| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 5 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in: |
| 7 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 9 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 11 | Fixed to steel windows by welding |
| 12 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 13 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 14 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 15 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 16 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 17 | G.I. pipes |
| 18 | Providing and fixing M.S. steel window casement fastener with necessary screws or bolts etc. complete as per the direction of Engineer in charge. |
| 19 | 100 mm |
| 20 | Providing and fixing M.S. window casement stays (straight peg type) with necessary screws etc. complete as per the direction of Engineer in charge. |
| 21 | 300 mm weighing not less than 200 grams |
| 22 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. |
| 23 | 18 mm thick |
| 24 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 25 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 26 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 27 | 110 mm diameter |
| 28 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. The item excludes cost of scaffolding which shall beincluded in relevant item of scaffolding for maintenance work. |
| 29 | Coupler |
| 30 | 110 mm diameter |
| 31 | Bend 87.5° |
| 32 | 110 mm diameter |
| 33 | Shoe (Plain) |
| 34 | 110 mm diameter |
| 35 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 36 | Providing and fixing M.S. clamps made of 25x5 mm flat of approved design, size and shape to unplasticised - PVC rain water pipes fixed with M.S. justi khila of required length including applying steel primer and painting with Two coats of synthetic enemel paint of approved quality etc. complete as per the direction of Engineer incharge. |
| 37 | 110 mm diameter |
| 38 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 39 | 1:6 (1 cement : 6 coarse sand) |
| 40 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand ) and a top layer 6mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand ) finished rough with sponge. |
| 41 | 6mm cement plaster of mix: |
| 42 | 1:3 ( 1 cement : 3 fine sand ) |
| 43 | White washing with lime to give an even shade : |
| 44 | New work (three or more coats) |
| 45 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 46 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 47 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 48 | Two or more coats on new work |
| 49 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead. |
| 50 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 51 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 52 | Dismantling 15 to 40 mm dia G.I. pipe with fittings including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer in-Charge. |
| 53 | Internal Work- Exposed on wall |
| 54 | Fixing of loose door/window frame with shutters of any size, with or without taking out existing wooden door shutter, by fixing with M.S. screws or dash fasteners of required size, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 55 | Deduct for component of scaffolding in items of external plaster,dismantling of old plaster and repairable windows on external face and PVC pipe lines on external face. The deduction in respect of these items to be made due to the scaffolding will be paid separately in relevant item of scaffolding. |
| 56 | In respect of 18mm Cement plaster |
| 57 | In respect of Dismantling old cement plaster |
| 58 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 59 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 60 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 61 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 62 | In cement mortar |
| 63 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 64 | Of area 3 sq. metres and below |
| 65 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 66 | For thickness of tiles 5 mm to 25 mm |
| 67 | Dismantling C.I. or asbestos or PVC rain water pipe/drainage pipes with fittings and clamps including stacking the material within 50 metres lead : |
| 68 | 75 to 80 mm dia pipe |
| 69 | 100 mm dia pipe |
| 70 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 71 | 15 mm to 40 mm nominal bore |
| 72 | Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. |
| 73 | Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. |
| 74 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 75 | Disposal of building rubbish/ malba/ similar unserviceable dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. Please Enable Macros to View BoQ information |
| 76 | Disposal of building rubbish/ malba/ similar unserviceable dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. Please Enable Macros to View BoQ information |