| 1 | Taking down cement or cement lime plaster on brick or stone walls (upto 10 mtr ht) including raking out joints/hacking for key, scrubbing down with water etc complete all as specified. Note:- Cost of any formwork/ scaffolding shall be deemed to be included in unit rate quoted by the contractor. |
| 2 | Demolition of Brickwork or stone/boulders masonry built in cement mortar complete all as specified. |
| 3 | M&L for brickwork with subclass 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified. |
| 4 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 (except bricks) complete all as specified.Note- Bricks retrieved from items No 2 shall be reused after proper cleaning. |
| 5 | M&L for 15 mm thick Rendering in CM 1:4 in Two Coat 1st Coat 10mm and Second Coat 5 mm using with intergral water proofing liquid on brick masonry or on fair faces of brick wk (upto 6 mtr ht) & finishing the surfaces even & fair without using extra cement complete all as specified.(Note:- WPC shall be supplied and paid separately) |
| 6 | Material and labour for rough cast plaster with a mixture consisting of crushed stone or fine gravel aggregate of size 6 to 8mm as directed, mixed with coarse sand and cement in the ratio 1:1:1, finshed even over rendering with under coat 15mm thick cement and sand mortar 1:4, complete all as specified. |
| 7 | M&L for repairing of RCC projections, chajjas , roofs, facia etc by necessary preparation i.e. scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregate and reinforced with welded mesh of weight not less than 3Kg/Sqm with or without facia and finished with cement sand mortar (1:3) using coarse sand in thickness exc 50mm but n.exc 70mm including applying two coats of finishes to match with the existing surfaces in any height complete all as specified. Note:- Cost of formwork and welded mesh shall be deemed to be included in unit rate quoted by the contractor. |
| 8 | M&L for applying two coats of exterior acrylic emulsion (weather proof treatment) over one coat primer, in approved patterns/colour ,on new plastered wall/ surface (up to 10m height)etc including preparation of new surfaces complete all as specified. |
| 9 | M&L for Preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint of approved shades , complete all as specified. |
| 10 | Supply only liquid water proofing compound complete all as specified. |
| 11 | M&L for complete removal of existing treatment over Bricks/concrete/stone/ wall plastered surfaces (up to 10m height) of any description and applying Two coat of Camouflage pattern exterior emulsion paint (approved colour) over one coat of primer including necessary filling with weather coat putty work as required complete all as specified. Note :- (i) The contractor shall make arrangement the 75% quantity of material as involved in the above subject work prior to commencement of work and get verified from the Engr-In-Charge for its genuineness of material and confirmation to CA provision. The procured material shall be deposited to MES store within 15 days after approval of samples, which will be issued as the work proceeds. The contractor shall open the seal of bucket/drum of material in presence of Engr-In-Charge/JE before incorporatiion in the work and the empty bucket/drums shall be deposited to MES store after incorporation of full quantity of materials. (ii) Colour and pattern shall be approved by GE and prepared as per manufacturer's instructions. |
| 12 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level provided for complete all as specified. |
| 13 | M&L for PCC 1:3:6 type C2 (using 40 mm grade stone aggregate) 75 mm thick as in plinth protection / paving finished fair and even without using extra cement complete all as specified. |
| 14 | Material and Labour for writing letters or figures (block, roman, italic or indian) exc 5 cm but n.exc 30cm high, using synthetic enemal paint in multi story complete all as specified. |
| 15 | S&F GI pipe light grade 40 mm dia for protection of GI strip complete all as specified. (for strip protection) |
| 16 | Supply & Fix & connecting totally enclosed CMRI Certified in replacement of LED flameproof wellglass suitable for hazardous area laden with gases or vapours of Group IIA & IIB and Zone 1&2. Die Cast Aluminum housing with heat resistant toughened glass cemented into a retaining ring fixed with screws to the main housing external reflector 40/50W including matching control gears and lamp complete all as specified. |
| 17 | Taking down of old unserviceable copper / aluminium point wiring (light) with conduit complete including fitting & fixture such as switches, ceiling roses, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors etc complete all as specified. |
| 18 | M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly for the following :- |
| 19 | (a) One light point controlled by one way switch. |
| 20 | (b) One fan point controlled by one way switch. |
| 21 | (c) One 3 pin 6 Amp socket point outlet on the same board with other switches |
| 22 | (d) One 3 pin 6 Amp socket point outlet on the independent board |
| 23 | All as per item No 18 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps switch socket outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified. |
| 24 | M&L concealed point wiring complete with two runs of 2.5 sqmm, single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable, 1100volts grade IS-694 marked drawn through and including rigid steel ERW conduit min 20mm dia ( stove enameled) heavy duty as per IS 9537 Part I and including all necessary flame proof , weather proof conduit accessories and fitting fixed to concealed in wall/ceiling with teflon tape sealed in all threaded joints in conduit and fittings for light points and including 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade earth continuity wire (connecting to earth dolly) & wiring shall be done as per STEC-7 for the following :- |
| 25 | (a) Two light points controlled by one switch/MCB |
| 26 | (b) One light points controlled by one switch/MCB |
| 27 | All as ser item No 20 above but for Two light points controlled by one switch/MCB with copper cables 2.5 sqmm size. (in existing conduit) complete all as specified. |
| 28 | S&F ceiling rose surface bakelite three terminal ISI marked including suitable size of PVC board complete all as specified. |
| 29 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type multi purpose flush type 230 volt complete all as specified. |
| 30 | S&F switch piano flush button single pole one way 6 Amps 230 volt grade complete all as specified. |
| 31 | S&F switch, 15 Amp flush type, complete all as specified. |
| 32 | S&F socket 3 pin 15/16 Amps flush type, complete all as specified. |
| 33 | S&F step type electronic fan regulator EME type 450 watt complete all as specified. |
| 34 | Supply and fixing in replacement of factory made mild steel flame proof distribution boards, class LM-6 , protection class (IP-55) CMRI certified suitable for gas group IIA & IIB suitable for mounting MCB/RCCBs, DBs TP&N 4 way, 415 volts conforming to IS-2143 with minimum 200A rating copper bus bar Comprising of following :-(i) Lighting distribution panel(ii) Incoming: - MCB , 4P 63AMP - 01 Nos(iii) Outgoing :- MCB, 1P, 6AMP -12Nos |
| 35 | Supply and fixing in replacement of switch flame proof rotary type with termination box in LM6, 16 Amps single pole, 250 volts epoxy painted complete all as specified. |
| 36 | Supply and fixing in replacement of switch flame proof rotary type with termination box in LM6, 25 Amps double pole, 250 volts epoxy painted complete all as specified. |
| 37 | Supply and fixing in replacement of LED flameproof tube light fitting CMRI certified 2x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. |
| 38 | Supply and fixing in replacement of MCB SPN 6 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified. |
| 39 | Supply and fixing in replacement of MCB SPN 16 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified. |
| 40 | Supply and fixing in replacement of MCB TPN 32 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified. |
| 41 | M&L sub main wiring with two runs of single core PVC insulated but unsheathed FRLS cable of 2.5 sqmm with multi stranded copper conductors, 1100 volts grade, IS-694 marked , drawn-through rigid steel ERW conduit (stove enameled) 20 mm dia heavy duty and including suitable size and fittings/accessories, concealed in wall and also including the one run of 2.5 sqmm earth continuity conductor of similar type cable complete all as specified.Note :- Two runs of single core of 2.5 sqmm, one run of 2.5 sqmm earth continuity conductors and one run of 20mm dia ERW conduit with accessories shall be measured as one unit run length. |
| 42 | M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 20/25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 6 sqmm (FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 6 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. ( Note: Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring complete all as specified. Note: colour coding is to be maintained .(Ph-Red, N-Black, Earth- Green) |
| 43 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI strip 32x6mm as earthing lead by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 40 mm dia light grade for the protection of GI strip upto 1.5 Meter complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I.Note: earth pit cover is to be made 10mm MS Plate with the projection to overlap the four side of the road covered up to 10 cm with collapsable MS Handle including taking out old unserviceable earthing. |
| 44 | Taking out old unsv T/L and Supply & fixing LED 20 watt LED tubelight fitting retro fit type with replacable rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified. |
| 45 | Taking down old Unserviceable GI strip from wall or buried in ground or any other indicated situation including making good to disrurbed surface complete all as specified. |
| 46 | Refixing of serviceable GI Strip 32x6mm fixed on wall or buried in ground or any other indicated situation complete all as specified. |
| 47 | S&F GI Strip 32x6mm fixed on wall or buried in ground or any other indicated situation complete all as specified. Note:- Extra GI strip consider for borewell earthing which for existing earthing location |
| 48 | Taking out of old unsv copper strip and supply & fix copper strip of size 25 x 3 mm complete with insulator/saddle and fixing with screw/accessories for roof and down conductor complete all as specified. |
| 49 | Taking down old Unserviceable air termination rod of any size and capacity complete all as specified. |
| 50 | Refixing of serviceable Air termination rod as obatin from Item No 12 above including new threading and grinding of tip of air termination as per site requirnment complete all as specified. |
| 51 | S&F single pointed air termination aluminium rod 12 mm dia and 300 mm long complete all as specified. |
| 52 | Taking down old Unserviceable aluminium strip from roof and wall of ESHs any size and position including making good to disrurbed surface of wall and roof complete all as specified. |
| 53 | Refixing of serviceable aluminum strip 25x3 mm complete as obtain from above item 7 with on new saddle / insulators, including straightning and fixing screws/accessories for roof and down conductor complete all as specified.Note: (a).Fixing of serviceable insulators will be deemed to be included with quotade rate.(b). Rate of new insulators shall be deemed included in quated rate . |
| 54 | S&F aluminium srip of size 25x3 mm complete with insulator/saddle and fixing with screw/accessories for roof and down conductor complete all as specified. Note: Rate of insulators shall be deemed included in quated rate . |
| 55 | S&F in repair DMC inculator for wall down conductor for 32 X 6 and 25x3 mm strip with one meter intervel secured with suitable screw complete all as specified. |
| 56 | S&F in repair porceiline insulator for wall down conductor for 32 X 6 strip with one meter intervel secured with suitable screw complete all as specified. Please Enable Macros to View BoQ information |