| 1 | Labour only for carrying out 'B' check Maintenance of DG/Fire Pump set of 320 KVA capacity after 200-250 Hrs running from last engine oil changed or earlier for the following DG sets of Make:- Kirloskar/Ashok Leylend/Cummins/Greaves complete all as specified and directed. Note:- (i) Maintenance of DG set to be carried out as per manufacturers instructions and by qualified service engineer of DG set service center. (ii) Materials/Spare parts/Lub oil required for above 'B' check maintenance shall be measured and paid seperately as \\"Supply only\\". |
| 2 | All as per BOQ Serial Item No. 1 above but capacity 62.5 KVA DG Set complete all as specified and directed |
| 3 | All as per BOQ Serial Item No. 1 above but capacity 200 KVA DG Set complete all as specified and directed |
| 4 | All as per BOQ Serial Item No.1 above but capacity 125 KVA DG Set complete all as specified and directed |
| 5 | All as per BOQ Serial Item No.1 above but capacity 79 HP Fire pump complete all as specified and directed |
| 6 | All as per BOQ Serial Item No.1 above but capacity 110 HP Fire pump complete all as specified and directed |
| 7 | Supply only Fuel filter with 'O' ring for 320 KVA DG Set and by pass filter (Make: Kirloskar/Kirloskar Green/BOSCH/Greaves or equivalent as approved by GE) for carrying out 'B' check maintenance complete all as specified and directed |
| 8 | All as per BOQ Serial Item No. 7 above but capacity 63 KVA DG Set complete all as specified and directed |
| 9 | All as per BOQ Serial Item No.7 above but capacity 200 KVA DG Set complete all as specified and directed |
| 10 | All as per BOQ Serial Item No.7 above but capacity 125 KVA DG Set complete all as specified and directed |
| 11 | All as per BOQ Serial Item No.7 above but capacity 79 HP Fire pump complete all as specified and directed |
| 12 | All as per BOQ Serial Item No.7 above but capacity 110 HP Fire pump complete all as specified and directed |
| 13 | Supply only Lub Oil filter with 'O' ring for 320 kVA DG set and by pass filter (Make: Kirloskar/Kirloskar Green/BOSCH/Greaves or equivalent as approved by GE) for carrying out 'B' check maintenance complete all as specified and directed |
| 14 | All as per BOQ Serial item No. 13 above but capacity 63 KVA DG Set complete all as specified and directed |
| 15 | All as per BOQ Serial item No.13 above but capacity 200 KVA DG Set complete all as specified and directed |
| 16 | All as per BOQ Serial item No.13 above but capacity 125 KVA DG Set complete all as specified and directed |
| 17 | All as per BOQ Serial item No.13 above but capacity 79 HP Fire pump complete all as specified and directed |
| 18 | All as per BOQ Serial item No.13 above but capacity 110 HP Fire pump complete all as specified and directed |
| 19 | Supply only Air filter for air cleaner of 320 KVA DG set (Make: Kirloskar/ Kirloskar Green/BOSCH/Greaves or equivalent as approved by GE) for carrying out 'B' check maintenance complete all as specified and directed |
| 20 | All as per BOQ Serial item No. 19 above but capacity 63 KVA DG Set complete all as specified and directed |
| 21 | All as per BOQ Serial item No. 19 above but capacity 200 KVA DG Set complete all as specified and directed |
| 22 | All as per BOQ Serial item No. 19 above but capacity 125 KVA DG Set complete all as specified and directed |
| 23 | All as per BOQ Serial item No. 19 above but capacity 79 HP Fire pump complete all as specified and directed |
| 24 | All as per BOQ Serial item No. 19 above but capacity 110 HP Fire pump complete all as specified and directed |
| 25 | S&F in replacement Fan Belt/dynamo Belt of suitable size (as per sample) for 63 to 320 KVA DG set (Make:Kirloskar/Fenner/Dunlop/Kirloskar green or equivalent as approved by GE) complete all as specified and directed. |
| 26 | S&F in replacement hose pipe for fuel line (as per existing) including adjustable hose clamps (Make: Kirloskar/Kirloskar Green/BOSCH/Greaves or equivalent as approved by GE) suitable for 63 to 320 KVA DG Sets complete all as specified and directed. |
| 27 | S&F in replacement shut down valve (as per sample) for the DG set of capacity 100/125/200 KVA/79 HP DG fire Pump complete all as specified and directed |
| 28 | M&L for cleaning of the fuel tank by vacating the tank, replacement of fuel level indicator and spray painting of tank by scraping the existing paint using 2 coats of synthetic enamel paint matching the existing colour complete all as specified and directed |
| 29 | M&L for maintenance and servicing of alternator by removing of dust and moisture from field coil and armature coil by blowing the hot air for the various capacity of DG set capacity 63 to 320KVA DG/ 79/110 HP Fire Pump complete all as specified and directed |
| 30 | S&F in replacement 180AH,12 Volt lead acid battery (Make: Exide/Amron or equivelent as approved by GE) complete all as specified and directed |
| 31 | S&F in replacement copper lead for battery of 1.5 mtr long cable of two nos of red and black clour having cable size size 25 sqmm complete all as specified and directed |
| 32 | Supply & filling distilled water for Batttery/Radiator complete all as specified and directed |
| 33 | Supply only rubber hose in repairs of radiator asssembly of DG set complete all as specified and as directed |
| 34 | M&L for removing the radiator assembly of DG Set capacity upto 63/79/110 HP from its base, taking to workshop, opening into parts, carryout overhauling the complete system, sort out and replacement of the unserviceable items, cleaning the channels, fins including necessary gas welding works, reassembling and refitting on its base including transportation of the same from work shop to site complete all as specified and directed. Note: Spare parts will be measured and paid saperately. |
| 35 | All as per BOQ Serial item No. 34 above but capacity 125 KVA DG Set complete all as specified and directed |
| 36 | All as per BOQ Serial item No. 34 above but capacity 200 KVA DG Set complete all as specified and directed |
| 37 | All as per BOQ Serial item No. 34 above but capacity 320 KVA DG Set complete all as specified and directed |
| 38 | S&F in replacement battery charger of charging capacity of 10 Amp 12/24 volt dually fixed in AMF panel with provn of necessary connection complete all as specified and as directed. |
| 39 | Supply, install and commissionning of microprocessor based AMF controller unit of 63 to 320 KVA capacity DG set by removing the old unsv control Panel unit and testing complete all as specified and as directed.Note : The faulty controller to be replaced with same mode/make for smooth functioning. |
| 40 | All as per BOQ Serial item No. 39 above but capacity 125 KVA DG Set complete all as specified and directed |
| 41 | All as per BOQ Serial item No. 39 above but capacity 200 KVA DG Set complete all as specified and directed |
| 42 | All as per BOQ Serial item No. 39 above but capacity 320 KVA DG Set complete all as specified and directed |
| 43 | S&F Fleet cool HD heavy duty coolant concentrate ultimate protection for increase engine life for 200 KVA complete all as specified and directed |
| 44 | Supply only engine oil of grade 20w 40 brought at site in sealed containers complete all as specified and directed.Make :- Power oil/ castrol /servo or equivalent as approved by GE |
| 45 | M&L for repairs/Servicing of dynamo 12/24 Volts of the DG/fire pump set by opening into parts, cleaning to sort out the unserviceable parts, replace by new one, rewinding and varnishing of coil, reassembling and refixing to its base including transportation from work shop to the site complete all as specified and as directed. |
| 46 | M&L for Repair/Servicing of self starter assembly of 300KVA DG Set by opening in to parts, sort out the unserviceable items like carbon bush, pinion, etc and replace the same with new one including rewinding of field coils, re-assembling and refixing the same in its original position including testing complete all as specified and directed |
| 47 | All as per BOQ Serial item No. 46 above but capacity 200 KVA DG Set complete all as specified and directed |
| 48 | All as per BOQ Serial item No. 46 above but capacity 125 KVA DG Set complete all as specified and directed |
| 49 | All as per BOQ Serial item No. 46 above but capacity 79 KVA DG Fire pump complete all as specified and directed |
| 50 | All as per BOQ Serial item No. 46 above but capacity 110 KVA DG Fire pump complete all as specified and directed |
| 51 | M&L for Repair/Servicing to AMF Panel 63 KVA Capacity DG Set by dismantling unserviceable items replacing the same by new one, rewiring all internal wiring and replacing relay circuit complete all as specified and directed |
| 52 | All as per BOQ Serial item No. 51 above but capacity 125 KVA DG Set complete all as specified and directed |
| 53 | All as per BOQ Serial item No. 51 above but capacity 200 KVA DG Set complete all as specified and directed |
| 54 | All as per BOQ Serial item No. 51 above but capacity 320 KVA DG Set complete all as specified and directed |
| 55 | S&F in replacement Start-stop-reset push button with LED lamp including all necessary incoming and outgoing electric connections after complete all as specified and as directed. Make : L&T/Legrand / ABB/C&S or equivalent as approved by GE |
| 56 | S&F in replacement Voltmeter, single phase, class - 1, digital type complete all as specified and as directed. Make : Make : L&T/Legrand / ABB/C&S or equivalent as approved by GE |
| 57 | S&F in replacement Ammeter, single phase, class - 1, 5A digital type complete all as specified and as directed. Make : L&T/Legrand / ABB/C&S or equivalent as approved by GE |
| 58 | S&F in replacement Amp meter selector switch after complete all as specified and as directed.Make : AE/KAPPA/KEYCEE or equivalent as approved by GE |
| 59 | S&F in replacement Volt meter selector switch after complete all as specified and as directed. Make : AE/KAPPA/KEYCEE or equivalent as approved by GE |
| 60 | S&F in replacement Current Transformer 5/160 complete all as specified and as directed. Make : Kappa/AE or equivalent as approved by GE |
| 61 | S&F in replacement Current Transformer 5/100 complete all as specified and as directed. Make : Kappa/AE or equivalent as approved by GE |
| 62 | Taking down 30HP centrifugal pump from existing position, dismantling the same to carry out repair works including replacement of required spare parts, reassembling, reinstalling, checking for alignment with motor and connecting complete all as specified and directed for following capacity of pump.Note: Spare parts required for renewal shall be measured and paid separately. |
| 63 | All as per BOQ Serial item No. 62 above but capacity 20HP complete all as specified and directed |
| 64 | All as per BOQ Serial item No. 62 above but capacity 10HP complete all as specified and directed |
| 65 | Supply only the following spare parts for pump set including motor for 25 HP centrifugal pump complete all as specified and directed:- |
| 66 | Impeller CI |
| 67 | Pump shaft |
| 68 | Stage bushing |
| 69 | Coupling |
| 70 | Bearings |
| 71 | Supply only the following spare parts for pump set including motor complete for 30 HP centrifugal pump complete all as specified and directed:- |
| 72 | Impeller CI |
| 73 | Pump shaft |
| 74 | Stage bushing |
| 75 | Coupling |
| 76 | Bearings |
| 77 | Dismantling and opening the 30 HP motor from pump set in existing position& M&L for carrying out re-winding work with new super enamelled copper wire of suitable gauge (as per existing) and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same with pump in original position complete all as specified and directed |
| 78 | Dismantling and opening the 25 HP motor from pump set in existing position for carrying out re-winding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same with pump in original position complete all as specified and directed |
| 79 | M&L for lifting/ lowering of U/S submersible pump set 25HP from tube wall after disconnecting the electric supply and taking out all coloumn pipes flanged/ socket type of any length keeping serviceable fittings in safe custody for reuse, removing U/S materials from site, and carrying submersible pump set to nearest repairing workshop including bring back after necessary repairs and lowering the same including all necesary fixtures like rubber gasket/nuts/bolts/washers of suitable size or welding materials for jointing cloumn pipes flanged/ socket type and connection of electric supply to motor, testing/commissioning, etc. complete all as specified and directed. Note. : Replacement of Column pipes shall be measured and paid seperately. |
| 80 | All as per BOQ Serial item No. 69 above but capacity 20 HP complete all as specified and directed |
| 81 | All as per BOQ Serial item No. 69 above but capacity 15 HP complete all as specified and directed |
| 82 | All as per BOQ Serial item No. 69 above but capacity 10 HP complete all as specified and directed |
| 83 | All as per BOQ Serial item No. 69 above but capacity 7.5 HP complete all as specified and directed |
| 84 | M&L for repair to motor of submersible pump 25 HP and taking out burnt windings, cleaning, rewinding with superior quality super enamelled copper wire of existing gauge, overhauling, refixing and testing complete all as specified and directed for following capacity of pump. |
| 85 | All as per BOQ Serial item No. 74 above but capacity 20 HP complete all as specified and directed |
| 86 | All as per BOQ Serial item No. 74 above but capacity 15 HP complete all as specified and directed |
| 87 | All as BOQ Serial per item No. 74 above but capacity 10 HP complete all as specified and directed |
| 88 | All as per BOQ Serial item No. 74 above but capacity 7.5 HP complete all as specified and directed |
| 89 | M&L for overhauling of submersible pump of 6 to 8 stage, 20HP installed at pump house with cleaning, stage casing, carbon trust bearing with pressure plate, Suction strainer, diffuser bronze, Impellers,Thrust bearing housing, Bearing segment carrier (CI), Diaphragm (rubber), Stud nut and bolt 8.0 mm dia and length as per requried, greasing, repairs to pump including replacement of spares parts like clamps, Impeller bushing, dischrage/ suction casing, gaskets etc & connected accessories complete all as specified and directed |
| 90 | M&L for overhauling of submersible pump of 6 to 8 stage 25HP installed at pump house with cleaning, Stage casing, Carbon trust bearing with pessure plate, Suction strainer, Diffuser Bronze, Impellers, Thrust bearing housing, rBearing segment carrier (CI), Diaphragm (rubber), Stud nut and bolt 8.0 mm dia and length as per requried, Greasing, repairs to pump including replacement of spares parts like clamps, Impeller bushing, Dischrage/suction casing, Gaskets etc & connected accessories complete all as specified and directed |
| 91 | M&L for overhauling of submersible pump of 6 to 8 stage, 15HP installed at pump house with cleaning, Stage casing, Carbon trust bearing with pressure plate, Suction strainer, Diffuser Bronze, Impellers,Thrust bearing housing, Bearing segment carrier ( C.I ), Diaphragm (rubber), Stud nut and bolt 8.0 mm dia and length as per requried, Greasing,repairs to pump including replacement of spares parts like clamps, Impeller bushing, Dischrage/suction casing, Gaskets etc & connected accessories complete all as specified and directed |
| 92 | M&L for overhauling of submersible pump of 6 to 8 stage, 10HP installed at pump house with cleaning, Stage casing, Carbon trust bearing with pressure plate, Suction strainer, Diffuser Bronze, Impellers,Thrust bearing housing, Bearing segment carrier (CI), Diaphragm (rubber), Stud nut and bolt 8.0 mm dia and length as per requried, Greasing, repairs to pump including replacement of spares parts like clamps, Impeller bushing, Dischrage/ suction casing, Gaskets etc & connected accessories complete all as specified and directed. |
| 93 | M&L for painting of 7.5 HP capacity submersible pump set after removing old painted/rusted surface by paint removers such as blow lamps, scrapers etc over the surface of motor and pump body and outer surface of column pipes, 18.45 M long and painting with two coat of anti- corrosive synthetic paint over two coat of red oxide primer and shall be painted with electrical spray machine and writing MES NO & CAPACITY using white paint on painted surface on directed location complete all as specified and directed |
| 94 | All as per BOQ Serial item No.83 above but capacity 10 HP complete all as specified and directed |
| 95 | All as per BOQ Serial item No. 83 above but capacity 15 HP complete all as specified and directed |
| 96 | All as per BOQ Serial item No. 83 above but capacity 20 HP complete all as specified and directed |
| 97 | All as per BOQ Serial item No. 83 above but capacity 25 HP complete all as specified and directed |
| 98 | S&F in replacement water proof submersible flexible flat copper cable, 10 Sqmm 3 core, 1100 Volts complete all as specified and directed. Note : Rate quoted shall be deemed to be inclusive of the cost of under water fixing arrangements complete. |
| 99 | S&F in replacement PVC insulated Copper Cable of Size 16 Sqmm single core, 1100 Volt complete all as specified and directed. |
| 100 | S&F in replacement PVC insulated Copper Cable of Size 10 Sqmm single core , 1100 Volt complete all as specified and directed |
| 101 | S&F in replacement PVC Insulated FRLSH flexible Copper wire 1100 Volt grade conforming to IS: 694/2010 of size 50 Sqmm single core complete all as specified and directed |
| 102 | S&F in replacement Fully Automatic star-delta starter MN32 FASD of relay range 20-30 Amps, in Sheet-Steel Enclosure suitable for upto 30 HP pump complete all as specified and directed. Make : L&T (Cat No SS94364)/BCH/TC/SIEMENS or equivalent as approved by GE |
| 103 | S&F in replacement Fully Automatic star-delta starter ML3 FASD of relay range 28-42 Amps, in Sheet-Steel Enclosure suitable for upto 30 HP pump complete all as specified and directed. Make : L&T (Cat No SS90730)/BCH/TC/SIEMENS or equivalent as approved by GE |
| 104 | S&F in replacement DOL starters 3 phase 415 volts 7.5 HP 9-14 range complete all as specified and as directed. |
| 105 | S&F in replacement Three pole power contactor 63 Amps complete all as specified and directed. |
| 106 | S&F in replacement Three pole power contactor 100 Amps complete all as specified and directed. |
| 107 | S&F in replacement Three pole power contactor MCE15 MO series A-1 having AC3, 95A, 47KW rating complete all as specified and directed. |
| 108 | S&F in replacement Three pole power contactor ML12 current rating 300A, 3 phase complete all as specified and directed. Make : L&T (Cat No ML12SS91010) / Havells/ Legrand / ABB or equivalent as approved by GE |
| 109 | S&F in replacement four pole power contactor MCX 45 with aux contacts 2 No + 2 NC complete all as specified and directed. Make : L&T (Cat No CS97027) / Havells/Legrand / ABB or equivalent as approved by GE |
| 110 | S&F in replacement four pole power contactor MCX 46 with aux contacts 2 No + 2 NC complete all as specified and directed. Make : L&T (Cat No CS97028)/ Havells/Legrand / ABB or equivalent as approved by GE |
| 111 | S&F in replacement On load change over switch 400 Amps 415 Volt 4 pole complete all as specified and as directed. |
| 112 | S&F in replacement On load change over switch 320 Amps 415 Volt 4 pole complete all as specified and directed. |
| 113 | S&F in replacement On load change over switch 250 Amps 415 Volt 4 pole complete all as specified and as directed. |
| 114 | Supply and laying in repairs for under ground heavy duty XLPE insulated, armoured heavy duty aluminium conductor cable 1100 volts grade, cross-sectional area 240 sqmm 3.5 Core core in trenches / through pipe in road crossing / plinth/ drain/ duct/ floor along pole / wall /ceillings etc complete all as specified and directed.Note:- Earth work, bricks protection, sand cushioning shall be measured and paid seperately. |
| 115 | All as per BOQ Serial Item no 104 above but 400 sqmm 3.5 core complete all as specified and directed |
| 116 | All as per BOQ Serial Item no 104 above but 300 sqmm 3.5 core complete all as specified and directed |
| 117 | All as per BOQ Serial Item no 104 above but 120 sqmm 3.5 core complete all as specified and directed |
| 118 | All as per BOQ Serial Item no 104 above but 150 sqmm 3.5 core complete all as specified and directed |
| 119 | All as per BOQ Serial Item no 104 here in before but 95 sqmm 3.5 core complete all as specified and directed |
| 120 | S&F in replacement perforated GI Cable tray of size 450 mm (1.2mm thick)x 75 mm depth with cover to be fixed on wall or hanging with mounting bracket or hanging from ceiling with down rod etc, complete all as specified and directed |
| 121 | S&F in replacement perforated GI Cable tray of size 300 mm (1.2mm thick)x 75 mm depth with cover to be fixed on wall or hanging with mounting bracket or hanging from ceiling with down rod etc, complete all as specified and directed |
| 122 | S&F in replacement perforated GI Cable tray of size 200 mm (1.2mm thick)x 50 mm depth with cover to be fixed on wall or hanging with mounting bracket or hanging from ceiling with down rod etc, complete all as specified and directed |
| 123 | S&F in replacement perforated GI Cable tray of size 100 mm (1.2mm thick)x 50 mm depth with cover to be fixed on wall or hanging with mounting bracket or hanging from ceiling with down rod etc, complete all as specified and directed |
| 124 | M&L for Maintenance / servicing of APFC panel of capacity upto 700 KVA, 415 V, 50/60 Hz, 50kA for auto correction of power factor, checking of each capacitor bank, connector and MCB, Cleaning and servicing of all fixed and moving contacts replacement of accessories i.e lockable trip push button,auto /manual switch, indicator, volt meter, ammeter, etc after disconneting the APFC for execution of work and re-fixing the same after replacement of old serviceable spare parts in existing position and reconnecting all cables and testing on existing load complete with & including applying one coat of primer and two coat of synthetic enamel paint after removal of old paint complete all as specified and directed. Note:- All new spare parts as required shall be measured and paid seperately. |
| 125 | S&F in replacement capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity complete all as specified and directed Make : L&T/Neptune/C&S or equivalent as approved by GE |
| 126 | S&F in replacement capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 10 KVAR capacity complete all as specified and directed. Make : L&T/Neptune/C&S or equivalent as approved by GE |
| 127 | S&F in replacement capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 20 KVAR capacity complete all as specified and directed. Make : L&T/Neptune/C&S or equivalent as approved by GE |
| 128 | S&F in replacement capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 25 KVAR capacity complete all as specified and directed Make : L&T/Neptune/C&S or equivalent as approved by GE |
| 129 | S&F in replacement capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 50 KVAR capacity complete all as specified and directed. Make : L&T/Neptune/C&S or equivalent as approved by GE |
| 130 | S&F in replacement MOC 25 contactor complete all as specified and directed.Make :- L&T/C&S/Havells or equivalent as approved by GE |
| 131 | S&F in replacement LED indication lamps complete all as specified and directed. |
| 132 | S&F in replacement MCB 40- 63 Amp three pole 10 KA 'C' Series complete all as specified and directed. |
| 133 | M&L for Maint/servicing of APFC 100 KVAr Panel board with the folowing complete all as specified and as directed:-Main Incomer details(a) MCCB 400Amp 4 Pole , 36 KA, Model DN3-400D- 01 No (Make -L&T/Havells / Equivalent)(b) DN3 extended rotary handle - 01(c) Spreader Terminal DN-3 type, 4 pole-01 Set(d) Phase indicator lamp (RYB) - 03 Nos(e) Digital volt meter with selector switch 0-500 Volt - 01 No Make - L&T / AE /ESSMA (j) Digital Amp meter with selector switch 0-400A - 01 No Make - L&T / AE /ESSMA (k) CT 400/ 05 Amp - 04 Nos (Kappa/AE)(l) MCB SP 10A-03 Nos(n) MCB SPN 32A-01 NoPF Capacitor details(a) 5 KVAr heavy duty capacitor 440V AC, 3 PH- 01 No (Make - EPCOS/L&T )(b) 10 KVAr heavy duty capacitor 440V AC, 3 PH- 02 No (Make - EPCOS/L&T )(c) 25 KVAr heavy duty capacitor 440V AC, 3 PH- 05 No (Make - EPCOS/L&T )Branch Capacitor switch details(a) Duty contactor (1NO+01NC) for 05 KVAr capacitor (LCD1MK-II)- 01 No (Make - EPCOS/L&T )(b) Duty contactor (1NO+01NC) for 10 KVAr capacitor (LCD1MK-II)- 02 No (Make - EPCOS/L&T )(c) Duty contactor (1NO+01NC) for 25 KVAr capacitor(LCD1MK-II)- 05 No (Make - EPCOS/L&T ) |
| 134 | Branch Protection switch details(a) 10A, TP MCB for 05 KVAr - 01 No (L&T/Havells)(b) 32A, TP MCB for 10 KVAr - 01 No (L&T/Havells)(c) 63, TAP MCB for 25 KVAr - 01 No (L&T/Havells)Provision of Auto /Manual operations details(a) Green push button with NO element -09 Nos (L&T)(b) Red push button with NC element -09 NO (L&T)(c) 3 Pole auto-off manual selector switch - 01 Nos (Make - KAYCEE)(d) BR5000-16 stage APFC controler relay -01 Nos (Make - EPCOS)(e) Auxiliary relay (4NO+4NC)-09 NosLocation : PUMP HOUSE of IMH Complex |
| 135 | M&L for Maintenance / servicing of LT ACB upto1000A Capaxirty, 415 V, 50/60 Hz, Icu-50 kA Ics-50 kA, Icw-50kA for 1 second of make L & T with Cleaning and servicing of all fixed and moving contacts replacement of accessories i.e lockable trip push button, LIP, LAP, racking, interlock, door interlock, shunt release, under voltage release(UVR) etc after disconneting the ACB for execution of work and re-fixing the same shall be with old serviceable spare parts in existing position and re-connecting all cables and testing on existing load complete all as specified and directed. |
| 136 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 137 | Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. |
| 138 | Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 139 | M&L for Cutting of bitumenous road including top layer, WBM, sil/concreate surface for laying of cable protection pipe , water pipe etc and making food of disturbed surface with PCC 1:2:4 to match with the surroundings complete all as specified and directed. |
| 140 | M&L for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and directed. NOTE: Punned thickness shall be measured for payemnt purpose only. |
| 141 | Supply and laying for burnt brick sub class 'B' locally available best quality laid in trenches for protections of under ground cable complete all as specified and as directed. |
| 142 | M&L for plain cement concreate (1:4:8) type D2 (using 40 mm graded stone aggregrate) as in foundations filling, coping for pole and mass concreate complete all as specified and as directed. |
| 143 | M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 144 | M&L for plain cement concreate (1:3:6) type C2 (using 40 mm graded stone aggregrate) as in foundations filling, coping for pole and mass concreate complete all as specified and directed. |
| 145 | Excavating in post holes (or similar holes) each n exc 0.5cum, in any type of soils,, getting out, returning,filling in and ramming earthor broken rubblemixed with earth around in layers not exceeding 25 cm complete all as specified and directed |
| 146 | S&F in replacement MS Fabrication work consisting of wire mesh, MS Angle squire pipe, Flate etc duly cut into shape and size to fabricate the shape including grouting on wall, floorcetc and one coat of red oxide metal primar and two coats of synthetic enamel paint complete all as specified and directed. |
| 147 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 148 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 149 | M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed. |
| 150 | M&L for Steel work in 100 mm tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes complete all as specified and directed. |
| 151 | M&L for Framed work as in doors or gates of angle or other sectionwith gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting or othercovering. Doors, etc. to beprepared for hanging or slidingwithandincluding either hooks and hinges or steel hangingdoor fittings (exclusive of steels heeting or other covering, running rails and guides) and hanging; also fastening complete all as specified and directed |
| 152 | M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed |
| 153 | M&L for welded steel wire fabric to be fixed on steel structure complete all as specified and directed. |
| 154 | M&L for Mild steel bars 6mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, bendin spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 155 | S&F in replacement LED street light with IP 66protection and front toughen glass luminaries of capacity 45 watt with high power LED and ensure uniform light distribution complete all as specified and as directed. |
| 156 | S&F in replacement LED security light with IP 66 protection and front toughen glass luminaries of capacity 70 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 157 | S&F in replacement LED street light with IP 66 protection and front toughen glass luminaries of capacity 120 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 158 | S&F in replacement LED flood light of IP protection 66 with front toughen glass luminaries of capacity 120-150 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 159 | S&F in replacement LED flood light of IP protection 66 with front toughen glass luminaries of capacity 100 watt with high power LED and ensure uniform light distribution complete all as specified and directed. |
| 160 | S&F in replacement 20 watt LED post top lantrerns fittings made in cast aluminium spigot, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessory electric connection with from junction box to post top lantern complete all as specified and as directed. |
| 161 | S&F in replacement 40 watt LED post top lantrerns fittings made in cast aluminium spigot, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessory electric connection with from junction box to post top lantern complete all as specified and as directed. |
| 162 | S&F in replacement 10 watt LED bollard light 6000K, 2 feet long, 230V complete all as specified and directed |
| 163 | S&F in replacement single aluminium strip of size 25x3.15 mm in proper position with saddles and fixing screws for roof conductors and down conductors from top of the building air termination point to the test point of the building of height G+1 to G+12 as required complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 164 | S&F in replacement single aluminium strip of size 25x3.15 mm in proper position with saddles and fixing screws for roof conductors and down conductors from top of the building air termination point to the test point of the building of height G+1 to G+12 as required complete all as specified and as directed. Please Enable Macros to View BoQ information |