| 1 | Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. | Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. |
| 2 | Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp. | Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp. |
| 3 | Providing and erecting Annealed bare Copper wire 8 to 16 SWG. | Providing and erecting Annealed bare Copper wire 8 to 16 SWG. |
| 4 | Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. | Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. |
| 5 | Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency. | Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency. |
| 6 | [A] For electrical installation up to 440 VLength of Pipe - 1 MtrBack filling compound - 1 Nos. of Bag of 15 Kgs. | [A] For electrical installation up to 440 VLength of Pipe - 1 MtrBack filling compound - 1 Nos. of Bag of 15 Kgs. |
| 7 | [B] For Electrical installation up to 11 KV located in other than normal soil i.e. Soft Rock, Marshy Soil etc. -Length of Pipe : 2 mtr -Back filling Compound :1 no. Bag of 25 Kg. | [B] For Electrical installation up to 11 KV located in other than normal soil i.e. Soft Rock, Marshy Soil etc. -Length of Pipe : 2 mtr -Back filling Compound :1 no. Bag of 25 Kg. |
| 8 | [C] For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA)i.e. independent Earthing located in other than normal soil i.e. Soft Rock, Marshy Soil etc..-Length of Pipe : 3 Mtrs. -Back filling Compound :2 nos Bags of 25 Kg. | [C] For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA)i.e. independent Earthing located in other than normal soil i.e. Soft Rock, Marshy Soil etc..-Length of Pipe : 3 Mtrs. -Back filling Compound :2 nos Bags of 25 Kg. |
| 9 | SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 micron copper bonding & 1 bag of Carbon fill Based environment friendly backfill tested as per IEC 62561-7 in NABL accredited Laboratory and suitable stainless Steel double sided clamp. Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). | SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 micron copper bonding & 1 bag of Carbon fill Based environment friendly backfill tested as per IEC 62561-7 in NABL accredited Laboratory and suitable stainless Steel double sided clamp. Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). |
| 10 | Supplying & erecting funnel type earthing having earth plate of following size burred in specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS (As per drawing) with following specification | Supplying & erecting funnel type earthing having earth plate of following size burred in specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS (As per drawing) with following specification |
| 11 | Providing and erecting ISI Marked 3core 240 Sq.mm XLPE insulated 11 KV armoured cable Aluminium conductor IS-7098 to be laid on wall with clamps or in provided cable trench / pipe approved manner as directed. | Providing and erecting ISI Marked 3core 240 Sq.mm XLPE insulated 11 KV armoured cable Aluminium conductor IS-7098 to be laid on wall with clamps or in provided cable trench / pipe approved manner as directed. |
| 12 | Providing and erecting cable end termination kit, heat shrinkable Push on type Densons/ Raychem/ Elastimold make suitable for 11 KV XLPE cable 3core 240 Sq.mm | Providing and erecting cable end termination kit, heat shrinkable Push on type Densons/ Raychem/ Elastimold make suitable for 11 KV XLPE cable 3core 240 Sq.mm |
| 13 | (A) Outdoor type | (A) Outdoor type |
| 14 | (B) Indoor type | (B) Indoor type |
| 15 | Supplying and erecting high tension cable end box outdoor type suitable. for 11 KV 240Sq.mm 3core H.T. cable complete with gland bushing and jointing material. | Supplying and erecting high tension cable end box outdoor type suitable. for 11 KV 240Sq.mm 3core H.T. cable complete with gland bushing and jointing material. |
| 16 | Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50\\" diagonally size. | Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50\\" diagonally size. |
| 17 | Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50\\" diagonally size. | Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50\\" diagonally size. |
| 18 | Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. | Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. |
| 19 | Supplying rubber matting of following thickness as per IS:15652/IEC 61111 | Supplying rubber matting of following thickness as per IS:15652/IEC 61111 |
| 20 | (b)4mm | (b)4mm |
| 21 | (c)12mm | (c)12mm |
| 22 | Supplying & fixing Steel Chequered Plate having 10 mm thickness,with handle duly painted with two coats of black Japan colour. (Average Wt 84.6 kg / Sq.Mtr) | Supplying & fixing Steel Chequered Plate having 10 mm thickness,with handle duly painted with two coats of black Japan colour. (Average Wt 84.6 kg / Sq.Mtr) |
| 23 | Supplying & fixing Steel Chequered Plate having 12 mm thickness, duly painted with two coats of black Japan colour. (Average Wt 200.3 kg / Sq.Mtr) | Supplying & fixing Steel Chequered Plate having 12 mm thickness, duly painted with two coats of black Japan colour. (Average Wt 200.3 kg / Sq.Mtr) |
| 24 | Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes) | Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes) |
| 25 | Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall complete. | Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall complete. |
| 26 | [A] For 5 Kg Capacity | [A] For 5 Kg Capacity |
| 27 | [B] For 10 KG Capacity | [B] For 10 KG Capacity |
| 28 | Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. | Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. |
| 29 | [A] For 4.5 Kg Capacity | [A] For 4.5 Kg Capacity |
| 30 | [B] For 5.5 / 6.5 KG Capacity | [B] For 5.5 / 6.5 KG Capacity |
| 31 | Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook. | Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook. |
| 32 | Supplying and erecting floor mounting stand for keeping four nos. of FIRE buckets comprising 1500 mm in length, 900 mm height frame made out of 30mm X30 mm X 4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint. | Supplying and erecting floor mounting stand for keeping four nos. of FIRE buckets comprising 1500 mm in length, 900 mm height frame made out of 30mm X30 mm X 4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint. |
| 33 | Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod grouted in wall to a depth of minimum 15 cms. | Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod grouted in wall to a depth of minimum 15 cms. |
| 34 | Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS. | Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS. |
| 35 | Providing and erecting metallic vitrified danger notice board for HIGH VOLTAGE installation to be erected as per IS. | Providing and erecting metallic vitrified danger notice board for HIGH VOLTAGE installation to be erected as per IS. |
| 36 | Providing & erecting Medium/LOW Voltage Danger Notice Board sticker of standard size | Providing & erecting Medium/LOW Voltage Danger Notice Board sticker of standard size |
| 37 | Providing & erecting High Voltage Danger Notice Board sticker of standard size | Providing & erecting High Voltage Danger Notice Board sticker of standard size |
| 38 | SUPPLY & ERECTING OF UR 12 KV, IR 400A, ISC25KA, UP12KV 50HZ | SUPPLY & ERECTING OF UR 12 KV, IR 400A, ISC25KA, UP12KV 50HZ |
| 39 | SUPPLY & ERECTING OF 3 C/O + 1 EARTH FOULT RELAY | SUPPLY & ERECTING OF 3 C/O + 1 EARTH FOULT RELAY |
| 40 | SUPPLY & ERECTING OF 86 HIGH SPEED MASTER TRIP RELAY 110-125V | SUPPLY & ERECTING OF 86 HIGH SPEED MASTER TRIP RELAY 110-125V |
| 41 | SUPPLY & ERECTING OF BUACH TRIP RELAY-110-125V | SUPPLY & ERECTING OF BUACH TRIP RELAY-110-125V |
| 42 | SUPPLY & ERECTING OF WTI TRIP RELAY-110-125V | SUPPLY & ERECTING OF WTI TRIP RELAY-110-125V |
| 43 | SUPPLY & ERECTING OF OTI TRIP RELAY-110-125V | SUPPLY & ERECTING OF OTI TRIP RELAY-110-125V |
| 44 | SUPPLY & ERECTING OF M2-8 POGRAMMABLE ANNUNCIATOR V2.0 | SUPPLY & ERECTING OF M2-8 POGRAMMABLE ANNUNCIATOR V2.0 |
| 45 | SUPPLY & ERECTING OF MULTIFUNCTION METER | SUPPLY & ERECTING OF MULTIFUNCTION METER |
| 46 | SUPPLY & ERECTING OF DIGITAL AMMETER | SUPPLY & ERECTING OF DIGITAL AMMETER |
| 47 | SUPPLY & ERECTING OF DIGITAL VOLTMETER | SUPPLY & ERECTING OF DIGITAL VOLTMETER |
| 48 | SUPPLY & ERECTING OF TNC SWITCH | SUPPLY & ERECTING OF TNC SWITCH |
| 49 | SUPPLY & ERECTING OF TCH PUSH BUTTON WITH LAMP (WHITE) | SUPPLY & ERECTING OF TCH PUSH BUTTON WITH LAMP (WHITE) |
| 50 | SUPPLY & ERECTING OF LOCAL REMOTE 2POLE 2WAY | SUPPLY & ERECTING OF LOCAL REMOTE 2POLE 2WAY |
| 51 | SUPPLY & ERECTING OF LED Type Indicating lamp (Red) | SUPPLY & ERECTING OF LED Type Indicating lamp (Red) |
| 52 | SUPPLY & ERECTING OF LED Type Indicating lamp (YELLOW) | SUPPLY & ERECTING OF LED Type Indicating lamp (YELLOW) |
| 53 | SUPPLY & ERECTING OF LED Type Indicating lamp (BLUE) | SUPPLY & ERECTING OF LED Type Indicating lamp (BLUE) |
| 54 | SUPPLY & ERECTING OF ON LED Type Indicating lamp (RED) | SUPPLY & ERECTING OF ON LED Type Indicating lamp (RED) |
| 55 | SUPPLY & ERECTING OFOFF LED Type Indicating lamp (GREEN) | SUPPLY & ERECTING OFOFF LED Type Indicating lamp (GREEN) |
| 56 | SUPPLY & ERECTING OF TRIP LED Type Indicating lamp (AMBER) | SUPPLY & ERECTING OF TRIP LED Type Indicating lamp (AMBER) |
| 57 | SUPPLY & ERECTING OF SPRING CHARGE LED TYPE LAMP (BLUE) | SUPPLY & ERECTING OF SPRING CHARGE LED TYPE LAMP (BLUE) |
| 58 | SUPPLY & ERECTING OF VCB TEST LED TYPE LAMP (WHITE) | SUPPLY & ERECTING OF VCB TEST LED TYPE LAMP (WHITE) |
| 59 | SUPPLY & ERECTING OF VCB SERVICE LED TYPE LAMP (YELLOW) | SUPPLY & ERECTING OF VCB SERVICE LED TYPE LAMP (YELLOW) |
| 60 | SUPPLY & ERECTING OF CLOSE PUSH BUTTON WITH ELEMENTS(BLACK) | SUPPLY & ERECTING OF CLOSE PUSH BUTTON WITH ELEMENTS(BLACK) |
| 61 | SUPPLY & ERECTING OF ELECTRONIC HOOTER | SUPPLY & ERECTING OF ELECTRONIC HOOTER |
| 62 | SUPPLY & ERECTING OF DC POWER PACK(230VAC I/P, 110VDC O/P) | SUPPLY & ERECTING OF DC POWER PACK(230VAC I/P, 110VDC O/P) |
| 63 | SUPPLY & ERECTING OF 16A DP 10KA MCB WITH C CURVE | SUPPLY & ERECTING OF 16A DP 10KA MCB WITH C CURVE |
| 64 | SUPPLY & ERECTING OF 10A DP 10KA MCB WITH C CURVE | SUPPLY & ERECTING OF 10A DP 10KA MCB WITH C CURVE |
| 65 | SUPPLY & ERECTING OF 6A DP 10KA MCB WITH C CURVE | SUPPLY & ERECTING OF 6A DP 10KA MCB WITH C CURVE |
| 66 | SUPPLY & ERECTING OF 3C/O RELAY WITH BASE 110VDC | SUPPLY & ERECTING OF 3C/O RELAY WITH BASE 110VDC |
| 67 | SUPPLY & ERECTING OF TERMINAL TYPE NEUTRAL LINK | SUPPLY & ERECTING OF TERMINAL TYPE NEUTRAL LINK |
| 68 | SUPPLY & ERECTING OF BRIDGE RECTIFIRE | SUPPLY & ERECTING OF BRIDGE RECTIFIRE |
| 69 | SUPPLY & ERECTING OF HEATER ON/OFF SWITCH | SUPPLY & ERECTING OF HEATER ON/OFF SWITCH |
| 70 | SUPPLY & ERECTING OF 5/15A SOCKET WITH SWITCH | SUPPLY & ERECTING OF 5/15A SOCKET WITH SWITCH |
| 71 | EARTHING SYSTEM FOR HT 11KV CHARCOL | EARTHING SYSTEM FOR HT 11KV CHARCOL |
| 72 | EARTHING SYSTEM FOR HT 11KV CHARCOL WITH UPTO 3 MTR DEPTH | EARTHING SYSTEM FOR HT 11KV CHARCOL WITH UPTO 3 MTR DEPTH |
| 73 | EARTHING SYSTEM FOR LT 440 V CHEMICAL UPTO 2 MTR DEPTH | EARTHING SYSTEM FOR LT 440 V CHEMICAL UPTO 2 MTR DEPTH |
| 74 | EARTHING SYSTEM FOR LT 440 V CHARCOL UPTO 2 MTR DEPTH | EARTHING SYSTEM FOR LT 440 V CHARCOL UPTO 2 MTR DEPTH |
| 75 | ONE-TIME JOB FOR UPDATING ALL PREVENTIVE MAINTENANCE OF EXISTING TRANSFORMERS AT CAMPUS 1 (2 NOS.) | ONE-TIME JOB FOR UPDATING ALL PREVENTIVE MAINTENANCE OF EXISTING TRANSFORMERS AT CAMPUS 1 (2 NOS.) |
| 76 | ELECTRICAL NOC – CLEARING ALL CHARGES AND EXEMPTION OF LEGAL FEES | ELECTRICAL NOC – CLEARING ALL CHARGES AND EXEMPTION OF LEGAL FEES |