| 1 | TEACHING BLOCK REPAIRING / RENOVATION WORK OF EXISTING GROUND FLOOR BUILDING |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground with in 50 metres lead. |
| 3 | Disposal of building rubbish/malba/ similar unserviceable, dismantling or waste material by machanical means, including loading, transporting, unloading to approved municipal dumping groung or as approved by Engineer -in-charge, beyond 50 m intial lead , for all leads including all lifts involved. |
| 4 | 12 mm cement plaster of mix : |
| 5 | 1:4 (1 cement: 4 coarse sand) |
| 6 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 7 | FINISHING WORK |
| 8 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 9 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 10 | Steel work |
| 11 | Finishing walls with Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Outer side |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | FIRST FLOOR BUILDING (Civil Works) |
| 14 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 15 | In cement mortar |
| 16 | Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. |
| 17 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 18 | R.C.C. work in beams, suspended floors, roofs having slope up to 15 ° landings, balconies, shelves, chajjas, lintles, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centring, shuttering, finishing and rainforcement with 1:1.5:3 (1 cement : 1.5 coarce sand including manufactured sand derived from recycled concrete Aggregate (RCA) upto 20% 3 graded stone aggregate 20 mm nominal size derived from natural source). |
| 19 | Shuttering Work In Lintel Band |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 21 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | slabs (Using 1:1.5:3(1 cement : 1.5 coarse sand : 3 stone aggregates) Mix concrete) (M-20) |
| 23 | Shuttering Work In Slab |
| 24 | Suspended floors, roofs, landings, balconies and access platform |
| 25 | Lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone aggregates) Mix concrete) (M-20) |
| 26 | Shuttering Work in Beams |
| 27 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 28 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 29 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 30 | Shuttering Work In Column |
| 31 | Brick work in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:4 cement : coarse sand) |
| 32 | Brick work in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 33 | Providing and laying \\"brick coba\\" 120mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top |
| 34 | mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. |
| 35 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 36 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 37 | 12 mm cement plaster of mix : |
| 38 | 1 : 6 (1 cement : 6 coarse sand) |
| 39 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 40 | 1:4 (1 cement: 4 coarse sand) |
| 41 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 42 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 43 | Size of Tile 600x600 mm |
| 44 | Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. |
| 45 | Area of slab over 0.50 sqm |
| 46 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 47 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 48 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 49 | New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 50 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification. |
| 51 | New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. |
| 52 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 53 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. |
| 54 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge |
| 55 | Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking systemwith cylinder, zinc alloy (zamak) powder coated handles on both sides |
| 56 | Using R3 series with frame (55 mm & above) x (50mm & above) & sash (55 mm & above) x(85mm & above) (Height upto 2.5 metre). |
| 57 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of leadfree uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extrudedprofiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and designduly reinforced with galvanized mild steel section made of required shape & size as perCPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fastenersof minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 gradesleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall be filled with weather proof silicon sealant overbacker rod of approved size and quality, all complete as per approved drawing conformingto CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcementand cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge |
| 58 | Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylonrollers with SS 304 body. |
| 59 | Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x(50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto1.2 metre). |
| 60 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 61 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 62 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 63 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 64 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 65 | Using flats 30x6mm for diagonal braces and central cross piece |
| 66 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles ofSize 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225: 1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistanceof 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coatedT-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary |
| 67 | With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles |
| 68 | INTERNAL W/S AND SANITATION WORK |
| 69 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 70 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 71 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 72 | W.C. pan with ISI marked black solid plastic seat and lid |
| 73 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 74 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls andfloors wherever required : |
| 75 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 76 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 77 | a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 78 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 79 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 80 | Kitchen sink with drain board |
| 81 | 510x1040 mm bowl depth 250 mm |
| 82 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 83 | Semi rigid pipe |
| 84 | 32 mm dia |
| 85 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 86 | Providing and fixing PTMT Bottle Trap for Wash basin and sink |
| 87 | Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms |
| 88 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 89 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 90 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 91 | C.P. BRASS FITTINGS |
| 92 | Providing and fixing unplasticised PVC connection pipe with brass unions |
| 93 | 45 cm length |
| 94 | 15 mm nominal bore |
| 95 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 96 | 15 mm nominal bore |
| 97 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 98 | 15 mm nominal bore |
| 99 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 100 | 110mm (Rainwater+soil+waste) |
| 101 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 102 | 110 mm diameter |
| 103 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 104 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 105 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 106 | Bend 87.5° |
| 107 | 110 mm bend |
| 108 | Shoe (Plain) |
| 109 | 110 mm Shoe |
| 110 | Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work . |
| 111 | a) 150mm dia P.V.C. pipe |
| 112 | b) 110mm dia P.V.C. pipe |
| 113 | c) 75mm dia P.V.C. pipe |
| 114 | Providing and fixing of UPVC SWR door bend confirming to IS-14735. |
| 115 | 110MM |
| 116 | 150MM |
| 117 | Providing and fixing of UPVC Nahani trap size 100/75mm ,100/90 mm confirming to IS -14735 self cleaning design fixed in pcc 1:2:4 and supply and fixing of 125mm dia heavt duty cp brass jali. |
| 118 | Providing and fixing of UPVC SWR cowl confirming to IS-14735. |
| 119 | 110MM |
| 120 | 150MM |
| 121 | Providing and fixing of UPVC Plain TEE confirming to IS-14735. |
| 122 | 75X75X75MM |
| 123 | 110X110X110MM |
| 124 | 150X150X150MM |
| 125 | Providing and fixing of UPVC SWR door y confirming to IS-14735. |
| 126 | 110MM |
| 127 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 128 | Concealed work including cutting chases and making good the walls etc. |
| 129 | 15mm dia nominal outer dia pipes |
| 130 | 20mm dia nominal outer dia pipes |
| 131 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 132 | Internal work-Exposed on wall |
| 133 | 25mm dia nominal bore |
| 134 | 32mm dia nominal bore |
| 135 | 40mm dia nominal bore |
| 136 | 50mm dia nominal bore |
| 137 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 138 | 25mm dia nominal bore |
| 139 | 32mm dia nominal bore |
| 140 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. |
| 141 | Capcity in Per Liters |
| 142 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 143 | 25 mm nominal bore |
| 144 | EXTERNAL PLUMBING AND SEWERAGE WORK |
| 145 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 146 | Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia |
| 147 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) up to haunches of S.W.pipes including bed concrete as per standard design |
| 148 | 150 mm diameter S.W. pipe |
| 149 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. |
| 150 | 150 mm dia. R.C.C. pipe |
| 151 | Providing and fixing square-mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be notless than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 152 | 150 x 100 mm size P type |
| 153 | With common burnt clay F.P.S. (non modular) bricks of class designation M-150 |
| 154 | Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix |
| 155 | (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 |
| 156 | (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. |
| 157 | a) Inside size 90x80 cm & 500cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. |
| 158 | b) Extra for depth of man hole size 90x80 cm |
| 159 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 160 | EXTERNAL WATER SUPPLY SYSTEM -II |
| 161 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 162 | 65 mm dia nominal bore |
| 163 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 164 | 65 mm nominal bore |
| 165 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design |
| 166 | With common burnt clay M-150.(non modular) bricks of class designation. |
| 167 | SEPTIC TANK-1(5.0 MX2.0MX3.0M) |
| 168 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 169 | In all kind of soil upto 1.5m depth |
| 170 | In all kind of soil upto 1.5m to 3.0m. depth |
| 171 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 172 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 173 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 174 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 175 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. |
| 176 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 177 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) -PLINTH PLASTER |
| 178 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 179 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 180 | Providing & fixing 75mm dia vent pipes. |
| 181 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 182 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 183 | M.D. -10- Circular shape 500mm internal diameter |
| 184 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 185 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 186 | Centering and shuttering including strutting, propping etc. and removalof form for |
| 187 | Suspended floors, roofs, landings, balconies and access platform |
| 188 | INTERNAL ELECTRIFICATION WORK |
| 189 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group C |
| 190 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 191 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 192 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 193 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 194 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 195 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 196 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 197 | 4 X 16 sq. mm + 2 X 16 sq. mm earth wire |
| 198 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 199 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 200 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 201 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 202 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 203 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 204 | Upto 450 mm sweep |
| 205 | MCCB, MCB & DB'S |
| 206 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 207 | 8 way (4 + 24), Double door |
| 208 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 209 | Single pole |
| 210 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 211 | 25 amps |
| 212 | 40 amps |
| 213 | 63 amps |
| 214 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 215 | E A R T H I N G |
| 216 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 217 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 218 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 219 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 220 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 221 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 222 | 185 sq. mm 3-1/2 core(2 NO.) |
| 223 | 70 sqmm 3.5 core |
| 224 | 50 sqmm 3.5 core |
| 225 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire |
| 226 | 185 sq. mm 3-1/2 core(2 NO.) |
| 227 | 70 sqmm 3.5 core |
| 228 | 50 sqmm 3.5 core |
| 229 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. |
| 230 | 185 sq. mm 3-1/2 core(2 NO.) |
| 231 | 70 sqmm 3.5 core |
| 232 | 50 sqmm 3.5 core |
| 233 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only |
| 234 | Main L.T. Panel |
| 235 | Incoming : |
| 236 | 400 Amp. MCCB-1 Nos. |
| 237 | Outgoing : |
| 238 | 100 amp MCCB-3no.& 63amp MCCB-3no |
| 239 | Cat. B. Pannel Cubicle Type |
| 240 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 241 | 40AMP TP MCB |
| 242 | 125AMP TP MCB |
| 243 | 63AMP TP MCB |
| 244 | Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules. |
| 245 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. |
| 246 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects. |
| 247 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver setcomplete in all respect. |
| 248 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. Cat. AAA |
| 249 | LED LIGHT (15 WATT) Cat. AAA |
| 250 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. Cat. AAA |
| 251 | Supply and fixing of LED Tube Light with batten suitable for up to 2 X 22 watt LED tube light fitting including tube on Surface complete in all respect. |
| 252 | Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required |
| 253 | Exhaust Fan |
| 254 | FIRE FIGHTING SYSTEM |
| 255 | DOWN COMER WITH WET RISER /EXTERNAL YARD HYDRANT SYSTEM |
| 256 | COST OF DOWN COMER WITH WET RISER /EXTERNAL YARD HYDRANT SYSTEM |
| 257 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp /support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required |
| 258 | 150 mm dia |
| 259 | 100 mm dia |
| 260 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of50 m |
| 261 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 262 | Supplying and fixingfirst aid HoseReel with MS construction spray painted n postofficered,conformingtoIS884completewiththefollowingasrequired.20mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 1258520mm nominal internal dia gunmetal globe valve&nozzle.Drum and brackets for fixing the equipmets on wall.Connections fromriser with 25mm dia stop gunmetal valve & M.S. Pipe and socket 30M |
| 263 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required |
| 264 | Single headed Stainless steel |
| 265 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required |
| 266 | Gun Metal |
| 267 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required |
| 268 | Stainless Steel (Grade 304) |
| 269 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required |
| 270 | 150 mm dia |
| 271 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required |
| 272 | 100mm dia |
| 273 | 150mm dia |
| 274 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required |
| 275 | 150 mm dia |
| 276 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shadeas required. |
| 277 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 278 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) |
| 279 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 280 | Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. |
| 281 | M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered |
| 282 | 450 lpm at 35 m Head |
| 283 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required |
| 284 | 4 way-150 mm dia M.S. Pipe |
| 285 | Providing & fixing of FHC(NewAge Fire Hose Cabinet (Double door) (FRP) Including cost of materials and labour etc complete .Excluding cost of pipe . |
| 286 | Providing&fixing of Exit sign Board Including cost of materials and labour etc complete . |
| 287 | Providing&fixing of Terrace motor covering Including cost of M.S.angle and profile sheet materials and labour etc complete . |
| 288 | PVC TANK AND MOTOR FIXING FOUNDATION |
| 289 | FIRE ALARM AND P.A. SYSTEM |
| 290 | Supplying, installation, testing & commissioning of manual callboxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 291 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 292 | Supplying, installation, testing & commissioning talk back slavestation in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphoneenclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. |
| 293 | Supply, installation, testing and commissioning of 25 mm Outer dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropriate interval and allaccessories as required,(rate for area protected in sqm). |
| 294 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 295 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 296 | speaker cable Single pair, 2-core, 1.5 sqmm |
| 297 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all otherstandard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. |
| 298 | 10 Zone |
| 299 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. |
| 300 | 6 zone panel for fire alarm system |
| 301 | 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all |
| 302 | Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No.Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 303 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 304 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 305 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 306 | PUBLIC ADDRESS SYSTEM |
| 307 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete asrequired. |
| 308 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 309 | Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required. |
| 310 | Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required. |
| 311 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assemblycomplete as required. |
| 312 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 313 | 16 sq. mm 4 core |
| 314 | 25 sq. mm 3-1/2 core |
| 315 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire |
| 316 | 16 sq. mm 4 core |
| 317 | 25sqmm 3.5 core |
| 318 | Supply and wiring of 4 number 10 Sq.mm.FR PVC insulated 1100 V grade Multistrand single core copper conductor cable in 32 mm heavy guage rigid pvcl conduit pipe partly concealed in wall and partly laid in slab along with reinforcement before concreting, with two number 10 SWG copper earth continuity wire including colour wash etc. complete in all respects. |
| 319 | As in item no. 278 (B) but in heavy duty (2 mm thick) PVC conduit with 2 nos 6 sq.mm. FRLSH PVC insulated copper conductor cable as earth continuity wire drawn in conduit. |
| 320 | S&F of 200 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction ofEngineer in charge. |
| 321 | FIRE EXTINGUISHER |
| 322 | Supply and fixing of fire extinguiser ,ABC Type 6.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work |
| 323 | Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. |
| 324 | Supply and fixing of fire bucket 9-11 litres capacity with river sand fill supply of all materials and labour for proper completion of work. |
| 325 | SITC of Emergency light 12 V DC 230 V AC ,Chargable in building complete as per required . |
| 326 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. |
| 327 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. |
| 328 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 329 | Supply and laying of 25 mm x 5 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. |
| 330 | FIRE SPRINKLER SYSTEM |
| 331 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required |
| 332 | 150 mm dia |
| 333 | 100 mm dia |
| 334 | 80 mm dia |
| 335 | 25 mm dia |
| 336 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 337 | 150mm |
| 338 | 100mm |
| 339 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : |
| 340 | Pendent Sprinkler |
| 341 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 342 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, centerbracket, stockbar of following sizes complete as required. |
| 343 | PUMPING SYSTEM |
| 344 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required |
| 345 | 200 mm dia (wall thickness 6.3 mm) |
| 346 | 150 mm dia |
| 347 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m |
| 348 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 349 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required |
| 350 | 150 mm dia |
| 351 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required |
| 352 | 150mm dia |
| 353 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required |
| 354 | 150 mm dia |
| 355 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shadeas required. |
| 356 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required |
| 357 | 4 way-150 mm dia M.S. Pipe |
| 358 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automaticoperation and consisting of following, complete in all respects, as required |
| 359 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. |
| 360 | Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. |
| 361 | M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered |
| 362 | 2280 lpm at 56 m Head |
| 363 | Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel DrivenPump) |
| 364 | Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. |
| 365 | Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. |
| 366 | M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 367 | 2280 lpm at 56 m Head |
| 368 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following,complete in all respects, as required : (Jockey Pump) |
| 369 | Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. |
| 370 | Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. |
| 371 | M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 372 | 180 lpm at 56 m Head |
| 373 | CONTROL PANELS |
| 374 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect,suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required |
| 375 | INCOMING |
| 376 | 630A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switchAmmeter (0-630 A) with selector swtich & CTs etc.LEDtypeRYBphaseindicatinglamps,ON,OFF,tripindicating lampsSet of Copper Bus Bar 800Amps |
| 377 | OUTGOING |
| 378 | Main Fire Pump |
| 379 | 250 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
| 380 | Jockey Pump |
| 381 | 125 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
| 382 | DIESEL ENGINE CONTROL |
| 383 | Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC AmmeterAll standard relays and accessories for automatic operation of diesel engineSystem Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 384 | Providing & fixing of pressures witch in M .S.pipe line including connection etc. as required |
| 385 | Supply and laying of aluminium conductor PVCinsulated armoured served sheathed cables 1100 Voltsgrade at a depth of 750 mm below ground level over acushion of 75 mm. thick sand all around and protectedwith burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size oras directed by the Engineer-Incharge, complete in allrespect. The armouring of the cable shall be properlyconnected with the earth conductor by clamps etc. |
| 386 | 35 sq. mm 3-1/2 core |
| 387 | Providing & fixing of Change over etc. as required |
| 388 | Tubewell |
| 389 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. |
| 390 | All types of soil |
| 391 | 400 mm dia |
| 392 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depthbelow ground level. |
| 393 | 400 mm dia |
| 394 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. |
| 395 | 200 mm nominal size dia having minimum wall thickness 5.40 mm (Casing pipe ) |
| 396 | 150 mm nominal size dia having minimum wall thickness 5.00 mm |
| 397 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.. |
| 398 | 150 mm nominal size dia (Slotted) |
| 399 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fully developed,measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/cdisinfection of tubewell, all complete, including hire & labour charges ofair compressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge. |
| 400 | Providing and fixing suitable size threaded mild steel cap or spot weldedplate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: |
| 401 | 200 mm nominal size dia |
| 402 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nutsf required size complete. |
| 403 | 200 mm nominal size dia |
| 404 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottomof pipe assembly of tubewell as per IS:2800 (part I). |
| 405 | 200mm nominal size dia |
| 406 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work |
| 407 | 80 mm dia nominal bore |
| 408 | CONNECT TO TANK AND FIILED UP TERRACE TANK |
| 409 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. |
| 410 | 3.14*(.200*.200-.100*.100)*140 |
| 411 | Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : |
| 412 | 150 Class I |
| 413 | Supply and fixing of KSB Make 5 HP SUBMIRSSIBLE PUMP |
| 414 | Supply and fixing of nylon jali around the slotted pipes complete as required. Up to 30 meter |
| 415 | Supplying,and fixing of AIR Compressor and clorinator system all complete as per direction of Engineer -in-charge.(For pump room clorinator) |
| 416 | Lab water Testing |
| 417 | Electrical work |
| 418 | Supply and fixing of 80 to 100 amp 4 pole mccb (16ka tharmal magnetic release . |
| 419 | Supply and wiring of 4 number 25 sq. mm. PVCinsulated 1100 V grade single core copper conductorcable in 50 mm dia PVC conduit partly concealed in walland partly laid in slab alongwith reinforcement beforeconcreting with two number 16sq mm single core copperconductor cable as earth continuity wire drawn in couditincluding matching colour wash etc, complete in allrespect.t.(Connection from Transfarmer ) |
| 420 | Same as in item 291 but with 3 nos. 6 sq mm and 2 no 4 sq mm FRLSH PVC insulated copper conductor cable. |
| 421 | UNDER GROUND TANK (5000 Ltr) |
| 422 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 423 | All kinds of soil |
| 424 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 425 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 426 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 427 | Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 428 | UP TO PLINTH |
| 429 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 430 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 431 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 432 | Column |
| 433 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 434 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 435 | RETAINING WALL |
| 436 | PUMPROOM ABOVE UNDER GROUND TANK |
| 437 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 438 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 439 | R.C.C. work in beams, suspended floors, roofs having slope up to 15 ° landings, balconies, shelves, chajjas, lintles, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centring, shuttering, finishing and rainforcement with 1:1.5:3 (1 cement : 1.5 coarce sand including manufactured sand derived from recycled concrete Aggregate (RCA) upto 20% 3 graded stone aggregate 20 mm nominal size derived from natural source). |
| 440 | COLUMN |
| 441 | LINTEL BAND |
| 442 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 443 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 444 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 445 | Column |
| 446 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 447 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 448 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 449 | 40x40x5 |
| 450 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top/centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete ofstandard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted,including providing and fixing of hinges, pivots, including priming coat of approved steel primer, butexcluding the cost of other fittings, complete all as per approved design, (sectional weight of only steelmembers shall be measured for payment). |
| 451 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 452 | 15 mm cement plaster of mix : |
| 453 | 1:4 (1 cement: 4coarse sand) |
| 454 | 12 mm cement plaster of mix : |
| 455 | 1:6 (1 cement: 6 coarse sand) |
| 456 | 12 mm cement plaster of mix : |
| 457 | 1:6 (1 cement: 6 coarse sand) |
| 458 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 459 | 40 mm thick with 20 mm nominal size stone aggregate |
| 460 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand),finished with a floating coat of neat cement. |
| 461 | 18 mm thick |
| 462 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 463 | 40 mm thick with 20 mm nominal size stone aggregate |
| 464 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 465 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 466 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of requiredshade and colour all complete to achieve even shade and colour : |
| 467 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 468 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 469 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 470 | Painting wood work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 471 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 472 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, withnuts and screws etc. complete |
| 473 | 300x16 mm |
| 474 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, withnecessary screws etc. complete : |
| 475 | 300x10 mm |
| 476 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less thangrade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessaryscrews etc. complete |
| 477 | 125 mm |
| 478 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 479 | Single rubber stopper |
| 480 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows,all complete with |
| 481 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 482 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 483 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofingcompound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks forcuring and for final test.“All above operations to be done in order and as directed and specified by the |
| 484 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. * All above operations to be done in order and as directed and specified by the Engineer-In-charge: |
| 485 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 486 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 487 | 110mm |
| 488 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 489 | 110 mm diameter |
| 490 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 491 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 492 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 493 | Bend 87.5° |
| 494 | 110 mm bend |
| 495 | Shoe (Plain) |
| 496 | 110 mm Shoe |
| 497 | ELECTRICAL WORK |
| 498 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 499 | Group C |
| 500 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 501 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 502 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 503 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 504 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 505 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 506 | Upto 450 mm sweep |
| 507 | MCCB, MCB & DB'S |
| 508 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 509 | 40 amps |
| 510 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 511 | E A R T H I N G |
| 512 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 513 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 514 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 515 | Supply & fixing of LED Tube Light with batten suitable for up to 1x22 watt Led tube light fitting including tube Suraface complete in all respect. |
| 516 | Cat. AAA |
| 517 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66protection complete in all respect. |
| 518 | Cat. AAA |
| 519 | Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required |
| 520 | Exhaust Fan |
| 521 | INTELIGENT FIRE ALARM SYSTEM |
| 522 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 523 | Ten Loop Panel. |
| 524 | Two Loop Panel. |
| 525 | Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
| 526 | Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 527 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 528 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 529 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 530 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 531 | Supplying, installation, testing & commissioning of intelligent aspiration detector for area coverage of minimum 5000 sq. ft. complete as required. |
| 532 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 533 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 534 | Supplying, installation, testing & commissioning of addressable phone control module complete as required. |
| 535 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. |
| 536 | Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. |
| 537 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 538 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 539 | Supplying, installation, testing & commissioning of addressable strobe complete as required. |
| 540 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 541 | Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. |
| 542 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 543 | Site Development Works |
| 544 | Boundary Wall (100RM) |
| 545 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 546 | All kinds of soil |
| 547 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 548 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 549 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 550 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Foundation and Plinth in: |
| 551 | Cement Mortar 1:4 (1 Cement : 4 Coarse sand) |
| 552 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :l |
| 553 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 554 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 555 | TOP BAND |
| 556 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 557 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 558 | COLUMN |
| 559 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 560 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 561 | Column |
| 562 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 563 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 564 | Steel work welded in built up sections framed work, including cutting hoisting , fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 565 | In stringers, treads landings etc. of stair cases, including use of chequered plate whereever required, all complete. |
| 566 | Providing & fixing of door / windows grill. |
| 567 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 568 | 12mm cement plaster of mix: |
| 569 | 1:6(1 cement: 6 coarse sand) |
| 570 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 571 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 572 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 573 | New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 574 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 575 | R.C.C. storm water Drain (450X600) 709.10 RM) |
| 576 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 577 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 578 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 579 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :l |
| 580 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 581 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 582 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 583 | C.C. Road (2102.03 SQM) |
| 584 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 585 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 586 | Providing and laying design mix cement concrete of M-30 grade, in roads/taxi tracks/ runways, using cement content as per design mix, using coarsesand and graded stone aggregate of 40 mm nominal size in appropriateproportions as per approved & specified design criteria, providing dowelbars with sleeve/ tie bars wherever required, laying at site, spreading andcompacting mechanically by using needle and surface vibrators, levellingto required slope/ camber, finishing with required texture, including steelform work with sturdy M.S. channel sections, curing, making provision forcontraction/ expansion, construction & longitudinal joints (10 mm wide x50 mm deep) by groove cutting machine, providing and filling joints withapproved joint filler and sealants, complete all as per direction of Engineerin-charge |
| 587 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 588 | Interlocking (2300.43 SQM) |
| 589 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 590 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 591 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 592 | With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 593 | Providing and laying 80 mm thick faciory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compactedbed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 594 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 595 | Guard Room (Civil) |
| 596 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 597 | All kinds of soil |
| 598 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 599 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 600 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) |
| 601 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 602 | With Chlorpyriphos/Lindane E.C. 20% with 1%concentration |
| 603 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 604 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 605 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 606 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 607 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level |
| 608 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 609 | PLINTHN BAND |
| 610 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 611 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 612 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 613 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 614 | Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation M-150 . |
| 615 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 616 | 15 mm cement plaster of mix : |
| 617 | 1:4 (1 cement: 4coarse sand) |
| 618 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 619 | 40 mm thick with 20 mm nominal size stone aggregate RATE= 614.20/SQM |
| 620 | FOR 25 MM THICK |
| 621 | SUPER STRUCTURE |
| 622 | R.C.C. work in beams, suspended floors, roofs having slope up to 15 ° landings, balconies, shelves, chajjas, lintles, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centring, shuttering, finishing and rainforcement with 1:1.5:3 (1 cement : 1.5 coarce sand including manufactured sand derived from recycled concrete Aggregate (RCA) upto 20% 3 graded stone aggregate 20 mm nominal size derived from natural source). |
| 623 | LINTEL |
| 624 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 625 | LINTEL |
| 626 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 627 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 628 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 629 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 630 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level. |
| 631 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 632 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 633 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 634 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 635 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 636 | 40x40x5 |
| 637 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 638 | Fixed to steel windows by welding |
| 639 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 640 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 641 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : |
| 642 | 4.0 mm thick glass panes |
| 643 | 12 mm cement plaster of mix : |
| 644 | 1:6 (1 cement: 6 coarse sand) |
| 645 | 12 mm cement plaster of mix : |
| 646 | 1:6 (1 cement: 6 coarse sand) |
| 647 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 648 | 40 mm thick with 20 mm nominal size stone aggregate |
| 649 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. |
| 650 | 18 mm thick |
| 651 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 652 | Ground floor |
| 653 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete. |
| 654 | Ground floor |
| 655 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 656 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 657 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 658 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 659 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 660 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 661 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 662 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 663 | Providing and fixing Oxidized sliding door bolts, ISI marked to required colour or shade, with nuts and screws etc. complete |
| 664 | 300x16 mm |
| 665 | Providing and fixing Oxidized handles, ISI marked, required colour or shade, with necessary screws etc. complete |
| 666 | 125 mm |
| 667 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the |
| 668 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. * All above operations to be done in order and as directed and specified by the Engineer-In-charge: |
| 669 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 670 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 671 | 110mm (Rainwater+soil+waste) |
| 672 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 673 | 110 mm diameter |
| 674 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 675 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 676 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 677 | Bend 87.5° |
| 678 | 110 mm bend |
| 679 | Shoe (Plain) |
| 680 | 110 mm Shoe |
| 681 | INTERNAL ELECTRIFICATION WORK |
| 682 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 683 | Group C |
| 684 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 685 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 686 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 687 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 688 | 4 X 16 sq. mm + 2 X 16 sq. mm earth wire |
| 689 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 690 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 691 | E A R T H I N G |
| 692 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 693 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 694 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 695 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver setcomplete in all respect. |
| 696 | Cat. AAA |
| 697 | Supply & fixing of LED Tube Light with batten suitable for up to 1x22 watt Led tube light fitting including tube Suraface complete in all respect. |
| 698 | Cat. AAA |
| 699 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit forspeed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required. |
| 700 | INTERNAL SANITARY WORK |
| 701 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 702 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 703 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 704 | a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 705 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 706 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 707 | Semi rigid pipe |
| 708 | 32 mm dia |
| 709 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 710 | Providing and fixing PTMT Bottle Trap for Wash basin and sink |
| 711 | Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms |
| 712 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 713 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 714 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 715 | C.P. BRASS FITTINGS |
| 716 | Providing and fixing unplasticised PVC connection pipe with brass unions |
| 717 | 45 cm length |
| 718 | 15 mm nominal bore |
| 719 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 720 | 15 mm nominal bore |
| 721 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 722 | 15 mm nominal bore |
| 723 | Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work . |
| 724 | a) 110mm dia P.V.C. pipe |
| 725 | b) 75mm dia P.V.C. pipe |
| 726 | Providing and fixing of UPVC SWR door bend confirming to IS-14735. |
| 727 | 110MM |
| 728 | Providing and fixing of UPVC Nahani trap size 100/75mm ,100/90 mm confirming to IS -14735 self cleaning design fixed in pcc 1:2:4 and supply and fixing of 125mm dia heavt duty cp brass jali. |
| 729 | Providing and fixing of UPVC SWR cowl confirming to IS-14735. |
| 730 | 110MM |
| 731 | Providing and fixing of UPVC Plain TEE confirming to IS-14735. |
| 732 | 75X75X75MM |
| 733 | 110X110X110MM |
| 734 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 735 | Concealed work including cutting chases and making good the walls etc. |
| 736 | 15mm dia nominal outer dia pipes |
| 737 | 20mm dia nominal outer dia pipes |
| 738 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 739 | Internal work-Exposed on wall |
| 740 | 25mm dia nominal bore |
| 741 | 32mm dia nominal bore |
| 742 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 743 | 25mm dia nominal bore |
| 744 | 32mm dia nominal bore |
| 745 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. |
| 746 | Capcity in Per Liters |
| 747 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 748 | 25 mm nominal bore |
| 749 | SEPTIC TANK |
| 750 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil. |
| 751 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 752 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 753 | 40 MM C.C.Flooring |
| 754 | Brick work common burnt clay F.P.S.(non modular) bricks of class designationM-150 in foundation and plinth in: |
| 755 | Cement mortar 1 : 4(1 cement : 4 coarse sand) |
| 756 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level |
| 757 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 758 | Suspended floors, roofs, landings, balconies and access platform |
| 759 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: |
| 760 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 761 | 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) |
| 762 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 763 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 764 | Providing & fixing 75mm dia vent pipes. |
| 765 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 766 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 767 | M.D. -10- Circular shape 500mm internal diameter |
| 768 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 769 | With common burnt clay F.P.S. (non modular) bricks of class designation M-150 |
| 770 | Open Surface Appron Drain (230X150 (168.30 RM) |
| 771 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 772 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 773 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 774 | Brick work in 1:4 cement motar (cement : coarse sand) in foundation. |
| 775 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 776 | 12 mm cement plaster |
| 777 | 25mm thick cement concrete 1:2:4 (1 cement :2 coarse sand :4 stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 778 | Rain Water Harvesting |
| 779 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. |
| 780 | In all kind of soil upto 1.5m depth |
| 781 | In all kind of soil upto 1.5m to 3.0m. depth |
| 782 | In all kind of soil upto 3.0m to 4.5m. depth |
| 783 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 784 | Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5 in foundation and plinth in: . |
| 785 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 786 | Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources). |
| 787 | R.C.C. work in Slab |
| 788 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level |
| 789 | thermo-mechnically treated bars |
| 790 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 791 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 792 | With 20x20mm square bar |
| 793 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 794 | M.D. -10- Circular shape 500mm internal diameter |
| 795 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 796 | Drilling of 300mm dia bore hole manually. |
| 797 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 798 | 150 mm nominal size dia |
| 799 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. |
| 800 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 801 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 802 | DESILTING CHAMBER |
| 803 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. |
| 804 | In all kind of soil upto 1.5m depth |
| 805 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 806 | Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5 in foundation and plinth in: . |
| 807 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 808 | Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to the floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement: 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregrate 20mm nominal size derived from natural sources). |
| 809 | R.C.C. work in Slab |
| 810 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level |
| 811 | thermo-mechnically treated bars |
| 812 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 813 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 814 | With 20x20mm square bar |
| 815 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 816 | M.D. -10- Circular shape 500mm internal diameter |
| 817 | DRAINAGE NETWORK |
| 818 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. |
| 819 | Pipes 80 mm to 300 mm diameter |
| 820 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 821 | 150 mm. dia. RCC Pipes |
| 822 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 823 | 150 mm. dia. |
| 824 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of .class designation 7.5 |
| 825 | Horticulture Landscaping & Fountain |
| 826 | Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment). |
| 827 | Supplying and stacking at site dump manure from approved source,including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) |
| 828 | Fine dressing of the ground. |
| 829 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 830 | Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free fromweeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately). |
| 831 | In rows 5 cm apart in both directions |
| 832 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mmthickness of existing ground prepared with proper level and ramming withtools wooden (Dhurmos) and than rolling the surface with light roller makethe surface smoothen and light waterning with sprinkler and maintenancefor 30 days or more till the grass establish properly, as per direction ofofficer-in-charge. |
| 833 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts ofstacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) |
| 834 | Holes 90 cm dia, and 90 cm deep |
| 835 | Providing and installation of tress |
| 836 | Providing and installation of Various type Flower plantation |
| 837 | Gate 6 M wide with Sign Board |
| 838 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. |
| 839 | All kinds of soil |
| 840 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 841 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 842 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 843 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 844 | COLUMN |
| 845 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 846 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 847 | COLUMN |
| 848 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 849 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 850 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 851 | Column |
| 852 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 853 | Granite stone slab of colour black, Cherry/Ruby red |
| 854 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. asrequired.. |
| 855 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 856 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 857 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 858 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 859 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 860 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 861 | Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver whitewith blue colour back ground and with high intensity grade, pasted on substrate bypressuresensitive adhesive backing which shall be activated by applying pressure conforming toclass II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by meansof suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all alongthe periphery as well as in two vertical rows along with theft resistant measures, includingthe cost of painting with two or more coats of epoxy paint in grey colour on the back side ofaluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineerin-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). |
| 862 | Overhead informatory road signage |
| 863 | External Electrification Works |
| 864 | Supply of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade . |
| 865 | 10sqmm 4.0 core |
| 866 | 16sqmm 4.0 core |
| 867 | EXTERNAL WORK |
| 868 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. |
| 869 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. |
| 870 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. |
| 871 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 872 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 873 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 874 | Supply & Fixing of 12.5mtr High mast shaft of approved make with rising system hot dip glavanized inside & Out side dip ,heaving pole sheet thickness 3mm .Top dia minium 150mm .bottom dia 310 mm base palte 25mm thick suitable for wind velocity as per IS 875 part 3& having no circumferential weld ,with accessories for high mast such as head frame suitable for 6 to 6 luminares & its control gear boxes .75 hp power tool motor 3 point sudpenstion system with steel . |
| 875 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 876 | 40 amps |
| 877 | External Electrification Control panel and Fixing on site |
| 878 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc)in each phase withtouch type selector switches for different readings,instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. |
| 879 | Main L.T. Panel |
| 880 | Incoming : |
| 881 | 800 Amp. MCCB-1 No |
| 882 | Outgoing : |
| 883 | 200 Amp. MCCB-4 Nos,100 Amp MCCB- 1 No |
| 884 | Cat. B. Pannel Cubicle Type |
| 885 | Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules. |
| 886 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. |
| 887 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 888 | 35 sq. mm 3-1/2 core |
| 889 | 50 sqmm 3.5 core |
| 890 | 70 sqmm 3.5 core |
| 891 | 185 sq. mm 3-1/2 core |
| 892 | 300 sq. mm 3-1/2 core |
| 893 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire |
| 894 | 35 sq. mm 3-1/2 core |
| 895 | 50 sq. mm 3-1/2 core |
| 896 | 70sqmm 3.5 core |
| 897 | 185 sq. mm 3-1/2 core |
| 898 | 300 sq. mm 3-1/2 core |
| 899 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. |
| 900 | 35 sqmm |
| 901 | 50 sqmm |
| 902 | 70 sqmm |
| 903 | 185 sq. mm 3-1/2 core |
| 904 | 300 sq. mm 3-1/2 core |
| 905 | 2.0 Tone Split AC (Details As per TS Estimate) |
| 906 | OLAR STREET LIGHT (All integrated solar integrated light with 60 w solar panel & GI octagonal pole6m high with foundation) (Details As per TS Estimate) |
| 907 | GST Extra As per Applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail