Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKS FOR BUILDING RENOVATION |
| 2 | Supply & Finishing/painting of External walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm applied @ 2.20 kg/10 sqm) DSR-23/13.45.1 |
| 3 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10sqm DSR-23/13.48.1 |
| 4 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etcDSR-23/13.88 |
| 5 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.DSR-23/13.80 |
| 6 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufactureDSR-23/13.48.3 |
| 7 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.DSR-23/15.56 |
| 8 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-chargeIn cement mortarDSR-23/15.7.4 |
| 9 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Single leafDSR-23/9.21.1 |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand)DSR-23/6.1.2 |
| 11 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand)DSR-23/13.2.1 |
| 12 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangementand making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock andDSR-23/21.18 |
| 13 | Filling the gap in between glass/aluminium/ stone/ wood frame and adjacentRCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/ structural non sag elastomeric PU sealant over backer rod of approvedquality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600-Upto 20 mm depth and 20 mm widthDSR-23/21.19.3 |
| 14 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .Cost of aluminium snap beading shall be paid in basic item With float glass panes of 8 mm thickness (weight not less 20 KG/SQM)With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)DSR-23/21.3.3 |
| 15 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/ soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately)18 mm thickDSR-23/26.89 |
| 16 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete with all respect for cricket pitch size of pitch shall be 20.12mtrx3.5mtrHot finished welded type tubesDSR-23/10.16.1 |
| 17 | Providing and fixing G.I. (4mm dia ) chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 4-5 mm dia wire or nuts, bolts and washers as required complete with all respect for Cricket pitch. All works shall be done as per the direction of Engineer-in-chargeMade of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in requiredcolour and shadeDSR-23/16.70.2 |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. DSR-23/4.1.8 |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING]DSR-23/1.41.2 |
| 20 | Providing reinforced by organic fibres and/or inorganic synthetic/cement sheet fibrescement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drillingfastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and DSR-23/12.8 |
| 21 | Carpentor/semi skilled labour for Dismantling old corrogated sheet and cleaning the surface including disposal up to 50 mtr only .DSR-23/12.10/011 |
| 22 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system inthe scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as perdirections and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for executionDSR-23/24.2 |
| 23 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involvedDSR-23/15.60 |
| 24 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area clearedDSR-23/2.31 |
| 25 | Providing & fixing fly proof wire gauze to windows, clerestory windows &doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides.DSR-23/10.29.1 |
| 26 | NEW STRUCTURE FOR KHO-KHO & ZUDO KARRATE |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kind of soilDSR-23/2.8.1 |
| 28 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors.DSR-23/4.1.8 |
| 29 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.DSR-23/2.27 |
| 30 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR LINTEL] M-20.As in item above but in R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete)DSR-23/5.3 |
| 31 | As in item above for the lighter beams & column i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)DSR-23/5.3A |
| 32 | Centering and shuttering with 12 mm thick shuttering plywood confirming to IS 4990:2011 and removal of form at all heights. Plywood will be supported on lock barsDSR-23/26.64.1 |
| 33 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.DSR-23/5.22.6 |
| 34 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent only for columnDSR-23/11.56.1 |
| 35 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubesDSR-23/10.16.1 |
