| 1 | Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches or for manholes etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified. |
| 3 | Removing of surplus excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified. |
| 4 | Supply and laying HDPE DWC of 38 mm innner dia and 50 mm outer dia for underground electrical cable protection, 750 N , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge and GE. |
| 5 | Material and labour for making the hole under road and hard standing suitable for laying and inserting pipe upto 80 mm dia any length by mechanical drill system or Auger system and making the surface good as existing surface insulator with aluminium binding complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and laying XLPE LT cable of 50 sqmm, 3.5 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed by Engineer-in-charge. |
| 7 | Supply and laying XLPE LT cable of 35 sqmm, 04 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed by Engineer-in-charge. |
| 8 | Supply and laying XLPE LT cable of 16 sqmm, 04 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed by Engineer-in-charge. |
| 9 | Supply and laying XLPE LT cable of 10 sqmm, 02 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed by Engineer-in-charge. |
| 10 | Supply and Fixing cable jointing kit for Lt 1.1 KV cable for outdoor/indoor termination heat shinkable type end joint complete with jointing meterial and accessories suitable for XLPE armoured aluminium conductor cable of size 16 to 50 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 11 | Supply and fixing steel tubular decorative pole (3.0 mtr long) made of Pressure Die Cast aluminium body and opal PC cover alongwith fixing and including LED light fitting 60W, IP 66 protection and IK 07 rating, short circuit and over voltage protection facility for Driver should be potted with electrolytic capacitor of 105 degree and fiiting including making electrical connection and demolishing the existing old unserviceable pole complete all as directed.Make: HAVELLS /CG / PHILLIPS / BAJAJ. |
| 12 | M & L for sub main wiring with two runs of single core 4 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & incl steel conduit of suitable size with all accessories such as Tees, elbows,couplings, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of steel conduit shall be measured as one unit). |
| 13 | M & L for sub main wiring with two runs of single core 2.5 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & incl steel conduit of suitable size with all accessories such as Tees, elbows,couplings, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of steel conduit shall be measured as one unit). |
| 14 | S&F in replacement BOLLARD 15W new genertion energy saving environmental friendly long life aesthetically designed alumium landscape luminarie for diffused lighting with high power LED as light source complete including, PCC blocks directed by Engr-in-charge, GI pipe as required at site and connection etc complete all as specified and directed. Make: Bajaj/Crompton/Havells |
| 15 | Supply and fixing post top lantern LED type 45 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. Make: Bajaj/Crompton/Havells |
| 16 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection. Make: L&T/Havells/ |
| 17 | Supply and fixing in repair PVC junction box which shall be insulated and made out of polycarbonate with glass fiber reinforced and size should not be less than 104x104 x 70 mm, including connector strip. The polycarbonate JB shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The JB shall be rated for degree of ingress protection IP 66 in accordance with IEC 60529. The gasket material shall be polyurethane and the gasket shall be internally embedded. Make: Hensel/Legrand/Siemens |
| 18 | Supply and fixing in repair PVC junction box which shall be insulated and made out of polycarbonate with glass fiber reinforced and size should not be less than 155 x 210 x 92 mm, including connector strip. The polycarbonate JB shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The JB shall be rated for degree of ingress protection IP 66 in accordance with IEC 60529. The gasket material shall be polyurethane and the gasket shall be internally embedded. Make: Hensel/Legrand/Siemens |
| 19 | M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25m deep below the ground level with top to edge of the plate n. less than 1.5m below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified. |
| 20 | M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe of suitable dia and required length for protection of GI strip and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified. |
| 21 | M&L for bore earthing not less than 150mm dia 16 feet deep filled with black soil upto 7 feet from bottom complete with galvanized iron pipe 40mm bore medium grade 3 meter long tapers at bottom and provided 12 mm holes (staggered) at 75 mm centre to centre upto 2.5 meters of length from bottom, buried directly in ground filled with 45 cm alternate layer of chemical magnisum sulphate & salt upto ground level connected to galvanized iron strip 25x4 mm as earhing lead by means of bolts and nut, check nuts and washers of galvanized iron or steel including brazink work and 40 mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engr-in charge. |
| 22 | M & L Earth continuity conductors galvanised iron earth strip 25x4mm dia fixed to wall/ floor through protection pipe complete all as specified and directed. |
| 23 | M & L Earth continuity conductors galvanised iron earth strip 32x6mm dia fixed to wall/ floor through protection pipe complete all as specified and directed. |
| 24 | M&L for servicing and cleaning of any capacity of UPS and transporting to workshop if neccessory,checking, testing and localing faults including repairing to same by replacing new spares at work site, working electerical connection .(Note: Major Spare parts replaced shall be measured and paid separately as only item) |
| 25 | Supply only in replacement of PCB suitable for 20 to 30 KVA UPS all as specified & directed by Engr-in-Charge. |
| 26 | Supply only in replacement of PCB suitable for 2 to 15 KVA UPS all as specified & directed by Engr-in-Charge. |
| 27 | Supply only in replacement of Transformer suitable for 10 to 30 KVA UPS all as specified & directed by Engr-in-Charge. |
| 28 | Supply only in replacement of IGBT suitable for 2 to 30 KVA UPS all as specified & directed by Engr-in-Charge. |
| 29 | Supply only in replacement of capacitor suitable for 2 to 30 KVA UPS all as specified & directed by Engr-in-Charge. |
| 30 | Supply only in replacement of lead acid battery 12 volt 42 AH all as specified and directed by Engr-in-Charge. |
| 31 | Material andlabour for fault detection of non working existing Voltage stabilizers oil cooled/air cooled of different sizes upto 200 KVA at different locations by authorised service engineer including replacement of unserviceable spare parts i.e. Push Button switch,Auto manual switch, LED indicating lamp, Voltmeter,Ampre meter with C.T, PCB holder for balanced type stabilizer, Carbon brush, Trigger Transformer(9/18V) and Rotary Switch 5 Amp for R Y B Phases etc. and testing commissioning of the stabilizer on full load to the entire satisfaction of Engr in Charge. |
| 32 | S&F in repair of transformer per phase of servo voltage stabiliser of give following capacity:- |
| 33 | (a) for 10 KVA |
| 34 | (b) for 20KVA |
| 35 | (c) for 50 KVA |
| 36 | Repair and maintenance of APFC panel upto 300 KVAR rating by replacing defective parts i.e. contactors, MCB, MCCBs, capacitors, relay, indication lamps, auto manual switch, push button, cooling fan, SMPS, CTs, relay junction point/connector etc and blowing of dust by air blower, repair of panel doors by providing hinges, locking arrangement of fixing of new door of existing size including checking the wiring with complete testing of APFC relay including necessarey setting with CTs load adjustment to match the power factor in range between 0.96 to 0.99 complete all directed as specified by Engr-in-Charge. Note :- All unserviceable items repalced under repair and servicing of APFC panel shall be measured and paid separately as \\"supply only\\" as described hereinafter in respective items. |
| 37 | Supply only of capacitor duty contactor heavy duty type 3 pole AC of capacity of 10 KVAR alongwith 1 NO +1NC auxillary contact as directed. |
| 38 | Supply only of capacitor duty contactor heavy duty type 3 pole AC of capacity of 15 KVAR alongwith 1 NO +1NC auxillary contact as directed. |
| 39 | Supply only of capacitor duty contactor heavy duty type 3 pole AC of capacity of 20 KVAR alongwith 1 NO +1NC auxillary contact as directed. |
| 40 | Supply only of capacitor duty contactor heavy duty type 3 pole AC of capacity of 25 KVAR alongwith 1 NO +1NC auxillary contact as directed. |
| 41 | Supply only of capacitor duty contactor heavy duty type 3 pole AC of capacity of 5 KVAR alongwith 1 NO +1NC auxillary contact as directed. |
| 42 | Supply only APFC relay /PLC source type with protection device intelligent automatic processor has on electric controller unit upto 12 stage for contactor type APFC panel and thyristor based APFC panel with 3 CT input all as specified and diredted by Engr-in-Charge. |
| 43 | Supply only cast resin type CT coil suitable for amp meter 200/5 amp ratio complete all as directed. |
| 44 | Supply only cast resin type CT coil suitable for amp meter 800/5 amp ratio complete all as directed. |
| 45 | Supply only cast resin type CT coil suitable for amp meter 400/5 amp ratio complete all as directed. |
| 46 | Supply only of MPP capacitor 440 volts 50 Hz electric complete of capacity 10 KVAR cylindrical type gas filled as directed. |
| 47 | Supply only of MPP capacitor 440 volts 50 Hz electric complete of capacity 15 KVAR cylindrical type gas filled as directed. |
| 48 | Supply only of MPP capacitor 440 volts 50 Hz electric complete of capacity 20 KVAR cylindrical type gas filled as directed. |
| 49 | Supply only of MPP capacitor 440 volts 50 Hz electric complete of capacity 25 KVAR cylindrical type gas filled as directed. |
| 50 | Supply only of MPP capacitor 440 volts 50 Hz electric complete of capacity 5 KVAR cylindrical type gas filled as directed. |
| 51 | Supply only of indicating lamp RYB including conection for capacitors as directed. |
| 52 | Supply only Auto manual switch for APFC panel as directed. |
| 53 | Supply only in replacement of MCCB 63 Amp 3 Pole, 415 Volt, 50 Hz36 KA adjustable type complete all as specified and directed by Engr-in-Charge. |
| 54 | Supply only in replacement of MCCB 100 Amp 3 Pole, 415 Volt, 50 Hz36 KA adjustable type complete all as specified and directed by Engr-in-Charge. |
| 55 | Supply only in replacement of MCCB 160 Amp 3 Pole, 415 Volt, 50 Hz36 KA adjustable type complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply only in replacement of MCCB 250 Amp 3 Pole, 415 Volt, 50 Hz36 KA adjustable type complete all as specified and directed by Engr-in-Charge. |
| 57 | Supply only in replacement of MCCB 400 Amp 3 Pole, 415 Volt, 50 Hz36 KA adjustable type complete all as specified and directed by Engr-in-Charge.NOTE:- For item no 4 to 57:- Old retrieved material during execution of work shall deposited to AGE EM (E/S) store yard and should maintain the recored for the same . Please Enable Macros to View BoQ information |