| 1 | Civil &Sanitray |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 3 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 60 cm girth upto and including 120 cm girth. |
| 4 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, and disposal of excavated earth: outside All kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 6 | Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 10 cm, for all leads and lifts all complete as per direction of Engineer-in-charge. |
| 7 | Hire charges of Pumpset of capacity 4000 litres/hour |
| 8 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centering and shuttering. with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 9 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade forreinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as perdirection of the Engineer- in - charge. Note: - Cement content considered in this item is @330 kg/ cum. |
| 10 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centering and shuttering. With 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for:5.9.21 Lintel, beams, plinth beams, girders, bressumers and cantilevers with waterproofing ply 12 mm thick |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs (excluding landings) except spiral staircases. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.20 Suspended floors, roofs, landings, balconies and access platform with waterproofing ply 12 mm thick |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete: Thermo-Mechanically Treated bars of grade Fe-550D or more. |
| 16 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 17 | Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7 kg per square meter on damp proof courses after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 18 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) Flemish Bond upto floor five level |
| 19 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 20 | Brick work in plain arches in superstructure above plinth level and upto floor V level including centering, shuttering and curing complete for span upto 6 meters with commonburnt clay (non-modular) bricks of class designation 7.5 in cement mortar 1:3 ( 1 cement : 3 coarse sand ) |
| 21 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 22 | Half brick masonry with common burnt clay (non-modular) bricks of class designation7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 23 | Providing wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood |
| 24 | Providing and fixing paneled or paneled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). First class kail wood 35 mm |
| 25 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. First Class kail wood |
| 26 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 5.0 mm thick glass pane (weighing not less than 12.50 kg/sqm) |
| 27 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia wire and 1.4 mm wide aperture with matching wood beading |
| 28 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 29 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 30 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 31 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm |
| 32 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 33 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 34 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets 25 mm dia( heavy type) |
| 35 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 36 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete 100x58x1.90 mm |
| 37 | Supplying and stacking and spreading at site, Good Earth including carriage |
| 38 | Providing and fixing Aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Polyester powder coated Aluminum (minimum thickness of polyester powder coated 50 microns) |
| 39 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in Aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on bothsides. |
| 40 | Providing and fixing glazing in Aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge. (Cost of Aluminum snap beading shall be paid in basic item.)With float glass panes of 8 mm thickness (weight not less than20.0 kg / sqm) |
| 41 | Filling the gap in between Aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5mm width |
| 42 | Providing and fixing Aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge. Anodized (AC 15)Aluminum tubular handle bar |
| 43 | Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for Almunium doors including necessary cutting and making good etc. complete. |
| 44 | Providing and fixing Aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm |
| 45 | Providing and fixing Aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 46 | Providing and fixing Aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Single rubber stopper |
| 47 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISImarked, with six levers and a pair of anodized (anodic coating not less thangrade AC 10 as per IS : 1868) Aluminum lever handles of approved quality withnecessary screws etc. complete. |
| 48 | Providing and fixing magnetic catcher of approved quality in cupboard/wardrobe shutters including fixing with necessary screws etc. complete. Triple strip (Vertical type) |
| 49 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 50 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished seamless type tubes. |
| 51 | Providing and fixing M.S. fan clamp of 16mm dia M.S. bar, bent to shape with hooked ends in R.C.C, slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 52 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 53 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) |
| 54 | Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent. |
| 55 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 56 | Providing and fixing precoated galvanized steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 57 | Providing and fixing plained eaves boarding. 250x32 mm (nominal size ) |
| 58 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws 2nd class kail wood |
| 59 | Supplying and stacking at site Graded crushed stone aggregate of size 90 mm to 45 mm |
| 60 | Supplying and stacking at site Graded crushed stone aggregate of size 63 mm to 45 mm |
| 61 | Supplying and stacking at site Graded crushed stone aggregate of size13.2 mm nominal size |
| 62 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, ramming manually with 10 kg rammer, including watering and compacting to the required density. |
| 63 | Providing and applying tack coat using hot straight run bitumen of grade – VG-10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. On W.B.M. @ 0.75 Kg/sqm. |
| 64 | Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade including required key aggregate as specified, spreading coarse aggregate with the help of self propelled/ tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy. 16.44.1 For 50 mm compacted thickness using coarse aggregate of size 50-20mm graded @ 0.60 cum per 10 sqm key aggregate of size 12.5 mm graded @ 0.15 cum per 10 sqm. With paving asphalt grade VG-10 @ 50 kg/10sqm |
| 65 | Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG-30 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road all complete |
| 66 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colou r& pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 16.93.1 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 67 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 68 | Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 ( 1 cement : 1 fine sand) including testing of joints etc. complete: 20.28.1 100 mm dia |
| 69 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:18.2.1 W.C. pan with ISI marked white solid plastic seat and lid. |
| 70 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 71 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 72 | Providing and fixing white vitreous china extended wall mounting watercloset of size 780x370x690 mm of approved shape including providingand fixing white vitreous china cistern with dual flush fitting, of flushingcapacity 3 liter/6 liter (adjustable to 4 liter/8 liters), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete. |
| 73 | Providing and fixing P.V.C low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete: 10 liter capacity -White |
| 74 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 75 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia |
| 76 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 77 | Providing and fixing toilet paper holder C.P. brass |
| 78 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in-charge. 19.2.2 Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. PN-16 pipe, 16mm OD(SDR-7.4) |
| 79 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in-charge. PN-16 pipe , 20mm OD(SDR-7.4) |
| 80 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in-charge. PN-16 pipe , 25mm OD(SDR-7.4) |
| 81 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in-charge. PN-16 pipe , 32mm OD(SDR-7.4) |
| 82 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in-charge. 19.2.3 External work including trenching, refilling etc. PN-16 pipe, 40mm OD (SDR-7.4) |
| 83 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc. 19.2.3.6 PN-10 pipe , 50mm OD (SDR-11) |
| 84 | Providing and fixing 20mm PPR Unions |
| 85 | Providing and fixing 25mm PPR Unions |
| 86 | Providing and fixing 32mm PPR Unions |
| 87 | Providing and fixing 40mm PPR Unions |
| 88 | Providing and fixing 50mm PPR Unions |
| 89 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 90 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 91 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 92 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) ofstandard design and of approved make conforming to IS : 8931 |
| 93 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS :8931 |
| 94 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 95 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 96 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete 600 mm dia. R.C.C. pipe |
| 97 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.2Inside size 90x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 98 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 99 | Providing and fixing on wall 50 LTRS Electric Geyser with ABS Body. Makes:- Bajaj/ Crompton/ Jaquar/Hindware |
| 100 | P/F 8 mm thick MDF panelling in walls including frame work with 12mm thick ply (waterproof), beading all complete as per directions of Engineer Incharge |
| 101 | Supllying of 8mm tougned glass table top of required size (black) including making edges smooth all complete (Rectangular shape) |
| 102 | Supllying of 12mm tougned glass table top of required size including making edges smooth all complete (any shape shape). |
| 103 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 104 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Flexible pipe 18.28.2.1 32 mm dia |
| 105 | Providing and fixing soil, waste and vent pipes : 75 mm diameter. PVC |
| 106 | Providing and fixing soil, waste and vent pipes 100 mm dia. PVC |
| 107 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100 mm dia. 75 mm dia.PVC |
| 108 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100 mm dia.18.38.1 100 mm dia. PVC |
| 109 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/Cast Iron (spun) pipe PVC pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), including cost of cutting holes and making good the walls etc: For 75 mm dia. Pipe |
| 110 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/Cast Iron (spun) pipe, PVC pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), including cost of cutting holes and making good the walls etc For 100 mm dia. Pipe |
| 111 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. |
| 112 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 113 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms |
| 114 | Providing and fixing PTMT grating of approved quality and colour.Circular type 100 mm nominal dia. |
| 115 | Carriage by mechanical means for crushed aggregate : Lead= 15 km |
| 116 | Carriage by mechanical means for fine aggregate : Lead= 50 km |
| 117 | Carriage by mechanical means for cement : Lead= 5 km |
| 118 | Carriage by mechanical means for TOR/ Structural Steel/ GI Sheets: Lead = 5km |
| 119 | Carriage by mechanical means for bricks : Lead= 30 km |
| 120 | Carriage by mechanical means for good earth : Lead= 30 km |
| 121 | Carriage by mechanical means for wood : Lead= 10 km |
| 122 | Carriage by mechanical means for SW pipes : Lead= 10 km |
| 123 | Carriage by mechanical means for stones : Lead= 20 km Please Enable Macros to View BoQ information |