913 | b) Bib cock ( ½”) |
| 914 | Repairing of rolling shutters long/short by way repairing of rolling drum , side plates ,safety cover refixing including welding/nut bolt and greasing and checking of damaged parts. |
| 915 | lifting spring of suitable size |
| 916 | Lifting gear box compete upper and lower |
| 917 | Side channels as per site |
| 918 | Lifting handle |
| 919 | Lifting gear rod as per site |
| 920 | Repairing/complete rewinding of (1 HP) self-priming motor. The job includes dismantling/refixing etc. including transportation to workshop and vice versa. |
| 921 | Repairing/complete rewinding of (2 HP) self-priming motor. The job includes dismantling/refixing etc. including transportation to workshop and vice versa. |
| 922 | Supply, Fixing, Testing and commissioning of complete synthetic hose / rubber kit high pressure for 320/380 DG sets. The job includes fixing of suitable clamps as per the site requirement. |
| 923 | long size |
| 924 | short size |
| 925 | Dismantling, opening and repair of 24 volt self starters from 320 KVA DG sets for checking of damaged parts etc. This job includes its transportation loading un loading including refixing at site. (Cummins make DG sets) |
| 926 | Replacement of below mentioned parts by new one in place of existing out of order and non functional. |
| 927 | 1. Armature long size (Hypo/Locust make). |
| 928 | 2. Main coils |
| 929 | 3. Auxiliary coils |
| 930 | 4. Carbon brush’s |
| 931 | 5. Brush holder |
| 932 | 6. Celey(killi) bush |
| 933 | 7. Big bush. |
| 934 | 8. Contacts male and female |
| 935 | 9. Clutch Plate |
| 936 | 10. Main gear |
| 937 | 11. Solenoid switch. |
| 938 | 12. Connection bolts in let and out let |
| 939 | 13. Complete rewinding of commutater and armature. |
| 940 | Supply, installation, testing and commissioning of 12V, 100Ah Sealed Lead Acid Battery |
| 941 | Supply, installation, testing and commissioning of 12V, 150Ah Sealed Lead Acid Battery |
| 942 | Supply, installation, testing and commissioning of 12V, 180Ah Sealed Lead Acid Battery |
| 943 | Supply, installation, testing and commissioning of 12V, 200Ah Sealed Lead Acid Battery |
| 944 | Supply, installation, testing and commissioning of 12V, 220Ah Sealed Lead Acid Battery |
| 945 | Supply, installation, testing and commissioning of 12V, Battery Charger with following specifications:i) Input Voltage: 200 - 240V (ac)ii) Phase: Single-Phaseiii) Charging Current: 15A (max).iv) Protection Rating: IP54The Battery Charging Equipment shall be float-cum-Boost type. Battery Charging Equipment shall be fully automatic for Float and Boost charging facility with suitable indication on front of the panel by means of LED indication. The manual mode should be fully independent so that no element of electronic controller comes into its operation. This shall also include an independent full wave bridge rectifier of suitable rating, output of which will be connected to load and battery by means of a contactor controlled switch on the front panel. Output of the charger in manual mode shall be maintained below 35 volts by means of selector switch connecting the suitable tap on the secondary side of power transformer by the operator. Facility should be provided to prevent the excessive in-rush current into the battery, when the discharged battery suddenly comes across the float charger after an emergency period. |
| 946 | Supply, installation, testing and commissioning of 12/24/48V Battery Charger with following specifications:i) Input Voltage: 200 - 240V (ac)ii) Phase: Single-Phaseiii) Charging Current: 25A (max).iv) Protection Rating: IP54The Battery Charging Equipment shall be float-cum-Boost type. Battery Charging Equipment shall be fully automatic for Float and Boost charging facility with suitable indication on front of the panel by means of LED indication. The manual mode should be fully independent so that no element of electronic controller comes into its operation. This shall also include an independent full wave bridge rectifier of suitable rating, output of which will be connected to load and battery by means of a contactor controlled switch on the front panel. Output of the charger in manual mode shall be maintained below 35 volts by means of selector switch connecting the suitable tap on the secondary side of power transformer by the operator. Facility should be provided to prevent the excessive in-rush current into the battery, when the discharged battery suddenly comes across the float charger after an emergency period. |
