| 1 | Demolition of wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets and metal frame work complete all as specified and directed. |
| 2 | S&F Solid PVC wall lining consisting of 5mm thick any colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame, PVC strip etc fixing as wall panelling up to ceiling level all included as per specification SSR part-I, complete all as specified. |
| 3 | S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on wall to make PVC frame, complete all as specified and directed. |
| 4 | S&F powder coated GI snap grid frame work of size 605mm x 605mm for false ceiling complete with accessories all as specified and shown in MES SSR Part-II, complete all as specified and directed. |
| 5 | S&F Gl frame work Plain or Bi-level for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 6 | S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 7 | M&L for Exposed metal frame ceiling with 8 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed. |
| 8 | M&L for 8 mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having Phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish(Frame work for ceiling shall be measured and paid separately) ,including two oats of interior acrylic distemper/oil bound distemper over a coat of putty filling on gap ceiling surfaces complete all as specified and directed. |
| 9 | M&L for Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions including two oats of interior acrylic distemper/oil bound distemper over a coat of putty filling on gap ceiling surfaces complete all as specified and directed. |
| 10 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 11 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed. |
| 12 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet (Except sheeting any thickness) as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed. |
| 13 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 14 | Excavating in post holes in soft /loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 15 | M & L for Cement concrete 1:3:6 type C2 using 40 mm graded stone aggregates in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 16 | M&L for Two coats of synthetic enamel paint over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, over a coat of red oxide primer including preparation of new surfaces , for height not exceeding 8.50 metre complete all as specified and directed. |
| 17 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 18 | S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts. posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 19 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed. |
| 20 | Demolition of cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) and removing demolished material from site to a distance exceeding 1.50 Km and not exceeding 5 Km and depositing where directed by Engineer-in-Charge. |
| 21 | M & L for 100mm thick plain cement concrete 1:4:8 type D2, using 40mm graded stone aggregate as in sub base complete all as specified and directed. |
| 22 | Fixing only cement concrete paver block of any thickness as in footpath, parks, lawns, drive ways or light traffic parking etc. obtained from dismantled tiles or where floor is sunk , including 25 mm thick compacted bed of coarse sand , compacting complete all as specified and directed. |
| 23 | M&L for providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved design & pattern as in footpath , parks , lawns, drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling joints with sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 24 | M&L for providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved design & pattern as in footpath , parks , lawns, drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling joints with sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 25 | Material and labour for cement concrete 1:2:4 Type B-1 using 20 mm graded stone aggregate as in copings, weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | Supply & application of heavy duty Self levelling slip resistance Epoxy Flooring system to an avg 3 mm thickness, including Surface Preparation, application of one coat of Pidilite Epoxy Primer Pidipoxy EP (or any equivalent), followed by topping the surface with Heavy duty Chemical resistant Epoxy Resin Topping with Dr. Fixit Pidipoxy ESL2000 (or any equivalent) in desired colour , custom design and Gloss as approved by Engineer in charge complete all as specified and directed. |
| 27 | S& F Superior Quality PVC UV marble Sheet , 2.50-3.00 mm thick with High Gloss Surface as in wall cladding including all necessary fixture and fitting like jointer and corner etc , design as approved by Engineer in charge complete all as specified and directed . |
| 28 | S&F WPC Wall louvers Panel, Each panel having 220 mm width and 25 to 30 mm thick and minimum 2900 mm height and minimum 4 nos of louvers , including all fixture and fittings etc , design and colour as approved by Engineer in charge complete all as specified and directed. |
| 29 | Dismantling structural steel works or of any description / type including doors, gates etc complete all as specified. |
| 30 | Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information |