| 1 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/ sqm and coarse sand @ 1.289 kg/ sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. D.S.R No- 22.6 |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 25 mm and up to 40 mm DS.R.No-15.23.2 |
| 3 | Cement concrete flooring 1:2:4(1 cement:2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry but excluding cost of nosing of steps etc.complete. 40 mm thick with 20 mm nominal size stone aggregates.D.S.R No-11.3.1 |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. D.S.R No- 15.56 |
| 5 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) D.S.R No- 13.4.2 |
| 6 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.D.S.R 13.80 |
| 7 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below DSR 15.12.1 |
| 8 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for hold fasts embedding hold fasts in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 ( 1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). painting two coats of approved wood preservation to sides of chowkhats and making good the damages to wall and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-charge. Door chowkhats D.S.R. No- 14.2.1 |
| 9 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for hold fasts embedding hold fasts in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 ( 1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). painting two coats of approved wood preservation to sides of chowkhats and making good the damages to wall and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-charge. Window chowkhats D.S.R. No- 14.2.2 |
| 10 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix) DSR 15.2.1 |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR No- 5.1.2 |
| 12 | Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. mild steel and medium tensile steel bars DSR No.5.22.1 |
| 13 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. D.S.RNo-14.85 |
| 14 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides DSR 10.29.2 |
| 15 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes DSR 10.30.2 |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary Screws D.S.R No- 9.21.2 |
| 17 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete D.S.R. 13.91 |
| 18 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) DSR 13.81.1 |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work DSR 13.99.1 |
| 20 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes 110 mm diameter D.S.R.No-12.41.2 Please Enable Macros to View BoQ information |