| 1 | Supply, installation and commissioning of 415V, 63A MCCB box suitable for installation on wall as per Annexure 1A. | Supply, installation and commissioning of 415V, 63A MCCB box suitable for installation on wall as per Annexure 1A. |
| 2 | Supply, installation and commissioning of 415/240V, 100kVA, Dyn11, AN type Lighting Transformer with accessories as per Annexure 1A. | Supply, installation and commissioning of 415/240V, 100kVA, Dyn11, AN type Lighting Transformer with accessories as per Annexure 1A. |
| 3 | Supply, installation and commissioning of 10 meters height galvanised mild steel road lighting poles with single arm mounting bracket for LED street light fittings with LILO box, civil works etc. as per Annexure 1A. | Supply, installation and commissioning of 10 meters height galvanised mild steel road lighting poles with single arm mounting bracket for LED street light fittings with LILO box, civil works etc. as per Annexure 1A. |
| 4 | Supply, installation and commissioning of 10 meters height galvanised mild steel road lighting poles with Double arm mounting bracket for LED street light fittings with LILO box, civil works etc. as per Annexure 1A. | Supply, installation and commissioning of 10 meters height galvanised mild steel road lighting poles with Double arm mounting bracket for LED street light fittings with LILO box, civil works etc. as per Annexure 1A. |
| 5 | Supply, installation and commissioning of 240V Sub-lighting distribution board (SLDB-1) as per Annexure 1A comprising the following:Busbar - 100A TPN, Aluminium busbarsPower contactor - 100 AIncoming - One no. 100A four-pole, MCCB suitable for terminating up to 1- 3.5C, 25 sq. mm (Al) XLPE(A) cableOutgoing - Two nos. 63A four-pole MCB- Two nos. 32A double-pole MCB- Four nos. 16A double-pole MCB- Three nos. 6A double-pole MCB | Supply, installation and commissioning of 240V Sub-lighting distribution board (SLDB-1) as per Annexure 1A comprising the following:Busbar - 100A TPN, Aluminium busbarsPower contactor - 100 AIncoming - One no. 100A four-pole, MCCB suitable for terminating up to 1- 3.5C, 25 sq. mm (Al) XLPE(A) cableOutgoing - Two nos. 63A four-pole MCB- Two nos. 32A double-pole MCB- Four nos. 16A double-pole MCB- Three nos. 6A double-pole MCB |
| 6 | Supply and installation of 250A PDB/PCC panel ,3P+NL 50KA MCCB with MP based releases for O/C, S/C, E/F + RHOM + SPR + Auxiliary 1 C/O + TAC 1 C/O as per Annexure -1A | Supply and installation of 250A PDB/PCC panel ,3P+NL 50KA MCCB with MP based releases for O/C, S/C, E/F + RHOM + SPR + Auxiliary 1 C/O + TAC 1 C/O as per Annexure -1A |
| 7 | Supply, installation and commissioning of LED Street light fixtures with integrated electronic driver. The minimum lumen output of the fitting must not be less than 15000 lm and must have minimum system efficacy of 100 lm/W. The luminaries to be installed on poles including all accessories, reflective tapes, road cats eye, separate gear box chamber, dimmable programmable driver, anti-vibration devices, junction boxes, screws, check nuts, internal cables etc. as per Annexure 1A. | Supply, installation and commissioning of LED Street light fixtures with integrated electronic driver. The minimum lumen output of the fitting must not be less than 15000 lm and must have minimum system efficacy of 100 lm/W. The luminaries to be installed on poles including all accessories, reflective tapes, road cats eye, separate gear box chamber, dimmable programmable driver, anti-vibration devices, junction boxes, screws, check nuts, internal cables etc. as per Annexure 1A. |
| 8 | Supply, installation and commissioning of Surface mounted LED batten luminaire of rating 2 X 20W with integrated electronic driver. The minimum lumen output of the fitting must not be less than 3500 lm and must have a system efficacy of more than 80lm/W. The luminaries to be installed on ceiling including supply of all accessories like down rods, ball socket, junction boxes, screws, check nuts flexible conduits etc. inclusive supply of flexible conduits and flexible wires/cables as per Annexure 1A. | Supply, installation and commissioning of Surface mounted LED batten luminaire of rating 2 X 20W with integrated electronic driver. The minimum lumen output of the fitting must not be less than 3500 lm and must have a system efficacy of more than 80lm/W. The luminaries to be installed on ceiling including supply of all accessories like down rods, ball socket, junction boxes, screws, check nuts flexible conduits etc. inclusive supply of flexible conduits and flexible wires/cables as per Annexure 1A. |
| 9 | Supply & installation ,testing and commissioning of single- phase ,double door metal flush mounted type MCB distribution board suitable for 240volt,12 bay. | Supply & installation ,testing and commissioning of single- phase ,double door metal flush mounted type MCB distribution board suitable for 240volt,12 bay. |
| 10 | Supply, installation and commissioning of 240V Switch socket outlet box with RCBO as per Annexure 1A. | Supply, installation and commissioning of 240V Switch socket outlet box with RCBO as per Annexure 1A. |
| 11 | Supply, laying, termination and testing of 1.1 kV aluminium conductor XLPE (X)/PVC (P) insulated, PVC sheathed, armoured (A) power cables with accessories as per Annexure 1A of the following sizes:3.5core x 150 sqmm pvc insulated. | Supply, laying, termination and testing of 1.1 kV aluminium conductor XLPE (X)/PVC (P) insulated, PVC sheathed, armoured (A) power cables with accessories as per Annexure 1A of the following sizes:3.5core x 150 sqmm pvc insulated. |
| 12 | Supply, laying, termination and testing of 1.1 kV aluminium conductor XLPE (X)/PVC (P) insulated, PVC sheathed, armoured (A) power cables with accessories as per Annexure 1A of the following sizes:3.5core x 70 sqmm pvc insulated. | Supply, laying, termination and testing of 1.1 kV aluminium conductor XLPE (X)/PVC (P) insulated, PVC sheathed, armoured (A) power cables with accessories as per Annexure 1A of the following sizes:3.5core x 70 sqmm pvc insulated. |
| 13 | Supply, laying, termination and testing of 1.1 kV aluminium conductor XLPE (X)/PVC (P) insulated, PVC sheathed, armoured (A) power cables with accessories as per annexure 1A of the following sizes:4core x 25 sqmm pvc insulated. | Supply, laying, termination and testing of 1.1 kV aluminium conductor XLPE (X)/PVC (P) insulated, PVC sheathed, armoured (A) power cables with accessories as per annexure 1A of the following sizes:4core x 25 sqmm pvc insulated. |
| 14 | Supply, laying, termination and testing of 1.1 kV aluminium conductor XLPE (X)/PVC (P) insulated, PVC sheathed, armoured (A) power cables with accessories as per Annexure 1A of the following sizes:4core x 35 sqmm pvc insulated. | Supply, laying, termination and testing of 1.1 kV aluminium conductor XLPE (X)/PVC (P) insulated, PVC sheathed, armoured (A) power cables with accessories as per Annexure 1A of the following sizes:4core x 35 sqmm pvc insulated. |
| 15 | Concealed wiring with supply and drawing of FR PVC insulated 2.5sq. mm. multistrand ,single core,copper flexible cable in the existing recessed pvc conduit, of L&T, Finolex, Lapp ,polycab,havells make certified by E-I-C only as per IE standardwith suitable colour coding(2x2.5 sqmm + 1x2.5 sq mm earth wire) including chipping of wall, cement plaster & making good the same with supply of cement & paint (if req.) and as per direction of the Engineer-in-Charge and as per Annexure-1A | Concealed wiring with supply and drawing of FR PVC insulated 2.5sq. mm. multistrand ,single core,copper flexible cable in the existing recessed pvc conduit, of L&T, Finolex, Lapp ,polycab,havells make certified by E-I-C only as per IE standardwith suitable colour coding(2x2.5 sqmm + 1x2.5 sq mm earth wire) including chipping of wall, cement plaster & making good the same with supply of cement & paint (if req.) and as per direction of the Engineer-in-Charge and as per Annexure-1A |
| 16 | Concealed wiring with supply and drawing of FR PVC insulated 1.5 sq. mm. multistrand ,single core,copper flexible cable in the existing recessed pvc conduit, of L&T, Finolex, Lapp ,polycab,havells make certified by E-I-C only as per IE standardwith suitable colour coding(2x1.5 sqmm + 1x1.5 sq mm earth wire) including chipping of wall, cement plaster & making good the same with supply of cement & paint (if req.) and as per direction of the Engineer-in-Charge an as per Annexure-1A | Concealed wiring with supply and drawing of FR PVC insulated 1.5 sq. mm. multistrand ,single core,copper flexible cable in the existing recessed pvc conduit, of L&T, Finolex, Lapp ,polycab,havells make certified by E-I-C only as per IE standardwith suitable colour coding(2x1.5 sqmm + 1x1.5 sq mm earth wire) including chipping of wall, cement plaster & making good the same with supply of cement & paint (if req.) and as per direction of the Engineer-in-Charge an as per Annexure-1A |
| 17 | Supply and installation of GI Cable trays with accessories as per Annexure 1A of sizes as follows: 450 mm Ladder type | Supply and installation of GI Cable trays with accessories as per Annexure 1A of sizes as follows: 450 mm Ladder type |
| 18 | Supply , Fabrication and installation of MS structure base frames, supports for swithgear and brackets for miscellaneous electrical equipments, and cable tray supports out of rolled MS section of different sizes channel,angle, pipes,plates etc., as per specfications of this tender and directions of Enginer-in-Charge and as per Annexure-1A | Supply , Fabrication and installation of MS structure base frames, supports for swithgear and brackets for miscellaneous electrical equipments, and cable tray supports out of rolled MS section of different sizes channel,angle, pipes,plates etc., as per specfications of this tender and directions of Enginer-in-Charge and as per Annexure-1A |
| 19 | Supply and Installation of GI conduits with accessories as per Annexure 1A of sizes as follows: 50 mm | Supply and Installation of GI conduits with accessories as per Annexure 1A of sizes as follows: 50 mm |
| 20 | Supply and Installation of GS conduits with accessories as per Annexure 1A of sizes as follows: 25 mm | Supply and Installation of GS conduits with accessories as per Annexure 1A of sizes as follows: 25 mm |
| 21 | Supply and installation of Earthing Station consisting of 17.2 mm dia, 3 meters long solid steel rod made of high tensile low carbon steel and bonded with molecularly bonded copper on the outside as per UL 467, complete with Carbonaceous conductive/ Electrodite Back Fill Compound bricks, cement, covers and all required erection and installation materials, excavation of soil of 200 mm dia X 3000 mm deep, civil work etc. as per Annexure 1A. | Supply and installation of Earthing Station consisting of 17.2 mm dia, 3 meters long solid steel rod made of high tensile low carbon steel and bonded with molecularly bonded copper on the outside as per UL 467, complete with Carbonaceous conductive/ Electrodite Back Fill Compound bricks, cement, covers and all required erection and installation materials, excavation of soil of 200 mm dia X 3000 mm deep, civil work etc. as per Annexure 1A. |
| 22 | Supply and installation of 50 mm dia earthing coil with accessories and civil work etc. as per Annexure 1A. | Supply and installation of 50 mm dia earthing coil with accessories and civil work etc. as per Annexure 1A. |
| 23 | Supply and installation of Insulating mat as per Annexure 1A. | Supply and installation of Insulating mat as per Annexure 1A. |
| 24 | Supply and installation of GI earthing strips as per Annexure 1A of following sizes:50 mmx6 mm GMS strip | Supply and installation of GI earthing strips as per Annexure 1A of following sizes:50 mmx6 mm GMS strip |
| 25 | Supply and installation of GI earthing strips as per Annexure 1A of following sizes:25 mmx5 mm GMS strip | Supply and installation of GI earthing strips as per Annexure 1A of following sizes:25 mmx5 mm GMS strip |
| 26 | Supply and installation of 6sqmm stranded GI wire ,scope of work as per Annexure-1A | Supply and installation of 6sqmm stranded GI wire ,scope of work as per Annexure-1A |
| 27 | Supply and installation of Installation accessories (danger boards, nomenclature tags, test link, M-seal putty, danger board, nuts, clamps etc.) including installation as per Annexure 1A. | Supply and installation of Installation accessories (danger boards, nomenclature tags, test link, M-seal putty, danger board, nuts, clamps etc.) including installation as per Annexure 1A. |
| 28 | Supply, installation and commissioning of Carbon Dioxide (CO2) type portable fire extinguisher of 4.5 Kg capacity as perAnnexure 1A. | Supply, installation and commissioning of Carbon Dioxide (CO2) type portable fire extinguisher of 4.5 Kg capacity as perAnnexure 1A. |
| 29 | Supply ,installation ,testing and comissioning of Two aspect LED (RED and Green) traffic signals complete with surge protection, PIV protection and all required accessories.-as per Annexure -1A | Supply ,installation ,testing and comissioning of Two aspect LED (RED and Green) traffic signals complete with surge protection, PIV protection and all required accessories.-as per Annexure -1A |
| 30 | Supply ,installation ,testing and comissioning of Blinking amber (blinking yellow) traffic signals complete with surge protection, PIV protection, blinking controller and all required accessories-as per Annexure -1A | Supply ,installation ,testing and comissioning of Blinking amber (blinking yellow) traffic signals complete with surge protection, PIV protection, blinking controller and all required accessories-as per Annexure -1A |
| 31 | Supply ,installation ,testing and comissioning of Tubular mild steel with minimum 4000mm height, wall thickness 4.5mm traffic signal poles with base plate and two-way junction boxes complete with all required accessories.-as per Annexure -1A | Supply ,installation ,testing and comissioning of Tubular mild steel with minimum 4000mm height, wall thickness 4.5mm traffic signal poles with base plate and two-way junction boxes complete with all required accessories.-as per Annexure -1A |
| 32 | Supply ,installation ,testing and comissioning of Microcontroller based traffic signal Controller-as per Annexure -1A | Supply ,installation ,testing and comissioning of Microcontroller based traffic signal Controller-as per Annexure -1A |
| 33 | Supply ,installation ,testing and comissioning of Push Button Station for traffic Signal-as per Annexure -1A | Supply ,installation ,testing and comissioning of Push Button Station for traffic Signal-as per Annexure -1A |
| 34 | Supply ,installation ,testing and comissioning of 3 KVA UPS with heavy-duty industrial service grade sealed maintenance free (SMF) battery and battery stand and UPSDB (one no. 32A incoming and six nos. 16A outgoing).-as per Annexure -1A | Supply ,installation ,testing and comissioning of 3 KVA UPS with heavy-duty industrial service grade sealed maintenance free (SMF) battery and battery stand and UPSDB (one no. 32A incoming and six nos. 16A outgoing).-as per Annexure -1A |
| 35 | Supply ,installation ,testing and comissioning of 1.1 kV 4Core 2.5sqmm armoured copper power cable.-as per Annexure -1A | Supply ,installation ,testing and comissioning of 1.1 kV 4Core 2.5sqmm armoured copper power cable.-as per Annexure -1A |
| 36 | Supply ,installation ,testing and comissioning of Multicore (min. 7 core) armoured 1.1 KV 1.5sqmm copper control cable-400 Mtr | Supply ,installation ,testing and comissioning of Multicore (min. 7 core) armoured 1.1 KV 1.5sqmm copper control cable-400 Mtr |
| 37 | Excavation for cabling underground of 1000 mm depth, 300 mm width with sand cushioning RCC protection slabroute marker and resurfacing.as per Annexure -1A | Excavation for cabling underground of 1000 mm depth, 300 mm width with sand cushioning RCC protection slabroute marker and resurfacing.as per Annexure -1A |
| 38 | Preparation of documents, drawings, completions reports, test reports as per CEA regulations & liasoning with DMS (Electrical), Ranchi & coordination till inspection till recept of the permission to charge the installation. Only statutory expenses shall be paid by NALCO as per actuals. | Preparation of documents, drawings, completions reports, test reports as per CEA regulations & liasoning with DMS (Electrical), Ranchi & coordination till inspection till recept of the permission to charge the installation. Only statutory expenses shall be paid by NALCO as per actuals. |