| 1 | Dismentalling of RCC work with all complete |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter includingchowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : area 3 sq. metres and below |
| 3 | Dismentalling Brick work |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of materialwithin 50 metres lead as per direction of Engineer - in - charge. |
| 5 | Dismenantlling of plaster |
| 6 | Earthwork excavation in foundation with all complete |
| 7 | PCC 1:4:8 |
| 8 | RCC 1:1.5:3 in foundation |
| 9 | RCC 1:1.5:3 in column |
| 10 | RCC beam |
| 11 | RCC slab |
| 12 | Foundation |
| 13 | Coloum |
| 14 | Mild steel or iron in plain work such as in reinforced concrete or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. Bend hooks and authorized overlapping shall be measured (@ 10% of Concrete) |
| 15 | First Class brick work in 1:6cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of materials, labour, T&P etc. required for proper completion of the work thickness of wall not be less than one brick. |
| 16 | providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand derived from natural sources : 4 graded stone aggregate 12.5mmnominal size derived from natural sources) |
| 17 | First Class brick work in 1:4cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of materials, labour, T&P etc. required for proper completion of the work thickness of wall not be less than one brick. |
| 18 | 12mm thick plaster with cement mortar in proportion of 1:4 consisting of cement and coursesand (F.M. not less than 2.25 mm) over brick work including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 19 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 20 | Finishing wall with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied a 1.43 ltri 10 sqm over and including priming coat of exterior primer applied a 2.20 10 sqm) |
| 21 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:2/21(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over theRCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 22 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete. |
| 23 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor: |
| 24 | Supplying and fxing rolling shutters of approved make, made of required size M.S. laths,interlocked together through their entire length and jointed together at the end by end locks,mounted on specially designed pipe shaft with brackets, side guides and arrangementsfor inside and outside locking with push and pull operation complete, including the cost ofproviding and fxing necessary 27.5 cm long wire springs manufactured from high tensilesteel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of requiredthickness for rolling shutters. |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 26 | earthwork in filling |
| 27 | Sand filling |
| 28 | Electrictinc fitting |
| 29 | Contegency |
| 30 | Supply and fixing of inauguration board at side with all compt. Work. |
| 31 | Add GST 18% of above cost etc. Please Enable Macros to View BoQ information |