|
| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m.beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming,watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means.Page No-189, SSR Item No.-21.02. |
| 3 | Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means.Page No-189, SSR Item No.-21.06 |
| 4 | Providing soling using 80 mm size trap metal in15cm.layer including filling voids with Crushed sand /grit, ramming, watering etc. complete.Page No-194, SSR Item No.-21.40. |
| 5 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand.Page No-216, SSR Item No.-24.08 |
| 6 | Providing and laying in situ/ Ready Mix cement concrete M-20 of trap / granite / quartzite/ gneiss metal for R.C.C. work in foundations like raft , strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water , formwork, laying/ pumping cover blocks, compact ion and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLCwi th SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer ) etc. complete. With natural sand/ V.S.I. quality Artificial Sand.Bd.Page No-219, SSR Item No.-25.11 |
| 7 | Providing and laying Cast in situ/ Ready Mix cement concrete M-20 of trap / granite / quartzite/ gneiss metal for R.C.C. columns as per detai led designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compact ion finishing the formed surfaces wi th cement mor tar 1:3 of sufficient minimum thickness to give a smooth and even sur face or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer ) etc. complete. With natural sand/ V.S.I. quality Artificial SandBd.Page No-221, SSR Item No.-25.31 |
| 8 | Providing and laying Cast in situ/ Ready Mix cement concrete M-20 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and st ructural steel). with fully automatic micro processor based PLCwi th SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer ) etc. complete. With natural sand/ V.S.I. quality Artificial Sand.Page No-223, SSR Item No.-25.50 |
| 9 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.Page No-223, SSR Item No.-25.50 |
| 10 | Providing and laying Cast in situ / Ready Mix cement concrete in M-20 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying / pumping, compaction, finishing un even and honey combed surface with C.M.1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finishis to be provided and curing etc. complete. (Excludinge inforcement, including cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer)etc.complete.With fine aggregate (Crushed sand VSI Grade).Page No-229, SSR Item No.-26.25 |
| 11 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Page No-233, SSR Item No.-26.33 |
| 12 | Providing second class Burnt Brick masonry with convent ional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.Page No-242, SSR Item No.-27.01 |
| 13 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the sur face of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for four teen days scaffolding etc. complete.Page No-257, SSR Item No.-32.11 |
| 14 | Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Page No-173, SSR Item No.-23.02 |
| 15 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/bolted/welded connection and one coat of anticorrosive paint and over it 2coats of oil painting approved quality and shade etc.complete. Page No-173, SSR Item No.-23.04 |
| 16 | Providing and fixing colour coated Zinc alume (R)AZ150 (min 150gms/sq.mt.total one ach side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness (BMT) (0.5mm TCT), Hi-strength steel with min. 550M Payield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6%silicon) with COLORBOND (R)steel quality super durable polyester paint coat (with in organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25um exterior coat on top surface and nominal 10 um reverse coat on back surface. Page No-236, SSR Item No.-38.34 |
| 17 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of 3.15mm thickness reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65mm and 3.15mm respectively with hold fast arrangements, M.S. Bracket plate 300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc.complete.(I.S.62481979)(With mechanical gear) Page No-249, SSR Item No.-39.25 |
| 18 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coatsincluding scaffolding, preparing the surface. (excluding the primer coat)etc. complete.Page No-280, SSR Item No.-36.12 |
| 19 | Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 &18mm Teakwood planks 100x800 having tongue & grove on Sal-wood frame of 50x100 at 600mmc to constage surface including cost of required Cut-Outs, decorative mouldings/finishing-items/polish etc., as per Architectural & Acoustical Design & Instructions & Completein all aspects.including all material slab our, finishing etc complete. Page No-353, SSR Item No.-51.06 |
| 20 | Providing and laying telephone black / Amba White / Cadbury brown / Ruby red / Ocean Brown granite stone of 18 to 20mm thick for door frame / dado / window boxing etc. On C.M.1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete.Page No-264, SSR Item No.-40.07 |
| 21 | TEST ON CONCRETE, Compressive Strength (3 set of cubes) |
| 22 | ROYALTY CHARGES, a) For sand |
| 23 | ROYALTY CHARGES, b) For All Other Minerals |
| 24 | ADD 5% CONTENGIENCES INSURANCE |
| 25 | GST 18 % |
| 26 | Add 0.5% for labour insurance Please Enable Macros to View BoQ information |