| 1 | Supply and fix in repair condenser cooling fan motor with fan blade of cap 1/30 HP suitable for water cooler of cap 80/40 & 100 ltrs. |
| 2 | S&F in repair, float valve high pressure of PTMT body with epoxy coated Aluminium rod and high density plastic ball screwed for 15 mm bore iron pipe, weight not less than 140 grams/each, fixed to water cooler complete all as specified & directed by Engr-in -charge. |
| 3 | S&F in repair, 15 mm bore bib tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specified & directed by Engr-in -charge. |
| 4 | S&F in repair, starting capacitor 80-100 MFD suitable for water cooler of any capacity complete all as specified & directed by Engr-in -charge. |
| 5 | S&F in repair, running capacitor 40-60 MFD suitable for water cooler of any capacity complete all as specified & directed by Engr-in -charge. |
| 6 | S&F in repair, thermostat suitable for water cooler of any capacity complete all as specified & directed by Engr-in -charge. |
| 7 | S&F in repair, relay with over load protection suitable for 40 to 150 liters capacity water cooler complete all as specified & directed by Engr-in -charge. |
| 8 | Taking down old unsv GI Tubing of 15 mm from floors |
| 9 | M&L for 15 mm bore mild steel galvanized water tubing, medium grade with all fitting and accessories complete fixed to wall and celling or laid in floors complete all as specified & directed by Engr-in -charge. |
| 10 | Removing the unserviceable compressor sealed unit of any make from water cooler of capacity 40/80 liters after cutting copper tubing without any damage to exisiting parts, replacing compressor with new compressor of same make refixing of compressor on bace & jointing of copper refrigerant pipe line filter etc & charging gas to required level, including cleaning of fins, leakage testing etc including testing & commissioning for smooth functioning complete all as specified & directed by Engr-in -charge. |
| 11 | S&F in repair, condensing coil suitable for water cooler of capacity 40/80 liters complete all as specified & directed by Engr-in -charge. |
| 12 | M & L for flushing, pressurising the system , leakage testing vacuumisation and gas charging with suitable refrigerant gas at apprporiate pressure including testing at site for water cooler of cap 80/40 ltrs. |
| 13 | M&L for cutting and removing uncervicable freezer unit of refrigerator of capacity 165 to 270 liters of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified & directed by Engr-in -charge. |
| 14 | All as per Item No. 13 above but for freezer unit of refrigerator of capacity 280 to 310 Ltrs complete all as specified and directed by Engineer-in-Charge. |
| 15 | S&F in repair, thermostat suitable for refrigerator 165 to 310 liters capacity complete all as specified & directed by Engr-in -charge. |
| 16 | Removing the unserviceable compressor sealed unit of refrigerator of capacity 280 to 310 liters of any make, & replacing with new compressor of same make & model, rein-stalling in orignal position with all accessories like relay with over load protector, filter & recharging of refrigerant gas complete including testing & commissioning for smooth functioning complete all as specified & directed by Engr-in -charge. |
| 17 | All as per Item No. 16 above but for refrigerator of capacity 165 to 270 Ltr all as specified and directed by Engineer-in-Charge |
| 18 | M & L for flushing, pressurising the system, leakage testing vacuumisation and gas charging with required refrigerant gas at apprporiate pressure including testing at site for refrigerator of cap 165 to 270 ltrs complete all as specified and directed by Engineer-in-Charge. |
| 19 | All as per Item No. 18 above but for refrigerator of capacity 280 to 310 Ltrs all as specified and directed by Engineer-in-Charge. |
| 20 | S&F lamp with holder for refrigerator any capacity and any make incl removing old unsv lamp all as specified and directed by Engr In charge |
| 21 | Dismantling unserviceable compressor sealed unit of any make from deep freezer of cap 310 Ltrs after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube , filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge |
| 22 | M&L for removing the old burnt out condenser fan motor of Deep freezer of capacity 310 Ltrs from position and replacing with new motor and reassembling and fixing in position complete all as specified & directed by Engr-in -charge. |
| 23 | Dismantling unserviceable compressor sealed unit of any make from window type Air Conditioner of cap 1.5 TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube , filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge |
| 24 | All as item No. 23 above but 2.0 TR cap window type Air Conditioner complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and replace blower fan motor 1/8 HP suitable for window type Split type AC cap 1.5/2 ton complete all as specified and directed by Engineer-in-Charge |
| 26 | S&F running capacitor 45/50 MFD suitable for A/C of cap 1.5/2.0 TR complete incl removing unserviceable running capacitor all as specified & directed by Engr In Charge |
| 27 | S&F starting capacitor 60-120 MFD suitable for A/C of cap 1.5/2.0 TR complete incl removing unserviceable starting capacitor all as specified & directed by Engr In Charge |
| 28 | S&F Aluminium fan blade suitable for condensing side of window type AC 1.5/2.0 TR cap complete all as specified & directed by Engr In Charge |
| 29 | S&F PVC blower blade heavy duty suitable for evaporative side of window type Air conditioner 1.5/2.0 TR cap complete all as specified and directed by Engr in charge |
| 30 | S&F starting relay suitable for window type AC 1.5/2.0 TR cap complete all as specified and directed by Engr In Cahrge |
| 31 | S&F over load protector relay suitable for window type AC 1.5/2.0 TR cap complete all as specified and directed by Engr In Cahrge |
| 32 | S&F thermostat suitable for 1.5/2.0 TR cap window /Split type AC complete all as specified and directed by Engr In Charge |
| 33 | S&F air filter for split type AC 1.5 TR cap ( Set of three) complete all as specified & directed by Engr in Charge |
| 34 | Dismantling unserviceable compressor sealed unit of any make from external unit of Split type Air Conditioner of cap 1.5 TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube, filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge |
| 35 | All as per Item No. 34 above but for 2.0 Ton Split type AC complete all as specified and dierected by Engineer-in-Charge |
| 36 | S&F in repair PVC flexible drain out pipe 1.5 mtr length of Split type, heavy duty of 15/25mm dia and 1.5mm wall thickness complete with fittings, spacers and saddles etc complete all as specified & directed by Engr In Charge |
| 37 | S&F repair wireless remote control (Micro processor ) unit suitable for Split type AC any cap testing & complete all as specified and directed by Engr In Cahrge |
| 38 | M&L for 1/30 to 1/20 HP cooling side blower motor for split type AC with new washers nuts & bolts incl testing complete all as specified & directed by Engr In Charge |
| 39 | S&F PCB circuit of existing size & shape to split type AC having cap 1.5 / 2.0 TR complete all as specified & directed by Engr In Charge |
| 40 | M&L for servicing of split / window type AC of Cap 1.5TR / 2.0 TR of any make by opening the conderser unit fixed on roof top & cooling unit fixed inside the building, cleaning the complete conderser unit & cooling unit incl fins & checking / testing of all parts for its serviceablity & oiling / greasing of motors, replacing the worn out bushes of blowers & rectfication of unuseal noises, checking of refrigerent standing pressure, replacemnt of minor parts such as nuts bolts & washers etc & reassembling of complete unit incl testing & commissioning for smooth functioning complete all as specified & directed by engr in charge |
| 41 | M & L for flushing, pressurising the system, leakage testing vacuumisation and gas charging with refrigerant gas (R-22) at apprporiate pressure including testing at site for window / Split type AC cap 1.5 / 2.0 Ton. |
| 42 | S&F single pole and neutral enclosure with metal clad plug & socket 20 Amps & with MCB SP 20 Amps , 240 Volt complete all as specified and directed by Engr in Charge |
| 43 | M & L for flushing, pressurising the system, leakage testing vacuumisation and gas charging with refrigerant gas (R-134) at apprporiate pressure including testing at site of AC 7.5 TR capacity Package type AC complete all as specified & directed by Engr-in -charge. |
| 44 | M&L for removing the conderser fan/blower motor from Package type Air conditioner of 7.5 TR cap with new motor and refixing of motor in original position with new washers nuts & bolts incl testing complete all as specified & directed by Engr In Charge |
| 45 | S&F in repair fully automatic star delta starter (EASD) type for compressor motor having inbuilt single phase preventor, no volt and under volt protection over load peotection. Reverse phasing protection of suitable capacity as recommended by manufacturer as per the load of the compressor motor all as specified and directed by Engr-in-charge. |
| 46 | M&L for desclaing the complete 7.5 TR package type AC with suitable chemical to remove scales from the piping system to achieve efficiency of system complete all as specified and directed by Engineer-in-Cahrge Please Enable Macros to View BoQ information |