| 1 | Servicing of split/ tower/ cassette air conditioning units upto 4.0 Ton capacities, encompassing indoor and outdoor units. The servicing shall include thorough cleaning of air filters, blower, evaporator coil, condenser coil, and drain pipe; checking and tightening electrical connections; lubricating fan motors, verifying thermostat operation; and ensuring efficient cooling performance complete all as specified and directed.(Note: (i) All servicing must be carried out by qualified technicians using appropriate tools and safety gear. (ii) Waste and debris must be properly disposed of after servicing.) |
| 2 | M&L for dismantling the indoor and out door units of the air conditioner split/ tower/ cassette type completely, transporting to workshop for carrying out repairs, leakage, transporting back to the site, re-installing the same on the new/existing location including copper tube, fixing for clamp complete all for satisfactory functioning of the equipment complete all as specified and directed . |
| 3 | Supply and fix in repair starting capacitor for AC upto 100 Mfd complete all as specified and directed |
| 4 | Supply and fix in repair running capacitor for AC upto 50 Mfd complete as specified and directed |
| 5 | Supply and fix in repair starting relay for AC of capacity 3.0/ 4.0 TR complete as specified and directed |
| 6 | Supply and fix in repair starting relay for AC of capacity 1.5/ 2.0 TR complete as specified and directed |
| 7 | Supply and fix in repair Indoor blower/fan for AC of capacity 3.0/ 4.0 TR complete as specified and directed |
| 8 | Supply and fix in repair Indoor blower/fan for AC of capacity 1.5/ 2.0 TR complete as specified and directed. |
| 9 | Supply and fix in repair Indoor blower/fan Motor for AC of capacity 3.0/ 4.0 TR complete as specified and directed. |
| 10 | Supply and fix in repair Indoor blower/fan Motor for AC of capacity 1.5/ 2.0 TR complete as specified and directed. |
| 11 | Supply and fix in repair printed circuit board for Indoor unit of upto 4.0 TR AC as per sample complete as specified and directed |
| 12 | Supply and fix in repair printed circuit board for Outdoor unit of upto 4.0 TR AC as per sample complete as specified and directed |
| 13 | Supply and fix in repair condenser fan motor for AC 4.0 TR complete as specified and directed |
| 14 | Supply and fix in repair condenser fan motor for AC 3.0 TR complete as specified and directed |
| 15 | Supply and fix in repair condenser fan motor for AC 2.0 TR complete as specified and directed |
| 16 | Supply and fix in repair condenser fan motor for AC 1.5 TR complete as specified and directed |
| 17 | M& L for disconnecting and taking down burnt comtressor sealed unit for AC of capacity 4.0 TR from split type AC unit and supply and fixing new compressor as per existing make / model with and including charging of refrigerant gas (R410a / R32 / R134a) after dehydration, testing and vacumming complete as specified and directed |
| 18 | M& L for disconnecting and taking down burnt comtressor sealed unit for AC of capacity 3.0 TR from split type AC unit and supply and fixing new compressor as per existing make / model with and including charging of refrigerant gas (R410a / R32 / R134a) after dehydration, testing and vacumming complete as specified and directed |
| 19 | M& L for disconnecting and taking down burnt comtressor sealed unit for AC of capacity 2.0 TR from split type AC unit and supply and fixing new compressor as per existing make / model with and including charging of refrigerant gas (R410a / R32 / R134a) after dehydration, testing and vacumming complete as specified and directed |
| 20 | M& L for disconnecting and taking down burnt comtressor sealed unit for AC of capacity 1.50 TR from split type AC unit and supply and fixing new compressor as per existing make / model with and including charging of refrigerant gas (R410a / R32 / R134a) after dehydration, testing and vacumming complete as specified and directed |
| 21 | Supply and fix in repair air cooled condensor unit for AC of capacity 3.0/ 4.0 TR complete as specified and directed |
| 22 | Supply and fix in repair air cooled condensor unit for AC of capacity 1.5/ 2.0 TR complete as specified and directed |
| 23 | Supply and fix in repair blower motor for 3.0/4.0 TR AC as per sample complete as specified and directed |
| 24 | Supply and fix in repair blower motor for 1.5/2.0 TR AC as per sample complete as specified and directed |
| 25 | Supply and fix in repair discharge(LP)/ suction(HP) sensor for AC upto 4.0 TR complete as specified and directed |
| 26 | Supply and fix in repair Solenoid valve for AC upto 4.0 TR complete as specified and directed |
| 27 | Supply and fix in repair Coil Senser/ room Senser for AC upto 4.0 TR complete as specified and directed |
| 28 | Supply and fix in repair swing motor for AC upto 4.0 TR ACs complete as specified and directed |
| 29 | Supply and fix in repair outdoor unit fan blade for upto 4.0 TR AC as per sample complete as specified and directed |
| 30 | Supply and fix in repair cooling coil as per sample for AC of capacity 3.0/ 4.0 TR complete as specified and directed |
| 31 | Supply and fix in repair cooling coil as per sample for AC of capacity 1.5/ 2.0 TR complete as specified and directed |
| 32 | Supply and fix in repair contactor as per sample for AC of capacity 3.0/ 4.0 TR complete as specified and directed |
| 33 | Supply and fix in repair contactor as per sample for AC of capacity 1.5/ 2.0 TR complete as specified and directed |
| 34 | Supply and fix in repair brass valve for AC up to 4.0 TR complete as specified and directed |
| 35 | Supply and fix in repair outdoor stand for AC up to 4.0 TR complete as specified and directed |
| 36 | Supply and fix in repair copper pipe of size 1/2\\" with insulation foam complete as specified and directed |
| 37 | Supply and fix in repair copper pipe of size 1/4\\" with insulation foam complete as specified and directed |
| 38 | Supply and fix PVC drain pipe as per sample for ACs complete as specified and directed |
| 39 | Supply and fix in repair PVC insulated copper FRLSH grade cable three core and 2.5 sqmm wire |
| 40 | Supply and fix PVC conduit/ pipe 25mm dia incl necessary fittings such as elbow/ bends/ clamps/ tee to connect all the AC drain pipe to bldg drain at multi story bldg complete all as specified and directed. |
| 41 | Supply and fix insulation foam for ACs complete all as specified and directed. |
| 42 | Supply and fix PVC Plug Top suitable for Split/Window AC/fridge/Deep Freezer/Water Cooler for connecting in Power Socket complete all as specified and directed. |
| 43 | Repairing to Voltage stabiliser including replacing the defective parts like relay, bridge, transformer, glowing lamps and making serviceable for automatic operation, for input variation between 170 to 250 volt and output voltage stabilised at 230 volt with accuracy of + 2.5% of capacity 4.0 / 5.0 KVA complete all as specified and directed. |
| 44 | Supply and replace electronic remote control hand set with stand suitable for Split AC of upto 4.0 Ton capacity of existing make and model complete all as specified and directed. |
| 45 | M&L for recharging of refrigerants gas in split type ACs/Water Coolers / refrigerator/Deep Freezers complete all as specified and directed. |
| 46 | Supply and fix in repair thermostat switch with knob for water cooler/ refrigerator/ deep freezer complete all as specified and directed. |
| 47 | Supply and fix in repair push tap inner/outer thread chromimum plated of size 1/2 \\" for water cooler complete all as specified and directed. |
| 48 | Supply and fix rubber gasket with PVC sheet for top lid for water cooler complete all as specified and directed. |
| 49 | Supply and fix in repair capacitor for water cooler complete all as specified and directed. |
| 50 | Supply and fix in repair starting relay as per sample for water cooler complete all as specified and directed. |
| 51 | Supply and fix in repair SS waste water tray as per sample complete all as specified and directed. |
| 52 | M& L for disconnecting and taking down burnt comtressor sealed unit for water cooler of capacity upto 120 Ltrs and supply and fixing new compressor as per existing make / model with and including charging of refrigerant gas (R410a / R32 / R134a) after dehydration, testing and vacumming complete as specified and directed |
| 53 | Supply and fix in repair condenser unit for water cooler complete all as specified and directed. |
| 54 | Supply and fix in repair overload protection for water cooler complete all as specified and directed. |
| 55 | Supply and fix in repair capillary tube for water cooler complete all as specified and directed. |
| 56 | S&F in repairs 15 mm ball brass valves, high pressure with polyethylene float and flynut complete screwed for iron pipe on or brass ferrule and fixed complete all as specied and as directed. |
| 57 | S & F in repairs modular AC Box(white),plug and 3 pin socket two in one,all in one type,single pole and neutral box with one single pole MCB 20 A mp 230 Volts complete all as specified and directed.Make- Havells cat no. DHDMCSN0251016 or equivalent. |
| 58 | Servicing of upto 25-litre electric storage geysers , including inspection and cleaning of the inner tank, heating element, and thermostat; removal of scale and sediment deposits; checking and tightening of electrical connections; inspection of inlet/outlet valves and pipelines for blockages or leaks; and verification of thermostat settings and safety valve operation. The outer body and wiring shall be checked for damage or corrosion complete all as specified and as directed. |
| 59 | Supply and fix in repair heating coil up to 2 KW for geyser as per sample complete all as specified and directed. |
| 60 | Supply and fix in repair thermostat for geyser as per sample complete all as specified and directed. |
| 61 | Supply and fix in repair non-return valve brass chromium plated 15 mm / 20 mm for geyser as per sample complete all as specified and directed. |
| 62 | Supply and fix in repair geyser assembly as per sample complete all as specified and directed. |
| 63 | Taking down carefully ceiling fan BLDC type 1200/1400mm Sweep from existing location carrying out rewinding, replacement bearing, painting, cleaning, replacement of BLDC driver/ PCB and servicing and refixing in existing/new location incl make electric connection with PVC insulated copper conductor cable from fan to ceiling rose complete all as specified and directed. |
| 64 | Taking down carefully Exhaust fan PVC body type of Size 250mm from existing location carrying out rewinding of motor incl replacement of fan, louvers shutter, motor shaft and frame cleaning and servicing and refixing in existing/new location incl make electric connection with PVC insulated copper conductor cable from fan to ceiling rose complete all as specified and directed. |
| 65 | All as per Item No. 64 above but for Exhaust fan PVC body type of Size 150mm. |
| 66 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4KVA Complete all as specified and directed Please Enable Macros to View BoQ information |