| 1 | Deployment of AC mechanic for attending the Complaints immediately on daily basis and to be rectified the same day at the earliest without affecting the service of AC any type for minor defects and making it in working condition at any location of Cantt area complete. |
| 2 | M&L for dismantling of burnt contactor and Supply & fix power contactor 1ph complete all as specified and directed by EIC. |
| 3 | M&L for dismantling of defective outdoor stand of split AC and supply & fixing outdoor stand of split AC at suitable location complete all as specified and directed by EIC. |
| 4 | M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 36 Mfd in plastic/ metal container complete all as directed by EIC. |
| 5 | M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 50+5Mfd in plastic/ metal container complete all as directed by EIC. |
| 6 | M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 45 Mfd in plastic/ metal container complete all as directed by EIC. |
| 7 | M&L for defective gurmut and Supply & Fix Gurmut suitable for any type AC complete all as directed by EIC. |
| 8 | M&L for dismantling of burnt Censor and Supply & Fix Censor (in each set) of Indoor unit/ outdoor unit of Split AC Inverter type (Cooling / Hot and cold type) of any make and model for 1.5 TR / 2 TR capacities completed. |
| 9 | M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR of split AC/ window AC all as directed by EIC. |
| 10 | M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR of split AC Inverter type (cooling only / hot & cold type) all as directed by EIC. |
| 11 | M&L for dismantling of defected brass valve and Supply & fix brass valve size 5/8\\" or 3/8 \\" complete all as specified and directed |
| 12 | M&L for dismantling of defected brass valve and Supply & fix brass valve size 1/2\\" or 1/4\\" complete all as specified and directed . |
| 13 | M&L for dismantling of defected flare nuts and Supply & fix flare nuts size 5/8 \\" or 3/8\\" complete all as specified and directed |
| 14 | M&L for dismantling of defected flare nuts and Supply & fix flare nuts size 1/2 \\" or 1/4\\"complete all as specified and directed |
| 15 | M&L for dismantling of defected Dead nuts and Supply & fix Dead nuts size 1/2\\" or 1/4 \\" complete all as specified and directed |
| 16 | M&L for dismantling of defected Dead nuts and Supply & fix Dead nuts size 5/8\\" or 3/8 \\" complete all as specified and directed |
| 17 | Supply and fix in repair/ replace of Pin Valve complete all as specified |
| 18 | M&L for dismantling of defected copper gas filter and Supply & fix copper Gas filter for AC 1.5 TR / 2 TR capacity all as specified and directed |
| 19 | M&L for dismantling of burnt connector and Supply & fix connector suitbale for any type AC complete all as specified and directed by Engineer-in- Charge. |
| 20 | M&L for renew PVC insulated three core stranded copper cable of size 80/0.20 ( 2.5 sqmm) all as specified and directed . |
| 21 | M&L for renew MCB SP -6 to 32 Amps rating 'C' curve complete all as specified and directed |
| 22 | M&L for renew Mettalic Plugs ( top) of AC box 20A, specified make , 2P+E and connecting all as specified and directed |
| 23 | M&L for repair/ renew copper capillary of size 0.60 mm complete all as specified and directed |
| 24 | M&L for renew of modular type AC box with SP MCB suitable rating make of box philips/ Havells/ crompton complete all as specified. |
| 25 | M&L for copper tube leaked repaired of any type AC of 1.5 TR/ 2.0TR capacity at any location of cantt area after repaired of tube by brazing, testing of leakage, vaccumnisation and charging of refrigerant gas required to make it fully functional complete all as directed by EIC. Note :- Refrigerant gas will be provided by Contractor |
| 26 | Supply only of puff insulation of size 1/2\\" or 1/4 \\" suitable for AC covering with packing tape complete all as per specified and directed by EIC |
| 27 | Supply only of puff insulation of size 5/8\\" or 3/8\\" suitable for AC covering with packing tape complete all as per specified and directed by EIC |
| 28 | Supply and fix PVC pipe heavy duty for water drain of AC all as specified and directed. |
| 29 | Supply and fix in repair of copper tubing 5/8\\"dia complete all as specified and directed . |
| 30 | Supply and fix in repair of copper tubing 3/8\\"dia complete all as specified and directed . |
| 31 | Supply and fix in repair of copper tubing 1/2\\" dia complete all as specified and directed . |
| 32 | Supply and fix in repair of copper tubing 1/4\\" dia complete all as specified and directed . |
| 33 | Supply and fix remote hand set of window/ Split air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar) |
| 34 | Supply and fix remote hand set of Inverter type Split air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar) |
| 35 | Supply and fix in repair Air Censor for temperature control for any type AC complete all as specified and directed. |
| 36 | Supply and fix PVC fan blade of window/ Split AC , complete all as directed by EIC |
| 37 | Supply and fix PVC blower for window A.C. as per sample complete all as specified and directed |
| 38 | Supply & fix clips & clamps size 40mm for fixing copper pipe of AC complete all as specified and directed |
| 39 | Supply & fix clips & clamps size 16mm for fixing drain pipe of AC complete all as specified and directed |
| 40 | M&L for taking down of Split type AC (Indoor & outdoor complete) of any capacity or model and transporting and refixing at New Location to make it fully functional again at new location with all as specified and directed by Engr-In -Charge. |
| 41 | M&L for taking down of Window AC any capacity or model, transporting and refixing at New Location to make it fully functional again all as specified and directed by Engr-In -Charge. |
| 42 | Taking out defective motor from window/ Split type AC of cap 1.5/2.0 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed. |
| 43 | Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC ( indoor unit) and supply & fixing new blower motor Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed. |
| 44 | Dismantling of burnt outdoor fan motor of 1.5 TR/2.0TR split AC (outdoor unit) and supply & fixing new outdoor fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed. |
| 45 | Dismantling of existing window type AC. from its location and refixing after doing by Servicing with water pressure jet complete all as directed by EIC. |
| 46 | Taking down indoor unit of split AC any type for carrying out repairs and renewal/ replacements of Parts including servicing, after repaired the same, reassemble and installation on existing same location with complete all as specified and directed.(Note :- M&L for parts renew/ replacements shall be measured and paid separately under appropriate item(s) |
| 47 | Taking down outdoor unit of Tower Ac/ split AC any type and transporting from site to contractor workshop for carrying out repairs and renewal/ replacements of Parts including servicing, after repaired the same, transporting back to site, required to make it fully functional reassemble and installation on existing same location with complete all as specified and directed.(Note :- M&L for parts renew/ replacements shall be measured and paid separately under appropriate item(s) |
| 48 | M&L for Water dropping leaked repaired of any type AC at any location of cantt area with complete all as directed by EIC |
| 49 | M&L for convert to heating/ cooling mode (only reverse cycle connection) in Split AC, Window AC of any make, model and capacity by AC mechanic at any location of cantt area with complete all as directed by EIC |
| 50 | M&L for Renewal of plywood 6 mm thick,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished to cover space of window or wall for fix of window AC any capacity to complete as directed by EIC |
| 51 | M&L for Renewal wood for fillets, cross sectional area excd 3 and not excd 6 sqmm on all four sides of window type AC splayed or chamfered edge complete all as specified and directed. |
| 52 | Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing new indoor unit hot & cold type with minimum cooling capacity 5200W with blower motor, cooling coil, front grill, Remote hand set with pencil cell, flexible cable make Voltas, O-general, Llyod, LG, Hitachi and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required complete. |
| 53 | Dismantling of defective cooling coil of 1.5 TR/2.0 TR window type AC/ Split type AC of any make and S&F cooling coil in copper by brazing, leak proove and vaccumination complete all as specified and directed |
| 54 | Dismantling of defective condencing coil of 1.5 TR/2.0 TR window type AC/ Split type AC of any make and S&F condencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed |
| 55 | Dismantling of burnt fan motor of 1.5 TR/2.0TR window AC double shaft and supply & fixing new fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed. |
| 56 | Dismantling of unserviceable compressors of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary Inverter type or Non-Inverter type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC.Note :_(i) Refrigerant gas will be provided by contractor(ii) The electrical accessories required will be measured and paid for separately. (iii) The compressor of make – Carrier/ Kirloskar/ Blue star |
| 57 | Description all as per item 56 but size 2.0 TR |
| 58 | Supply and fixing in repairs front grill for window AC of 1.5 TR/ 2 TR of Make National/ Casmo/LG/Carrier / Blue Star/Samsung/ Voltas all as specified and directed |
| 59 | M&L for fabrication of Tray for Window AC made out of 24 SWG 10mm aperture including rivetting brazing /soldering including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations complete all as specified and directed. |
| 60 | M & L for servicing of Split AC/ tower AC Indoor & out door unit complete by water pressure jet & jacket ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc complete all as specified and directed by EIC. |
| 61 | M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22/R-32/R-410 into the system for 1.5 TR/2.0 TR capacity split AC/ window AC all as specified and directed. (The refrigerant gas will be provided by Contractor) |
| 62 | Supply & Charging by Top up of refrigerant in the AC unit of 1.5 TR / 2 TR split AC/ window AC/ Tower AC unit with refrigerant gas R-22/R-32/R-410 in required Qty complete all as specified and directed (The refrigerant gas will be provided by Contractor) |
| 63 | Supply & fix New display suitable for Split AC/ window AC/ Tower AC of any make/ model & capacity complete all as directed by EIC |
| 64 | Supply & fix New display suitable for Inverter Split AC (cooling or Hot & cold type) of any make/ model & capacity complete all as directed by EIC |
| 65 | M&L for dismantling of defective display of 1.5/2.0 TR capacity Split AC/ Window AC of any make and transporting to contractors workshop for repair of the same,transporting back to site & refixing to ensure proper functioning of the AC complete all as specified and directed. |
| 66 | Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC ( indoor unit) Inverter Split AC and supply & fixing new blower motor of Inverter Split AC (Cooling or hot & cold type) Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed. |
| 67 | Dismantling of burnt outdoor fan motor of 1.5 TR/2.0 TR split AC ( outdoor unit) Inverter Split AC and supply & fixing new outdoor fan motor of Inverter Split AC (Cooling or hot & cold type) Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed. |
| 68 | S&F reverse cycle solenoid valve in split type AC 1.5 / 2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as specified and directed by Engineer-in- Charge. |
| 69 | Dismantling of defective condensing unit (outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit (outdoor unit) hot & cold type with minimum cooling capacity 5200W complete with compressor, copper condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade make Voltas, O-general, Hitachi, LG, Llyod and including copper tube with puff insulation of suction and discharge suitable size complete all as directed . |
| 70 | S&F in replacement New PCB for Split AC/ window AC of any make/ type complete all as specified and directed. |
| 71 | M&L for dismantling of defective PCB of 1.5/2.0 TR capacity Split AC/ window AC of any make and transporting to contractors workshop for repair of the same,transporting back to site & refixing to ensure proper functioning of the AC complete all as specified and directed. |
| 72 | S&F in replacement New PCB for indoor unit of (Make-Samsung / LG / Voltas / Daikin / Hitachi / Carrier) of Cap 1.5 / 2.0 TR Split AC Inverter type( cooling only/ hot & cold) complete all as specified and directed. |
| 73 | S&F in replacement New PCB for Outdoor unit (Make-Samsung / LG / Voltas / Daikin / Hitachi / Carrier) of Cap 1.5 / 2.0 TR Split AC Inverter type ( cooling only / hot & cold) complete all as specified and directed. |
| 74 | M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC inverter type (cooling only/ hot & cold) of any make from indoor or outdoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed. |
| 75 | Supply and fix in repair Polycarbonate Plug top 3 pin 16 Amp complete all as specified and directed. Make :- Anchor/ABB/Havelles/C&S . |
| 76 | Dismantling desert cooler of any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts & motor, reassembling and installation of the same on same location and making electric connection required to make fully functional etc. complete all as specified and directed.(Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow. |
| 77 | Supply only of PVC front grill of crompton, champion, khaitan make complete all as specified and directed. |
| 78 | Supply only of Piano switch (5/6 Amp) suitable for desert cooler complete all as specified and directed. ( Make :- Anchor/ABB/Havells) |
| 79 | Supply only of PVC gang box/ distribution box suitable for two nos piano switch (5/6 Amp) suitable for desert cooler complete all as specified and directed. |
| 80 | Supply and fix in repair Polycarbonate Plug top 3 pin 5/6 Amp complete all as specified and directed. Make :- Anchor/ABB/Havelles/C&S |
| 81 | Supply only of PVC elbow suitable for 15mm dia pipe of desert cooler complete all as specified and directed. |
| 82 | Supply only of PVC distirbutor suitable for 15mm dia pipe of desert cooler complete all as specified and directed. |
| 83 | Supply only of copper conductor twin core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for pannel wring of desert cooler complete all as specified and directed. |
| 84 | Supply only of copper conductor three core PVC insulated and sheathed cable size 1.50 sqmm ISI mark for pannel wring of desert cooler complete all as specified and directed. |
| 85 | Supply only of PVC pipe heavy duty 15 mm dia for desert cooler pump to distributor/ distributor to elbow complete all as specified and directed. |
| 86 | Supply only of replacement submersible pump for desert cooler single phase, 1/40 HP, 230 volts make champion, khaitan, crompton complete all as specified and directed. |
| 87 | Supply only of Exhaust fan/ Kit fan metal blades 18\\"/20\\" sweep heavy duty make champion, crompton, khaitan complete all as specified and directed. |
| 88 | Supply only 18\\" frame heavy duty suitable for exhaust fan motor make champion, crompton, khaitan complete with nuts & bolts/ screw all as specified and directed |
| 89 | Supply only legs heavy duty suitable for exhaust/ kit fan motor complete with nut & bolts/ scre all as specified and directed. |
| 90 | Supply only ring heavy duty suitable for exhaust/ kit fan motor complete with nut & bolts/ scre all as specified and directed |
| 91 | Supply only of wood wool pad (As per sample) including wiremesh (jali) suitable for desert cooler 325 mm to 500mm sweep complete all as specified and directed. |
| 92 | Supply only kit fan motor, 1400 RPM, copper winding, less consumption of electricity, more durable, heavy duty, single phase, 230 volt AC, complete with capacitor make champion/ crompton, khaitan suitable for desert cooler complete all as specified and directed. |
| 93 | Supply only exhaust fan motor, 1400 RPM single phase, 230 volt AC, copper winding less consumtion of electricity, more durable heavy duty complete with capacitor make champion/ crompton, khaitan suitable for desert cooler complete all as specified and directed. |
| 94 | M& L for fabrication of mild steel cooler stand size 60x70x80 cm( LxWxH) angle iron of 32 x 5 mm as directed conforming to Fe-290 Gde E-165, including cutting, welding, cross support in upper side and lower side with flat iron or angle iron size 32x5 mm etc as directed or grauting (if required)of angle iron in wall suitable for postioning of desert cooler,making good of disturbed surfaces including two coat black paint over a coat of red oxide primer and installed at location as directed. |
| 95 | Taking out defective burnt exhaust fan of following sweep and of any make and transporting to contactor's workshop, opening of exhaust fan/taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, reassembling testing and fixing in position 18\\"/24\\" size (exhaust fan) complete all as specified and directed. |
| 96 | M&L for spray painting of any type desert cooler with synthetic enamel paint make berger, nerolac, asian of approved color (inside and outside) and reassembling and fixed in existing location complete all as specified and directed. |
| 97 | M&L for dismantling of defective desert cooler body and supply & fixing new desert cooler body factory made powder coated 22 gauge PGI sheet of size 100x70x60cm approx, make Champion, crompton, khaitan with front grill, side panel include wood wool pad/ wiremesh set, submersible pump, front grill, switch, regulator, flexible cable include plug top suitable for 450 mm/500 mm sweep exhaust fan complete all as specified and directed. |
| 98 | Dismantling of existing repairable water cooler of any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling and installation of the same on same location and making electric connection etc. to make it fully functional complete all as specified and directed.(Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow. |
| 99 | Supply only of CP pipe connector including flange, screw, CP nozzle of nipple, female nozzle and extention complete all as specified and directed |
| 100 | Supply only of blower/ fan motor with blade AC 240 volts, 50 HZ single phase, of water cooler any capaciites complete all as specified and directed. |
| 101 | Supply only of aluminium fan blade of blower motor of any capacity complete all as specified. |
| 102 | Supply only of PVC fan blade of blower motor of any capacity complete all as specified. |
| 103 | Supply only CP Brass push cock (inner or outer threaded) of 15 mm bore size complete all as directed by the Engineer-in-Charge. |
| 104 | Supply only of 32 mm PVC pipe with clip and strainer tee Elbow all as specified and directed by Engineer-in-Charge. |
| 105 | Supply only of starting relay for water cooler/ Refrigerator/ Deep Freezer of any capacity complete all as specified and directed . |
| 106 | Supply only capacitor 4/ 6 mfd complete all as specified and directed . |
| 107 | Supply only of capacitor 2.5 Mfd capacity all as specified and directed |
| 108 | Supply only of 10 mfd capacities complete all as specified and directed. |
| 109 | Supply only of overload protector for water cooler/ Refrigerator/ Deep Freezer of any capacity complete all as specified and directed . |
| 110 | Supply only of Thermostat any type for water cooler/ Refrigerator/ Deep Freezer complete all as specified and directed |
| 111 | Supply only of gas filter and capillary tube all as specified and directed by EIC. |
| 112 | Supply only PVC connection 15mm dia with brass ferule both and length 600mm complete all as specified and directed |
| 113 | Supply only of float valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified. |
| 114 | M&L for fabrication or repair tray, panel, legs, lead and other connected items including motor base such as nut & bolts, screws complete of water cooler of any capacities all as specified and directed. |
| 115 | Checking of leakage in refrigerant system of water cooler of any capacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
| 116 | M&L for servicing of water cooler of any capacity including internal wash with surf and fresh water complete all as specified |
| 117 | Transporting defective blower/ fan motor of water cooler/ Deep freezer/ Refrigerator of any capacities from AGE E/M yard to contractor's workshop, dismantling the burnt winding & rewinding of blower motor with the existing size super enameled copper winding wire including insulation, varnishing, greasing, testing and transporting back to AGE E/M yard for refixing at the site complete all as specified and directed. |
| 118 | Dismantling of unserviceable compressor of any make/brand from water cooler including disconnecting suction / Discharge copper tubing and Supply & fixing new compressor suitable for 150/150 ltr capacity water cooler (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas (Make Emmerson Model HR-13) or equivalent of other specified make & Model complete all as specified and directed. Note : Refrigerant gas will be provided by contractor. |
| 119 | All description as per above item No 118 but size for 60/120 ltr |
| 120 | All description as per above item No 118 but size for 40/80 ltr |
| 121 | M&L for shifting of compressor from any machinery of any make by cutting of suction and discharge lines for carrying out necessary repairs including nuts & bolts , washers, and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas in required quantities and testing complete all as specified and directed by. Note : Refrigerant gas will be provided by contractor. |
| 122 | Dismantling of existing repairable refrigerator any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling and installation of the same on same location and making electric connection etc. to make it fully functional complete all as specified and directed.(Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow. |
| 123 | Supply only Fan motor with blade of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
| 124 | Supply only Tharmal fuse of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
| 125 | Supply only Timer of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
| 126 | Supply only Bimetal of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
| 127 | Supply only lamp of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
| 128 | Supply only Defrost Heater of Refrigerators suitable for any make/ model & capacities complete all as specified and directed. |
| 129 | S&F new PCB Inverter or Non-inverter type for refrigerators any capacity, complete all as specified and directed. (Make-Samsung/LG or others as required) |
| 130 | M&L for dismantling of defective PCB of Refrigerator Inverter/ Non-inverter type of any make, model and capacity and transporting to contractors workshop for repair of the same,transporting back to site & refixing to Refrigerator to ensure proper functioning of the AC complete all as specified and directed. |
| 131 | S&F new Freezer of refrigerator capcity upto 240 ltrs complete all as specified and directed. (Make-Samsung/LG or others as required) |
| 132 | S&F new Freezer of refrigerator capacity above 240 ltrs complete all as specified and directed. (Make-Samsung/LG or others as required) |
| 133 | M&L for servicing of Refrigerators any type including internally cleaning with washing powder and with fresh water and to make it fully function complete all as specified and directed. |
| 134 | S&F condensing coil of refriferator capacity upto 240 litres by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as specified and directed. Note : Refrigerant gas will be provided by contractor. |
| 135 | All as per item 134 above but for capacity above 240 litres of refrigrators |
| 136 | Checking of leakage in refrigerant system of refrigerator of any capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
| 137 | Taking down unsv compressor from the regrigerator and Supply and fixing new sealed unit compressor suitable for 165/190/195 litres refrigerator, charging with gas and making connections and testing complete all as specified Make- LG/Whirlpool/Samsung/Godrej). Note : Refrigerant gas will be provided by contractor. |
| 138 | Description all as per item 137 above but for capacity of 240/286/300/310 ltrs refrigrators. |
| 139 | Dismantling of existing repairable Deep freezer any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling and installation of the same on same location and making electric connection etc. complete all as specified and directed.(Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow. |
| 140 | Dismantling of unserviceable compressor of any make/brand from deep freezer including disconnecting suction / Discharge copper tubing and Supply & fixing new compressor suitable for 200 ltr deep freezer (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas (Make Emmerson Model KCN 372) or equivalent of other specified make & Model complete all as specified and directed. Note : Refrigerant gas will be provided by contractor. |
| 141 | All as per item No above 140 but 300 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar |
| 142 | Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed. |
| 143 | Renewal of Fan Motor with blade of deep freezer, 230Volts rating, AC, Single Phase, 50 Hz including disconnection and reconnecting and testing complete all as specified and directed. |
| 144 | M&L for taking down unserviceable voltage stablizers of any make of following capacities and dismantling the stablizers of any size for repair of the defective parts/spares & ressembling including repairs of defective screws, rubber shose testing and after repair refixing the same at existing location complete all as specified and directedNote:- Spare parts measured and paid seprately |
| 145 | Supply only relay 25/30 Amps 24 volts for 4 KVA/5KVA voltage stablizers complete all as specified and directed |
| 146 | M&L for repair main PCB/ relay PCB suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed |
| 147 | Supply only power transfromers suitable for voltage stablizers of capacity 4/5 KVA all as specified and directed |
| 148 | Supply only AC volt meter square/round type 0-300 volts suitable for 5/4 KVA single phase voltage stablizers complete all as specified and directed |
| 149 | supply and fix in repair of dimmer type transfromer for 4KVA/5KVA Voltage stablizers all as specified and directed by EIC |
| 150 | Supply only 2 mtr long copper cable 3 core PVC insulated and sheathed 80/.20(2.5 Sqmm) size duly fitted with 3 pin top 20 Amps all as specified and directed Please Enable Macros to View BoQ information |