| 1 | Taking out existing non-functional bib-cock, angle valve, pillar, showrros PVC connections etc. includng stacking of the same at proper place all complete as per dircetion of Engineer-in-Charge, |
| 2 | Dismantling existing santary ware like WC and washbasin & pedestal etc. including stacking of the dismantled material to the dumping ground all complet as per direction of Engineer-in-Charge. |
| 3 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 4 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 5 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: a) Of area 3 sq. metres and below |
| 6 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : a) W.C. pan with ISI marked white solid plastic seat and lid |
| 7 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. |
| 8 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 9 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete:a) Flexible pipe i) 32 mm dia |
| 10 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 11 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc:a) 20 mm nominal outer dia .Pipes. |
| 12 | b) 25 mm nominal outer dia .Pipes. |
| 13 | Providing and fixing uplasticised PVC connection pipe with brass unions : a) 45 cm length i) 15 mm nominal bore |
| 14 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : a) 15mm nominal bore |
| 15 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 16 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms:a) 15 mm nominal bore |
| 17 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : a) 100 mm diameter |
| 18 | Taking out grown trees/plants at different location such as shafts balconies, roofs etc. upto floor five level including demolishing brick work/tiles cement concrete so as to remove the roots of the tree/plants all complete and repairing the same with old bricks with cement mortar 1:6 (1 Cement:6 coarse sand) and providing and laying new concrete 1:2:4 ( 1 Cement :2 Coarse sand :4 graded stone aggregates 20mm nomonal size) and fishing with cement plaster 1:4 (1 Cement : 4 coarse sand ) as per the requirement and disposal of of building rubbish etc. & like all complete as per the direction of Engineer-in-Charge.(Note the agency executing the work shall have to make his own arrangement of/in scaffolding, jhulla etc. and other T&P and labour required for the job). |
| 19 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: a) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 20 | Deduct for not providing stailess steel butt hinges |
| 21 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 250x16 mm |
| 22 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : a) 250x10 mm |
| 23 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : a) 125 mm |
| 24 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 25 | Checking of RCC structural member whether the conctrete is unsound/loose or not alround and inside the building all complete as per direction of Engineer-in-Charge.( Note: Area checked but not chipped is to be measured for payment and Chipped area to be paid in separate item). |
| 26 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge:a) 25 mm average thickness |
| 27 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. a) Bars upto 12 mm diameter |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting, bending/welding, placing in position and binding all complete above plinth level:a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 29 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge:a) Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2):i) 25 mm average thickness in 2 layers. |
| 30 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC or terrace as per specifications and direction of Engineer-In-charge complete in all respect:a) SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 31 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 33 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. A) Old work (one or more coats) . |
| 34 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:a) New work (two or more coats) over and including water thinnable priming coat with cement primer: |
| 35 | Painting with superior quality synthetic enamel paint of approved brand and manufacture to give an even shade :a) One or more coats on old work |
| 36 | French spirit polishing :a)One or more coats on old work |
| 37 | Cleaning the terrazo flooring including skiting with detergent solution including rubbing, scrubbing with cloth / scrubber so that all existing black spots should be removed and joints of the mossaic tile should be filled with white cement and marble powder including using colour of required shade if required. The floor should be cleaned and washed with water mixed with oxalic acid and left to dry. all complete as per direction of Engineer-in-Charge. |
| 38 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead:a) With cement mortar 1:4(1cement:4fine sand) |
| 39 | Cleaning of toilet of any size, which includes the cleaning of wall, wall tiles, WC Pot, Wash Basin and sanitary fitting with detergent or any other chemical to make toilet sparlink clear all complete as per direction of Engineer-in-Charge. |
| 40 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 41 | Credit for unserviceable material:a) dismantled brass fittings. Please Enable Macros to View BoQ information |