| 947 | Carrying out Repair / Servicing / M. Oil changing of 750kVA DG Set (Cummins, KTA38) by way of draining of exhaust M-oil from oil chamber, filters etc. including cleaning all parts by way of filling of new M-oil after complete cleaning all related parts at site of below mentioned DG sets by way of fixing of new filters as under; replacement of existing damaged/worn-out parts etc. by way of complete cleaning of all related parts and subsequent providing and installation of new parts as detailed below: |
| 948 | a) Control Card (Item # A028T766) |
| 949 | b) Control Sym Display, Eng Txt, CB BT (Item # 0300-6315-02) |
| 950 | c) Control Card (Item # A054J968) |
| 951 | d) Foil sealed Test Strips CC2602B (Item #3403800) |
| 952 | e) Calibration Charges |
| 953 | f) Labour Charges |
| 954 | g) Element (Lube Oil Filter) (Item# 3889310) |
| 955 | h) Fuel Water Separator (Item #4095189) |
| 956 | i) Kit Air Cleaner Element, (K, QSK, V Series) (Item # 3238665) |
| 957 | j) M Oil Premium Blue 15 W 40 CH4 API |
| 958 | k) Dhoti Cloth |
| 959 | l) Inhibiter corrosion Coolant |
| 960 | Carrying out Repair / Servicing / M. Oil changing of 200kVA DG Set (Cummins, 6CTA) by way of draining of exhaust M-oil from oil chamber, filters etc. including cleaning all parts by way of filling of new M-oil after complete cleaning all related parts at site of below mentioned DG sets by way of fixing of new filters as under; replacement of existing damaged/worn-out parts etc. by way of complete cleaning of all related parts and subsequent providing and installation of new parts as detailed below: |
| 961 | a) Control Card (Item # A0327-1617-01) |
| 962 | b) Control Assy(Item # 0300-6014) |
| 963 | c) Foil sealed Test Strips CC2602B (Item #3403800) |
| 964 | d) Calibration Charges |
| 965 | e) Labour Charges |
| 966 | f) B Check Kit (6CTA) (Item # 3238543) |
| 967 | g) Kit Air Cleaner Element (Item # 3238667) |
| 968 | h) Dhoti Cloth |
| 969 | i) M Oil Premium Blue 15 W 40 CH4 API |
| 970 | j) Inhibiter corrosion Coolant |
| 971 | Carrying out Repair / Servicing / M. Oil changing of 62.5VA DG Set (Cummins, S3.8) by way of draining of exhaust M-oil from oil chamber, filters etc. including cleaning all parts by way of filling of new M-oil after complete cleaning all related parts at site of below mentioned DG sets by way of fixing of new filters as under; replacement of existing damaged/worn-out parts etc. by way of complete cleaning of all related parts and subsequent providing and installation of new parts as detailed below: |
| 972 | a) Automatic Voltage Regulator, AS440 (Item # E000-24403) |
| 973 | c) Foil sealed Test Strips CC2602B (Item #3403800) |
| 974 | d) Element - Oil Filter (Item # 0122-0962) |
| 975 | e) Labour Charges |
| 976 | f) Separator, Fuel Water (Item # 5591392) |
| 977 | g) Kit Air Cleaner Element (Item # 3238666) |
| 978 | h) Dhoti Cloth |
| 979 | i) Inhibiter corrosion Coolant |
| 980 | j) M Oil Premium Blue 15 W 40 CH4 API |
| 981 | Carrying out Repair / Servicing / M. Oil changing of 600kVA DG Set (Cummins, KTA) by way of draining of exhaust M-oil from oil chamber, filters etc. including cleaning all parts by way of filling of new M-oil after complete cleaning all related parts at site of below mentioned DG sets by way of fixing of new filters as under; replacement of existing damaged/worn-out parts etc. by way of complete cleaning of all related parts and subsequent providing and installation of new parts as detailed below: |
| 982 | a) B Check Kit for 6PCB-II, KTAA19 (Item # 3238628) |
| 983 | b) Control Card (Item # A028T766) |
| 984 | c) Control Sym Display, Eng Txt, CB BT (Item # 0300-6315-02) |
| 985 | d) Control Card (Item # A054J968) |
| 986 | e) Calibration Charges |
| 987 | f) Foil sealed Test Strips CC2602B (Item #3403800) |
| 988 | g) Element - Oil Filter (Item # 0122-0962) |
| 989 | h) Labour Charges |
| 990 | i) Separator, Fuel Water (Item # 5591392) |
| 991 | j) Kit Air Cleaner Element, (K, QSK, V Series) (Item # 3238665) |
| 992 | k) M Oil Premium Blue 15 W 40 CH4 API |
| 993 | l) Dhoti Cloth |
| 994 | m) Inhibiter corrosion Coolant |
| 995 | Carrying out Repair / Servicing / M. Oil changing of 380kVA DG Set (Cummins, NTA-14-G3) by way of draining of exhaust M-oil from oil chamber, filters etc. including cleaning all parts by way of filling of new M-oil after complete cleaning all related parts at site of below mentioned DG sets by way of fixing of new filters as under; replacement of existing damaged/worn-out parts etc. by way of complete cleaning of all related parts and subsequent providing and installation of new parts as detailed below: |
| 996 | a) B Check Kit (Item # 3238545) |
| 997 | b) Automatic Voltage Regulator, AS440 (Item # E000-24403) |
| 998 | b) Control Panel (Item # 4083935) |
| 999 | e) Calibration Charges |
| 1000 | f) Foil sealed Test Strips CC2602B (Item #3403800) |
| 1001 | h) Labour Charges |
| 1002 | j) Kit Air Cleaner Element (Item # 3238358) |
| 1003 | k) M Oil Premium Blue 15 W 40 CH4 API |
| 1004 | l) Dhoti Cloth |
| 1005 | m) Inhibiter corrosion Coolant |
| 1006 | Carrying out Repair / Servicing / M. Oil changing of 600kVA DG Set (Gainwell-CAT, C18) by way of draining of exhaust M-oil from oil chamber, filters etc. including cleaning all parts by way of filling of new M-oil after complete cleaning all related parts at site of below mentioned DG sets by way of fixing of new filters as under; replacement of existing damaged/worn-out parts etc. by way of complete cleaning of all related parts and subsequent providing and installation of new parts as detailed below: |
| 1007 | a) Complete Kit (FLKt WO Oil-500H) (Item # C18PM2FKT) |
| 1008 | b) CAT Deco C14 15W-40 PAIL (3E9848) |
| 1009 | c) Coolant (ELC Premix) (Item # 4692718) |
| 1010 | d) Air Filter (Item # 2697041) |
| 1011 | Replacement of below-mentioned items of 600kVA DG Set (Gainwell-CAT, C18) by way of removing existing item(s), followed by thorough cleaning/checking/testing (as recommended by the OEM) by way of supply, installation, testing and commissioning of Fresh/New One and re-commissioning of the DG Set (complete job) |
| 1012 | e) Alternator G (Item # 5N5692) |
| 1013 | b) Regulator-TE (Item # 2477133) |
| 1014 | c) Motor GP EL (Item # 3496530) |
| 1015 | d) Hose (Item # 2647111) |
| 1016 | e) Hose (Item # 2647112) |
| 1017 | f) Hose-Hump (Item # 6090377) |
| 1018 | g) Hose (Item # 2303396) |
| 1019 | h) Clamp (Item # 1270929) |
| 1020 | i) Module Controller (Item 5180014) |
| 1021 | j) Regulator - R150 (Item # 5638421) |
| 1022 | k) Clamp (Item # 9X2201) |
| 1023 | l) Vee Belt (Item # 4N8216) |
| 1024 | m) Vee Belt Set (Item # 3525646) |
| 1025 | n) Element AS-P (Item # 2697041) |
| 1026 | Providing of Highly Skilled |
| 1027 | Replacement of complete Hose kits, synthetic / rubber alongwith suitable clamps to below mentioned DG sets (Cummins) by new ones in place of existing damaged ones. The job includes dismantling, subsequent thorough cleaning of the associated parts, thereafter re-fixing the new ones at site and commissionin gof the DG set: |
| 1028 | 62.5 kVA DG Set |
| 1029 | 200 kVA DG Set |
| 1030 | 380 kVA DG Set |
| 1031 | 600 kVA DG Set |
| 1032 | 750 kVA DG Set |
| 1033 | Repairing of DG set canopy doors by way of replacement of damaged links and locks by way of replacement of hinges / locks etc. |
| 1034 | i) Hinge |
| 1035 | ii) Locks Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail