| 1 | EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All Kind of soil |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete. |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | PCC WORK |
| 6 | 1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1%concentration |
| 8 | CONCRETE WORK |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works up to plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg/cum |
| 10 | BRICK WORK |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). |
| 14 | STEEL WORK |
| 15 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. DSR 2023 Item No. 10.25.2 |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 18 | PLASTER WORK |
| 19 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. |
| 20 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. |
| 21 | 12mm thick plaster in 1:3 cement & coarse sand on ceiling and soffits of stairs upto floor two level. |
| 22 | FLOORING WORK |
| 23 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 25 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement: 4 coarse sand):25 mm thick |
| 26 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate |
| 27 | PAINTING WORK |
| 28 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 29 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 30 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 31 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 32 | INTERLOCKING & CC WORK |
| 33 | Construction of granular sub-base by providing wall graded material, spreading in unifrom layers with motor grader/ tractor mounted appropriate equipment on propared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth MORD Specification 401 But Excluding G.S.T |
| 34 | Construction of un-reinforced plain cement concrete pavement as per desing over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M 30 Grade coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceedung 25 mm mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix desing, laid in approved fixed side frame work (steel channel, laying and fixing of 125 micron thick polythene film, wedhes, steel plates including leveling the framework as per drawing), sprading the concrete with shovels, rakes compacted using needle, screed and plate vibrators and finished in continious operation including provision of contraction and expansion, construction joints by providing 12mm thick dura board at the specified spacing, applying debonding strips primer, sealant near approaches to bridge/ culvert and construction joints admixtures as approved, curing of concrete slabs for 14-days and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 But Excluding G.S.T |
| 35 | Providing, supply & fixing of 80 mm thick ruber moulded vibratory interlocking tiles by high pressure & controlled vibration machine having plain dimension 200 X (160+120 mm) with minimum 5mm thick topping of O.P. Cement mixed with 25% marble powder. The Compressive strength of concrete paver blocks shall not be less than 300 mpa & 4.5 Kg/Ton including levelling & dressing of surface to required level & slope, filling joints with local sand over G.S.B. and also including cost of all labour, material but excluding cost of G.S.B. and T&P etc. required for proper completion of work as per direction of Engineer-in-charge but exccluding GST |
| 36 | Electrical Work |
| 37 | Wiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. |
| 38 | Same as item No.(1) but for 5 amp plug point with piano type switch and socket etc. |
| 39 | Same as item No.(1) but for call bell in PVC conduit with 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earthwire drawn in side the condute. |
| 40 | Same as item No.(1) but for light duty exhaust fan. |
| 41 | Same as item No.(1) but for fan and wall fan. |
| 42 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FR PVC insulated 1100 V grade single core multistrands copper conductor cable in 20 mm dia heavyrigid steel conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete and T & P etc. required for proper completion of the work as directed by Engineer in charge. |
| 43 | Supply and laying of 25mm dia heavy guage 16 SWG (1.5 mm thick) PVC conduit complete with bends and other acessories as required and 14 SWG fish steel wire etc. in slab alongwith reinforcement before concreting and plastering but heavy duty (2mm thick) PVC conduit of 25 mm etc, complete in all respect. |
| 44 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 45 | Supply and wiring of submain 2 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 46 | Supply and wiring of submain 4 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with 2 number 6 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 47 | S/fixing of Hexagonal fan box 16 SWG, including phenolic fan sheet. |
| 48 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. (CAT-AAA) |
| 49 | S/F of surface/flush mounting 4 ways TPN distribution board without MCB with additional metal door complete in all respect and as directed at site. CAT-AAA |
| 50 | S/F & 5Amp./6/… 32Amp. MCB 9 K.A. / 10 K.A. CAT-A |
| 51 | Making of joints in GI strip i/c fixing with GI nut & bolt and soldering |
| 52 | S/F of fan step regulator socket type |
| 53 | Supply and fixing of power plug with 15A/240 V flush type switch and 6 pin 20A/10A 250 V flush type universal socket complete with GI box modular tyepe inluding supply of all material, labour T&P etc. required for proper completion of work |
| 54 | Erection and testing of exhaust fan on the existing hole with suitable size |
| 55 | supply and fixing of call bell of approved make |
| 56 | Erection and testing of ceiling fan and regulator etc excluding supply of downrod |
| 57 | Supply and fixng of 1200 mm sweep Ceiling fan ISI marked complete with fan down rod of required size |
| 58 | Supply and fixing of 300 mm sweep 900 RPM exhaust fan heavy duty with the help of MS fasteners, including making connections, making of hole in wall fixing of MS drum & MS louvers of required size |
| 59 | Decorative Square Lighting Pole |
| 60 | Supply and fixing of Dual Arm, CNC Surface Finish with Laser Cutting Decorative Square Lighting Pole of Mild steel including Heavy RCC Foundation and inbuilt Led Light 40 watt x 4 nos with following dimensions Length 12 Feet, Sheet Thickness 04mm Including all Complete. |
| 61 | Supply and Laying of aluminum conductor PVC insulated armoured served sheathed cable 35 sq-mm 2 core Under Ground S.N. 20a 1.11 |
| 62 | Supply and fixing of plain or pin type copper tin plated cable socket (lug ) to the cable leads, insulating with tape and making connection etc complete in all respects. S.I. No. 504(F) |
| 63 | Supply and Fixing of 1.5 Sq-mm PVC round 2 core copper cable. |
| 64 | Supply and Fixing of 10 KW Automatic Street Light Cubicle Control Panel painted with anti corrosive alkali and acid Proof paint consisting of time switch TSO 100 Series with contactors, HRC Fuses, isolating switch metering instrument and instruments box with CTs etc complete all respect. |
| 65 | 18% GST Please Enable Macros to View BoQ information |