| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Repair/ maintenance of water mains and allied work for static water tank (SWT) and Hydrant System of Pump House and Fire Pump House at 2 ASD Mil Stn Beas under GE Kapurthala Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | S&F of yard hydrant post/ stand post 80 mm dia GI/ MS both flanged type 1.5 m height including taking down unserviceable existing hydrant post and making the good distrubed plinth area. (Note : PCC for repair of plinth area of the hydrant post shall be measured and paid separtely under relevent item of Schedule) |
| 3 | S&F of fire hose cabinet box of 18 gauge MS sheet 800mmx 600mmx 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS Sheet painted fire red out side and red/ brilliant white inside yard and fixing on the exisitng plinth by using welding/ fasteners complete including dismantling existing unsv/ rusted hose box all as specified and directed. |
| 4 | Supply installation testing and commissioning 100% synthetic flex canvas non percolating type confirming to IS 636 RRL hose (type A) ISI marked 63 mm dia x 15 m long with stainless steel male and female coupling (ISI marked) bound and riveted to hose pipes with copper rivets and copper wire as required . |
| 5 | S&F of 63mm dia,15 mtr long rubberised fabric reinforced rubber lined hose including gun metal male and female instantaneous coupling hose conforming to IS:636 type II and coupling conforming to IS 903-1975 complete all as specified. |
| 6 | S&F of male female coupling 63mm gun metal for fixing on fire hydrant including taking out unsv complete all as specified and as directed. |
| 7 | S&F of two way fire brigade inlet/collecting breaching with 63 mm dia gun metal male instanteous inlet complete all as specified and directed |
| 8 | S&F of first aid fire hose reel wall mounted swivel type fitted with 30 mtr long 20mm dia high pressure dunlop hose conforming to IS 5132 with 15mm dia outlet gun metal nozzle with shut off valve as per IS 884- 1969 complete all as specified. |
| 9 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed by Engineer-in-Charge. |
| 10 | Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge. |
| 11 | Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. |
| 12 | Taking down CI/ GI/ DI/ MS ERW pipe outer dia upto 80 mm bore line from trench/wall/floor/roof stacking it for re-use or issued to contrctroctor as credit. |
| 13 | - ditto - all as per above item No. 11 above here in before but pipe of outer dia 100mm bore complete all as specified and directed by Engineer-in-charge. |
| 14 | - ditto - all as per above item No. 11 above here in before but pipe of outer dia 150mm bore complete all as specified and directed by Engineer-in-charge. |
| 15 | - ditto - all as per above item No. 11 above here in before but pipe of outer dia 200mm bore complete all as specified and directed by Engineer-in-charge. |
| 16 | - ditto - all as per above item No.11 above here in before but pipe of outer dia 250mm bore complete all as specified and directed by Engineer-in-charge. |
| 17 | Refixing old retrived serviceable CI/ GI/ DI/ MS ERW pipe line of outer dia 50/ 65 mm bore on trench/wall/floor/roof complete all as specified and directed by Engineer-in-charge. |
| 18 | - ditto - all as per above item No. 16 above here in before but pipe of outer dia 160mm bore complete all as specified and directed by Engineer-in-charge. |
| 19 | - ditto - all as per above item No. 16 above here in before but pipe of outer dia 100mm bore complete all as specified and directed by Engineer-in-charge. |
| 20 | - ditto - all as per above item No. 16 above here in before but pipe of outer dia 150mm bore complete all as specified and directed by Engineer-in-charge. |
| 21 | - ditto - all as per above item No. 16 above here in before but pipe of outer dia 200mm bore complete all as specified and directed by Engineer-in-charge. |
| 22 | Supply, laying, jointing and testing GI tubing 50mm bore heavy class grade in any length with all fitting laid in trench/wall/floor/roof and connecting up with water supply main complete all as specified and directed (Note : Quoted rate deemed to be including all GI fittings and joint materials). |
| 23 | - ditto - all as per above item No. 21 above here in before but GI pipe of 65mm bore complete all as specified and directed by Engineer-in-charge. |
| 24 | - ditto - all as per above item No. 21 above here in before but GI pipe of 80mm bore complete all as specified and directed by Engineer-in-charge. |
| 25 | - ditto - all as per above item No. 21 above here in before but GI pipe of 100mm bore complete all as specified and directed by Engineer-in-charge. |
| 26 | Supply, laying, jointing and testing of MS ERW Pipe (as per IS 3589: 1981) of nominal dia 80 mm bore (thickness minimum 5.4 mm) including specials/fitting laid in trench/wall/floor/roof and connecting up with supply mains complete all as specified and directed (Note : Quoted rate deemed to be including all MS fittings and joint materials). |
| 27 | - ditto - all as per above item No. 25 above here in before but MS ERW pipe of nominal dia 100 mm bore complete all as specified and directed by Engineer-in-charge. |
| 28 | - ditto - all as per above item No. 25 above here in before but MS ERW pipe of nominal dia 150 mm bore complete all as specified and directed by Engineer-in-charge. |
| 29 | - ditto - all as per above item No. 25 above here in before but MS ERW pipe of nominal dia 200 mm bore complete all as specified and directed by Engineer-in-charge. |
| 30 | - ditto - all as per above item No. 25 above here in before but MS ERW pipe of nominal dia 250 mm bore |
| 31 | Supply, laying, jointing and testing new DI (K-7) pipe 80 mm bore centrifugally cast class LA confirming to IS - 1536 spigot and socketed ends in any length laid in trenches complete all as specified and directed. (Note : Quoted rate deemed to be including DI fitting and new run lead joint/ rubber Joint). |
| 32 | - ditto - all as per above item No. 30 above here in before but DI (K-7)100 mm bore complete all as specified and directed by Engineer-in-charge. |
| 33 | - ditto - all as per above item No. 30 above here in before but DI (K-7)150 mm bore complete all as specified and directed by Engineer-in-charge. |
| 34 | S&F in replacement cast iron fitting such as bends, tapers, (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs tee pieces, single branch for spigot and socket and flanged pipe up to 150 mm bore complete all as specified and directed. |
| 35 | S&F in replacment cast iron sluice valve 80 mm bore with flanged ends, ISI mark with gun metal spindle, CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified |
| 36 | - ditto - all as per above item No. 34 here in before but 100 mm dia complete all as specified and directed by Engineer-in-charge. |
| 37 | - ditto - all as per above item No. 34 above here in before but 150 mm bore complete all as specified and directed by Engineer-in-charge. |
| 38 | - ditto - all as per above item No. 34 above here in before but 200 mm bore complete all as specified and directed by Engineer-in-charge. |
| 39 | S&F of non return butterfly valve of size 80mm dia bore complete all as specified and directed by Engineer-in-charge. |
| 40 | S&F of non return butterfly valve of size 100mm dia bore complete all as specified and directed by Engineer-in-charge. |
| 41 | M&L for repair valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in cement mortar 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.(a) M&L for brick work using sub class 'B' (old size bricks) in cement mortar 1:4 (b) M&L for rendering 15 mm thick in cement mortar 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface. |
| 42 | M&L for lead joint suitable for CI pipe 80 mm bore complete all as specified and directed. |
| 43 | M&L for lead joint suitable for CI pipe 100 mm bore complete all as specified and directed. |
| 44 | M&L for lead joint suitable for CI pipe 150 mm bore complete all as specified and directed. |
| 45 | M&L for earth work in trenches / pit and bailing out water to rectfying leaking joint of GI/DI/CI pipe spigot and socket type 80 mm bore including pouring extra lead chieseling and levelling the excavated material after rectifying the leakage complete all as specified. |
| 46 | - ditto - all as per above item No. 44 above here in before but 100 mm bore complete all as specified and directed by Engineer-in-charge. |
| 47 | - ditto - all as per above item No. 44 above here in before but 150 mm bore complete all as specified and directed by Engineer-in-charge. |
| 48 | Supply, install, testing and commissioning of star delta starter panel capacity 45 HP panel size 90cm x 60cm x 40cm enclosures cubical weather and vermin proof totally enclosed made out of 2mm thick CRCA sheet machine pressed of suitble size to operate on 3 Phase 4 wire system 415 Volts, 50 HZ double door with front openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom Gland plate with sufficient numbers of circular cable entery holes, including PCC work, prewired complete duly powder coated with comprising of the following:- (i) Coper bus bar 200 Amps capacitor of suitable length insulated heavy heat shrinkable sleeves etc -04 No. (ii) MCCB 160 Amps FP, 415 Volt 35 KA adjustable thermal & adjustable magnetic stting Ics = 100% Icu = 01 No(in commer). (iii) Thermal overload relay D model cap 20 - 40 Amp with thermal protection Adjustable range.(iv) Capacitor box type standard duty box 3Ph. 10 KVA, 440 V 50 Hz-01 No. (v) Control MCB SP 6 Amp of control - 02 Nos.(vi) Start - Stop illuminated push button red and green colour cat part No for Red XB5AW31M1N and Green Cat part No XB5AW13M1N.(vii) Digital volt meter AC 0 to 500 vots conzerv TM with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal colored code of size 96x96mm cat part No 30002462 -01 No.(viii) Digital Amp meter AC up to 200 Amp with inbuilt selector switch and CT's duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm cat part No 30002461 - 01 No. (ix) Phase indicating lamp LED (R,Y,B) type with MCB SP 6 Amp - 01 set of Three. (x) ON/OFF indicating lamp on incomer feeder for status of feeder - 02 No. |
| 49 | Taking down existing old unsv Fire fighting panel & Supply, install, testing and commissioning of Fire fighting panel , (not less than 180cm x 150cm x 50cm ), CPRI approved, weather/vermin proof, made out of 3.0 mm thick CRCA sheet, factory assembled cubical pattern modular and compartmentalized construction, outdoor type, with front and backside hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, 3 phase and neutral 300 amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support with aluminium earth bus of size 25x3mm with terminal switch, cable galleries, inter connecting bus bar connection/linkage,prewired complete and mounting the panel board on ground with PCC (1:2:4) type B-1 using 20mm graded stone aggregate bedding upto a height of 45 cm above gorund level, complete all as specified and directed by Engr-in-Charge and comprising the following :-INCOMER :-(i) Coper bus bar 300 Amps capacitor of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos.(ii) MCCB 250 Amps FP, 415 Volt 35 KA adjustable thermal & adjustable magnetic setting Ics = 100% Icu -01 NoOUTGOING:-(iii) 02 Nos Star Delta Starter suitable for 75 HP motor , enclosures cubical of suitble size to operate on 3 Phase 4 wire system 415 Volts, 50 HZ, with sufficient numbers of circular cable entery holes, prewired - 02 Nos, and with each Star Delta Starter comprising of , MCCB 200 Amps 3P, 415 Volt 35 KA adjustable thermal & adjustable magnetic stting Ics = 100% Icu -01 No , Power contractor 3 pole 200 Amp (AC 3 duty) AC control different level of power and control contacts, inbuilt 1 No + 1 NC auxillary contacts -03 Nos, Thermal overload relay suitable for 75 HP motor, 3 Ph, 415 V - 02 Nos complete. |
| 50 | (iv) 01 No Star Delta Starter with ,both fully automatic and Manual oparation suitable for 15 HP Jocky pump motor , enclosures cubical of suitble size to operate on 3 Phase 4 wire system 415 Volts, 50 HZ, with sufficient numbers of circular cable entery holes, prewired - 02 Nos, and with each Star Delta Starter comprising of , MCB 40 Amps 3P, 415 Volt 25 KA -01 No , Power contractor 3 pole 32 Amp (AC 3 duty) AC control different level of power and control contacts, inbuilt 1 No + 1 NC auxillary contacts -03 Nos, Thermal overload relay suitable for 15 HP motor, 3 Ph, 415 V - 01 No complete. (v) Single phase preventor system supply 415 Volts, 50Hz VSP3 of Make : minilec or equivalent (vi) Control MCB SP 6 Amp of control - 02 Nos . (vii) Start - Stop illuminated push button red and green colour cat part No for Red XB5AW31M1N and Green Cat part No XB5AW13M1N of (viii) Digital volt meter AC 0 to 500 vots conzerv TM with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal colored code of size 96x96mm make : AE or equivalent -01No (xii) Digital Amp meter AC up to 300 Amp with inbuilt selector switch and CT's duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm - 01No(xiii) Phase indicating lamp LED (R,Y,B) type with MCB SP 6 Amp - 01 set of Three. (xiv) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 No Note:- Scope included all necessary connection of all equiptment for automatic/ manual operation complete. |
| 51 | M&L for draining out water from UG Sump of 50000 gallon capacity by operating wash out valve ,cleaning of UG sump reservoir (inside) by scraping with the help of hard brushes by descaling / brooming silt and other deposit in side (bottom of dome) collecting and taking them out with help of manual labour and depositing not exceeding 50mtr all as directed. Cleaning of inner surface of UG Sump by applying the bleaching powder solution (1:10) and left it for 1/2 hour for making surface algee/ bacteria free .clean the surface with water and drying it quick with the help of electric air blower. Applying two coat of thick quick drying lime wash on entire surface (inner) top and bottom including writting date of cleaning with white paint on back painted surface two places and painting of inner steel ladder of tank all as specified and directed. |
| 52 | Attending complaints by deploying sufficient labour (Skilled and helpers) for repair to leakage/blockage of wall/underground water carrying GI/CI/DI/ MS ERW pipes of sizes 80mm to 250 mm bore of any description at any location including necessary excavation & earth work, cutting existing pipe lines, dewatering etc complete all as specified.NOTE:-(i) Complaint shall be notified to contractor on telephone.(ii) Complaint shall be notified to contractor at any time between 0600 hrs to 2000 hrs and the same shall be immediately attended and defects rectified within eight hrs after receipt of complaint from staff of AGE E&M Sub Division.(iii) Confirmation of attendance & rectification of complaint shall be given in writing by the contractor.(iv) In case the contractor fails to attend complaints within stipulated time (i.e. 6 hrs), a penalty shall be imposed @ Rs 300/- per complaint. (iv) Rates quoted by the contractor shall be deemed to be included the cost of necessary T& P & replacement of CI/GI/DI/MS ERW fitting such as bends, tapers, (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs tee pieces, single branch for spigot and socket and flanged pipe up to 250 mm bore complete. |
| 53 | S&F in replacement MCCB 250 Amp 4 pole 36 KA 415 Volt complete all as specified and directed. |
| 54 | S&F in replacement MCCB 160 Amp 4 pole 36 KA 415 Volt complete all as specified and directed. |
| 55 | S&F in replacement MCCB 100 Amp 4 pole 16 KA 415 Volt complete all as specified and directed. |
| 56 | S&F in replacement MCCB 63 Amp 4 pole 10 KA 415 Volt complete all as specified and directed. |
| 57 | S&F of phase sequance corrector in sheet metal enclosure with phase loss protection system working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 45 HP pump working voltage 440 Voltage etc complete all as specified and directed. |
| 58 | M&L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1 . |
| 59 | Taking out old defective underground cable from trenches/ floors/road/wall /pipe/ pole LT cable of any size/ description including (Note : Excavation and earth work will be measured separately under respective item) |
| 60 | Supply, Laying, jointing and testing XLPE PVC insulated & PVC sheathed LT cable, 1100 volts grade (heavy duty )with stranded aluminium conductor, cross sectional area 50 Sqmm 3.5 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified and directed by Engineer-in-charge.Note (i) Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items. |
| 61 | - ditto - all as per above item No. 58 here in before but cross sectional area 70 Sqmm 3½ core complete all as specified and directed by Engineer-in-charge. |
| 62 | - ditto - all as per above item No. 58 here in before but cross sectional area 95 Sqmm 3½ core complete all as specified and directed by Engineer-in-charge. |
| 63 | M&L for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed by Engineer-in-charge. |
| 64 | Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge. (for LT cable ) |
| 65 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for fdn of poles, stay, valve chambers/ Hydrant post plinth etc; complete all as specified and directed by Engineer-in-charge. |
| 66 | M&L for PCC 1:3:6 type C1 using 20mm graded for padestal coping incl necessary formwork finished fair using extra cement complete all as specified and directed by Engineer-in-charge. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |