| 1 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 Sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of walls complete including disposal of rubbish to dumping ground, all complete as per direct of Engineer-in-charge With cement motar 1:4 (1 Cement : 4 Fine sand) |
| 2 | Dismentling old plaster or skirting ranking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground with in 50 meters lead |
| 3 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and prepering the surface smooth including necessary repairs to scratches etc. complete |
| 4 | Providing and applying white cement based putty of average thickneess1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smoooth complete |
| 5 | Distermering with Oil bound washable distemper of approved branded manufacture to give an even shade: New work ( two or more coats) over and including water thinable priming coat with cement primeer |
| 6 | Finishing walls with ready mixed premium acrylic emulsion paint (CompantDepot tinted) having VOC less than 50 gm/liters and UV resistance as per IS 15489:2004, Alkali and fungal resisitance, dirt resistance exterior paints of requried shade with silicon addives. New Work ( Two or more coas applied @1.43 liters/10 SqM over and including priming coat of exterior primer applied @ 0.90liters/10 SqM. |
| 7 | Painting with synthetic enamel paint of approved brand and manufecture od requried colour to give an even shade: Two or more coats on new work over an under coat of suitables shade with ordinary paint of approved brand and manufactures |
| 8 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge |
| 9 | Demolishing R.C.C work manually/ by mechhinal means including stacking of steeel bars and disposal of unserviceable material with in 50 metrs leads as per direction of engineer in charge |
| 10 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge |
| 11 | Providing and fixing ISI marked flush door shutters conferming to IS 2202(Part1) non decorative type, core of block board construction with frame of 1s class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 12 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using MS angels 40x40x6 mm for diagonal braces |
| 13 | Brick work with common burnt clay modular brick of class designation 7.5 in foundation and plinth in Cement Motar 1:4 (1 cement : 6 coarse sand) |
| 14 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement motar 1:5 (1 cement : 5 coarse sand ) with joints finished flush Red sand stone |
| 15 | Chequerred precast cement concrete tiles 22 mm thick in footh path and courtyard jointed with neat cement slurry mixxed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete. On 20 mm thick bed of cement motar 1:4 (1 cement : 4 coarse sand) Dark shade pigment using ordinary cement |
| 16 | Dismentelling doors, windows and clearstory window (steel or wood) shutter including chowkhats architave, holdfast etc. complete and stacking with in 50 meters lead : of are beyong 3SqM |
| 17 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cergent slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 18 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive waym or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work 1:1.5:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size frived from natural sources) |
| 20 | G.S.T Extra as per applicable Please Enable Macros to View BoQ information |