| 1 | Excavating to over area, n exc 1.5m deep and getting out by mechnical means complete all as specified and as directed. |
| 2 | All as per Item No 1 but depth exc 1.5 m complete all as specified and as directed. |
| 3 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and as directed. |
| 4 | Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 5 | Cement concrete M-10 (Nominal mix) using 40 mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and as directed. |
| 6 | Form work to sides of concrete fdn footing base of columns and raft beams sides and soffits (if any) of fdn and plinth beams and similar wk vertical or to batter for Fair finished surfaces complete all as specified and as directed. |
| 7 | Form work to sides of pillars, posts, struts, pier, columns square, rectangular or polygonal rough finished surface of concrete complete all as specified and as directed. |
| 8 | Form work to sides and soffits of floor or roof beams, beam haunching, lintel etc rough finished surfaces of concrete flats complete all as specified and as directed. |
| 9 | RCC M-25 design mix as in fdn, including raft, fooling fdn beams, plinth beams bases for columns and mass concrete complete all as specified and as directed. |
| 10 | RCC M-25 design mix as in beams, cantilivers, bressummers, lintel over 1.5m span complete all as specified and as directed. |
| 11 | RCC M-25 design mix as in columns , pillars, piers, posts and struts etc complete all as specified and as directed. |
| 12 | TMT bars (Fe 500),10 mm dia and over in reinforcement cut to length, bent to shape required including bending spirally cranking, hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 13 | TMT bars (Fe 500), 5mm dia and over upto incl 10mm dia stirrups bending spirally or hooping for columns, hooking ends and binding with mild steel wire not less than 0.90mm dia complete all as specified and as directed. |
| 14 | Brick work with flyash bricks having crushing strength not less than 75 Kg/Sqm, straight or curved on plan exceeding 6 m mean radius with old size bricks built in cement mortar 1 : 4 complete all as specified and as directed. |
| 15 | Rendering 15mm thick on fair faces brick surfaces in cement mortar 1 : 4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 16 | Applying two coats of cement based paint over concrete or newly plastered suraces incl preparing new plastered surfaces and applying priming coat etcall complete all as specified and as directed. |
| 17 | M&L for angle post/struct section fixed independently w/o connecting plate as in swan neck fencing of Fe-410-w(gde E-250A complete all as specified and as directed. |
| 18 | S&F Galvanised 2 strand steel barbed wire 2.24mm dia, barbed with 2.00 mm dia barbs at 75mm spacing, straining and fixing to any standard rails and straining bolts incl securing or typing at crossing with and provisions of galvanised mild steel wire stapples or steel pins etc complete all as specified and as directed. |
| 19 | M&L for Concetrina coil of 600 mm dia securing or tying incl provn of MS wire stapples or steel pins etcall complete all as specified and as directed. |
| 20 | M&L painting with synthetic enamel paint two coats over a coat of red oxide primer including preparing the new untreated steel surfaces of any description over 10cm in width or girthall complete all as specified and as directed. |
| 21 | Demolition of Brickwork or stone/Boulder masonary, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete artilces complete all as specified and as directed. |
| 22 | Dismantling of mild steel work/ barbed wire of any description not otherwise provided for complete all as specified and as directed. |
| 23 | M&L Boulder filling Dry, handpacked tightly, as in wire crate apron bunds ( wirecrete measured separately) complete all as specified and as directed. |
| 24 | S&F 4mm dia glavansied steel wire 150*100MM mesh, made up into mattresses or cages, lapped, wired and laid in positions, including closing after filling in complete all as specified and as directed. |
| 25 | M&L framed work suh as grills, gratings,etc with ends of bars shouldered and or reveted or forged into spikes, framed guard bars barred iron doors and similar work conforming to fe 290 gde -E-165 complete all as specified and as directed. Please Enable Macros to View BoQ information |