| 1 | SITC of wall mounted type microprocessor based AFD control panel | SITC of wall mounted type microprocessor based AFD control panel including 12V,7AH battery |
| 2 | Supplying, installation, testing and commissioning of 20W, 4 feet LED batten tube | Supplying, installation, testing and commissioning of 20W, 4 feet LED batten tube complete with all accessories |
| 3 | SF LED type solar street light fitting | SF LED type solar street light fitting on 25 mm size 1.2 m long medium class GI pipe |
| 4 | Replacing the faulty capacitor | Replacing the faulty capacitor of ceiling fan |
| 5 | Supplying and fixing of wall fan | Supplying and fixing of wall fan of min 400 mm sweep |
| 6 | Supplying and fixing 32 A DP switch fuse unit | Supplying and fixing 32 A DP switch fuse unit consisting of 1 No 16 A porcelain fuse unit |
| 7 | SF 16 32A rewirable type fuse unit | SF 16 32A rewirable type fuse unit with carrier and base |
| 8 | S F 16 32A neutral link | S F 16 32A neutral link with carrier |
| 9 | Wiring for light point ,fan point, exhaust fan point, call bell point Group A | Wiring for light point,fan point, exhaust fan point,call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface , recessed medium class PVC conduit Group A |
| 10 | Wiring for circuit, submain wiring 2 x 1.5 sq.mm 1 x 1.5 sq.mm earth wire | Wiring for circuit, submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable 2 x 1.5 sq.mm 1 x 1.5 sq.mm earth wire |
| 11 | Wiring for circuit, submain wiring 2 x 2.5 sq.mm 1 x 2.5 sq.mm earth wire | Wiring for circuit, submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable 2 x 2.5 sq.mm 1 x 2.5 sq.mm earth wire |
| 12 | Supplying and fixing following way , single pole and neutral , sheet steel, MCB distribution board 8 way, Double door | Supplying and fixing following way , single pole and neutral , sheet steel, MCB distribution board , 240V on surface,recess , complete with tinned copper bus bar , neutral bus bar , earth bar 8 way, Double door |
| 13 | Supply and fixing following 5A to 32A rating , 240V, 415V, 10kA, C curve miniature circuit breaker Single pole | Supply and fixing following 5A to 32A rating , 240V, 415V, 10kA , C curve miniature circuit breaker suitable for inductive load Single pole |
| 14 | Supplying and fixing single pole blanking plate | Supplying and fixing single pole blanking plate in the existing MCB DB |
| 15 | Supplying and fixing following rating, double pole, 240 volts, isolator 40 amps | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB - 40 amps |
| 16 | Supplying and fixing following rating , double pole single phase and neutral ,240 V ,residual current circuit breaker RCCB | Supplying and fixing following rating , double pole single phase and neutral ,240 V ,residual current circuit breaker RCCB having a sensitivity current 30 mA 25 A |
| 17 | Supplying and fixing call bell buzzer | Supplying and fixing call bell buzzer suitable for single phase supply |
| 18 | Supplying and fixing PVC batten angle holder | Supplying and fixing PVC batten angle holder including connections |
| 19 | Supply and fixing following modular switch socket 5 6 A switch | Supply and fixing following modular switch socket on the existing modular plate and switch box 5 6 A switch |
| 20 | Supply and fixing following modular switch socket 3 pin 5 6 A socket outlet | Supply and fixing following modular switch socket on the existing modular plate and switch box 3 pin 5 6 A socket outlet |
| 21 | Supply and fixing following modular switch socket 15 16 amp switch | Supply and fixing following modular switch socket on the existing modular plate and switch box 15 16 amp switch |
| 22 | Supply and fixing following modular switch socket 6 pin 15 16 amp socket outlet | Supply and fixing following modular switch socket on the existing modular plate and switch box 6 pin 15 16 amp socket outlet |
| 23 | Supplying and fixing following size modules, GI box 4 Module 125mmX75mm | Supplying and fixing following size modules, GI box along with modular base & cover plate 4 Module 125mmX75mm |
| 24 | Supplying and fixing stepped type electronic fan regulator | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box |
| 25 | Providing and fixing 4.00 mm dia copper wire on surface | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing |