|
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. area n exc 10 sqm on plan and getting out in soft/loose soil all as directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide, exc 1.5m and n exc 3.00m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. area n exc 10 sqm on plan in depth and getting out in soft/loose soil all as directed. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layer n.exc 25cm thick each layer complete all as specified and directed. |
| 4 | Removing excavated soil to a distance not exc 50m away and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 5 | Demolition or breaking up 150 mm drain pipes (SGSW/ AC/reinforced concrete) set in cement mortar and taking out from trenches all as directed by Engineer-in-Charge. |
| 6 | Demolition or breaking up 200 mm drain pipes (SGSW/ AC/reinforced concrete) set in cement mortar and taking out from trenches all as directed by Engineer-in-Charge. |
| 7 | M&L for SGSW pipes 150mm bore grade 'A' including laying pipes at levels or to falls In trenches, on concrete bed including necessary extra joints, waste and cutting complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for RCC drain pipes NP3, 150mm bore including laying at pipes level or to falls in trenches, on concrete bed including necessary extra joints, waste and cutting complete with collars as specified and directed. |
| 9 | M&L for RCC drain pipes NP3, 200mm bore including laying pipes level or to falls in trenches, on concrete bed including all necessary extra joints, waste and cutting as jointed complete with collars as specified and directed. |
| 10 | M&L for 100mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in concrete bed, width of concrete bedding shall extend laterally 15 cm beyond either side of the outer dia of pipe laid to falls in trenches in any depth including packing under, and haunching against the sides of pipes NP3 150mm bore, after the pipes have been laid and tested including necessary shuttering and supports to concrete and for laying beds to falls complete all as specified and directed. |
| 11 | M&L for 150mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as concrete bed, width of concrete bedding shall extend laterally 15 cm beyond either side of the outer dia of pipe laid to falls in trenches in any depth including packing under, and haunching against the sides of pipes NP3, 200mm bore, after the pipes have been laid and tested including necessary shuttering and supports to concrete and for laying beds to falls complete all as specified and directed. |
| 12 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc of any description and in any position complete all as specified and directed. |
| 13 | M&L brick work with fly ash brick straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 14 | All as per Srl item No 13 here-in-before but except bricks. |
| 15 | M&L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick wall built in cement morter 1:4 complete all as specified and directed. |
| 16 | All as per Srl item No 15 here-in-before but except bricks. |
| 17 | M&L for raking out joints and pointing to brick work in walls or to bricks on edge in floors, surface channels, roof etc in CM 1:4 complete all as specified and directed. |
| 18 | Taking down cement plaster, any description on brick or concrete surface or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc removing the rubbish off the premises to a distance not exc 50 mtr away complete all as specified and directed. |
| 19 | M&L rendering 15mm thick on fair face of brick or concrete surface in CM 1:4 finished even and fair without using extra cement complete all as specified and directed. |
| 20 | M&L for prepration of newly plastered/un plastered surfaces of wall and applying two coats of white wash complete all as specified and directed. |
| 21 | Demolition reinforced cement concrete of any description and in any position not otherwise specically provided (reinfocement cut as required to facilitate demolition) and removing the demolished material to low lying areas to a distance not exceeding 50 mtr away complete all as specified and directed. |
| 22 | M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exc 200mm thick (horizontal or sloping) for culvert all as specified and directed. |
| 23 | M&L for pre cast RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as cover slab for manhole and similar work (culverts) etc. complete all as specified and directed. |
| 24 | M&L for TMT bars 6 to 8mm dia and over cut to length bent to shape required including crancking spirally for hooking ends and binding with and including MS wire annealed n. less than 0.9mm dia complete all as specified. |
| 25 | M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in mass concrete foundation of manhole complete all as specified and directed. |
| 26 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channel and drain including forming fair finished drain or channel any girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified. |
| 27 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified and directed. |
| 28 | M&L for removal of blockage between manhole to manhole lines of various size & at any depth for sewage by means (rodding, manually or any other means) including removing rugs of any type dirt etc complete all as specified and directed. |
| 29 | M&L for cleaning of blockage of WC Indian or European type by removing of all the mud/sludge and getting out including cleaning pipe upto first manhole and depositing the sludge in a pit of suitable size at a distance not exceeding 50 meters from the WC and covering the same with the soil obtained from excavation of pit including all excavation and earth work complete all as specified and directed by Engr-in-Charge |
| 30 | M&L for cleaning the blockage of bathroom/kitchen by cleaning the nahni traps/gully traps of all the mud/sludge and getting out, washing thoroughly grating of tarp, CI waste pipes by opening the clearing eyes and depositing the sludge in a pit of suitable size at a distance not exceeding 50 meters from the gully trap and covering the same with the soil obtained from excavation of pit including all excavations and earthwork complete all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |
| 31 | M&L for cleaning the blockage of bathroom/kitchen by cleaning the nahni traps/gully traps of all the mud/sludge and getting out, washing thoroughly grating of tarp, CI waste pipes by opening the clearing eyes and depositing the sludge in a pit of suitable size at a distance not exceeding 50 meters from the gully trap and covering the same with the soil obtained from excavation of pit including all excavations and earthwork complete all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |