|
| 1 | Excavation in trenches n. exc 1.5 m wide for foundation, laying of pipes, drain, trenches etc. getting out in soft/ loose soil by manually not exceeding 1.50 metre deep and getting out complete, all as specified and as directed. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified and as directed. |
| 3 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified and as directed. |
| 4 | Removing excavated spoil to a distance not exceeding 500 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and as directed. |
| 5 | Removing old torn out Retro- reflective self adhesive tape and sticker on existing link sign boards including cleaning and refixing new Retro reflective tape and stickers (by using 3M HIP high intensity grade prismatic reflective) on the existing sign boards complete all as directed by Engineer -in- Charge. |
| 6 | M&L for PCC type B-0 (1:2:4), using 12.5 mm graded crushed stone aggregates as in coping, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 7 | M&L for PCC type D-2 (1:4:8), using 40 mm graded crushed stone aggregates as in filling & mass concrete, sub base etc. complete all as specified and as directed. |
| 8 | M&L for PCC type C-2 (1:3:6), using 40 mm graded crushed stone aggregates as in filling & mass concrete, sub base etc. complete all as specified and as directed. |
| 9 | M&L for PCC type B-2 (1:2:4), using 40 mm graded crushed stone aggregates as in surface channels and drain complete all as specified and as directed. |
| 10 | M&L for PCC type B-1 (1:2:4), using 20 mm graded crushed stone aggregates as in kerb or mud stops, rounded or chamfered on edges complete all as specified. |
| 11 | M&L for Precast RCC type B-1 (1:2:4), using 20 mm graded crushed stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar (1:4), complete all as specified and as directed. |
| 12 | M&L for Brick work using bricks as specified in PS , straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified and as directed. |
| 13 | M&L for Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:4), complete all as specified and as directed.NOTE: Old bricks obtained after dismantling of brick work will be reused after cleaning etc under this item. |
| 14 | M&L for Brick work using bricks as specified in PS-II clause 5.1 straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:3), complete all as specified and as directed. |
| 15 | M&L for Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4), complete all as specified and as directed.NOTE: Old bricks obtained after dismantling of brick work will be reused after cleaning etc under this item. |
| 16 | Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 17 | M&L for 75 mm thick, cement concrete type D-2, (1:4:8) using 40 mm graded crushed stone aggregate, finished even & rough, as in sub floors, complete all as specified and as directed.. |
| 18 | M&L for 100 mm thick, cement concrete type B-1, (1:2:4) using 20 mm graded crushed stone aggregate, finished even & smooth without using extra cement, as in flooring, complete all as specified and as directed. |
| 19 | M&L for Factory made, Machine pressed precast concrete interlocking paver block any shape with grey cement and no pigment and size approved by GE, ISI marked (IS:15658-2006) of 60 mm thick, M-35 grade (Medium Traffic), over & including 25 mm thick (consolidated thickness) fine sand cushioning complete all as specified and as directed. |
| 20 | M&L for Factory made, Machine pressed precast concrete interlocking paver block any shape with grey cement and no pigment and size approved by GE, ISI marked (IS:15658-2006) of 80 mm thick, M-40 grade (Medium Traffic), over & including 25 mm thick (consolidated thickness) fine sand cushioning complete all as specified and as directed. |
| 21 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), complete all as specified and as directed. |
| 22 | Dismantling of sign boards any size made with MS or aluminium tubes/squares framework / CPVC Pipes including digging embedded portion and demoliton of concrete and its removal upto 2 kilometre complete. |
| 23 | M&L for HIP (Reflective) Tape and stickers of various size and shape on different types of sign boards using 3M TM High intensity grade Prismatic Reflective sheeting 3930 to 3937 series of approved colour fixing with pressure sensitive adhesive for unique construction providing high levels of retro reflectivity for multiple traffic situations providing long term reflectivity and durability fixed over ACP Sheet etc complete all as directed by Engineer -in- Charge. |
| 24 | S&F CPVC Pipe of 50mm bore including fixing with Polycarbonate sheet panel / ACP Sheet and Aluminium sections/ angles of various sizes as in support / stay for sign boards including bends, tee elbow etc complete all as specified and directed. |
| 25 | M&L for 4mm thick Aluminium composite panel (ACP sheet) of approved colour, suitable for pasting stickers / 3M HIP Reflective tape, cut to suitable size, fixed with CPVC pipe as in sign boards complete all as directed by Engineer-in-Charge. |
| 26 | Re-fixing of existing sign boards of any type and size in PCC 1:2:4 type B-1 using 20mm graded stone aggregate Blocks of size 300x300x450mm in the Air field area including necessary excavation, earth work and after necessary repairing / raising height as per requirement complete all as specified. Note : CPVC Pipe for raising height, Retro-Reflective tape will be measured and paid separately. |
| 27 | M&L for taking down polycarbonate sheet of existing LED Sign board and re-fixing new polycarbonate sheet panel 5mm thick, provided with AV 450 series colour vinyls stickers of various size and shape for sign boards as writing numerical, alphabets, border and arrow etc on one side for various types of LED sign boards of any size complete all as directed by Engineer -in- Charge. Please Enable Macros to View BoQ information |
| 28 | M&L for taking down polycarbonate sheet of existing LED Sign board and re-fixing new polycarbonate sheet panel 5mm thick, provided with AV 450 series colour vinyls stickers of various size and shape for sign boards as writing numerical, alphabets, border and arrow etc on one side for various types of LED sign boards of any size complete all as directed by Engineer -in- Charge. Please Enable Macros to View BoQ information |