| 1 | I/1:-V.T.Pump Set Providing, installing ,comm. With test & trial of V.T.Pump set Capable of discharging 135000 LPH Water against a total head of 66 mtr from all causes including bowl assembly, column assembly discharge head ,Sole plate, frame, Pressure gauge,channel iorn & as per detailed specifications etc comp.(Market Rate as per Rate Analysis) |
| 2 | I/2:-VHS Motor:- Providing, installing ,comm. With test & trial of 60 HP VHS motor suitable for above pump set in item No.1 & as per detailed specifications etc comp.(As per R.A) |
| 3 | I/3:- F/A ATS Starter:- Providing, installing ,comm. With test & trial of F/A ATS Starter suitable for 60HP & above motor in item No.2 & as per detailed specifications etc comp.(As per R.A) |
| 4 | I/4:-L.T.Panel board (Cubical type):- Providing, installing ,comm. With test & trial of floor mounting Cubical type L.T. Panel board including all acessories & as per detailed specifications etc comp.(As per R.A) |
| 5 | I/5(a):- Armoured Cable:- Providing, erecting, jointing With test & trial ofAlluminium Armoured cable of type (3.5coreX1X120) sqmm etc.& as per detailed specifications etc comp.(From Transformer to L.T.Panel board)(As per R.A) |
| 6 | I/5(b):-Excavation:- Making the trench in hard murum/Tar road of suitable width & depth for laying provided L.T.Cable of 25 Sqmm & above & covered with half round hume pipe complete. (PWD DSR No.16-1-3,P.No.148 & Note 1&2) (As per R.A) |
| 7 | I/5(C):- Armoured Cable:- Providing, erecting, jointing With test & trial ofAlluminium Armoured cable of type (3 core X 70) sqmm etc.& as per detailed specifications etc comp.(From Panel to Starter & Starter to motor)(As per R.A) |
| 8 | I/6(a):-Earthing Arrangement:- Providing, installing ,comm. With test & trial Earthing arrangement to the installation , motor,starter etc & as per detailed specifications etc comp. |
| 9 | I/6(b):-G.I.Strips:- Providing erecting G.I.Strip for earthing arrangement & as per detailed specifications etc comp.(As per R.A) |
| 10 | I/7(a): 200mmdia Sluice Valve(Cast iron) (PN1.6) Providing, installing ,comm. With test & trial of 200mm dia cast iron Sluice valve with wheels etc comp.& as per detailed specifications etc comp.(As per R.A) (For New Pump & old pump) |
| 11 | I/7(c):- 200mmdia Reflux Valve (Cast iron) (PN 1.6) Providing, installing ,comm. With test & trial of 200mm dia cast iron Non return valve etc comp.& as per detailed specifications etc comp.(As per R.A)(For New Pump & old pump & On Delivery Side) |
| 12 | I/8(a):- M.S.Pipes & Specials:- Providing, erecting, jointing With test & trial of required size M.S.Pipes & Specials etc comp.(As per R.A) |
| 13 | I/8(b):- 200mm dia flanged Joints:- Providing, erecting, jointing With test & trial of 200mm dia flanged Joints with required material rubber packing & nut bolts etc comp.& as per detailed specifications etc comp.(As per R.A) |
| 14 | I/8:(c)200mm dia Dismentalling joints:- Providing, installing . Commissioning with test & trial of 200mm dia Dismentalling Joints etc comp. (As Per RA) |
| 15 | I/9:-C.C.foundation:- Providing, installing ,comm. With test & trial of C.C.foundation block etc comp.(As per R.A)(MJP Civil SSR 23-24 I/P 1b/47) 55881 +10% for HA |
| 16 | I/10:-APFC Panel (Existing & New Pump):- Supplying and erecting 50 kVAr, 3 phase, 50 Hz., Power contactors Derated for micro-processor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable stepsof MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC (PWD E DSR No.6-7-12,P.117) |
| 17 | I/11 (A) :Full-Bore Electromagnetic Flow Meter:- Supply, install and commission Electromagnetic Flow Meter (EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/- 0.5% of measured value & protection as per given specifications for size 100 mm- 1000mm including sensor, transmitter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM/GPRS ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications.200 mm Nominal DiameterFlowmeter(MJP M/EDSR No.WM-3-3,P.101) |
| 18 | I/11(B):-200mm Mechanical Joints :-Supply of C. I. Mechanical Compression Flanged / Socket Tailpiece (Popularly known as I TM Flanged / Socket Tailpiece) suitable for making flanged connection with the plain barrel of C. I.Spun Pipes ( as per - IS - 1536 /2001) and D. I. Pipes ( as per IS: 8329 / 2000).The Tailpiec to be supplied complete with sealing rubber gasket of S.B.R, C.I. Follower Glands and M.S. Nut Bolts. Thewhole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS:1538 /1993. The rates are inclusive of cost of material, freight charges, loading, transportation and unloading at departemental store, excluding GST levied by Gol and GoM in all respect, etc. complete as directed (MJP Civil DSR No.XIII 1 (v) ,P.No.161) |
| 19 | I/12:-Test & Trial:- Giving satisfactory test and trial of pumping machinery for 2 month period etc comp.(As Per RA) |
| 20 | I/13 : LIFTING EQUIPMENT SECTION ( Chain Pulley block & Travelling Trolley)(2Ton): Providing ,erecting tripple spur gear type cahin pulley block & Travelling Trolley (2Ton) suitable for capacity etc comp.(As Per RA) |
| 21 | I/14:-Internal Electrification:- Providing, installing ,comm. With test & trial of Internal Electrification arrangement in jackwell pumping station including four point, two plug, flouroscent tube, CFL street light, with boards & switches ,Inverter & batteries etc. & as per detailed specifications etc comp.(As per R.A) |
| 22 | I/15:-Tools:- Providing set of tools as per detailed specification & rate analysis & as per detailed specifications etc comp.(As per R.A) |
| 23 | gst Please Enable Macros to View BoQ information |