| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth not exceeding 1.5m and getting out in Soft / Loose soil complete all as specified and as directed. |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth exceeding 1.5m deep and not exceeding 3.0m deep and getting out in Soft / Loose soil complete all as specified and as directed. |
| 3 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth exceeding 3.0m deep and not exceeding 4.5m deep and getting out in Soft / Loose soil complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 5 | Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 6 | M & L for PCC 1:4:8, Type D–2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed. |
| 7 | M & L for Pre-Construction Anti-Termite Treatment for treating the Backfill in Contact with Foundation @ 7.5 Litres of Emulsion per Square Metre of Vertical Surface [Area of the sub structure in contact with backfill to be measured] complete all as specified and as directed. |
| 8 | M & L for Pre-Construction Anti-Termite Treatment for treating the Top Surface of Filled Earth @ 5 Litres of Emulsion per Square Metre of surface complete all as specified and as directed. |
| 9 | M & L for Pre-Construction Anti-Termite Treatment for treating the Soil Under Plinth Pprotection @ 5 Litres of Emulsion per Square Metre of surface area complete all as specified and as directed. |
| 10 | M & L for Pre-Construction Anti-Termite Treatment for treating the Soil along with External Perimeter of the Building by applying Emulsion@ 2.25 Litres per Running Metre of the perimeter wall complete all as specified and as directed. |
| 11 | M & L for RCC M–30 Design Mix, using 20mm graded stone aggregate as in Foundations including Pile Caps, Rafts, Footings, Foundation Beams, Plinth Beams, Bases for Columns, Fillings, Mass Concrete, Basement Slabs etc. etc. complete all as specified and as directed. |
| 12 | M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Columns, Pillars, Piers, Posts and struts etc. complete all as specified and as directed. |
| 13 | M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Beams, Cantilevers, Bressummers, Lintels over 1.5m Span etc. complete all as specified and as directed. |
| 14 | M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Slabs supported on Walls, Beams, Columns, in Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs and in Shelves and the like and the like complete all as specified and as directed. |
| 15 | M & L for RCC M-30 Grade, Design Mix, using 20mm graded stone aggregate as in Chajjas, Facias & Fins etc. complete all as specified and as directed. |
| 16 | Use and removal of Steel Formwork to Sides of concrete Foundations, Pile Caps, Footings, Bases of Columns, Raft and Raft Beams, Sides and Soffits [if any] of Foundation and Plinth Beams and similar work, Vertical or to Batter for Rough Finished surfaces complete all as specified and as directed. |
| 17 | Use and removal of Steel Formwork to Sides of Pillars, Posts, Struts, Piers, Columns and Stanchions of any Shape / Cross Section for Fair Finished surfaces of concrete complete all as specified and as directed. |
| 18 | Use and removal of Steel Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves including Supports, Overhangs, etc, Splays between Floors and Beams and similar works for Fair Finished surfaces of concrete complete all as specified and as directed. |
| 19 | Use and removal of Steel Formwork to Soffits of Suspended Slabs such as Roof Slabs, Floor Slabs, Landings and similar work not exceeding 200mm thick [Horizontal or Sloping] for Fair Finished surfaces complete all as specified and directed. |
| 20 | Use and removal of Steel Formwork to Chullah Hoods, Chajjas, Troughs and similar items including Edges and similar works for Fair Finished surfaces of concrete complete all as specified and as directed. |
| 21 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 22 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 23 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 24 | M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed. |
| 25 | Spreading, levelling and well ramming including watering as required with excavated soils in layers not exceeding 25cm thick in Floors complete all as specified and as directed. |
| 26 | M & L for Hardcore of Gauge not exceeding 63 mm of Broken Stones or Boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface in broken boulder complete all as specified and as directed. |
| 27 | M & L for 75 mm thick, PCC 1:4:8, Type D-2, using 40mm graded aggregate as in Sub base for flooring complete all as specified and as directed. |
| 28 | M & L for 25 mm thick, PCC 1:2:4, Type B-0 using 12.5mm graded aggregate as in Sub base for flooring complete all as specified and as directed. |
| 29 | M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 30 | M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE. |
| 31 | M & L for rendering on fair faces of brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 32 | M & L for rendering 5mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately. |
| 33 | M & L for Brushing neat Cement Slurry with 3.0 KG of cement per Sq.m area complete all as specified and as directed. |
| 34 | M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 35 | Supply only Integral Water Proofing Compound [ISI marked] of approved make complete all as specified and as directed. |
| 36 | M & L for preparing newly plastered wall surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over One Coat of Alkali Resistant Primer on walls complete all as specified and as directed. |
| 37 | M & L for preparing newly plastered wall surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls complete all as specified and as directed. |
| 38 | M & L for preparing newly plastered Ceiling Surfaces and applying Three Coats of White Washing complete all as specified and as directed. |
| 39 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of Oil Based Bituminous Primer conforming to IS – 3384 [Latest] @ 0.3 Litre / Sq.m, laying APP Modified [Polyester Reinforced] Membrane of 3mm thick weighing not less than 3.8 KG / Sq.m confirming to IS – 16532 [2017], by torch application with side overlap of 100mm & end overlap of 150mm & tucked into the chases on vertical surfaces by thermo fusion and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately. |
| 40 | M & L for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc. surface finished even and smooth with out using extra cement complete all as specified and as directed. |
| 41 | S & F Solid PVC Door Frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per Specification & Drawing shown on Serial Page No. 160 of MES Schedule Part - II complete all as specified and as directed. |
| 42 | S & F Factory made Solid Panel PVC Door Shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC \\"C\\" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supplying & fixing in frame at site as per specification & drawing shown on Serial Page No. 157 of MES Schedule Part - II complete all as specified and as directed. |
| 43 | S & F Factory made UPVC Fixed Window / Ventilator, White Colour, of area not exceeding 1.0 Sq.m each, made of extruded profiles with wall thickness of 2.3mm±0.2mm, Window profile with hollow section with multi chamber, Frame of size 60mm X 58mm, T Profile [One vertical length in between two shutters] of size 60mmx 74mm, Glazing Bead of size 35mm X 20mm will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM Gasket, 1.2mm±0.2mm thick Galvanized Steel Frame of size 28mmx 21.5mm, T Profile of size 27mm x 17mm to be inserted in required profile, frame shall be fixed to wall with 8mm X 100mm long fasteners, 5mm thick glazing with selected quality Frosted Glass / Sheet Glass complete all as specified and as per Manufacturer instructions. Note: The unit rate quoted by contractor includes cost of Frosted Glass / Sheet Glass includes all other connected accessories. Net opening will be measured for payment purpose. |
| 44 | S & F 100 mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed. |
| 45 | S & F Aluminium anodised Handle, Cast Type, of size 150 mm complete all as specified and as directed. |
| 46 | S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed. |
| 47 | S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 48 | S & F Mild Steel work confirming to Fe - 290, Grade E-165 as in Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes, including Bolts, if required, Hooks [Stay], heavy, for Large Gates, Hook and Pintle Hinges, large Hasps and Staples, Chains, hand made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles complete all as specified and as directed. |
| 49 | M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 6mm dia bars at every fourth course of brick work complete all as specified and as directed. |
| 50 | M & L for Glazed Polish finished coloured Designer Chequered Cement Concrete Tiles of thickness 23 to 25mm, made with M-25 Grade Precast Cement Concrete, Hydraulically pressed of size not less than 300 X 300 mm, of approved Shape, Colour, Design and Pattern, set, jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. |
| 51 | M & L for providing Cement Concrete, Type B1, 1:2:4 using 20mm Graded Aggregate as in Cast in Situ in Lintels up to 1.5m Span, Cills, Steps, Seismic and Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets and Railings up to 60 cm in Height, Copings, Kneelers, Apex Stones, Bed Plates including Weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed. |
| 52 | S & F 20mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing complete all as specified and as directed. |
| 53 | S & F 25mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing complete all as specified and as directed. |
| 54 | S & F Rotational Moulded Polythene [HDPE] Water Tanks, Double Layered, ISI Marked, Cylindrical & Vertical Type 500 Liters Capacity hoisted and fixed in position including provision of 32mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete complete all as specified and as directed. |
| 55 | S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 Mpa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed. |
| 56 | S & F Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-047KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 57 | S & F Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-041KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 58 | S & F Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered \\"Hot\\" or \\"Cold\\" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as per Jaquar Catalogue No. CON-011KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 59 | S & F Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as per Jaquar Catalogue No. CON-083KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 60 | S & F Health Faucet, Chromium Plated ABS Body with 1.20 m long flexible tube, wall hook, non return valve complete as per Jaquar Catalogue No. ALD-577 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified and as directed. |
| 61 | S & F Stainless Steel, Tubular Towel Rail, D Type, 600 mm long between flanges complete all as per Jaquar Catalogue No. ACN-1111SM or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 62 | S & F 600 mm X 450 mm Fancy Type Bevelled Edge Mirror of selected quality glass, 5 mm thick and fitted with SS Clamps for fixing to Wall surface etc. complete all as specified and as directed. |
| 63 | S & F Stainless Steel, Soap Dish, Fancy Type complete all as per Jaquar Catalogue No. ACN-1131N or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 64 | S & F Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed. |
| 65 | S & F Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified. |
| 66 | S & F Vitreous China Wash Down Water Closet [Pedestal pattern], White, including Plastic Water Closet Seat, Back, Closed Pattern, White with Flat Bottom and Cover and Mild Steel Chromium Plated or Aluminium Hinging Device and \\"P\\" or \\"S\\" Trap and including 10 Litres capacity, PVC Valve less, Syphonic action type, Low Level Flushing Ccistern, White, with Inlet Ball Valve, Float, Handle, Flush Pipe of Polyethylene of Low or High Density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm Long with PTMT Check Nut and Union etc. including Brackets and Connections to Pipe and Flush Pipe mplete all as specified and as directed. |
| 67 | S & F Vitreous China Urinal, Half Stall Type, Flat Back or Corner Wall Type, White, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long Brass Screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, grating and union for discharge pipe, CP screws etc complete all as specified and as directed. |
| 68 | S & F Vitreous China Urinal Partition of size 310X700 mm, White Colour complete all as specified and as directed. |
| 69 | S & F PTMT Grating Doom, 125 mm dia [Minimum weight 40 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and directed. |
| 70 | S & F Glass Shelf with Bracket, 550mm Long complete as per Jaquar Catalogue No. AQN-7771 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified. |
| 71 | S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed. |
| 72 | S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed. |
| 73 | S & F 50mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed. |
| 74 | S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed. |
| 75 | S & F 75 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed. |
| 76 | S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed. |
| 77 | S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed. |
| 78 | S & F 100mm Diameter Stainless Steel Anti Cockroach Floor Trap with SS Grating including jointing to Nahani Trap, fixed in PCC 1:2:4, Type B0 using 10mm graded stone aggregate complete all as specified and as directed. |
| 79 | M & L for PVC [SWR] Floor Trap with 75mm dia outlet, plain with grating including jointing to waste pipe with solvent cement complete all as specified and as directed. |
| 80 | S & F 150mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 81 | M & L for concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed. |
| 82 | M & L for Providing Precast Cement Concrete Solid Block Masonry with Solid Blocks exceeding 100mm width of PCC 1:3:6, Type – C1 using 20mm graded stone aggregate set in Cement Mortar 1:6 complete all as specified and as directed. |
| 83 | M & L for rendering on fair faces of brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately. |
| 84 | M & L for providing Precast RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Landings, Cover Slabs [for Manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in Cement Mortar 1:6 complete all as specified and as directed. |
| 85 | M & L for Loose Filling with broken Bricks of gauge 80 to 150mm in soakage pits etc. complete all as specified and directed. |
| 86 | M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified and as directed. |
| 87 | All as per Serial Item No. 86 above but for One 3 pin Socket Outlet 5 Amps on the Same Board with other switches complete all as specified and as directed. |
| 88 | All as per Serial Item No. 86 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor. |
| 89 | M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. |
| 90 | S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed. |
| 91 | S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed. |
| 92 | S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed. |
| 93 | S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed. |
| 94 | S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed. |
| 95 | S & F MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. |
| 96 | S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. |
| 97 | S & F MCB, DP, 40 to 63 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. |
| 98 | S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700K of cool white, with extruded Aluminium housing and robust construction with necessary acrylic diffuser & Integrated Electronic Driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 99 | S & F Exhaust Fan, 250mm Sweep, 1400 RPM, PVC Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in existing opening and making good the disturbed surface to match with existing and complete all as specified and as directed. |
| 100 | Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 2 Core, 10 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed. |
| 101 | M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment. |
| 102 | Supply and lay Bricks, Common Burnt, Clay Building Bricks, Sub–Class \\"B\\", of Size 230 X 115 X 75mm, Designation 75 in trenches for cable protection complete all as specified and as directed. |
| 103 | M & L for Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed. |
| 104 | Supplying and laying GI pipe, 40mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed. |
| 105 | Supplying and laying GI Tubing of 40 mm bore, Medium Grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc. fixed to walls, ceiling or laid on floors or laid in trenches including testing complete all as specified and as directed. Note: Earth work and excavation will be measured and paid separately. |
| 106 | Supplying and laying GI Tubing of 25 mm bore, Medium Grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc. fixed to walls, ceiling or laid on floors or laid in trenches including testing complete all as specified and as directed. Note: Earth work and excavation will be measured and paid separately. |
| 107 | S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 Mpa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed. |
| 108 | Dismantling Plain or Corrugated Steel Sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 109 | Dismantling of Wrought or Mild Steel Work of any description not otherwise specifically provided for complete all as specified and as directed. |
| 110 | S & F for pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm or Tiled Profile or Sinusoidal Profile and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer. |
| 111 | S & F for pre-painted Galvalume steel Plain Sheets and thickness 0.50mm [Galvalume base-PPGL Sheets], having tensile strength of 550 Mpa, in ridges, hips, valley gutters, drip and straight flashing cut to length & bent to shape, girth sheets fixed with aluminium self tapping screws of size 50/75mm and neoprene and EPDM washers of suitable size in roof covering / cladding / eves trim / rake trim and closure trim / valley rain water gutter / down spouts and top rafters etc. complete all as specified and as directed. |
| 112 | S & F Rolled Mild Steel work confirming to Fe 410-W, Grade-E- 250, Quality-A as in Plates [Plain & Chequered], Channels, Angles, square cut or notched [ordinary or counter sunk] forming holes without any attachment complete all as specified and as directed. |
