| 1 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : Bd.G.5Spec. Page No : 315Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 2 | Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 209Specification No : Bd.L.2Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 3 | Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer confirming to Indian Standard : 6524-1983 having 6 milimetre diameter bars three numbers and stirrups at 250 milimetre center to center and fixing in wall with six numbers of holdfast of 12 milimetre diameter bars 500 milimetre long including primer and oil painting, excetra complete. - Frame size 60 milimetre X 100 milimetre. (For First Floor)Item / Page No : 56 / 257Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 4 | Providing and fixing solid core flush door commerical type in single leaf 16 milimetre thick Bison panel cement bonded partical board including teak wood lipping, beading on all four edges, without ventilator commercial type of exterior grade as per detailed drawings, with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats, excetra complete. (For First Floor)Item / Page No : 11 / 246Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 5 | Providing and laying damp proof course 50 milimetre thick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork, excetra complete. (For First Floor) (using ARTIFICIAL SAND).Item / Page No : 1 / 205Specification No : Bd.J.2Spec. Page No : 355Additional Specifications : 1. With addtional specifiactions for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 6 | Providing and fixing European type colour glazed earthenware water closet pan with unplasticized poly vinyl chloride seat and lid with chromium plated brass hinges and rubber buffers including unplasticized poly vinyl chloride vent pipe up to the outside face of wall, without flushing cistern with flush cock and with water jet and necessary fitting including cutting and making good to the walls and floors, testing, excetra complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) (For First Floor)Item / Page No : 22 / 289Additional Specifications : 1. Prior approval of sample and brand by Executive Engineer is necessary before use. 2. The work shall be carried out as per instructions of Engineer in charge. |
| 7 | Providing and laying, fixing polyvinyl chloride pipe of 25 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 23 / 276Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 8 | Providing, laying and fixing polyvinyl chloride pipe of 20 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 22 / 276Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 9 | Providing, laying and fixing polyvinyl chloride pipe of 110 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete.Item / Page No : 28 / 277Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 10 | Providing and fixing 15 milimetre diameter poly vinyl chloride Aqua kraft type of approved make super bib tap with flange including all accessories, excetra complete. (For First Floor)Item / Page No : 35 / 291Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 11 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks1 Test per 50000.00 Number |
| 12 | Add Insurance-0.50%Non-Dsr ItemAdditional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. |
| 13 | Add G.S.T-18.00%Non-Dsr ItemAdditional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. Please Enable Macros to View BoQ information |