| 36 | Providing, Fabricating & laying of colour coated Galvalume (Proflex system roofing) material for self supported roofing system (Technology similar to Proflex system , Material shall be of following specification, BMT 1.60mm to 1.80mm, APT 0.95mm Tolerance +/- 0.02mm thick, width 605 mm or as dicided by E/Incharge (Tolerance +/-2mm), including supplying, loading, transporting, unloading and staking at site, fabricating and laying with all contractors tools, plants, machineries materials and fixtures labours including all lead and lift and laps/ wastage if any etc. complete. The colour of sheet will be decided by E/I. The rate is also inclusive of designing of roofing system, proof checking and providing execution drawing. Fabrication and installation of self supported roofing technology similar to Profles System size of structure length 40meterX width 30 Mtr as per site requirement. Arch length meter or as per site requirement. Note: The roofing system should be self sunbartad .Roofing should be designed as per ASCE 7-20 international building code 2002. The analysis shall be carried out for span and center arch-rise considering the required live load, wind load, dead load, and the seismic factor. The roof panel formation shall be done as per the required length and curvature using hydraulic profile machine to give it the trapezoidal shaped using a spreader bar and sling evenly placed to ensure no distortion of the panel during lifting and placing. The crane shall hold/support the panel till the alignment is done and completed using a plumb and water tube and bolted into beam. These curved panels have interlocking formation and are crimped together using mechanical seaming machine, which imposes a load of approximately five tones to insure the seaming of required rigidity.After. seaming a clear epoxy lacquer is applied on the inner sideof panel end in 15cm width to form a protective layer between panel and concrete beam. These panels are installed over existing water proof concrete gutter-beams having beveled edge to recieve (support) curved panels.Beams shall design for arch reaction and vertical loads. Plaster shall not be applied on the beam.Schmidt hammer test of the concrete should be carried out before erection to ensure that the anchor bolt can be securely fixed on support.In case of steel structure a steel runner plate of 6mm thickness and G.I sheet gutter of suitable size shall be provided for installation of panels, G.I anchor bolt of required sizes and type with G.I washer and neoprene washer shall be provided as per design. After installation of panels, trapezoidal voids are created between gutter-beam and panels which should be covered by a flashing fabricated or brick masonary which is to be paid seperately. Area of this roof shall be measured along the peripheri of hem-top between end to end of panels. Ridge and valley shall not be taken into consideration for measuring length tranverse to peripheri. The rate includes supplying ,fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolts, epoxy, paint and all wastage etc.complete, The rate includes supplying and fixing accessories and fixtures like hangers/clamps for installation of lighting/fixtures/utility/duct as per requirement. This item shall be executed only by the agency, which has all required manufacturing machineries and neccesary expertiseMR |
| 37 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filledwith white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever . Wall thickness-1mm/275gm/sqm only for Wall paneling DSR-23/12.1.1 |
| 38 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture the primer qty included.DSR-23/13.48.3 |
| 39 | NEW STRUCTURE FOR SWIMMING POOL |
| 40 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kind of soilDSR-23/2.8.1 |
| 41 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors.DSR-23/4.1.8 |
| 42 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.DSR-23/2.27 |
| 43 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR LINTEL] M-20.As in item above but in R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete)DSR-23/5.3 |
| 44 | As in item above for the lighter beams & column i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)DSR-23/5.3A |
| 45 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.DSR-23/5.22.6 |
| 46 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent only for columnDSR-23/11.56.1 |
| 47 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubesDSR-23/10.16.1 |
| 48 | Providing and fixing of self supported arch shaped mechanically seamed trussless galvalume roofing system such as Proflex or similar as approved by Engineer in-charge, made of superior quality structural grade steel, having 350 MPA yield strength, precoated galvalume sheet as per ASTM A 792 M of base thickness 1.0mm (tolerance +/-.02mm) with minimum coating mass as per AZM 150. Total coated thickness 1.075mm (tolerance +/-.02mm). Roofing should be designed as per ASCE 7-20 international building code 2002. The analysis shall be carried out for span and center arch-rise considering the required live load, wind load, dead load, and the seismic factor. The roof panel formation shall be done as per the required length and curvature using hydraulic profile machine to give it the trapezoidal shape in required curvature. In this process the width of the sheet reduced from 914 metre to 0.61 meter using a suitable crane and using a spreader bar and sling evenly placed to ensure no distortion of the panel during lifting and placing. The crane shall hold/support the panel till the alignment is done and completed using a plumb and water tube and bolted into beam. These curved panels have interlocking formation and are crimped together using mechanical seaming machine, which imposes a load of approximately five tones to insure the seaming of required rigidity.After. seaming a clear epoxy lacquer is applied on the inner sideof panel end in 15cm width to form a protective layer between panel and concrete beam. These panels are installed over existing water proof concrete gutter-beams having beveled edge to recieve (support) curved panels.Beams shall design for arch reaction and vertical loads. Plaster shall not be applied on the beam.Schmidt hammer test of the concrete should be carried out before erection to ensure that the anchor bolt can be securely fixed on support.In case of steel structure a steel runner plate of 6mm thickness and G.I sheet gutter of suitable size shall be provided for installation of panels, G.I anchor bolt of required sizes and type with G.I washer and neoprene washer shall be provided as per design. After installation of panels, trapezoidal voids are created between gutter-beam and panels which should be covered by a flashing fabricated or brick masonary which is to be paid seperately. Area of this roof shall be measured along the peripheri of hem-top between end to end of panels. Ridge and valley shall not be taken into consideration for measuring length tranverse to peripheri. The rate includes supplying ,fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolts, epoxy, paint and all wastage etc.complete, The rate includes supplying and fixing accessories and fixtures like hangers/clamps for installation of lighting/fixtures/utility/duct as per requirement. This item shall be executed only by the agency, which has all required manufacturing machineries and neccesary expertise and G.I sheet gutter of suitable size shall be provided for installation of panels, G.I anchor bolt of required sizes and type with G.I washer and neoprene washer shall be provided as per design. After installation of panels, trapezoidal voids are created between gutter-beam and panels which should be covered by a flashing fabricated or brick masonary which is to be paid seperately. Area of this roof shall be measured along the peripheri of hem-top between end to end of panels. Ridge and valley shall not be taken into consideration for measuring length tranverse to peripheri. The rate includes supplying ,fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolts, epoxy, paint and all wastage etc.complete, The rate includes supplying and fixing accessories and fixtures like hangers/clamps for installation of lighting/fixtures/utility/duct as per requirement. This item shall be executed only by the agency, which has all required manufacturing machineries and neccesary expertiseMR |
| 49 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filledwith white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever . Wall thickness-1mm/275gm/sqm only for Wall paneling DSR-23/12.1 |
| 50 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufactureDSR-23/13.48.3 |
| 51 | DEVELOPMENT OF PATHWAY |
| 52 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Rate to include cost of all materials, labour and T & P etc. required for proper completion of the work.DSR-23/2.27 |
| 53 | P/L Paver Block 80 mm thick, Compressive strength >=M 50, Steel mould compressive technology.SR |
| 54 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5: Cement mortar 1:4 (1 cement : 4 coarse sand)DSR-23/6.4.1 |
| 55 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)DSR-23/4.1.8 |
| 56 | Supply ,fixing, testing & commissioning of 7 mtr decorative steel pole with bracket made out of round GI pipe section with lower portion of pole made of MS for covering of bolt.The pole lower portion {1.5 mtr (L)} outer diameter should be approx 140mm to 114 mm(wall thicknes-4mm) and upper portion{2.5mtr(L)} outer diameter should be approx 90mm to 60mm(wall thickness-3mm) at the top.Base plate is made of 10mm/12mm MS sheet base so designed that the foundation bolt are not visible .The pole are painted with multiple coat of weather resistant polyurethane paint the service window at the lower part of the pole contains connector,cutouts & MCB etc.The single arm bracket is made out of steel section of vairious diameters the bracket can be made as per top of pole diameter.the RCC foundation of pole also included with 450mm long x12mm dia foundation bolt .The bidder should be Submit the sample of pole for approval of paint and designe. The waranty of each part of equipment should be minimum 5years. Make-as per approved UP PWD MR |
| 57 | Supply, fixing ,testing & commissioning of IP 65 protection 60 watt post top latern as per approved and suitable for 7 mter decorative pole, the colour of lamp should be as per approval of Engineer/Incharge Make as per approved UP PWDMR |
| 58 | Supply and laying of 4X16 sq. mm 2 core aluminium conductor PVC Insulated armored served sheathed cables 1100 Volts grdes at a depth of 750 mm below ground level over a cushion of 75 mm, thick sand all round and protected with burnt bricks on sides and on top .On surface the cables run shall be fixed on MS.clamps etc. suitables size or as directed by the Engineer - in charge. complete in all respected as per SOR sch Or 2022 SI. No 501SOR |
| 59 | EXTERNAL LIGHTING PANEL-1Supply and Fixing Following capacity of automatic street light cubical control panel painted with anticorrosive alkali and acid proof paint consisting of time switch Tso 100 series with contactors, HRC fuses, isolating switch metering instrument & intrument box with CTs etc. in case of TPN, complete in all respect. SOR-2022 SI. No. 807 (f) (I) 40 A TPNINCOMER-Included aboveSOR |
| 60 | OUTGOINGSS&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve CAT-BProvide the space in panel for provision of CCMS System.And Energy MeterALL EQUIPMENTS AND ITEMS SHALL BE AS PER - U.P.PWD/CPWD APPROVED MAKESupply of EXTERNAL LIGHTING PANEL as described above.SOR |
| 61 | Supply and making the end termination with brass compression gland alluminium lugs for 4core 16 sqmm alluminium cable armured XLPE 1.1 grade cable.SOR |
| 62 | Supply and buring of safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length ,up to 3000 mm, outer pipe 76 mm Inner Dia 38 mm terminal Dia 12 mm terminal Dia 12 mm, outer GI pipe complete. SOR-2018 SI No 725DSOR |
| 63 | PLUMBING |
| 64 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot restsDSR-23/17.1 |
| 65 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lidDSR-23/17.3.1 |
| 66 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.DSR-23/17.7 |
| 67 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm diaDSR-23/17.28.1.1 |
| 68 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC_automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with, outlet grating and other couplings In C.P. brass, Including painting of fittings and cutting and making good the walls and floors wherever required:Single half stall urinal with 5 litre P.V.C. automatic flushing cisternDSR-23/17.5.1 |
| 69 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement:2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in- charge and finished smooth.Granite Stone of approved shadeDSR-23/8.10.2 |
| 70 | CP Brass fittingsProviding and fixing unplasticised PVC connection pipe with brass unions45 cm length15 mm nominal boreDSR-23/18.21.2.1 |
| 71 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931a) 15 mm nominal boreDSR-23/18.49.1 |
| 72 | Aangle volve 15 mmDSR-23/ |
| 73 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. ( for sink)a) 15 mm nominal boreDSR-23/18.51.1 |
| 74 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer- in-charge.DSR-23/17.22.A |
| 75 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.DSR-23/17.71 |
| 76 | Providing & fixing soil, waste and vent pipes.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905100mm dia centrifugally cast iron S & S pipe.DSR-23/17.35.1.3 |
| 77 | Providing & fixing soil, waste and vent pipes.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:1590575mm dia centrifugally cast iron S & S pipe.DSR-23/17.35.2.3 |
| 78 | Providing and fixing GI pipes complete with GI fittings and clamps, including cuttingand making good walls etc. ( for wash basin waste)32mm dia nominal boreDSR-23/43377 |
| 79 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & makinggood the walls etc for 100mm dia pipe.DSR-23/17.37.1 |
| 80 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & makinggood the walls etc for 75mm dia pipe.DSR-23/17.37.2 |
| 81 | Providing & fixing cast iron coller.100mm dia.DSR-23/17.57.1.1 |
| 82 | Providing & fixing cast iron coller.75mm dia.DSR-23/17.57.2.2 |
| 83 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100mm inlet & 100mm outlet.DSR-23/17.60.1.3 |
| 84 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100mm inlet & 75mm outlet.DSR-23/17.60.2.3 |
| 85 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100 mmDSR-23/17.38.1.3 |
| 86 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.75mmDSR-23/17.38.2.3 |
| 87 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)110 mm diaDSR-23/19.2.1 |
| 88 | Providing and fixing on wall face unplasticised- Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.110 mmDSR-23/12.41.2 |
| 89 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.CouplerBend 87.5 degree110 mm BendDSR-23/12.42.5.2 |
| 90 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipesDSR-23/43314 |
| 91 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.25mm dia nominal outer dia pipesDSR-23/43315 |
| 92 | Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal boreDSR-23/18.17.1 |
| 93 | Providing and fixing cp soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.DSR-23/18.65 |
| 94 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreDSR-23/18.18.3 |
| 95 | ELECTRICAL LIGHTS |
| 96 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group CDSR-22/1.10.3 |
| 97 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.DSR-22/1.11 |
| 98 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.DSR-22/1.12 |
| 99 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wireDSR-22/1.14.1 |
| 100 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireDSR-22/1.14.2 |
| 101 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wireDSR-22/1.14.5 |
| 102 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wireDSR-22/1.14.6 |
| 103 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mmDSR-22/1.21.2 |
| 104 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switchDSR-22/1.24.1 |
| 105 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outletDSR-22/1.24.4 |
| 106 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.DSR-22/1.25 |
| 107 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)DSR-22/1.27.1 |
| 108 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.DSR-22/1.31 |
| 109 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connections etc. as required.DSR-22/1.32 |
| 110 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweepDSR-22/1.50.1 |
| 111 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.DSR-22/1.51 |
| 112 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.DSR-22/1.57 |
| 113 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double doorDSR-22/2.4.3 |
| 114 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 A, 16 KA,TPMCCB for above dbDSR-22/2.2.2 |
| 115 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleDSR-22/2.10.1 |
| 116 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double poleDSR-22/2.10.3 |
| 117 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutralDSR-22/2.10.5 |
| 118 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.DSR-22/5.4 |
| 119 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.DSR-22/5.11 |
| 120 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.DSR-22/5.15 |
| 121 | Supply and fixing of recess/Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver pleasing aesthetic look. Complete in all respectSOR-22/1401 |
| 122 | Supply of 15W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. SOR-22/1402 |
| 123 | Supply and fixing of LED Street light Fitting having die castaluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 65 and above Protection complete in all respect.SOR-22/1424 |
| 124 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.DSR-23/19.1 |
| 125 | Supply and Installation of Heavy duty MS pipe, Size- 6 InchMR |
| 126 | Supply and Installation of Bend 90 Degree, MS, Size- 6 InchMR |
| 127 | Supply and Installation of Valve Butterfly, CI Body, Sheet- Rubber, Size- 6 InchMR |
| 128 | Supply and Installation of Softener FiltersMR |
| 129 | Supply and Service of Softner filter unit by replacing sandMR |
| 130 | Supply and Service of Softner Filter by replacing Filter Stone 1 InchMR |
| 131 | Supply and Installation of Panel Starter-55 KWMR |
| 132 | Supply and Installation of Panel Starter- 5.5 KWMR |
| 133 | Supply and Installation of Panel Starter- 5.5 KW |
| 134 | Supply and Connection wof Wire 3 phase x 4mmMR |
| 135 | Supply and Installation of Motor 3 Phase, 10 KwMR |
| 136 | Supply and Installation of Submersible Motor- Size 6 inch, 3-Phase, IP68, Insulation Class F or BMR |
| 137 | Fasterners & Gasket ChargesMR |
| 138 | Service and Testing ChargesMR |
| 139 | ELECTRICAL HIGH SIDE |
| 140 | Supply and fixing of 20 mtr High mast Pole of approved make with rising system, hot dip Galvanized inside & outside , having pole sheet thickness 4mm,top dia minimum150mm, bottom dia minimum 410mm, base plate 32mm thick, suitable for wind velocity as perIS 875 part 3 &.having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 10 luminaries & its control gear boxes,1.5 HP Power tool motor, 3 point suspension system with steel wire rope 8 mm dia , double drum winch. Including making suitable Foundation as per manufacture drawing & site requirement along with foundation bolts, nuts, washers , anchor plates etc Complete in all respect as per direction and satisfaction to the Engineerin |
| 141 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 150 Watt. Confirming to IP 65 and above Protection complete in al |
| 142 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitablesize or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the 4CORE X 6 SQMM AL.AR.XLPE Cable |
| 143 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in a |
| 144 | S&F of 0.5 Amp to 5 Amp. SP MCB (10KA) C Curve Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy