| 1 | FLOATING WETLAND SYSTEM Scope of WorkDesign, supply, installation and commissioning of floating wetland system (900 sqm)Providing HDPE modular floating platformsPlantation of aquatic macrophytesAnchoring system installationComplete installation including fixing, testing and stabilizationTechnical SpecificationsMaterial: UV stabilized HDPECoverage: 25–30% water surfaceDepth: ~0.5 mLoad capacity: ≥150 kg/m²Plants: Indigenous pollutant absorbing speciesPurpose: Reduction of BOD, COD, nutrients |
| 2 | AERATION SYSTEM (10 HP) Scope of WorkSupply and installation of 10 HP aerators (16 nos approx.) Installation of air piping and diffusers Electrical connection and testing Noise control measures Technical SpecificationsMotor: 10 HP, IP55Oxygen transfer efficiency: HighNoise level: 75–85 dBAir delivery: ~155 m³/hrPipe material: SS304/HDPE |
| 3 | MODULAR FLOATING DOCKScope of WorkSupply and installation of modular dock (8 nos approx.) Fixing with anchoring systemProviding access for maintenance Technical Specifications Size: 4m x 4m Material: HDPESurface: Anti-skid Resistant to UV, corrosion Rubber sheet protection |
| 4 | SURFACE AERATOR / MIXERScope of WorkSupply & installation of floating surface aerators (8 nos)Electrical connectionsTesting & commissioningTechnical SpecificationsType: Floating aeratorMotor: Continuous dutyEfficiency: High oxygen transferMaterial: Corrosion resistant |
| 5 | ELECTRICAL ITEMSScope of Work Supply & laying of power cable (~200 m)Installation of panels and push buttonsComplete electrification of system Earthing and safety systemTechnical SpecificationsCable: 4 sq.mm copper FRLS Panels: IP55, powder coated1. Protection: MCB/MCCB, overload relay Earthing: As per IS 3043 |
| 6 | ONLINE MONITORINGSYSTEMScope of Work Supply & installation of sensors and control systemIntegration with monitoring panel Data transmission setupTechnical SpecificationsParameters: DO, pH, temperature Range: DO up to 20 ppmAccuracy: ±5%Output: Pulse/ SCADA compatibleSensor cable: 120 m approx. |
| 7 | SAFETY EQUIPMENTScope of Work Supply of safety items for siteInstallation and placement Technical Specifications Life jackets: 6 nosFloating rings: 1 noFire extinguishersHelmets and PPE |
| 8 | NANO BUBBLE GENERATOR Scope of Work Supply, installation and commissioning of nano bubble system (4 sets)Integration with existing aeration system Technical SpecificationsFlow range: 50–200 m³/hr Oxygen efficiency: 70–80%Motor: 1.5–2 HPTechnology: Nano bubble (<200 nm) |
| 9 | DECORATIVE FOUNTAIN Scope of Work Supply & installation of fountains (9 nos)Electrical and lighting installationTesting and commissioningTechnical SpecificationsDigital power systemLighting: LED basedNozzle: SS/BrassControl panel integrated Floating pad, 6 Feet Dia make in FRP A Class Complete Holder assembly with Water Fountain, 4 Layer Resin Coating with wax filler & Water Proofing Coated. Make-DPS, Stands , Holders used materiel Stainless Steel-304 (Cutting, Threading, Fixing, Welding and painting complete.)Make- DPS |
| 10 | Supply and Installation of Heavy Cascade Central Jet Fountain with six aerated peripheral jet saverage Centre jet Height 20 With Complete required Materials.Nozzle Specification: - Bronze, Gunmetal, Brass Fine quality materiel Shine chrome made on new technology CNC Cutting.Make: - DPS |
| 11 | Supply & Fixing waterproof high power LED lights 18 x3 watts=54watt RGB/Multicolor made out of SS. Manufactured by an ISO 9001 : 2015 Certified Company Suitable to be fitted with emitter type powerLED’s with all in one optical lens of 85% efficiency step pampered glass 8 mm with protection class of IP-68.PVC gland, wire 4 core , Holder SS.304.Make :- DPS (powered By Edison/Panasonic) Rating :- IP-68/ ROHS/ CE |
| 12 | Supply & Fixing of DCC Master Control Device for LED Lights having Specifications:-* DCC Program based controller with master & slave communication.* Push feature to lock any running color chase to a fix Colour.* Pre-Programmed Colour patterns and Load Circuit- Inbuilt with accessories complete, Body – Plastic/PVC, Output Power- 12V DC,Make – DPSn. |
| 13 | Stainless steel mesh 4” suction filter in GI frame with powder coating |
| 14 | Open well submersible Pump Set totally enclosed water filled squirrel cage induction motor water lubricated with oil seals with sleeves and thrust bearing having all rotating parts dynamically balanced for silent operation Suitable for three phase 50 HZ AC supply as per direction, instruction and entire satisfaction of Engineer-in-charge.Motor Body : CI Pump Body : CIMake : Kirloskar/Crompton or equivalent Capacity : 10 HP Three Phase |
| 15 | Supply, installation, testing and commissioning of outdoor type control panel suitable for fountain equipment including wiring, cabling, cable tray control wiring and earthing from control panel to motor, starters etc. The control panel shall be compartmentalize for individual outgoing and shall be made out of 16 SWG CRC sheet in grey color and shall be floor mounted with following. All fittings to be done as per direction of Company.Rating :- IP-65/66 / ROHS/CE Assemble Make :- DPS |
| 16 | Supplying and Fixing of GI ‘B’ Class Fittings and GI Ring For the Nozzle with good quality. All fixing to be done to the entire as high pressure. |
| 17 | Construction: Two-part design connected with SS channel frame (125 mm × 5 mm).Internal polyurethane foam filling for buoyancy and strength.Frame: SS channels (125 mm × 50 mm × 5 mm) for pump and filter mounting. |
| 18 | Supplying and Laying submersible flat/round cables Double-insulated PVC copper wires, fully waterproof. PVC insulated PVC sheathed copper conductor of make Finolex/National/Kalinga/BCI complete as per the direction & entire satisfaction of Engineer in charge.erecting anchor with fixing cable and float . |
| 19 | Installation /Testing /Supervision |
| 20 | Transportation |
| 21 | BIO-CULTURE DOSINGScope of Work Supply of bio-culture for 4 months Monthly dosing in treatment systemTechnical SpecificationsType: Microbial cultureFunction: BOD, COD reduction Compatibility: STP processForm: Liquid/powder |
| 22 | DIFFUSED AERATION SYSTEM Scope of WorkSupply & installation of diffusers and blower (2 sets) Air piping network installationTesting & commissioningTechnical SpecificationsDiffuser: Fine bubble membrane Blower: Energy efficientCapacity: As per designAir distribution: Uniform |
| 23 | Scope of Work Design, supply, installation, testing & commissioning of package STP Civil interface and mechanical installation Complete system integrationTechnical SpecificationsTreatment process: MBBR/ASP/Nano hybrid Treated water quality:BOD < 10 mg/LCOD < 50 mg/LAutomation: PLC / SCADA compatibleSludge handling included ADDITIONAL CONDITIONS (FROM DOCUMENT) |
| 24 | Carriage of material by mechanical transport including loading, unloading and stacking as directed upto a lead of 5 km |
| 25 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth. 1.5m in width as well as 10sqm on plan including disposal of excavated earth, lead upto 50m and lift upto1.5m, disposed earth to be levelled and neatly dressed:All kinds of soil |
| 26 | Filling available excavated earth (excluding rock in trenches, plinth side of foundation etc. in layers not exceeding 20cm. In depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 27 | Clearing jungle including uprooting of rank vegetation, grass, brushwood, trees and saplings of girth upto 30cm measured at a height of 1m above ground level and removal of rubbish upto a 5distance of 50m outside the periphery of the area cleared. |
| 28 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work upto plinth level. : M20 grade Nominal Mix 1:1.5:3 (1 cement:1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). |
| 29 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings, strap beam, raft, bases of columns etc. |
| 30 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing bothways with steel props and removal of formwork for upto floor five level for : Walls (any thickness including attached pilasters, buttresses plinth and string course. |
| 31 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire all complete upto floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 32 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cements and mortar 1:3 (1 cement:3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 33 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement:3 coarse sand) and making good the joints and cost of plastizers (if required excluding the cost of centering, shuttering and reinforcement for Walls (any thickness including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix |
| 34 | P & F M.S. Foot Rests in with C.M., 1:3, standard design in 20mm square M.S. bar 50mm embedded in wall & 10 cms. projected out complete. |
| 35 | Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm wide) |
| 36 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately For the purpose of measurement the entire treated surface will be measured. |
| 37 | Random rubble dry stone Kharanja (soling) under floor. |
| 38 | P & F 60cm. Wide M.S. ladder in open well made of flat iron 32×5mm and 10mm dia bars @200mm c/c with angle iron hold fasts at suitable interval complete as per drawing. |
| 39 | Supplying & Fixing R.C.C. Manholes covers with frame of approved make (Light duty). Size 600 X 600mm (Double seal) |
| 40 | Earthwork in excavation by mechanical means (Hydraulic Excavator )/manual means in foundation trenches or drains (not exceeding1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto1.5m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. :All kinds of soil |
| 41 | Providing Laying Jointing DI Pipe (Ductile iron pipe) of 100 mm dia ISI marked K-7 grade as per IS : 5329-2000 with internal cement mortar lining for potable water with rubber ring (EPDM/ SBR) Joints per IS : 5382-1985 complete including Hydraulic testing & commissioning as per Technical Specification. |
| 42 | P&F Sluice valve of approved code IS 14846 : 2000 make 100 mm dia nominal bore |
| 43 | Providing & Supplying Bio CultureSpecifications:• Target Parameters – BOD, COD & pH etc.• flexible Dosage.• Application Method –Spraying• Should be Compatible with allsystems. |
| 44 | Providing comprehensive Operation and Maintenance Works for Aerators, Constructed Wetlands, Nano-Bubbles System, Trash Skimmers, Fountains, DSTP and all installed energy efficient systems including routine inspection, cleaning, preventive & corrective maintenance, replacement of consumables, chemicals and pruning and harvesting of FTP Plant to ensure nutrient uptake remains at peak efficiency. minor spares, performance monitoring, sampling, testing and reporting to BDA, deployment of required skilled & unskilled manpower, electrical power consumption charges, fuel consumption charges, minor repairs, tools & tackles complete as directed by Engineer-in-Charg. Please Enable Macros to View BoQ information |