| 113 | S & F MS Machine made Screw Bolts [Galvanised] with hexagonal or square head one end and screwed other or screwed both ends, fitted with washers and one hexagonal or square nut exceeding 5 cm long and not exceeding 10 cm long, dia of neck exceeding 11 mm but not exceeding 15 mm complete all as specified and as directed. |
| 114 | S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E-250, Quality-A as in Roof Trusses [framed], Trussed, Purlins, Crane Gantries, Rails and fastenings and heavy bracket framing [Beam, Tee, Angle, Channel or Flat Sections] including distance pieces, cleats etc. complete all as specified and as directed. |
| 115 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. |
| 116 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of Oil Based Bituminous Primer conforming to IS – 3384 [Latest] @ 0.3 Litre / Sq.m, laying APP Modified [Polyester Reinforced] Membrane of 3mm thick weighing not less than 3.8 KG / Sq.m confirming to IS – 16532 [2017], by torch application with side overlap of 100mm & end overlap of 150mm & tucked into the chases on vertical surfaces by thermo fusion and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately. |
| 117 | M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Sub base for Flooring / Levelling Course / Padding over roof slabs & Haunching etc., laid to required slope complete all as specified and as directed. |
| 118 | M & L for Cutting Grooves in Brick Wall / Concrete Surfaces, 30 mm wide and 25 mm deep and removing loose materials of any description and Grouting with Cement Mortar 1:3 or Cement Slurry complete all as specified and as directed. |
| 119 | Supply only Integral Liquid Water Proofing Compound [ISI marked] of approved make complete all as specified and as directed. |
| 120 | M & L for Running Welding in repairs including preparation of surfaces to be welded and thickness of metal welded not exceeding 6mm complete all as specified and as directed. |
| 121 | M & L for Running Welding in repairs not exceeding 2.5cm length including preparation of surfaces to be welded and thickness of metal welded exceeding 9mm and not exceeding 20mm complete all as specified and as directed. |
| 122 | M & L for Drilling 20mm dia holes in to the parent concrete surface to a depth of 75mm & Provide Shear Connector made of TMT Bar of 8mm to 10mm dia Rod of length of 150mm bent to \\"L\\" shape with 100mm to be perpendicular to the floor & 50mm parallel to the floor, fixed with Polyester Resin Grout mixed mechanically and pour the same in to the hole for a depth 50mm deep and insert the shear connector and finish the top, allow the same to set complete all as per manufacturer's instructions and as directed. [Make of Grout: \\"Lokfix P\\" of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited] |
| 123 | M & L for applying Chemical Injection Treatment in the form of Pressure Grouting by drilling 16 mm dia holes orthogonally, 60 mm deep @ 200 mm centre to centre in to the cracks of the Concrete Surfaces and fixing PVC Nozzles of 12mm dia One Way Injection Nipple and sealing the annular space around the Nipple with Epoxy Putty for Injecting Moisture Insensitive Epoxy Resin Injection Grout to fill the Cracks by injecting Low Viscous CONBEXTRA EP10 [M] of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent product of M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited as per Manufacturer's Instructions having minimum Mix Density of 1060 KG/Cu.m, Compressive Strength [ASTM D695] of 60 N/ Sq.mm, Tensile Strength [ASTM C307] of 20 N / Sq.mm, Flexural Strength [BS 6319] of 45 N / Sq., removing nipple after grouting and sealing with epoxy mortar etc. complete all as per Manufacturer’s instructions, all as specified and as directed. |
| 124 | M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. up to a depth of 30 to 50mm thick and trimming, cleaning the surfaces of any thickness exposed existing steel surfaces free from dust, loose material, surface contamination, rust, scale, mortar, concrete, other loose and deleterious materials, materials which reduce bond or prevent suction or wetting by repair materials, delaminating, weak, damaged and deteriorated concrete by blast cleaning or other means of mechanical abrasion or suitable means and Applying a Coat of Zinc Rich Epoxy Primer to all exposed Steel Surfaces as Antirust Agent to form 40 Microns of Dry Film Thickness and thereafter applying a Coat of Bonding Agent such as Brush Bond or Nito Bond AR of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent product of M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited as per Manufacturer's Instructions and Rendering / Applying by spraying, Single Compound, Shrinkage controlled, Polymer Modified, Fibre Reinforced Cementitious Repair Mortar such as Renderoc SP40 of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent or equivalent product of M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited by mixing 4.25 to 4.50 Litres of Water per 25 KG Bag of Renderoc SP40, of required thickness, including mixing water proofing compound as per manufacturer's instructions and finishing the top surface even and smooth without using extra cement and finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed. |
| 125 | S & F False Ceiling Frame Work using Anodised Aluminium snap grid frame work of 600 X 600 mm panel size for false ceiling with Aluminium \\"T\\" section of size 38 X 25 X 1.50 mm thick for Main Runners, 25 X 25 X 1.5 mm thick for Cross Runners and Angle of size 25 X 25 X 1.50 mm thick along the Walls suspended with and including 4 mm dia, Galvanized mild steel wire as in suspenders of ceiling members fixed in proper position including supplying and fixing Decorative PVC Board of 4 mm thick conforming to IS - 2095 for false ceiling, fixed to ceiling section with 25 mm dry wall screws at 230 mm centres complete including Dismantling Wall and Ceiling Boards [Fibre, Pulp, Insulation, etc.], or Insulation Boards / Slabs / Blankets, any thickness, including Cover Fillets complete all as specified and as directed. |
| 126 | Demolition of Brickwork or Stone / Boulder Masonry, built in Cement Mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. |
| 127 | Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. |
| 128 | M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 129 | M & L for preparing newly plastered Wall Surfaces and applying Two Coats of Acrylic Washable Distemper over a Coat of Alkali Resistant Primer complete all as specified and as directed. |
| 130 | M & L for preparation of newly plastered Wall surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint complete all as specified and as directed. |
| 131 | M & L for washing, rubbing down and stopping of distempered and painted surfaces of Walls including removing Nails etc., filling Holes and Cracks with Plaster of Paris or Cement based Wall Care Putty, rubbing smooth and applying One coat of Acrylic Washable Distemper on Wall surfaces complete all as specified and as directed. |
| 132 | M & L for complete removal of existing treatment on Wall surfaces using Vacuum based Hand held Sander Machine including removing Nails etc., filling Holes and Cracks with Plaster of Paris or Cement based Wall Care Putty, rubbing smooth and applying Two Coats of Acrylic Washable Distemper over One Coat of alkali resistant Primer complete all as specified and as directed. |
| 133 | M & L for complete removal of existing treatment on wall surfaces using Vacuum based Hand held Sander Machine including removing Nails etc., filling Holes and Cracks with Plaster of Paris or Cement based Wall Care Putty, rubbing smooth and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint complete all as specified and as directed. |
| 134 | M & L for preparation of old plastered or unplastered surfaces including brooming down or steel wire brushing including removing Nails etc., filling Holes and Cracks with Plaster of Paris or Cement based Wall Care Putty, rubbing smooth and applying One coat of White Wash on Walls complete all as specified and as directed. |
| 135 | M & L for Two Coats of Epoxy Anticorrosive Paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 136 | M & L for preparation of old painted steel surfaces of any description not other wise described over 10 cm width or girth and applying One Coat of Epoxy Anticorrosive Paint complete all as specified and directed. |
| 137 | Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed. |
| 138 | M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including Medium Grade Stove Enamelled ERW MS Conduit, ISI Marked, 20 mm dia including all accessories surface type / semi concealed type including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for Flame Proof Application of One Light / Fan Point controlled by One Switch complete all as specified and as directed. |
| 139 | S & F Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 250 Volts, 2P+Earth complete all as specified and as directed. |
| 140 | M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including Medium Grade Stove Enamelled ERW MS Conduit, ISI Marked, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia ERW MS Conduit will be measured as one unit. |
| 141 | M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including Medium Grade Stove Enamelled ERW MS Conduit, ISI Marked, 25 mm dia, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia ERW MS Conduit will be measured as one unit. |
| 142 | M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including Medium Grade Stove Enamelled ERW MS Conduit, ISI Marked, 25 mm dia, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia ERW MS Conduit will be measured as one unit. |
| 143 | S & F in repairs MCB DB, TPN, 8 Way, 415 Volts, Vertical, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified. |
| 144 | S & F in repairs MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. |
| 145 | S & F Energy efficient LED Flood Light fitting, of not less than 12000 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP66 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95. System efficacy ≥ 110/125LPW 10KV SPD included. Make: Model / Catalogue No. JETAIRISFL120WLED757APWBLTG of Havells or its Equivalent Model in Philips / Crompton Greaves / Wipro / GE / Bajaj / Jaquar |
| 146 | Taking down / Dismantling of existing Fire Alarm System complete, comprising of Fire Alarm Control Panel with Power Supply and Batteries, Detectors, Manual Call Points, Hooters / Sounders, Response Indicators, Interface Modules, Wiring with Conduits / Casing-Capping, Junction Boxes and all Accessories, of any make and capacity, including disconnection of Electrical Supply, careful removal without damage to Surrounding Structures, making good disturbed surfaces, stacking serviceable materials as directed by Engineer-in-Charge and disposal of unserviceable materials outside MD Land complete all as specified and as directed. |
| 147 | Supplying, Fixing and Replacement of UL Listed Conventional Smoke cum Heat Multi Detector with, Dual LED indication for 360° Visibility, shall be Polarity Insensitive, Insect Filter Chamber, easy to install, Advanced Detection and Communication Protocol, Operation Voltage 9 – 33 V DC complete all as specified and as directed. |
| 148 | Refixing of existing Smoke Detector Sensor, including disconnecting and reconnecting wiring, checking alignment and base fixing, tightening of terminals, cleaning of detector head, refitting to ceiling/false ceiling at the same or approved location, testing for proper operation, integration with existing fire alarm panel, and commissioning, complete all as specified and directed, including all labour, tools, tackles, consumables, and incidental works. |
| 149 | Supplying, Laying, Testing, Saddling and Glanding Termination of 2 Core, 2.50 Sq.mm, Twisted Armoured Copper Conductor Cable, including removing unserviceable Old Cable complete all as specified and as directed. |
| 150 | Refixing of existing 2 Core, 2.5 Sq.mm PVC Insulated Copper Conductor Fire Alarm Cable, including removing from existing route, straightening, dressing, re-laying and refixing on Surface / Ceiling / Wall / Conduit / Casing & Capping, including providing and fixing Clips, Saddles, Screws, Rawl Plugs as required, reconnection at both ends, testing for continuity and insulation, making good disturbed surfaces, complete all as specified and as directed. |
| 151 | Supplying, Laying and Testing FRLS Flexible Copper Cable 1100 Volts Grade of size 2 Core, 1.50 Sq.mm including removing unserviceable Old Cable complete all as specified and as directed. |
| 152 | Refixing of existing 2 Core, 1.5 Sq.mm PVC Insulated Copper Conductor Fire Alarm Cable, including removing from existing route, straightening, dressing, re-laying and refixing on Surface / Ceiling / Wall / Conduit / Casing & Capping, including providing and fixing Clips, Saddles, Screws, Rawl Plugs as required, reconnection at both ends, testing for continuity and insulation, making good disturbed surfaces, complete all as specified and as directed. |
| 153 | Inspection, Testing, Supervision of existing Fire Alarm Panels, Networking Fire Alarm Panels, Fire Alarm Repeater Panels of individual Fire Alarm Panels: [a] Inspection to be carried out for all the accessories attached to the Fire Alarm Panels. [b] Accessories testing shall be carried for Detectors, Manual Call Points, Hooters etc. [c] Rate quoted is deemed to be inclusive for carrying out the above work for all the system existing inside INS Kalinga, NAD Bheemunipatnam and INS Karna. Approximate Active System [45 Nos]. |
| 154 | Fixing or Shifting or Reinstalling old serviceable Fire Alarm Control Panel and connected accessories like Smoke Detectors, Hooters, Manual Call Points, Power Supply Wiring, Networking, FADS Network System designated Magazine or any location as directed by Engineer-in-Charge. Quoted prices deemed to be inclusive of complete wiring for Detectors and all accessories mentioned above complete all as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail