| 1 | Schedule 'A' Part-I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. |
| 2 | Lumpsum price worked out by the contractor for Construction of single men barrack for JCO/ORs (01 JCO+01 Hav+26 ORs) with permanent specification in G+2 building with RCC M-30 grade concrete including all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Lump sum price worked out by the Contractor for “EXCAVATION AND EARTHWORK / DEVELOPMENT OF SITE\\" as listed in Schedule ‘A’ Part - II representing __________ % __________________ percent Above / Below the lump sum price of `4,54,345.55 inserted by the MES in Schedule ‘A’ Part - II |
| 4 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of `16,24,818.00 inserted by the MES in Schedule ‘A’ Part - III |
| 5 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of ₹3,41,448.19 inserted by the MES in Schedule ‘A’ Part - IV |
| 6 | Lump sum price worked out by the Contractor for “ROAD” as listed in Schedule ‘A’ Part - V representing ________ % ____________ percent Above / Below the lump sum price of ₹11,88,323.10 inserted by the MES in Schedule ‘A’ Part - V |
| 7 | Lump sum price worked out by the Contractor for “HARDSTANDING” as listed in Schedule ‘A’ Part - VI representing __________ % ____________ percent Above / Below the lump sum price of ₹4,08,809.20 inserted by the MES in Schedule ‘A’ Part - VI |
| 8 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `1,12,592.50 inserted by the MES in Schedule ‘A’ Part - VII |
| 9 | Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - VIII representing _________ % __________________ percent Above / Below the lump sum price of `17,25,737.50 inserted by the MES in Schedule ‘A’ Part - VIII |
| 10 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IX representing __________ % _________________ percent Above / Below the lump sum price of ₹55,882.35 inserted by the MES in Schedule ‘A’ Part - IX |
| 11 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - X representing __________ % _________________ percent Above / Below the lump sum price of ₹36,591.00 inserted by the MES in Schedule ‘A’ Part - X |
| 12 | Lump sum price worked out by the Contractor for “WATER COOLER AND REFRIGERATOR” as listed in Schedule ‘A’ Part - XI representing __________ % _________________ percent Above / Below the lump sum price of ₹27,438.00 inserted by the MES in Schedule ‘A’ Part - XI |
| 13 | Schedule 'A' Part-XIIThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 13.00 to 54.00. |
| 14 | EXCAVATION AND EARTHWORK / DEVELOPMENT OF SITEM&L for moorum / red bajri filling in floors or pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 15 | Excavation in trenches not exceeding 1.5 mtr deep and 1.5 mtr width as in hard dense soil complete all as specified and directed.Note: NO JCB excavation is permitted for earth work. |
| 16 | Returning filling including leveling watering and well ramming in layer not exceeding 25cm thick complete all as specified and directed. |
| 17 | Removal of surface soil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 18 | M&L for removing the hardstanding / cutting floor inside the substation / E/M installations / path for laying of cables of any size complete all as specified and directed. |
| 19 | INTERNAL ELECTRIFICATIONS&F, LED light fittings 1 x 18/20 W, 4 ft, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. |
| 20 | S&F, LED light fittings 1 x 9/10 W, 2 ft, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. |
| 21 | S&F, LED wall mounted study lamb fittings 1 x 9/10 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. |
| 22 | S&F, LED street light fittings 35 Watts, 230 Volts, AC outdoor type high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant including thermal management in multiple optics complete with IP-66 protection and GI pipe 1.5m bend to shape to fix in wall through proper clamps, nuts, bolts with washers connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 23 | S&F, exhaust fan heavy duty steel body 300mm sweep, 230 volts, 50 Hz, 1200 RPM including louvers shutter, copper wire complete all as specified and directed. |
| 24 | S&F, exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50 Hz, 1200 RPM, copper wire and sweep 250mm complete all as specified and directed. |
| 25 | S&F, wall fan 400mm double strings oscilating type 220/240 Volts, 50 Hz, single phase AC 1350 RPM copper motor PF 0.9 (min) not more than 65 Watts air delivery not less than 65mm as per site requirement as required complete all as specified and directed. |
| 26 | S&F, single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB of capacity 20 Amps complete all as specified and directed. |
| 27 | SEWAGE DISPOSALProvision of LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil PCC 1:4:8 below the vent shaft connection etc for 30 users complete all as specified and directed. |
| 28 | Provision of soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25 / SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 x 6.00mtr depth complete all as specified and directed. |
| 29 | EXTERNAL WATER SUPPLYCutting the exisitng GI/CI pipe of size 80/100mm dia, inserting tee of size 100 x 100 x 80mm for taking branch connection including necessary threading, earth work, returning, refilling etc; complete all as specified and directed. |
| 30 | Construction of brick masonry valve pit of internal dimension 60 x 60 x 60cm depth with sub class 'B' bricks in CM (1:4) and 10mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:4:8) type CI (using 20mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6mm angle iron and 6mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, two coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed. |
| 31 | M&L for cutting of PCC/Hard standing / WBM road not exceeding 45cm in width not exceeding 75cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e. bitumen / PCC (1:3:6) type C1 complete all as specified and directed. |
| 32 | EXTERNAL ELECTRIFICATIONSupply, installing, testing & commissioning, factory made and tested LT feeder pillar box (KIOSK) 1500mm x 1200 x 700mm size, outdoor type, platform mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminum bus bars 300 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type with aprons for cable entry and fixing |
| 33 | danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indiated in Hindi & English with double door shutter and locking arrangement (including provision of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 Sqmm. The platform shall be such that it is of a height 45cm above the nearest road level including connections of all outgoing / incoming |
| 34 | connections of cables, necessary brick foundation with plastering to the panel board, all outgoing feeders shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint and taking out of old skelton type panel with control switches complete all as specified and as directed Engineer-in-Charge. The scope of work includes the following:-Note: LT panel board should be as per IS/ICE 61439-Part I & II type test certificates. Panel builder should submit all certificates before executing the job. |
| 35 | (1) Incoming:(i) MCCB 4 pole, thermal magnetic 200A, breaking capacity 36 KA, 415 V, 50 Hz with OL, SC, protection - 01 No alongwith spreader terminals.(ii) Digital voltmeter 0-500 volts with selector switch - 01 No.(iii) Digital Ampmeter 0-300 Amps with selector switch & CT - 01 No.(iv) Indicator lamp LED type (R, Y, B) complete with fuse - 01 Set. |
| 36 | (2) Outgoing:(i) MCCB 4 pole, thermal magnetic 160A, breaking capacity 25 KA, 415 V, 50 Hz with OL, SC, protection - 01 No alongwith spreader terminals.(ii) MCCB 4 pole, thermal magnetic 63A, breaking capacity 16 KA, 415 V, 50 Hz with OL, SC, protection - 01 No alongwith spreader terminals.(iii) MCB TPN 40 Amps C-Curve 10KA - 1 No.(iv) MCB TPN 16 Amps C-Curve 10KA - 1 No. |
| 37 | M&L for extending the extisting LT panel board at substation with 2.0mm thick CRCA sheet factory made indoor type totally enclosed weather dust and vermin proof as per IS, CPRI approved with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 300 Amps with necessary supporting insulators so as to match with the existing LT panel board / distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of existing panel / bus bar including necessary supporting frame / channel fix through existing cable trench from ground with comprising of the following:- |
| 38 | (a) MCCB 200 Amps, 4 pole, 36KA, Ics-100% of Icu - 01 No.(b) Provision for outgoing cable of size upto 120 sqmm from the extended portion of LT distribution panel. |
| 39 | Supplying, laying, jointing, testing & commissioning of LT XLPE cables, insulated, screened, PVC bedded, galvanized steel stranded armoured, electric power cable (heavy duty) with aluminium conductor, 1100 Volt graded of 120 Sqmm 3.5 core cross sectional area laid in trenches complete all as specified and directed. |
| 40 | Supplying, laying, jointing, testing & commissioning of LT XLPE cables, insulated, screened, PVC bedded, galvanized steel stranded armoured, electric power cable (heavy duty) with aluminium conductor, 1100 Volt graded of 35 Sqmm 3.5 core cross sectional area laid in trenches complete all as specified and directed. |
| 41 | Supplying, laying, jointing, testing & commissioning of LT XLPE cables, insulated, screened, PVC bedded, galvanized steel stranded armoured, electric power cable (heavy duty) with aluminium conductor, 1100 Volt graded of 16 Sqmm 4 core cross sectional area laid in trenches complete all as specified and directed. |
| 42 | Supplying, laying, jointing, testing & commissioning of LT XLPE cables, insulated, screened, PVC bedded, galvanized steel stranded armoured, electric power cable (heavy duty) with aluminium conductor, 1100 Volt graded of 6 Sqmm 2 core cross sectional area laid in trenches complete all as specified and directed.Note for Sl item Nos. 33 to 36:(i) Rate include the cost of lug of proper size and cable gland.(ii) Necessary excavation, PCC cover and sand cushioning shall be measured and paid separately. |
| 43 | M&L for river washed and screened, dry sand for filling in trenches below 8cm laid before laying of cable and 15cm sand cable laid after laying the cable and around underground cables for cushioning of cables complete all as specified and directed. |
| 44 | M&L for laying LV unreinforced precast concrete cable cover but type 2, flat size 300mm x 180mm x 40mm complete all as specified and directed. |
| 45 | M&L for PCC 1:4:8 type D2 40mm graded aggregate complete for making good to the excvated portion of Road / Hardstanding at road crossing etc., in foundation (below pole) complete all as specified and directed. |
| 46 | M&L for PCC 1:3:6 type C1 20mm graded aggregate complete for making good to the excvated portion of Road / Hardstanding at road crossing etc., for foundation of pole etc; (around the poles in pit) complete all as specified and directed. |
| 47 | M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate for coping of poles including necessary form work, fair finishing to exposed surfaces using extra cement complete all as specified and directed. |
| 48 | M&L for LT cable route indicator for underground cable indication complete all as specified and directed. |
| 49 | Supply & laying, 50mm bore galvanised steel tubing, light grade, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / in drains / fixed to poles / walls (with required size flat iron clamp bolts, nuts and washers) pipes complete all as specified and directed. |
| 50 | Supply & laying, 80mm bore galvanised steel tubing, light grade, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / in drains / fixed to poles / walls (with required size flat iron clamp bolts, nuts and washers) pipes complete all as specified and directed. |
| 51 | S&F, LED street light fitting 60 watts, 140 V - 270 V, 50Hz AC outdoor type with high pressure die cast aluminium housing with top opening service and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, light source high efficiency long life LED package modules on MCPCB with LED lumen efficacy of >140 lumen per watt, Electronic Driver Powered by Built-in, isolated electronic LED driver (SMPS |
| 52 | based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection, 10 kV surge protection, Surge Voltage protection & other safety tests as per IS 15885 Part-2/Sec13 completed to driver with superior finish with top maintainable driver compartment complete with the fittings with two pairs of necessary nuts and bolts with washers with suitable packing (GI pipe light grade 32/40mm bore 200mm length) arrangement to fixing with bracket including unserviceable same lights deposited to MES yard for repairing complete all as specified and directed by Engineer-in-Charge.Note: LM 79 and 80 test certificate submitted before executing of the work. |
| 53 | S&F, energy saving, environment friendly, pole mounting 40W, LED, post top luminaire suitable to pole of OD 76mm, aesthetically designed with symmetrical light distribution made up of die cast aluminium spigot for mounting of LED driver spun aluminium cnopy Uv protected landscape for effective thermal management, toughend glass with IP 65 protection and IK 07 impact resistance, operating voltage 140 to 270 Volts, SPD of 4KV minimum, at least 90% driver efficiency, SMD LED, PF ≥ 0.95, light colour 5700K or higher, including fixing arrangement by nuts, bolts and washers and connection with FRPVC insulated copper conductor of size 2 x 1.5 sqmm and 1 x 1.5 sqmm |
| 54 | as earth wire minimum certified warranty three years with service support complete all as specified and directed. |
| 55 | S&F, mounting bracket made of 40mm bore (or higher size to suit the opening of fitting) light grade GI pipe of approx. 1.5mtr length bent to shape of 1mtr and fixed to pole with FI 40mm x 6mm clamps, 02 Nos and suitable size necessary nuts & bolts, including bracket complete set painting of two coat red oxide and aluminium painted fittings for street lights with swaged tubular pole connected complete all as specified and directed. |
| 56 | S&F, one runs of three core 1.5 Sqmm x 3 core (nominal area) PVC insulated and PVC sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade confirming to IS:7098 drawn through pipe / pole for connecting to street light and pole JB with lugs complete all as specified and directed. |
| 57 | S&F, galvanised steel tubing, light grade, IS-1239 marked with all fittings (IS marked) complete fixed on pole using suitable clamps nuts & bolts (not less than 03 Nos) complete all as specified and directed. |
| 58 | Supplying, transporting to site, erecting & fixing in position, steel tubular swaged and welded poles of overall height 9 metres, type 410 SP-31, IS-2713 marked with mild steel base plate (fillet welded to poles), pole cap / finial taper plug, bolts, nuts, washers etc, including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete and painting 05 Nos band / strips with fluorescent, PO box red synthetic enamel paint (30cm wide each) at a distance of 30cm from plinth block of colour black and green with numbering of poles, complete all as specified and directed. |
| 59 | Note: Poles shall be swaged and welded at manufacturer’s factory and not at site. The inner surface shall be factory painted. |
| 60 | S&F, pole mounting type junction box factory made of minimum size 290 x 200 x 100mm of FRP sheet duly powder coated with front openable hinged door, locking arrangements, with 04 Nos aluminium bus bars 40 Amps rating mounted on SMC / porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA suitable for domestic loading - 01 No. including mild steel flat iron clamp and and supporting flat iron made out of 40 x 4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 61 | WATER COOLER AND REFRIGERATORSupply, install, testing & commisioning of water cooler 80 ltr storage and 40 ltr cooling capacity per hour, single phase complete all as specified and directed. |
| 62 | S&F, refrigerator, electric driven (single phase), capacity more than 360 litres upto 460 litres BEE 5 star rated, frost free complete all as specified and directed. |
| 63 | S&F, voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed. Please Enable Macros to View BoQ information |