|
| 1 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material |
| 2 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). 600 x 600 mm |
| 3 | Providing and laying Anti skid Ceramic floor tiles of size 300 x 300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 4 | Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 5 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect |
| 6 | Providing and fixing in position CP Brass single lever surgical mixer with swinging spout approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 7 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects |
| 8 | Providing and fixing in position 15mm C.P. Pillar cock foam flow of approved make (to the approval of Engineer-in-charge) |
| 9 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 10 | Providing & Fixing in postion stop cock /Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 11 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing |
| 12 | Single Socket Type B |
| 13 | a) 160mm o/d SWR UPVC pipe lines laidcomplete |
| 14 | Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. |
| 15 | With 100mm x 75mm i/d Floor Trap(weighing 4.0 Kg) |
| 16 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 17 | For 110mm o/d pipes |
| 18 | Elbow 90 Degree (All side socketed) |
| 19 | For 90mm o/d pipes |
| 20 | Elbow 90 degree (all side socket) |
| 21 | Coupler |
| 22 | Providing and fixing C.P. brass Urinal Spreader Ocular-Regular complete with fittings for urinals complete. |
| 23 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform,vanity counter and similar location in marble/granite/ stone work, including necessary holesfor pillar taps etc. including moulding, rubbingand polishing of cut edges etc. complete. |
| 24 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite(size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of theEngineer-in-charge) with or without 10 ltr.chinaware matching flushing cistern and seatcover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 25 | Providing and fixing jet spray with 2'-6\\" long With C.P. Brass nut |
| 26 | Providing & Fixing in postion 15 mm i/d bibcock of approved make (to the approval of Engineer-in-charge )complete in all respect |
| 27 | 15mm i/d |
| 28 | Providing & Fixing in postion stop cock /Angle valve of approved make (to theapproval of Engineer-in-charge ) complete in all respect. |
| 29 | C.P.brass 15mm Angle valve without flange |
| 30 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 31 | PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut |
| 32 | Providing and fixing in position Vitreous Chinaware white urinal withconcealed or inbuilt P-trap (size 310x370x640 mm) with builtin water seal, outlet to wall and water inletfrom back of approved make (to the approvalof Engineer-in-charge) complete in all respect. |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:- Up to 15.00 Mtr. Span (50mmx25mm) |
| 34 | Providing and fixing in position automatic brass Ball Cock in tanks (A) Brass Ball Cock with rod and Plastic Ball of 25mm i/d |
| 35 | SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mmdia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches withindicator etc. and covered with Frame Plateetc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junctionBoxes (Four way 1½\\" deep for walls), bonding to earth with PVC insulated copperconductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of abovematerial and painting as required: |
| 36 | Wiring 6Amp. wall socket point |
| 37 | Wiring 16/20Amp. power plug control point |
| 38 | Providing & Fixing of 40mm Wall PUF(polyurethane foam ) insulated thick Panel with Prepainted Galvanised Ironsheet both sides in 40±2 Kg Density The PU panel shall be CFC( Chlorofluorocarbon)free and Zero Ozone depleting panel using N Pantane blowing agent & made out of continuous line running on uninterrupted power supply. Panel shall have pre coated GI sheet on both side of Polyurethane Foam confirming to IS 12436:1988. The pre coated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS : 277 : 1992, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The panels shall be vertically joined together by tongue and groove joints. The PU Foam shall be self-extinguishing, fire retardant type having minimum density of 40 Kg/Cu.mt (+, -2 Kgs). Surface of steel sheets has plain & light grooves to enhance their strength & aesthetic appearance complete with corner panels as required. |
| 39 | Providing & Fixing of 30 mm Roof PUF(polyurethane foam ) insulated thick Panel with Prepainted Galvanised Ironsheet both sides in 40±2 Kg Density The PU panel shall be CFC( Chlorofluorocarbon)free and Zero Ozone depleting panel using N Pantane blowing agent & made out of continuous line running on uninterrupted power supply. Panel shall have pre coated GI sheet of 0.5mm thickness on both side of Polyurethane Foam confirming to IS 12436:1988. The pre coated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per IS : 277 : 1992, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The panels shall be vertically joined together by tongue and groove joints. The PU Foam shall be self-extinguishing, fire retardant type having minimum density of 40 Kg/Cu.mt (+, -2 Kgs).The centre to centre pitch of crest profile on top sheet should be between 250mm- 270mm to ensure proper water flow. The roof shall have a projection of minimum 300mm on all sides. Metallic facing sheets are plain with intermediate small ribbed finish on inner skin & Hi Rib sheet as outer skin.(Make: Kingspan Jindal, Sintex, Mectecno,LLoyd insulation) |
| 40 | ROOFTOP |
| 41 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension on higher side shall be accepted but no extra payment on this account shall be made. |
| 42 | Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm) |
| 43 | WINDOW |
| 44 | VENTILATION WINDOW |
| 45 | COUNTER WINDOW |
| 46 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 47 | UPVC FLUSH DOOR |
| 48 | Flashing in PPGL 0.50 for U-channel, inner.outer, end cap,inner corner,Outer corner,Gutter, Gable trim, Inner Ridge, outer Ridge |
| 49 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 50 | (i) Triple Layer Tanks (200ltr) |
| 51 | Office Table |
| 52 | Office Chairs |
| 53 | A.C 1 ton |
| 54 | LED LIGHT |
| 55 | Wall Mounted moving Fan |
| 56 | luminous Invertor with battery 200watt |
| 57 | Vehicle (M&M passenger car SUV Scorpio N Z4 D MT 2WD 7STR BS6.2) LED LIGHT Please Enable Macros to View BoQ information |