| 1 | Construction of Road and Drain work in Anjani ViharMain Roasd in Sikar. |
| 2 | Dismantling of existing structures like culverts, bridges, retainingwalls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffoldingwherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with alllifts and lead of 50 metres as directed by Engineer.Cement Concrete Grade M-15 and above and PCC blocks |
| 3 | Construction of embankment with approved material obtained from borrow pit with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of table 300-2 including cost of compensation for earth taken from private land complete as per MoRT&H specification clause 305. (Lead taken upto 5 km) |
| 4 | Carriage of Materials by mechanical transport including loading, unloading andstacking :: Stone, boulders, gravelly material(Taken Lead UP to 2kms) |
| 5 | Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in concrete mixer, laid manually, compacted with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. |
| 6 | Providing and laying un-reinforced, plain cement concrete mix with Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints etc including all material, labour, machinery, lighting, guarding and maintenance of diversion.PCC M-20 |
| 7 | Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP4 class (with s/s ends) IS: 458 - 2003 (amended up to date) marked and pipes from 300 mm and upto 1800 mmmanufactured through vertical casting process at all depths with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382(including cost of Rubber gaskets, lubricants) as per drawing,sectional hydro testing of the sewer pipe line (including cost andconveyance of water to site for testing) etc., complete as per specification and / or as directed by Engineer.Note : E/w to be measured and paid separately 300 mm internal diameter |
| 8 | Providing and fixing of reinforced Ferro-Cement drain covers designed for 'AA' class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosivebitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistancecompound, abrasion resistant complete as per approved design etc.Standard Size 1000x800mm (100mm thick) for span 451 to 700mm |
| 9 | Providing and fixing of reinforced Ferro-Cement drain covers designed for 'AA' class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosivebitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistancecompound, abrasion resistant complete as per approved design etc.Standard Size 1500x600mm (125mm thick) for span 701 to 1200mm |
| 10 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 11 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel : 1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate40 mm nominal size) |
| 12 | Centring and shuttering with plywood or steel sheet upto two storiesor height upto 7.5 metre above plinth level including strutting,propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 13 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) |
| 14 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded20mm nominal size stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost ofnosing of steps etc. complete. 40mm thick Please Enable Macros to View BoQ information |