| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Sewer Network |
| 3 | Execavation |
| 4 | Excavation for following depth below G.L. for laying of sewers in ordinary soil earth, sand, loam and clay including cutting of jointing pits, trimming dressing leveling refilling of trenches in 20cm layers watering and ramming the same including removal of surplus earth or other dismantled materials up to distance 8KM from the centre of trenches. |
| 5 | 0.00 - 1.50 m BGL |
| 6 | 1.51 - 3.00 m BGL |
| 7 | 3.01 - 4.50 m BGL |
| 8 | 4.51 - 6.00 m BGL |
| 9 | 6.01 - 7.50 m BGL |
| 10 | 7.51 - 9.00 m BGL |
| 11 | TIMBERING |
| 12 | Providing and fix open timbering (covering 1/3rd) of surface area by planks in trenches for the following depth below G.L. Consisting of 40 mm approved country wood planks for poling boards 125mm x 75mm Indian Sal wood walers and 100 mm dia. Sal ballies for shuttering at 1.5m c/c including removal after laying. Both sides will be taken as one side for the purpose of payment and measurements i.e. area equals to length x depth of trenches and dismantled timbering materials will be the property of the contractor. |
| 13 | 0.00 - 3.00 m BGL |
| 14 | Providing and fix close timbering in the trenches for the following depth below G.L. consisting of 40 mm approved country wood planks for poling broads 125 mm x 75 mm Indian Sal wood walers and 100 mm dia. Sal bellies for truing the shuttering at 1.5 M c/c/ including removal after laying of sewers. Both side of trenches will be taken as one side for the purpose of payment and measurement i.e. area equals to length x depth of trenches. Dismantled timbering materials will be the property of the contractor. |
| 15 | 0.00 - 3.00 m BGL |
| 16 | 3.01 - 6.00 m BGL |
| 17 | 6.01 - 9.00 m BGL |
| 18 | Laying of Sewer Network |
| 19 | Supply of following sizes of RCC NP3/NP4 S&S rubber rings joints pipe ,dewatering & rubber ring from factory to site of work including transportations loading, unloading, stacking all taxes excise duty transit insurance etc. complete. |
| 20 | 200 mm dia pipe |
| 21 | 250 mm dia pipe |
| 22 | 300 mm dia pipe |
| 23 | 350 mm dia pipe |
| 24 | 400 mm dia pipe |
| 25 | 450 mm dia pipe |
| 26 | 500 mm dia pipe |
| 27 | 600 mm dia pipe |
| 28 | 700 mm dia pipe |
| 29 | 800 mm dia pipe |
| 30 | 200 mm dia pipe |
| 31 | 250 mm dia pipe |
| 32 | 300 mm dia pipe |
| 33 | 350 mm dia pipe |
| 34 | 400 mm dia pipe |
| 35 | 450 mm dia pipe |
| 36 | 500 mm dia pipe |
| 37 | 600 mm dia pipe |
| 38 | 700 mm dia pipe |
| 39 | 800 mm dia pipe |
| 40 | Carting of following sizes of RCC NP3/NP4 S&S rubber rings joints pipe & rubber ring from store to site of work, lowering gasket the same into trenches and laying true to the alignment and gradient including excavation of earth below invert level of pipes cost of all jointing materials, testing etc. complete. |
| 41 | 200 mm dia pipe |
| 42 | 0.00 - 1.50 m BGL |
| 43 | 1.51 - 3.00 m BGL |
| 44 | 3.01 - 4.50 m BGL |
| 45 | 4.51 - 6.00 m BGL |
| 46 | 6.01 - 7.50 m BGL |
| 47 | 7.51 - 9.00 m BGL |
| 48 | 250 mm dia pipe |
| 49 | 0.00 - 1.50 m BGL |
| 50 | 1.51 - 3.00 m BGL |
| 51 | 3.01 - 4.50 m BGL |
| 52 | 4.51 - 6.00 m BGL |
| 53 | 6.01 - 7.50 m BGL |
| 54 | 7.51 - 9.00 m BGL |
| 55 | 300 mm dia pipe |
| 56 | 0.00 - 1.50 m BGL |
| 57 | 1.51 - 3.00 m BGL |
| 58 | 3.01 - 4.50 m BGL |
| 59 | 4.51 - 6.00 m BGL |
| 60 | 6.01 - 7.50 m BGL |
| 61 | 7.51 - 9.00 m BGL |
| 62 | 350 mm dia pipe |
| 63 | 0.00 - 1.50 m BGL |
| 64 | 1.51 - 3.00 m BGL |
| 65 | 3.01 - 4.50 m BGL |
| 66 | 4.51 - 6.00 m BGL |
| 67 | 6.01 - 7.50 m BGL |
| 68 | 7.51 - 9.00 m BGL |
| 69 | 400 mm dia pipe |
| 70 | 0.00 - 1.50 m BGL |
| 71 | 1.51 - 3.00 m BGL |
| 72 | 3.01 - 4.50 m BGL |
| 73 | 4.51 - 6.00 m BGL |
| 74 | 6.01 - 7.50 m BGL |
| 75 | 7.51 - 9.00 m BGL |
| 76 | 450 mm dia pipe |
| 77 | 0.00 - 1.50 m BGL |
| 78 | 1.51 - 3.00 m BGL |
| 79 | 3.01 - 4.50 m BGL |
| 80 | 4.51 - 6.00 m BGL |
| 81 | 6.01 - 7.50 m BGL |
| 82 | 7.51 - 9.00 m BGL |
| 83 | 500 mm dia pipe |
| 84 | 0.00 - 1.50 m BGL |
| 85 | 1.51 - 3.00 m BGL |
| 86 | 3.01 - 4.50 m BGL |
| 87 | 4.51 - 6.00 m BGL |
| 88 | 6.01 - 7.50 m BGL |
| 89 | 7.51 - 9.00 m BGL |
| 90 | 600 mm dia pipe |
| 91 | 0.00 - 1.50 m BGL |
| 92 | 1.51 - 3.00 m BGL |
| 93 | 3.01 - 4.50 m BGL |
| 94 | 4.51 - 6.00 m BGL |
| 95 | 6.01 - 7.50 m BGL |
| 96 | 7.51 - 9.00 m BGL |
| 97 | 700 mm dia pipe |
| 98 | 0.00 - 1.50 m BGL |
| 99 | 1.51 - 3.00 m BGL |
| 100 | 3.01 - 4.50 m BGL |
| 101 | 4.51 - 6.00 m BGL |
| 102 | 6.01 - 7.50 m BGL |
| 103 | 7.51 - 9.00 m BGL |
| 104 | 800 mm dia pipe |
| 105 | 0.00 - 1.50 m BGL |
| 106 | 1.51 - 3.00 m BGL |
| 107 | 3.01 - 4.50 m BGL |
| 108 | 4.51 - 6.00 m BGL |
| 109 | 6.01 - 7.50 m BGL |
| 110 | 7.51 - 9.00 m BGL |
| 111 | Bedding |
| 112 | Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. |
| 113 | 0.00 - 1.50 m BGL |
| 114 | 1.51 - 3.00 m BGL |
| 115 | 3.01 - 4.50 m BGL |
| 116 | 4.51 - 6.00 m BGL |
| 117 | 6.01 - 7.50 m BGL |
| 118 | 7.51 - 9.00 m BGL |
| 119 | Lean Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:4:8) including supply of all materials, labour, T&P etc. required for the proper completion of work. |
| 120 | 0.00 - 1.50 m BGL |
| 121 | 1.51 - 3.00 m BGL |
| 122 | 3.01 - 4.50 m BGL |
| 123 | 4.51 - 6.00 m BGL |
| 124 | 6.01 - 7.50 m BGL |
| 125 | 7.51 - 9.00 m BGL |
| 126 | Well graded crushed rock/ gravel max size 25mm including supply of all materials, labour, T&P etc. into the trenches for bedding of DWC/RCC Pipes including watering compaction, labour T&P etc. for completion of work. |
| 127 | 0.00 - 1.50 m BGL |
| 128 | 1.51 - 3.00 m BGL |
| 129 | 3.01 - 4.50 m BGL |
| 130 | 4.51 - 6.00 m BGL |
| 131 | 6.01 - 7.50 m BGL |
| 132 | 7.51 - 9.00 m BGL |
| 133 | Construction of circular type brick masonary/RCC manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), foundation concrete 1:4:8 graded stone aggregate other than granite 40mm nominal size, wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:3 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete as per specifications. |
| 134 | 900mm internal dia., 1.65m deep |
| 135 | 1200mm internal dia., 2.30m deep |
| 136 | 1500mm internal dia., 4.95m deep |
| 137 | 1500mm internal dia., 9.0 m deep |
| 138 | Same as item no 135 for Regulation of Shafts plus/minus from the above mentioned depth |
| 139 | 900mm internal dia., 1.65m deep |
| 140 | 1200mm internal dia., 2.30m deep |
| 141 | 1500mm internal dia., 4.95m deep |
| 142 | 1500mm internal dia., 9.0 m deep |
| 143 | Dismantling/Cutting of the following type of road for laying sewers, manholes, sewer connection chambers etc. including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. |
| 144 | Bituminous road |
| 145 | Concrete road |
| 146 | Interlocking tile road |
| 147 | B.O.E road |
| 148 | Permanent re-instatement of the following ty pe of road surface after laying of sewer line including supply of all materials, labour, T&P etc. required for completion of work. it also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning surface for proper completion of the work as per directions of Engineer ‐in ‐charge. |
| 149 | Bituminous road (PWD) -(20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20% |
| 150 | Bituminous road (Nagar Nigam) (20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20% |
| 151 | C.C. Road in M25 grade, minimum thickness 15cm on 20cm th. sand & 15 .cm th. PCC (M15) filling base & 10 cm GSB |
| 152 | Interlocking Road (existing usable Interlocking bricks M-30 grade, on 20cm local sand & 10cm TH. PCC 1:6:12). Incl. Entire surface Spreading 3 cm local sand for paste of brick & joint filling |
| 153 | BOE Road (15 Cm. sand with first class brick 50% New and 50% Old) |
| 154 | Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating and Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions. |
| 155 | 200 mm dia pipe, 6mm Pipe Wall Thickness |
| 156 | 250 mm dia pipe, 6mm Pipe Wall Thickness |
| 157 | 300 mm dia pipe, 6mm Pipe Wall Thickness |
| 158 | 350 mm dia pipe, 6mm Pipe Wall Thickness |
| 159 | 400 mm dia pipe, 6mm Pipe Wall Thickness |
| 160 | 450mm dia pipe, 8mm Pipe Wall Thickness |
| 161 | Provision for laying of sewer by Trenchless Technology including Supply of different size of MS Pipe, Labour T&P etc. required for Proper Completion of the Work. |
| 162 | 500 mm (with 12 mm thick M.S. pipe cost) |
| 163 | 600 mm (with 12 mm thick M.S. pipe cost) |
| 164 | 700 mm (with 12 mm thick M.S. pipe cost) |
| 165 | 800 mm (with 12 mm thick M.S. pipe cost) |
| 166 | Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Eucalyptus Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. |
| 167 | Disposal of Surplus Earth |
| 168 | Diversion of Existing Sewer line during laying of New Sewer includding Supply of 7.1 mm thick MS pipe size 200 mm dia and as per requirement of site condition including cost of ms pipe ms bend flange nut volt rubber packing also including hiring of DG set welding machine and gas cutter all labour material etc complete10% of Total Length and re- use of pipe |
| 169 | Dewatering work during laying of pipe line and construction of manhole |
| 170 | Provision for Sand filling in trench for cuision of pipe |
| 171 | Provision for shifting and reinstatement of electric and telephone poles during excavation and laying of sewer lines. |
| 172 | Provision for shifting of electric and telephone cable, gas pipeline, existing water supply mains falling in the alignment of conveying main during excavation and the restoring utilities / services to its original condition. etc. during excavation and laying of sewer lines. |
| 173 | Sewer House Connection |
| 174 | Construction of House Connecting chambers for two connections of size 0.6 x 0.6 x 0.75m |
| 175 | Making Domestic Sewer connection using 110mm HDPE pipe PN-6, PE-100 |
| 176 | Laying of Sewer line from House Connecting chambers to M.H using 160mm HDPE pipe PN-6, PE-100 |
| 177 | Sewer inter connecting chamber to intercept the waste water from toilet,kitchen and bathroom 0.3x0.3x0.45m |
| 178 | Rising Main |
| 179 | Execavation |
| 180 | Excavation for following depth below G.L. for laying of sewers in ordinary soil earth, sand, loam and clay including cutting of jointing pits, trimming dressing leveling refilling of trenches in 20cm layers watering and ramming the same including removal of surplus earth or other dismantled materials up to distance 50m from the centre of trenches. |
| 181 | 0.00 - 1.50 m BGL |
| 182 | Providing, Supplying, laying, jointing & field testing at site as per specifications of centrifugally cast (spun) following dia Pressure Pipes with epoxy internal coaating and externally painting for sewerage confirming to IS 8329:2000 (amended upto date) with push on type EPDM 'ISI marked' rubber gasket (including cost of rubber gasket) joining as per IS 5382 specifications. Pipes shall be out side Zinc coated with finishing layer of Bitumen and have factory internal cement mortar lining. The rates include all the cost of material, cost of specials, all local and central taxes, labour required, transportation, loading, unloading, conveyance to site and stacking including lowering, laying & jointing with DI pipes and specials, etc. complete and giving satisfactory hydraulic field testing, commissioning as per specifications etc., complete as directed by Engineer. The pipe shall be ISI marked. |
| 183 | 300mm Dia DI K-9 |
| 184 | 450mm dia DI K-9 |
| 185 | Providing, Erecting, Testing, Commissioning, of C.I. double ball orifice type 100 mm dia Air Valve inclusive of all taxes, transportation, insurance, Confirming to IS. With Construction of 350x350x500 mm size air valve chamber as per type design including supply & fixing of 50 mm dia medium duty perforated C.I. cover. |
| 186 | Dismantling/Cutting of the following type of road for sewer house connection including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. |
| 187 | Bituminous road |
| 188 | Permanent re-instatement of the following ty pe of road surface after laying of sewer line including supply of all materials, labour, T&P etc. required for completion of work. it also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning surface for proper completion of the work as per directions of Engineer ‐in ‐charge. |
| 189 | Bituminous road (Nagar Nigam) |
| 190 | Disposal of Surplus Earth |
| 191 | Provision for Sand filling in trench for cuision of pipe |
| 192 | Effluent Line |
| 193 | Execavation |
| 194 | Excavation for following depth below G.L. for laying of sewers in ordinary soil earth, sand, loam and clay including cutting of jointing pits, trimming dressing leveling refilling of trenches in 20cm layers watering and ramming the same including removal of surplus earth or other dismantled materials up to distance 50m from the centre of trenches. |
| 195 | 0.00 - 1.50 m BGL |
| 196 | 1.51 - 3.00 m BGL |
| 197 | TIMBERING |
| 198 | Providing and fix open timbering (covering 1/3rd) of surface area by planks in trenches for the following depth below G.L. Consisting of 40 mm approved country wood planks for poling boards 125mm x 75mm Indian Sal wood walers and 100 mm dia. Sal ballies for shuttering at 1.5m c/c including removal after laying. Both sides will be taken as one side for the purpose of payment and measurements i.e. area equals to length x depth of trenches and dismantled timbering materials will be the property of the contractor. |
| 199 | 0.00 - 3.00 m BGL |
| 200 | Supply, Carting of following sizes of RCC NP3/NP4 S&S rubber rings joints pipe & rubber ring from factory to site of work, lowering gasket the same into trenches and laying true to the alignment and gradient including excavation of earth below invert level of pipes cost of all jointing materials, testing etc. complete. also including transportations loading, unloading, stacking all taxes excise duty transit insurance etc. complete. |
| 201 | NP3 600 mm dia pipe |
| 202 | 1.51 - 3.00 m BGL |
| 203 | Bedding |
| 204 | Well graded crushed rock/ gravel max size 25mm including supply of all materials, labour, T&P etc. into the trenches for bedding of DWC/RCC Pipes including watering compaction, labour T&P etc. for completion of work. |
| 205 | 1.51 - 3.00 m BGL |
| 206 | Construction of circular type brick masonary/RCC manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), foundation concrete 1:4:8 graded stone aggregate other than granite 40mm nominal size, wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:3 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete as per specifications. |
| 207 | 1200mm internal dia., 2.30m deep |
| 208 | Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Eucalyptus Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. |
| 209 | Providing and erecting 2.00 metre high temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. |
| 210 | Disposal of Surplus Earth |
| 211 | Provision for Sand filling in trench for cuision of pipe |
| 212 | SEWAGE PUMPING STATION (SPS) |
| 213 | Design, Construction, Supply of all materials, Erection and Commissioning of SPS (11.0 MLD) with all the civil, LT/HT panel Room, DG set foundation, Pump House, Boundry wall, Internal Road, Gate etc. all complete including all neccessary work as neccesity. |
| 214 | Design, Construction, Supply of all materials, Erection and Commissioning of SPS (04.0 MLD) with all the civil, LT/HT panel Room, DG set foundation, Pump House, Boundry wall, Internal Road, Gate etc. all complete including all neccessary work as neccesity. |
| 215 | Sewage Treatment Plant (10.0 MLD) |
| 216 | Design, Construction, Supply of all materials, Erection and Commissioning of STP (10.0 MLD Sewage Treatment Plant ) with all the civil, electrical, mechanical, instrumentation and scada system, LT/HT panel, sub station building, DG set foundation, admin buidling, Staff Quarter, laboratories, meter room, Boundry wall, Internal Road, Gate etc. all complete with co-treatment facilities. The quality of treated effluent shall be as per CPHEEO Manual for agricultural uses. The rate is considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentration mentioned in CPHEEO manual's table 5.4. including all electrical/mechanical parts along with the power connection charges from hydle from a independent feeder |
| 217 | E&M Works |
| 218 | (A) SPS-1 |
| 219 | VFD starter For 50 HP pump set |
| 220 | SUBMERSIBLE PUMP SET: |
| 221 | Submersible sewage non-clog pumps withJacket cooled Integreated Motor of IP 68Protection for 400±10% V AC, 3phase 50 Hz. suitable to pump raw sewage with specific gravity of 1.05 and also capable to handle solids up to 135mm size with all suitable piping and specials having following material of construction.Casing- 2%NiCIImpeller- ASTM CF8MShaft & Shaft sleeve- ASTM SS 410 included Automatic Coupling system,Guide rail system comprises of Pedestal, bracket, upper guide rail holder,Guide pipe for above 6 sets pumps length upto sumpwell floor level. etc. |
| 222 | 86 LPS, 25 m Head, 980 RPM |
| 223 | CAPACITOR: |
| 224 | Provision for supply of shunt type power factor improvement capacitor of suitable to boost the power factor up to 0.95.as per direction of engineer incharge |
| 225 | MAIN PIPING & VALVES: |
| 226 | Provision for main piping and valves for 250 mm dia, and 450 mm dia common header line(sizes can be change as per site condition & requirement) |
| 227 | Motor operated Sluice Valve with actuator |
| 228 | CIDF 450 mm ø |
| 229 | CIDF 250 mm ø |
| 230 | Reflex Valve |
| 231 | CIDF 250 mm ø |
| 232 | CIDF 450 mm ø |
| 233 | CIDF Pipe dia 450 mm |
| 234 | CIDF Pipe dia 250 mm |
| 235 | Pipe fittings as CIDF Tee 250x 450 mm.SS blind flange dia 250 mm,90 degree bend dia 450 mm,90 degree bend dia 250 mm,90 degree duckfoot bend dia 250 mm,Reducer/Enlarger CIDF Reducer/Enlarger 200 mmx 250 mm ,CIDF 90 degree duckfoot bend dia 200 mm asper site requirements |
| 236 | Dismenaling joints 250 mm |
| 237 | Dismenaling joints 450 mm |
| 238 | Nut and bolts with washer(SS) M20x120,M24x120,M27x140 as per site requirements |
| 239 | Necessary Piping , pump set & valve foundation , rubber packing, insertion and other material as per required/direction of engineer incharge. |
| 240 | Electromagnetic Flow Meter: |
| 241 | (i) Providing, Installation, Testing and commissioning of 450 mm ELECTRO MAGNETIC FLOW METER cum totalizer having following charecteristics/MOC: Liner: Polyurethane or Hard Rubber / Electrode MOC: SS316L /Housing : Die Cast Aluminium or CS / Power Supply: 90-230 V AC / Output: 4-20mA with HART / Sensor Cable : 10 mt / Flow Tube or Sensor housing protection IP68 / Process Flange : SS316 / Display : 3 1/2 LCD Display / Cable Connection : 1/2\\"NPT /Accuracy : 0.5% |
| 242 | (ii) CVT with control cables |
| 243 | Supply, installation and commissioning of 3 T Mono Rail Single Girder having suitable lift with chain, pulley block and traveling trolley complete |
| 244 | Tools & Plants as per mentioned in tender documents and direction of engineer incharge |
| 245 | Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher. |
| 246 | 12/20 mm. thick rubber electric resistance rubber sheet as per ISS. |
| 247 | Steel revolving high quality chairs |
| 248 | Fire bucket with stand as per direction of engineer incharge |
| 249 | Steel Almirah of 6’x3' |
| 250 | moduler Table & their chairs 6 Nos |
| 251 | Installation & Commissioning: |
| 252 | Installation & Commissioning of all 6 Nos. pump sets, piping & valves, guide rail, lifting tackle etc. complete in all respect. as per direction of engineer incharge and as per specification of tender documents |
| 253 | Painting |
| 254 | Provision for painting of all pumps, piping and valves with two coat enamel paint as per direction of engineer incharge |
| 255 | Light Wiring |
| 256 | Light wiring of Pump House, L.T. control room, Meter room, D.G. room, Store and Staff Quarters with entire required qty of LED lights,fluroescent lights, campus lighting etc.Supply and fixing of 125 watt LED fixture with lamp and its all accessories. complete in all as per direction of EIC |
| 257 | Supply & fitting of GI swaged tubular poles of 9M length as per I.E. rules. |
| 258 | Supply and laying of 35sq mm Cu conductor XLPE insulated 3.5 core submersible cable from Composite panel to pumps (50 HP) as per specification given in tender documents(paid as per actual basis) |
| 259 | Aluminium Junction Box |
| 260 | SITC of Exhaust fans of suitable sweep/capacity as per direction of engineer incharge |
| 261 | Complete double earthing of all pumping plant with all accessories as earth pipe of size (40 mm dia x 5 mm thick),earth strip of size (50 mm x 6 mm) and required material as per direction of engineer incharge and as per specification given in tender documents |
| 262 | Necessory safety equipments such as safety helmet with led head lamp,Yelllow helmet-9 nos,white helmet-4 nos,green helmet-1 no(explosion proof),safety belt with rope-6 nos,protective gloves for Lt Line & Ht Line,fluroscent jacket-9 nos,gas masks and self-contained breathing appratus-2 nos,eye protector-2 nos,air blowers-2 nos ,Electronic Multi Gas Detector,portable alluminum ladder,safety sign board-6 nos,first add box and sewage sump cleaning equipment as per direction of EIC |
| 263 | L.T. Pannel |
| 264 | 2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items as follows -Incoming/Outgoing panels L.T. control panel having 4 Nos. (or suitable nos for synchronization) incoming having 400 amp ACB draw out type & outgoing Panels (6 No.) 200 amp microprocesor based mccb , 2 Nos -63 Amp microprocesor based MCCB for aux light & suitable to operated on 400 ± 6 % volt , 3 Phase , 50 Hz, AC supply ,with C.Ts,P.T AVF Meter,KWH meter P.F Meter, Bus Bar chamber, Relays and other Protective Devices Complete in all Respects.Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU. Panel will include synchronization systems for Transformer and DG set, Suitable capacity APFC panel for non VFD Laod. as per technical specificatons and mentioned in tender documents direction of EIC |
| 265 | Supply and making end termination/joints of the above cable as per direction of engineer incharge |
| 266 | Complete double Earthing of panel with GI pipe (40 mm dia x 5 mm thick) & earthing strip of size (50 mm x 6 mm) electrical equipments as per IS/ IER & direction of engineer encharge |
| 267 | Proper fencing of sub-station portion with size of angle 50 mm X 50 mm X 5mm and cross support with MS strip 5 mm size thick also as per IE Rules as per direction of engineer incharge and as per technical specifications |
| 268 | Charges of Electrical safety clearance. |
| 269 | Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.as per direction of engineer incharge |
| 270 | 12/20 mm. thick rubber electric resistance rubber sheet as per ISS. |
| 271 | Erection L.T. panels, laying of required cables & filling L.T. Cable end boxes as detailed above.laying of cable should be through channel of brick work and as per direction of engineer in charge |
| 272 | Exhaust fans of suitable sweep/capacity including loovers as per direction of engineer incharge |
| 273 | Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary. |
| 274 | Testing at manufacturer works & site of L.T. Panels |
| 275 | Construction of Sub-Station |
| 276 | 11 KV floor mounting, single row type H.T. panel having 1 No. incoming and 2 Nos. outgoing VCB(630Amp) panels complete with insulated bus bars, all necessary metering and safety equipments. |
| 277 | 11 KV / 0.400 KV,250 KVA outdoor, step down transformers |
| 278 | 11 KV XLPE cable of 3 x 150 sqmm size/suitable size Al. armoured cable from meter to HT panel(paid as per actual basis) |
| 279 | (D) Supply of 0.44 KV capacitor bank complete with all accessories. |
| 280 | (E) Cable Jointing Kit |
| 281 | (i) H.T. indoor type |
| 282 | (ii) H.T. outgoing type |
| 283 | (iii) L.T. indoor type |
| 284 | (F) Double earthing of all sub-station equipments complete with salt, charcoal, G.I. earth electrode, C.I. earth boxes, G.I. watering pipe, G.I. earth strip of adequate capacity and should not less than 50mmX 8 mm and required labour &t&p, .as per direction of engineer incharge |
| 285 | (I) Supply & fixing of M.S. checkered plate over cable trenches minimum thickness not less than 8 mm as per direction of engineer incharge |
| 286 | (J) Miscellaneous work as barbad wire on 50x50x5 mm ms angle ,with bolder fencing of switch yard construction of cable trenches, Safety Equipments i.e Fire Extinguisher ,Sand Bucket ,etc etc.as per direction of engineer incharge |
| 287 | (K) Erection and commissioning of all sub-station equipments as per direction of engineer incharge |
| 288 | (L) Testing of all equipments of sub-station at manufacturer’s works |
| 289 | (L) Construction of foundations of Transformers and panels Hight should be one meter above ground level |
| 290 | Manual bar Screen |
| 291 | Provision of Stainless Steel(SS 316) manual coarse bar screen having clear gap between screen bar- 50 mm size of flat shall be 50mm x 10mm angle of installation 70º . Complete |
| 292 | Mechanical Bar Screen |
| 293 | Provision of Stainless Steel (SS 316) mechanical bar screen having clear gap between screen bar- 20 mm, size of SS flat shall be 50 mm x 10 mm, angle of installation - 70º duly suitable for width followed with conveyer system, electric motor, starter, cable, panel, bins etc. (for peak flow upto 20 MLD) |
| 294 | Sluice Gate |
| 295 | Provision of CI Thimble Mounted Sluice Gate with motor, actuator operated, Rising Spindle type. Sluice gates are as per IS 13349 Including all taxes, Freight, loading, unloading, fitting in position including Sluice gates are upward opening wall thimble mounted suitable for isolating the flow of sewer into out of the opening in the wall. It consists Gate frame, wall thimble, gate slide, shutter, seating/sealing faces .The gates will be provided with pads on sides, top and bottom to mount the wedges. The gate shall be designed in such a manner, so that it can be operated at 2 meter head. Gate frame & Shutter of CI Grade IS 210 FG 260, Head Stock assembly bolts & SS ASTM A276 Type316, Stem, Operating Nut SS ASTM A276 Type 316., Duly tested for tensile strength, Tested for over all dimensions as per approved GA drawing complete in all respect as per specification and direction of Engineer,screen upto size 700x700mm |
| 296 | Provision of CI Thimble Mounted Sluice Gate with motor, actuator operated, Rising Spindle type. Sluice gates are as per IS 13349 Including all taxes, Freight, loading, unloading, fitting in position including Sluice gates are upward opening wall thimble mounted suitable for isolating the flow of sewer into out of the opening in the wall. It consists Gate frame, wall thimble, gate slide, shutter, seating/sealing faces .The gates will be provided with pads on sides, top and bottom to mount the wedges. The gate shall be designed in such a manner, so that it can be operated at 2 meter head. Gate frame & Shutter of CI Grade IS 210 FG 260, Head Stock assembly bolts & SS ASTM A276 Type316, Stem, Operating Nut SS ASTM A276 Type 316., Duly tested for tensile strength, Tested for over all dimensions as per approved GA drawing complete in all respect as per specification and direction of Engineer,inlet and bypass and 2 no forsize 1000x1000 at inlet chamber & bypass |
| 297 | Testing of above equipment at manufacturer works |
| 298 | Installation & Commissioning |
| 299 | Installation & commissioning of all screens and sluice gates complete. |
| 300 | Diesel Generating sets. |
| 301 | Supply of 160 KVA DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start ,Batteries, Fuel tank ( with Stand) & piping , control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments,accoustic enclosure,Noise level is less than 74 db(A) at a distance of 1 Mtrs, 0.8 pf(lag) 415 V, 3 Ø, 50 Hz capacity with Provision for PLC based AMF Panel fabricated from CRCA sheet steel 2 mm thick, powder coated finish, START & STOP commands, control relays, selector switches for Ammeter and Voltmeter, Ammeter & Voltmeter, Control & Power contactors, timers, electronic hooters, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for above DG set,as per technical specifications mentioned in tender documents & direction of EIC |
| 302 | Fuel tank as per site requirment. |
| 303 | Batteries 24 volt 360AH dry and uncharged with battery leads and battery charger |
| 304 | Double earthing of DG set and all electrical equipment as per IIEC rule |
| 305 | POWER CABLE/BUS BAR |
| 306 | Supplying and laying of Power cable of Suitable size of 415 Volt grade 2R x 150 sqmm 3.5 core armoured XLPE sheathed aluminium conductor from Transformer & DG set to Main LT Panel. (paid as per actual basis) |
| 307 | Supply and making end termination/joints of the above cable as per direction of engineer incharge |
| 308 | Electric Resistance Rubber sheets. |
| 309 | Provision for 12/20mm thick electric resistance rubber sheets as per direction of engineer incharge |
| 310 | INSTALLATION, COMMISSIONING AND TESTING |
| 311 | Installation, Testing of D.G. set, cable, AMF panel etc.at site as per direction of engineer incharge. HSD and Lubricat oil initially complitly fill by bidder FOC. |
| 312 | Commissioning of the above including supply of diesel and oil for trial |
| 313 | Testing of D.G set at manufacturer works |
| 314 | Automation of SPS-2 |
| 315 | CE/UL certified local conrol room PLC/RTU with redundant CPU& power supply in IP 54 enclouser to communiate with gsm based modem unit with redundant cpu & power supply with analog and digital parameter and features as per spec mentioned in technical bid documents. |
| 316 | GSM/GPRS based wireless communication hardware for RTUs. Capable to transfer data from site to LCS with all accessories etc complete. |
| 317 | Intelligent energy meter |
| 318 | Smart Pressure transmitter |
| 319 | Auto phase reversal unit/Automatic transfer switch with inbuilt time delay and enclosure (Conforming to IEC 60947-1 & IEC 60947-6-1) of suitable for 400 Amp. rating |
| 320 | Cabling of all equipments & control cable |
| 321 | Security survelliance IP camera |
| 322 | Radar type level transmitter with RTU communication |
| 323 | Control Panel with IP 65 protection, industrial grade 24 V power supply and other required items |
| 324 | 3 phase Surge protector for all AC control supplies to all the equipment |
| 325 | 7\\" HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters |
| 326 | Installation, testing and commissioning |
| 327 | (B) transmission line for 11 mld stp plant (payment shall be made as per actual transmission line charges & reimbursed by department) |
| 328 | Testing and trial run including manpower,consumable items like HSD,Lube oil (paid as per actual consumption) |
| 329 | For SPS-2 |
| 330 | VFD starter For 20 HP pump set |
| 331 | SUBMERSIBLE PUMP SET: |
| 332 | Submersible sewage non-clog pumps withJacket cooled Integreated Motor of IP 68Protection for 400±10% V AC, 3phase 50 Hz. suitable to pump raw sewage with specific gravity of 1.05 and also capable to handle solids up to 135mm size with all suitable piping and specials having following material of construction.Casing- 2%NiCIImpeller- ASTM CF8MShaft & Shaft sleeve- ASTM SS 410 included Automatic Coupling system,Guide rail system comprises of Pedestal, bracket, upper guide rail holder,Guide pipe for above 6 sets pumps length upto sumpwell floor level. etc. |
| 333 | 33 LPS, 20.34 m Head, 980 RPM 20 HP |
| 334 | CAPACITOR: |
| 335 | Provision for supply of shunt type power factor improvement capacitor of suitable to boost the power factor up to 0.95. |
| 336 | MAIN PIPING & VALVES: |
| 337 | Provision for main piping and valves for 200 mm dia, and 300 mm dia common header line (sizes can be change as per site condition & requirement) |
| 338 | Motor operated Sluice Valve with actuator |
| 339 | CIDF300 mm ø |
| 340 | CIDF 200 mm ø |
| 341 | Reflex Valve |
| 342 | CIDF 200 mm ø |
| 343 | CIDF 300mm ø |
| 344 | Piping |
| 345 | DIDF Pipe dia 300 mmX 3 m |
| 346 | DIDF Pipe dia 200 mm X 3M |
| 347 | CIDF Tee 300x200x300 mm,DI blind flange dia 300 mm, bend dia 300 mm,200 mm dia,duckfoot bend dia 200 mm,CIDF Reducer/Enlarger 300 mmx200 mm ,Reducer/Enlarger 150 mmx 200 mm as per requirement of site & direction of EIC |
| 348 | Dismenaling joints 200 mm |
| 349 | Dismenaling joints 300 mm |
| 350 | Nut and bolts with washer(SS) M20x120,(SS) M24x120,(SS) M27x140 |
| 351 | Necessary Piping pump set foundation rubber packing, insertion and other material |
| 352 | Electromagnetic Flow Meter: |
| 353 | (i) Providing, Installation, Testing and commissioning of 300 mm ELECTRO MAGNETIC FLOW METER cum totalizer having following charecteristics/MOC: Liner: Polyurethane or Hard Rubber / Electrode MOC: SS316L /Housing : Die Cast Aluminium or CS / Power Supply: 90-230 V AC / Output: 4-20mA with HART / Sensor Cable : 10 mt / Flow Tube or Sensor housing protection IP68 / Process Flange : SS316 / Display : 3 1/2 LCD Display / Cable Connection : 1/2\\"NPT /Accuracy : 0.5% |
| 354 | (ii) CVT with control cables |
| 355 | LIFTING TACKLE: |
| 356 | Supply, installation and commissioning of 3 T Mono Rail Single Girder having suitable lift with chain, pulley block and traveling trolley complete |
| 357 | Tools & Plants as per mentioned in tender documents and direction of engineer incharge |
| 358 | Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher. |
| 359 | 12/20 mm. thick rubber electric resistance rubber sheet as per ISS. |
| 360 | Steel chairs. |
| 361 | Fire bucket with stand |
| 362 | Steel Almirah of 6’x3’ |
| 363 | Steel Tubular Table |
| 364 | Installation & Commissioning: |
| 365 | Installation & Commissioning of all 6 Nos. pump sets, piping & valves, guide rail, lifting tackle etc. complete. |
| 366 | Painting |
| 367 | Provision for painting of all pumps, piping and valves with two coat enamel paint as per direction of engineer incharge. |
| 368 | Light Wiring |
| 369 | Light wiring of Pump House, L.T. control room, Meter room, D.G. room, Store and Staff Quarters with entire required qty of LED lights,fluroescent lights, campus lighting etc.Supply and fixing of 125 watt LED fixture with lamp and its all accessories. complete in all as per direction of EIC |
| 370 | Supply & fitting of steel swaged tubular poles of 9M length as per I.E. rules. |
| 371 | Supply and laying of 10 sq mm Cu conductor XLPE insulated 3.5 core submersible cable from Composite panel to pumps (20 HP) (paid as per actual basis) |
| 372 | Aluminium Junction Box as per direction of engineer incharge. |
| 373 | SITC of Exhaust fans of suitable sweep/capacity with loovers as per direction of engineer incharge |
| 374 | Complete double earthing of all pumping plant with all accessories as earth pipe of size (40 mm dia x 5 mm thick),earth strip of size (50 mm x 6 mm) and required material as per direction of engineer incharge and as per specification given in tender documents |
| 375 | Necessory safety equipments such as safety helmet with led head lamp,Yelllow helmet-7 nos,white helmet-3 nos,green helmet-1 no(explosion proof),safety belt with rope-4 nos,protective gloves for Lt Line & Ht Line,fluroscent jacket-6 nos,gas masks and self-contained breathing appratus-2 nos,eye protector-2 nos,air blowers-2 Nos,Electronic Multi Gas Detector,portable alluminum ladder,safety sign board-6 nos,first add box and sewage sump cleaning equipment as per direction of EIC |
| 376 | L.T. Pannel |
| 377 | 2mm thick CRCA sheet fabricated factory wired dust, damp and vermin proof metal clad cubical and floor mounted single row type control panel for system voltage 400+10%, 50 Hz, comprising of following items |
| 378 | Incoming/Outgoing panels |
| 379 | L.T. control panel having 4 Nos. (or suitable nos for synchronization) incoming having 250 amp MCCB draw out type & outgoing Panels (6 No.) 100 amp microprocesor based mccb , 2 Nos -63 Amp microprocesor based MCCB for aux light & suitable to operated on 400 ± 6 % volt , 3 Phase , 50 Hz, AC supply ,with C.Ts,P.T AVF Meter,KWH meter P.F Meter, Bus Bar chamber, Relays and other Protective Devices Complete in all Respects.Control panel is also suitable to meet the basic requirements of motor protection such as No volt and under voltage protection and thermal over load protection. Panel will be connected with PLC/RTU. Panel will include synchronization systems for Transformer and DG set, Suitable capacity APFC panel for non VFD Laod with all protection & techncial specification mentiond in tender doc.& direction of EIC |
| 380 | Supply and making end termination/joints of the above cable |
| 381 | Supply and making end termination of the above cable |
| 382 | Complete double Earthing of panel with GI pipe (40 mm dia x 5 mm thick) & earthing strip of size (50 mm x 6 mm) electrical equipments as per IS/ IER & direction of engineer encharge |
| 383 | Proper fencing of sub-station portion with size of angle 50 mm X 50 mm X 5mm and cross support with MS strip 5 mm size thick also as per IE Rules as per direction of engineer incharge and as per technical specifications |
| 384 | Charges of Electrical safety clearance. |
| 385 | Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher.as per direction of engineer incharge |
| 386 | 12/20 mm. thick rubber electric resistance rubber sheet as per ISS. |
| 387 | Erection L.T. panels, laying of required cables & filling L.T. Cable end boxes as detailed above.laying of cable should be through channel of brick work and as per direction of engineer in charge |
| 388 | Exhaust fans of suitable sweep/capacity |
| 389 | Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary. |
| 390 | Testing at manufacturer works L.T. Panels |
| 391 | Construction of Sub-Station |
| 392 | (A) 11 KV floor mounting, single row type H.T. panel having 1 No. incoming and 2 Nos. outgoing VCB(630Amp) panels complete with insulated bus bars, all necessary metering and safety equipments. |
| 393 | (B) 11 KV / 0.400 KV,125 KVA outdoor, step down transformers |
| 394 | (C) 11 KV XLPE cable of 3 c x70 sqmm/suitable size Al. armoured cable from Meter To HT Panel & HT panel To transformer (paid as per actual basis) |
| 395 | Supply of 0.44 KV capacitor bank complee with all accessories. |
| 396 | (E) Cable Jointing Kit |
| 397 | (i) H.T. indoor type |
| 398 | (ii) H.T. outgoing type |
| 399 | (iii) L.T. indoor type |
| 400 | Double earthing of all sub-station equipments complete with salt, charcoal, G.I. earth electrode, C.I. earth boxes, G.I. watering pipe, G.I. earth strip of adequate capacity and should not less than 50mmX 8 mm and required labour &t&p, .as per direction of engineer incharge |
| 401 | (I) Supply & fixing of M.S. checkered plate over cable trenches |
| 402 | Miscllenous work as barbad wire fencing of switch yard construction of cable trenches, Safety Equipments i.e Fire Extinguisher ,Sand Bucket ,etc etc. |
| 403 | Erection and commissioning of all sub-station equipments |
| 404 | Testing of all equipments of sub-station at manufacturer’s works |
| 405 | Construction of foundations of Transformers and panels |
| 406 | Manual bar Screen |
| 407 | Provision of Stainless Steel(SS 316) manual coarse bar screen having clear gap between screen bar- 50 mm, size of flat shall be 50mm x 10mm angle of installation 70º . Complete |
| 408 | Mechanical Bar Screen |
| 409 | Provision of Stainless Steel (SS 316) mechanical finebar screen having clear gap between screen bar- 6 mm, size of SS flat shall be 50 mm x 10 mm, angle of installation - 70º duly suitable for 2.44 m wide followed with conveyer system, electric motor, starter, cable, panel, bins etc. (for peak flow upto 10MLD) |
| 410 | Sluice Gate |
| 411 | Provision of CI Thimble Mounted Sluice Gate with motor, actuator operated, Rising Spindle type. Sluice gates are as per IS 13349 Including all taxes, Freight, loading, unloading, fitting in position including Sluice gates are upward opening wall thimble mounted suitable for isolating the flow of sewer into out of the opening in the wall. It consists Gate frame, wall thimble, gate slide, shutter, seating/sealing faces .The gates will be provided with pads on sides, top and bottom to mount the wedges. The gate shall be designed in such a manner, so that it can be operated at 2 meter head. Gate frame & Shutter of CI Grade IS 210 FG 260, Head Stock assembly bolts & SS ASTM A276 Type316, Stem, Operating Nut SS ASTM A276 Type 316., Duly tested for tensile strength, Tested for over all dimensions as per approved GA drawing complete in all respect as per specification and direction of Engineer |
| 412 | Testing of above equipment at manufacturer works |
| 413 | Installation & Commissioning |
| 414 | Installation & commissioning of all screens and sluice gates complete. |
| 415 | Diesel Generating sets. |
| 416 | Supply of 82.5 KVA DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start ,Batteries, Fuel tank ( with Stand) & piping , control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments,accoustic enclosure,Noise level is less than 74 db(A) at a distance of 1 Mtrs, 0.8 pf(lag) 415 V, 3 Ø, 50 Hz capacity with Provision for PLC based AMF Panel fabricated from CRCA sheet steel 2 mm thick, powder coated finish, START & STOP commands, control relays, selector switches for Ammeter and Voltmeter, Ammeter & Voltmeter, Control & Power contactors, timers, electronic hooters, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for above DG set,as per technical specifications mentioned in tender documents & direction of EIC |
| 417 | Fuel tank |
| 418 | Batteries 24 volt 360AH dry and uncharged with battery leads and battery charger |
| 419 | Double earthing of DG set and all electrical equipment as per IS |
| 420 | Supplying and laying of Power cable of Suitable size of 415 Volt grade 3.5 core 95 sq.mm/suitable size AL armoured XLPE sheathed aluminium conductor from Transformer,DG set panel to LT panel (paid as per actual basis) |
| 421 | Supply and making end termination/joints of the above cable |
| 422 | Provision for 12/20mm thick electric resistance rubber sheets |
| 423 | INSTALLATION, COMMISSIONING AND TESTING |
| 424 | Installation, Testing of D.G. set, cable, AMF panel etc.at site |
| 425 | Commissioning of the above including supply of diesel and oil for trial |
| 426 | Testing of D.G set at manufacturer works |
| 427 | CE/UL certified local conrol room PLC/RTU with redundant CPU& power supply in IP 54 enclouser to communiate with gsm based modem unit with redundant cpu & power supply with analog and digital parameter and features as per spec mentioned in technical bid documents. |
| 428 | GSM/GPRS based wireless communication hardware for RTUs. Capable to transfer data from site to LCS with all accessories etc complete. |
| 429 | Intelligent energy meter |
| 430 | Smart Pressure transmitter |
| 431 | Auto phase reversal unit/Automatic transfer switch with inbuilt time delay and enclosure (Conforming to IEC 60947-1 & IEC 60947-6-1) of suitable for 4000Amp. rating |
| 432 | control Cabling and cabling of all equipments installed in PS |
| 433 | Security survelliance IP camera |
| 434 | Radar type level transmitter with RTU communication |
| 435 | Control Panel with IP 65 protection, industrial grade 24 V power supply and other required items |
| 436 | 3 phase Surge protector for all AC control supplies to all the equipment |
| 437 | 7\\" HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters |
| 438 | Installation, testing and commissioning |
| 439 | CE & BIS approved manufacturer's industrial grade 65 inch LCD monitor with latest configuration as per specification of size 65\\" |
| 440 | Desktop/PC i7 for LCS as per spec. mentioned in tender doc |
| 441 | CE/UL approved manufacturer's 3 KVA UPS with batteries as spec. mentioned for LCS and Computer as per requirement |
| 442 | Full development version of required TAGS SCADA software suitable for digital and analog input/output features with customization of software as per requirement as per spec. mentioned with unlimited digital and analog Input/Output features specified in detailed technical document with customization of software as requirement |
| 443 | CE & UL approved manufacturer's control room PLC with CPU & power supply at LCS in IP65 enclosure as per spec. mentioned |
| 444 | GSM based wireless communication system for PLC capable to transfer and gather data from remote sites to control stations, including all accessories complete |
| 445 | CE/UL approved manufacturer's Firewall for network protection |
| 446 | Lightning surge protector for ethernet communication protection |
| 447 | CE/UL approved manufacturer's industrial grade ethernet switch |
| 448 | Canon/HP 1018/equivalent Laser printer(1 Color & 1 Black & white) |
| 449 | Security Survelliance IP camera for LCS |
| 450 | Installation, testing and commissioning |
| 451 | Test and trial run including manpower,consumable items like HSD,Lube oil (paid as per actual consumption) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail